Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Space vehicle accelerometer applications

The physics of accelerometer applications are reviewed, and details are given on accelerometer instruments and the principles of their operations. The functions to which accelerometers are applied are listed, and terms commonly used in accelerometer reports are defined. Criteria guides state what rule, limitation, or standard must be imposed on each essential design element to insure successful design. Elaboration of these criteria in the form of recommended practices show how to satisfy each of these criteria, with the best procedure described when possible.

Source record↗

New accelerometers under development

The commercial viability of the Space Station requires that it provide a micro-g, or submicro-g environment to users. This represents significant improvement over existing systems. Attainment of the lowest micro-g levels requires isolation systems. Passive and active systems have been evaluated. Best performance is achieved using active approaches where accelerometer sensors close feedback loops. Two emerging accelerometer technologies are presented that have promise for meeting performance goals while achieving reductions of package size, weight, and power. The technologies addressed are Honeywell's design concept for an optical cavity locking accelerometer and the recent development of an integrated silicon accelerometer for government applications.

Wald, Jerry↗

Proposed ground-based control of accelerometer on Space Station Freedom

This paper describes the innovative control of an accelerometer to support the needs of the scientists operating science experiments that are on-board Space Station Freedom (SSF). Accelerometers in support of science experiments on the shuttle have typically been passive, record-only devices that present data only after the mission or that present limited data to the crew or ground operators during the mission. With the advent of science experiment operations on SSF, the principal investigators will need microgravity acceleration data during, as well as after, experiment operations. Because their data requirements may change during the experiment operations, the principal investigators will be allocated some control of accelerometer parameters. This paper summarizes the general-purpose Space Acceleration Measurement System (SAMS) operation that supports experiments on the shuttle and describes the control of the SAMS for Space Station Freedom. Emphasis is placed on the proposed ground-based control of the accelerometer by the principal investigators.

Delombard, Richard↗

Proposed ground-based control of accelerometer on Space Station Freedom

This paper describes the innovative control of an accelerometer to support the needs of the scientists operating science experiments that are on-board Space Station Freedom (SSF). Accelerometers in support of science experiments on the shuttle have typically been passive, record-only devices that present data only after the mission or that present limited data to the crew or ground operators during the mission. With the advent of science experiment operations on SSF, the principal investigators will need microgravity acceleration data during, as well as after, experiment operations. Because their data requirements may change during the experiment operations, the principal investigators will be allocated some control of accelerometer parameters. This paper summarizes the general-purpose Space Acceleration Measurement System (SAMS) operation that supports experiments on the shuttle and describes the control of the SAMS for Space Station Freedom. Emphasis is placed on the proposed ground-based control of the accelerometer by the principal investigators.

Delombard, Richard↗

Operational Data Reduction Procedure for Determining Density and Vertical Structure of the Martian Upper Atmosphere from Mars Global Surveyor Accelerometer Measurements

The success of aerobraking by the Mars Global Surveyor (MGS) spacecraft was partly due to the analysis of MGS accelerometer data. Accelerometer data was used to determine the effect of the atmosphere on each orbit, to characterize the nature of the atmosphere, and to predict the atmosphere for future orbits. To interpret the accelerometer data, a data reduction procedure was developed to produce density estimations utilizing inputs from the spacecraft, the Navigation Team, and pre-mission aerothermodynamic studies. This data reduction procedure was based on the calculation of aerodynamic forces from the accelerometer data by considering acceleration due to gravity gradient, solar pressure, angular motion of the MGS, instrument bias, thruster activity, and a vibration component due to the motion of the damaged solar array. Methods were developed to calculate all of the acceleration components including a 4 degree of freedom dynamics model used to gain a greater understanding of the damaged solar array. The total error inherent to the data reduction procedure was calculated as a function of altitude and density considering contributions from ephemeris errors, errors in force coefficient, and instrument errors due to bias and digitization. Comparing the results from this procedure to the data of other MGS Teams has demonstrated that this procedure can quickly and accurately describe the density and vertical structure of the Martian upper atmosphere.

Cancro, George J.↗

A Self-Diagnostic System for the M6 Accelerometer

The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

Flanagan, Patrick M.↗

System Wide Joint Position Sensor Fault Tolerance in Robot Systems Using Cartesian Accelerometers

Joint position sensors are necessary for most robot control systems. A single position sensor failure in a normal robot system can greatly degrade performance. This paper presents a method to obtain position information from Cartesian accelerometers without integration. Depending on the number and location of the accelerometers. the proposed system can tolerate the loss of multiple position sensors. A solution technique suitable for real-time implementation is presented. Simulations were conducted using 5 triaxial accelerometers to recover from the loss of up to 4 joint position sensors on a 7 degree of freedom robot moving in general three dimensional space. The simulations show good estimation performance using non-ideal accelerometer measurements.

Aldridge, Hal A.↗

Bulk Micromachined 6H-SiC High-g Piezoresistive Accelerometer Fabricated and Tested

High-g accelerometers are needed in certain applications, such as in the study and analysis of high-g impact landings and projectiles. Also, these accelerometers must survive the high electromagnetic fields associated with the all-electric vehicle technology needed for aerospace applications. The choice of SiC is largely due to its excellent thermomechanical properties over conventional silicon-based accelerometers, whose material properties inhibit applicability in high electromagnetic radiation and high temperatures (>150 C) unless more complex and sometimes costly packaging schemes are adopted. This work was the outcome of a NASA Glenn Research Center summer internship program, in collaboration with Cornell University and the Munitions Directorate of the U.S. Air Force in Eglin, Florida. It aimed to provide the enabling technology infrastructure (modeling, fabrication, and validation) for the implementation of SiC accelerometers designed specifically for harsh environments.

Okojie, Robert S.↗

Should We Believe Atmospheric Temperatures Measured by Entry Accelerometers Traveling at "Slow" Near-Sonic Speeds?

Mars Pathfinder's Accelerometer instrument measured an unexpected and large temperature inversion between 10 and 20 kilometer altitude. Other instruments have failed to detect similar temperature inversions. I test whether this inversion is real or not by examining what changes have to be made to the assumptions in the accelerometer data processing to obtain a more "expected" temperature profile. Changes in derived temperature of up to 30K, or 15%, are necessary, which correspond to changes in derived density of up to 25% and changes in derived pressure of up to 10%. If the drag coefficient is changed to satisfy this, then instead of decreasing from 1.6 to 1.4 from 20 kilometers to 10 kilometers, the drag coefficient must increase from 1.6 to 1.8 instead. If winds are invoked, then speeds of 60 meters per second are necessary, four times greater than those predicted. Refinements to the equation of hydrostatic equilibrium modify the temperature profile by an order of magnitude less than the desired amount. Unrealistically large instrument drifts of 0.5-1.0 meters per square second are needed to adjust the temperature profile as desired. However, rotational contributions to the accelerations may have the necessary magnitude and direction to make this correction. Determining whether this hypothesis is true will require further study of the rigid body equations of motion, with detailed knowledge of the positions of all six accelerometers. The paradox concerning this inversion is not yet resolved. It is important to resolve it because the paradox has some startling implications. At one extreme, are temperature profiles derived from accelerometers inherently inaccurate by 20K or more? At the other extreme, are RS temperature profiles inaccurate by this same amount?

Withers, Paul↗

A Study into the Method of Precise Orbit Determination of a HEO Orbiter by GPS and Accelerometer

In the present day, orbit determination by Global Positioning System (GPS) is not unusual. Especially for low-cost small satellites, position determination by an on-board GPS receiver provides a cheap, reliable and precise method. However, the original purpose of GPS is for ground users, so the transmissions from all of the GPS satellites are directed toward the Earth s surface. Hence there are some restrictions for users above the GPS constellation to detect those signals. On the other hand, a desire for precise orbit determination for users in orbits higher than GPS constellation exists. For example, the next Japanese Very Long Baseline Interferometry (VLBI) mission "ASTRO-G" is trying to determine its orbit in an accuracy of a few centimeters at apogee. The use of GPS is essential for such ultra accurate orbit determination. This study aims to construct a method for precise orbit determination for such high orbit users, especially in High Elliptical Orbits (HEOs). There are several approaches for this objective. In this study, a hybrid method with GPS and an accelerometer is chosen. Basically, while the position cannot be determined by an on-board GPS receiver or other Range and Range Rate (RARR) method, all we can do to estimate the user satellite s position is to propagate the orbit along with the force model, which is not perfectly correct. However if it has an accelerometer (ACC), the coefficients of the air drag and the solar radiation pressure applied to the user satellite can be updated and then the propagation along with the "updated" force model can improve the fitting accuracy of the user satellite s orbit. In this study, it is assumed to use an accelerometer available in the present market. The effects by a bias error of an accelerometer will also be discussed in this paper.

Ikenaga, Toshinori↗

Method and apparatus for using an accelerometer signal to detect misfiring in an internal combustion engine

The method comprises operating an engine and collecting a real-time accelerometer signal from an accelerometer sensor. The real-time accelerometer signal is digitized and filtered to isolate data in a frequency range associated with combustion to produce a filtered signal data set. The filtered signal data set is integrated to produce an integrated signal data set, and misfire is detected by comparing the integrated signal data set with a predetermined reference data set associated with the same operating point. The apparatus is a control system for an engine that comprises an accelerometer sensor mounted to the engine; a look-up table in which is stored predetermined reference data sets, in association with predetermined operating conditions; and an electronic controller programmed to carry out the foregoing method.

33 ADVANCED PROPULSION SYSTEMS↗

Design and Process Considerations for a Tunneling Tip Accelerometer

In this paper, we discuss issues related to the fabrication of a bulk micromachined single axis accelerometer. The accelerometer is designed to have a full scale range of ten millig and a sensitivity of tens of nanog. During the process, three distinctly different die are fabricated. These are subsequently assembled using an ally bonding technique. During the bonding operation, electrical contacts are made between layers. The accelerometer is controlled by electrostatic force plates above and below the proof mass. The lower electrode has a dual role. In operation, it provides a necessary control electrode. When not in operation, it is used to clamp the proof mass and prevents its motion. Results of the fabrication process and initial testing of the clamping function are reported.

tunneling tip accelerometer, accelerometer fabrica↗

Piezoelectric accelerometers for ultrahigh temperature application

High temperature sensors are of major importance to aerospace and energy related industries. In this letter, a high temperature monolithic compression-mode piezoelectric accelerometer was fabricated using YCa{sub 4}O(BO{sub 3}){sub 3} (YCOB) single crystals. The performance of the sensor was tested as function of temperature up to 1000 deg. C and over a frequency range of 100-600 Hz. The accelerometer prototype was found to possess sensitivity of 2.4+-0.4 pC/g, across the measured temperature and frequency range, indicating a low temperature coefficient. Furthermore, the sensor exhibited good stability over an extended dwell time at 900 deg. C, demonstrating that YCOB piezoelectric accelerometers are promising candidates for high temperature sensing applications.

36 MATERIALS SCIENCE↗

Piezoelectric Shaker Development for High Frequency Calibration of Accelerometers

Calibration of vibration transducers requires sinusoidal motion over a wide frequency range with low distortion and low cross-axial motion. Piezoelectric shakers are well suited to generate such motion and are suitable for use with laser interferometric methods at frequencies of 3 kHz and above. An advantage of piezoelectric shakers is the higher achievable accelerations and displacement amplitudes as compared to electro-dynamic (ED) shakers. Typical commercial ED calibration shakers produce maximum accelerations from 100 m/s{sup 2} to 500 m/s{sup 2}. Very large ED shakers may produce somewhat higher accelerations but require large amplifiers and expensive cooling systems to dissipate heat. Due to the limitations in maximum accelerations by ED shakers at frequencies above 5 kHz, the amplitudes of the generated sinusoidal displacement are frequently below the resolution of laser interferometers used in primary calibration methods. This limits the usefulness of ED shakers in interferometric based calibrations at higher frequencies.Small piezoelectric shakers provide much higher acceleration and displacement amplitudes for frequencies above 5 kHz, making these shakers very useful for accelerometer calibrations employing laser interferometric measurements, as will be shown in this paper. These piezoelectric shakers have been developed and used at NIST for many years for high frequency calibration of accelerometers. This paper documents the construction and performance of a new version of these shakers developed at NIST for the calibration of accelerometers over the range of 3 kHz to 30 kHz and possibly higher. Examples of typical calibration results are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybridizing matter-wave and classical accelerometers

We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performance without any isolation platform. Second, a servo-lock of the DC component of the conventional sensor output signal by the atomic one realizes a hybrid sensor. This method paves the way for applications in geophysics and in inertial navigation as it overcomes the main limitation of atomic accelerometers, namely, the dead times between consecutive measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Tunneling Tip Protection for a Bulk Micromachined Accelerometer

Ultrasensitive accelerometers (on the order of 10-8 g) are needed by NASA for the measurement of orbital drag, and for seismic measurements on other planets. Silicon micromachined devices are attractive because they are light weight and smaller than conventional accelerometers. A method is presented here for fabricating a bulk micromachined accelerometer which incorporates a tunneling tip.

Accelerometer↗

The Impact of New Accelerometer Transplant Data (ACH) on GRACE Follow-On Along-Orbit Inter-Satellite Laser Ranging Observations and Monthly Time-Variable Gravity and Mascon Solutions

GRACE-D accelerometer data show significant bias jumps since one month after the launch of the GRACE Follow-On (GRACE-FO) satellites in May 2018, making them inapplicable for correcting GRACE-FO products for non-gravitational accelerations. The GRACE-FO Science Data System (SDS) compensated this issue by transplanting the GRACE-C accelerometer data toward that of GRACE-D. Recently, GRACE-FO SDS implemented an updated transplant method, used in the latest release of GRACE-FO data. Here, we examine the impact of updated accelerometer transplant data (ACH) on GRACE-FO measurements at all levels: (a) Level-1B inter-satellite laser ranging residuals measured along satellite orbit, (b) Level-2 time-variable gravity solutions from all SDS centers (JPL, CSR, and GFZ), and (c) Level-3 mascon solutions. We show that inter-satellite laser ranging residuals are modified at low frequencies below 1 mHz, affecting the along-orbit analysis of large-scale time-variable gravity signals. When mapped into monthly Level-2 spherical harmonic coefficients of geopotential, the low-frequency change in inter-satellite ranging residuals leads to substantial improvement of coefficients associated with resonant orders (i.e., 15, 30, 45, etc.) and C 30 . We also present an improved SLR-derived C 30 which significantly improves the agreement with updated GRACE-FO C 30 at seasonal and interannual timescales. Moreover, we demonstrate the noise reduction in mass change estimates from new GRACE-FO Level-2 data over oceans, Greenland, and Antarctica for all SDS solutions. GRACE-FO mascon solutions show a moderate change in the updated release. Our comprehensive analyses demonstrate high-quality estimates of non-gravitational accelerations by the updated transplant method, resulting in more accurate GRACE-FO time-variable gravity and mass change observations.

Laser ranging interferometer↗