Megahertz Bandwidth Bulk Micromachined Optomechanical Accelerometer With Fiber Optical Interconnects.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. The TRUST project consists of five "low-complexity", single-feature testbeds used to conduct experiments with accompanying models and simulations. Each of the five single feature testbeds aims to isolate an engineering feature or behavior of interest, then work towards improving the fundamental engineering understanding of that feature. Additionally, the single feature testbeds are used to identify capability development needs that can help reduce model and experimental uncertainty.
The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computa tional and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. The TRUST project consists of five "low-complexity", single-feature testbeds used to conduct experiments with accompanying models and simulations. Each of the five single feature testbeds aims to isolate an engineering feature or behavior of interest, then work towards improving the fundamental engineering understanding of that feature. Additionally, the single feature testbeds are used to identify capability development needs that can help reduce model and experimental uncertainty.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Fiber optic distributed acoustic sensors (DAS) are becoming a widely used tool for seismic sensing. Here we examine recordings of two subsurface chemical explosions, DAG-1 and DAG-3, each of which was about one metric ton (TNT equivalent), that were recorded from a helical fiber installed in two boreholes 80 m away from the source location. Several clear phases including the initial P wave, a weak S wave, and a surface reflected P wave are observed on the helical DAS data. We estimate a velocity model using arrival times measured from the fiber. The DAS waveform data were compared with colocated accelerometers at specific depths in both frequency and time domains. Furthermore, the spectra of the DAS data matched spectra estimated from the accelerometer records. Comparisons of observed waveform shape between the accelerometer records and the fiber measurements (strain-rate) show reasonable agreement except for the data near the event depth. The DAS data and the accelerometer agreed in relative amplitudes but we had difficulties in matching absolute amplitudes, possibly due to errors in metadata. Synthetic strain-rate waveforms were calculated using a 2D wavenumber algorithm and matched the waveform shape and relative amplitudes. In general, DAS is effective at recording strong ground motions at high spatial density. Comparison of the synthetic seismograms with observed data indicate that the waveforms are not consistent with a pure isotropic explosion source and that the observed S waves originate from very near the source region.
The spindle balancing operation is critical to the performance of precision lathes and should be conducted anytime the configuration of the spindle or its tooling is modified such that an unbalanced condition may occur. Within the machine tool community, accelerometers are typically used as the feedback device during the balancing operation. At Lawrence Livermore National Laboratory (LLNL), we have nearly 40 years of history using displacement sensors, such as capacitance gauges, in place of accelerometers when balancing precision spindles. The process of balancing a precision machine spindle using displacement sensors is presented in the context of two work examples. In this case, the details of the one-dimensional balancing operation performed after replacing a flycutter on the spindles of two unique large optic diamond turning machines is discussed. The pros and cons of accelerometer driven balancing and displacement driven balancing are also presented. In the accelerometer context, the level of balance achieved for our work example is less than 100 micro-g or a total indicator reading (TIR) of 1.6 µm. The process of balancing has been enhanced over the years as advances have been made in software, data acquisition systems, and instrumentation. The balancing system is described including details about instrumentation, set-up, how phase and spindle structure stiffness is calculated, and how the LLNL developed software that guides the user through the process by suggesting corrective action.
Modern navigation systems integrate the global positioning system (GPS) with an inertial navigation system (INS), which complement each other for correct attitude and velocity determination. Here, the core of the INS integrates accelerometers and gyroscopes used to measure forces and angular rate in the vehicular inertial reference frame. With the help of gyroscopes and by integrating the acceleration to compute velocity and distance, precision and compact accelerometers with sufficient accuracy can provide small–error location determination. Solid–state implementations, through coherent readout, can provide a platform for high performance acceleration detection. In contrast to prior accelerometers using piezoelectric or capacitive readout techniques, optical readout provides narrow–linewidth high–sensitivity laser detection along with low–noise resonant optomechanical transduction near the thermodynamical limits. Here an optomechanical inertial sensor with an 8.2 µg Hz –1/2 velocity random walk (VRW) at an acquisition rate of 100 Hz and 50.9 µg bias instability is demonstrated, suitable for applications, such as, inertial navigation, inclination sensing, platform stabilization, and/or wearable device motion detection. Driven into optomechanical sustained–oscillation, the slot photonic crystal cavity provides radio–frequency readout of the optically–driven transduction with an enhanced 625 µg Hz –1 sensitivity. Measuring the optomechanically–stiffened oscillation shift, instead of the optical transmission shift, provides a 220× VRW enhancement over pre–oscillation mode detection.
Nuclear microreactors are a unique reactor design which may allow for the nuclear energy industry to tap into unconventional markets, and their modularity presents some advantages over larger, conventional reactor designs. For nuclear microreactors to be economically viable, on-line structural health monitoring may be necessary to reduce operation and maintenance costs with lower power production. Optical fiber sensors, and specifically optical Fabry-Pérot cavities (FPCs), may present the opportunity to monitor vibrational frequencies of microreactor components during operation, enabling identification of the location and severity of potential damage. In this work, FPCs were designed and fabricated with materials which may be able to survive in the extremely harsh environment of nuclear microreactors. The FPCs were bonded to metal test specimens to monitor their vibrational frequencies, along with a reference piezoelectric accelerometer. Euler-Bernoulli theory was used to calculate the fundamental modes and mode-shapes to compare with experimentally measured frequency spectra. The peak frequencies detected with the FPC and piezoelectric accelerometer, and theoretical modes, all agreed well for the first four fundamental modes (within 5%). Furthermore, when the FPC and accelerometer were co-located on the test specimen, their peak frequencies all agreed within 1%.
WBV (Whole-Body Vibration) for operators of seated and standing lawn mowers was conducted during landscape activities from April 2019 through August 2019 at various locations around LLNL Site 200. Mowing is generally performed by each landscaper for 2-3 days every other week with a maximum duration of 3-5 hours each day. On mowing days, other tasks are performed for the remainder of the day that do not expose the worker to WBV such as irrigation, blowing, or sweeping. The mowing terrain at LLNL is variable with typical reported conditions such as gopher holes, exposed tree roots, quick turns, normal and high growth, weeds, and mushy/wet ground that can result in jolts to the mower operator. The Larson Davis HVM200 seat pad with tri-axial accelerometer was used for monitoring workers. For the seated mowers, the HVM200 seat pad with tri-axial accelerometer was placed on the seat between the user and seat pan of the mower. For standing mowers, the seat pad with tri-axial accelerometer was wrapped with Dycem (for seat pad protection) and placed directly on top of the mower deck and underneath the end-user’s right foot. Monitoring for WBV was conducted while operators used different types, makes, and models of mowers. A total of sixteen samples were collected from the operators of seated mower and 6 samples were collected from operators of standing mower. This initial data sampling was part of a discovery phase to identify if WBV exposure met the 2016 ACGIH TLVs (Threshold Limit Values). This initial data identified that workers operating the mowers do not exceed either the TLV or Action Level (AL) for Weighted Acceleration Levels (A(8)) but typically exceed the Vibration Dose Value (VDV) lower boundary for the standing mowers.
The TRUST testbed was designed and fabricated to conduct vibration testing and validate the behavior of hyper-elastic foams in a pre-loaded condition. The main goals of this testbed design were to ensure symmetry, proper instrumentation alignment and mounting, simplified geometry to make the data analysis validation process more straightforward, and to apply and monitor the applied pre-load. Based off of the test parameters, a shaker system was purchased. The baseplate was designed to mount directly to the bolt holes provided on the top of the shaker table. It was determined that the specimens will be cylindrical and vary in thickness from 2-10mm. The baseplate riser, center-mass, and testbed cap were designed to be cylindrical to make alignment about the center axis more straightforward. It was determined to fabricate the parts previously mentioned using Aluminum 6061-T6 due to its stiffness in order to reduce the likelihood of the stiff material impacting the data being collected for the foam specimens. The design concept used to apply the pre-load to the testbed was a through bolt/nut configuration. A through hole was included in each piece of the testbed, specimens, and instrumentation large enough to allow for 1/8” clearance between the through bolt and each of these pieces. This was imperative to avoid causing friction and complicating the validation model. A load cell was then purchased and used to measure the pre-load being applied to the testbed. It was also required to collect data for 3 axes at 3 different locations 120° apart on the center-mass. This configuration was required to be placed on the cylindrical face and toward the top and bottom of the center-mass. Slots were milled out in the middle of each sensor block with tight tolerances for mounting each of the accelerometers at 120° apart. This same approach was taken to mount 2 accelerometers on the baseplate at 180° apart. Holes were milled out of the corners of each accelerometer mounting slot to relieve the corner and allow for a flat edge at the back of each slot. Sensor blocks were mounted into the center-mass using 6-32 bolts at the required locations. This initial testbed design was fabricated at the TA53 machine shop.
The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.