A Self-Diagnostic System for the M6 Accelerometer

The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

Flanagan, Patrick M.↗

System Wide Joint Position Sensor Fault Tolerance in Robot Systems Using Cartesian Accelerometers

Joint position sensors are necessary for most robot control systems. A single position sensor failure in a normal robot system can greatly degrade performance. This paper presents a method to obtain position information from Cartesian accelerometers without integration. Depending on the number and location of the accelerometers. the proposed system can tolerate the loss of multiple position sensors. A solution technique suitable for real-time implementation is presented. Simulations were conducted using 5 triaxial accelerometers to recover from the loss of up to 4 joint position sensors on a 7 degree of freedom robot moving in general three dimensional space. The simulations show good estimation performance using non-ideal accelerometer measurements.

Aldridge, Hal A.↗

Bulk Micromachined 6H-SiC High-g Piezoresistive Accelerometer Fabricated and Tested

High-g accelerometers are needed in certain applications, such as in the study and analysis of high-g impact landings and projectiles. Also, these accelerometers must survive the high electromagnetic fields associated with the all-electric vehicle technology needed for aerospace applications. The choice of SiC is largely due to its excellent thermomechanical properties over conventional silicon-based accelerometers, whose material properties inhibit applicability in high electromagnetic radiation and high temperatures (>150 C) unless more complex and sometimes costly packaging schemes are adopted. This work was the outcome of a NASA Glenn Research Center summer internship program, in collaboration with Cornell University and the Munitions Directorate of the U.S. Air Force in Eglin, Florida. It aimed to provide the enabling technology infrastructure (modeling, fabrication, and validation) for the implementation of SiC accelerometers designed specifically for harsh environments.

Okojie, Robert S.↗

Should We Believe Atmospheric Temperatures Measured by Entry Accelerometers Traveling at "Slow" Near-Sonic Speeds?

Mars Pathfinder's Accelerometer instrument measured an unexpected and large temperature inversion between 10 and 20 kilometer altitude. Other instruments have failed to detect similar temperature inversions. I test whether this inversion is real or not by examining what changes have to be made to the assumptions in the accelerometer data processing to obtain a more "expected" temperature profile. Changes in derived temperature of up to 30K, or 15%, are necessary, which correspond to changes in derived density of up to 25% and changes in derived pressure of up to 10%. If the drag coefficient is changed to satisfy this, then instead of decreasing from 1.6 to 1.4 from 20 kilometers to 10 kilometers, the drag coefficient must increase from 1.6 to 1.8 instead. If winds are invoked, then speeds of 60 meters per second are necessary, four times greater than those predicted. Refinements to the equation of hydrostatic equilibrium modify the temperature profile by an order of magnitude less than the desired amount. Unrealistically large instrument drifts of 0.5-1.0 meters per square second are needed to adjust the temperature profile as desired. However, rotational contributions to the accelerations may have the necessary magnitude and direction to make this correction. Determining whether this hypothesis is true will require further study of the rigid body equations of motion, with detailed knowledge of the positions of all six accelerometers. The paradox concerning this inversion is not yet resolved. It is important to resolve it because the paradox has some startling implications. At one extreme, are temperature profiles derived from accelerometers inherently inaccurate by 20K or more? At the other extreme, are RS temperature profiles inaccurate by this same amount?

Withers, Paul↗

A Study into the Method of Precise Orbit Determination of a HEO Orbiter by GPS and Accelerometer

In the present day, orbit determination by Global Positioning System (GPS) is not unusual. Especially for low-cost small satellites, position determination by an on-board GPS receiver provides a cheap, reliable and precise method. However, the original purpose of GPS is for ground users, so the transmissions from all of the GPS satellites are directed toward the Earth s surface. Hence there are some restrictions for users above the GPS constellation to detect those signals. On the other hand, a desire for precise orbit determination for users in orbits higher than GPS constellation exists. For example, the next Japanese Very Long Baseline Interferometry (VLBI) mission "ASTRO-G" is trying to determine its orbit in an accuracy of a few centimeters at apogee. The use of GPS is essential for such ultra accurate orbit determination. This study aims to construct a method for precise orbit determination for such high orbit users, especially in High Elliptical Orbits (HEOs). There are several approaches for this objective. In this study, a hybrid method with GPS and an accelerometer is chosen. Basically, while the position cannot be determined by an on-board GPS receiver or other Range and Range Rate (RARR) method, all we can do to estimate the user satellite s position is to propagate the orbit along with the force model, which is not perfectly correct. However if it has an accelerometer (ACC), the coefficients of the air drag and the solar radiation pressure applied to the user satellite can be updated and then the propagation along with the "updated" force model can improve the fitting accuracy of the user satellite s orbit. In this study, it is assumed to use an accelerometer available in the present market. The effects by a bias error of an accelerometer will also be discussed in this paper.

Ikenaga, Toshinori↗

Design and Process Considerations for a Tunneling Tip Accelerometer

In this paper, we discuss issues related to the fabrication of a bulk micromachined single axis accelerometer. The accelerometer is designed to have a full scale range of ten millig and a sensitivity of tens of nanog. During the process, three distinctly different die are fabricated. These are subsequently assembled using an ally bonding technique. During the bonding operation, electrical contacts are made between layers. The accelerometer is controlled by electrostatic force plates above and below the proof mass. The lower electrode has a dual role. In operation, it provides a necessary control electrode. When not in operation, it is used to clamp the proof mass and prevents its motion. Results of the fabrication process and initial testing of the clamping function are reported.

tunneling tip accelerometer, accelerometer fabrica↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Tunneling Tip Protection for a Bulk Micromachined Accelerometer

Ultrasensitive accelerometers (on the order of 10-8 g) are needed by NASA for the measurement of orbital drag, and for seismic measurements on other planets. Silicon micromachined devices are attractive because they are light weight and smaller than conventional accelerometers. A method is presented here for fabricating a bulk micromachined accelerometer which incorporates a tunneling tip.

Accelerometer↗

The Impact of New Accelerometer Transplant Data (ACH) on GRACE Follow-On Along-Orbit Inter-Satellite Laser Ranging Observations and Monthly Time-Variable Gravity and Mascon Solutions

GRACE-D accelerometer data show significant bias jumps since one month after the launch of the GRACE Follow-On (GRACE-FO) satellites in May 2018, making them inapplicable for correcting GRACE-FO products for non-gravitational accelerations. The GRACE-FO Science Data System (SDS) compensated this issue by transplanting the GRACE-C accelerometer data toward that of GRACE-D. Recently, GRACE-FO SDS implemented an updated transplant method, used in the latest release of GRACE-FO data. Here, we examine the impact of updated accelerometer transplant data (ACH) on GRACE-FO measurements at all levels: (a) Level-1B inter-satellite laser ranging residuals measured along satellite orbit, (b) Level-2 time-variable gravity solutions from all SDS centers (JPL, CSR, and GFZ), and (c) Level-3 mascon solutions. We show that inter-satellite laser ranging residuals are modified at low frequencies below 1 mHz, affecting the along-orbit analysis of large-scale time-variable gravity signals. When mapped into monthly Level-2 spherical harmonic coefficients of geopotential, the low-frequency change in inter-satellite ranging residuals leads to substantial improvement of coefficients associated with resonant orders (i.e., 15, 30, 45, etc.) and C 30 . We also present an improved SLR-derived C 30 which significantly improves the agreement with updated GRACE-FO C 30 at seasonal and interannual timescales. Moreover, we demonstrate the noise reduction in mass change estimates from new GRACE-FO Level-2 data over oceans, Greenland, and Antarctica for all SDS solutions. GRACE-FO mascon solutions show a moderate change in the updated release. Our comprehensive analyses demonstrate high-quality estimates of non-gravitational accelerations by the updated transplant method, resulting in more accurate GRACE-FO time-variable gravity and mass change observations.

Laser ranging interferometer↗

Feasibility of an Accelerometer-Based Structural Health Monitoring System for the LANL Blast Tube

A modeling- and simulation-based study was conducted on the feasibility of implementing an accelerometer-based SHM system on the Los Alamos National Laboratory blast tube. A blast tube experiment was modeled using the Abaqus explicit finite element solver. A custom user subroutine was written to apply test-like pressure loading to the inside surface of the blast tube. The subroutine applies analytically defined pressure loads derived from tracer output taken from a Compressible Flow Computational Fluid Dynamics Solver model of the blast tube. Five unique versions of the model were created: an undamaged reference model at 65°F was used as the baseline and compared to equivalent models at 10°F and 100°F. These three models were compared to models with small damage at the reference temperature. The two types of damage considered were a radial (circumferential) crack in the main tube body and a longitudinal crack in the supports. Acceleration outputs were extracted from accelerometer bodies included in the model and were post processed using a variety of standard SHM techniques. Different potential features signaling failure were extracted and compared using statistical methods in the time and frequency domains. A method was identified that clearly shows that differences in structural response resulting from the modeled damage can be differentiated from the structural response resulting from changing environmental conditions. However, the amount of damage applied to create observable differences in the accelerometer data was so large that simpler methods of damage detection would be more cost effective in locating damage.

42 ENGINEERING↗

Tool enables proper mating of accelerometer and cable connector

Tool supports accelerometer in axial alignment with an accelerometer cable connector and permits tightening of the accelerometer to the cable connector with a torque wrench. This is done without damaging the components or permitting them to work loose under sustained, high-level vibrations.

Steed, C. N.↗

Description of the three axis low-g accelerometer package

The three axis low-g accelerometer package designed for use on the Space Processing Application Rocket (SPAR) Program is described. The package consists of the following major sections: (1) three Kearfott model 2412 accelerometers mounted in an orthogonal triad configuration on a temperature controlled, thermally isolated cube, (2) the accelerometer servoelectronics (printed circuit cards PC-6 through PC-12), and (3) the signal conditioner (printed circuit cards PC-15 and PC-16). The measurement range is 0 + or - 0.031 g with a quantization of 1.1 x 10 to the 7th power g. The package was flown successfully on six SPAR launches with the Black Brant booster. These flights provide approximately 300 s of free fall or zero-g environment.

Amalavage, A. J.↗

Electrofluidic accelerometer

Electrofluidic accelerometer senses components of linear and angular acceleration field. Typical application of such acceleration is as active controlling element in airplane autopilot. In contrast to conventional accelerometers, electrofluidic accelerometer is lightweight, small, inexpensive, rugged, and requires little power. It consists of two temperature sensors on opposite sides of heating element. Sensors detect temperature gradient created by acceleration field on fluid; when device is accelerated, gradient changes because of bouyant force on hotter (thus lighter) portion of fluid.

Hewes, D. E.↗

Accelerometer-enhanced orbit control near the sun-earth L1 libration point

Because the halo-orbit about the sun-earth L(1) libration point in which the satellite ISEE-3 was maintained for nearly four years is unstable, a loose control scheme about a precomputed nominal path was implemented which required orbit maneuvers approximately every three months. Execution errors were minimized by processing on-board accelerometer telemetry data in real time, and adjusting the maneuvers. Because spacecraft vibrations caused oscillations in the accelerometer data, smoothing techniques were applied to provide accurate estimates of the performance of pulse mode thrusters employed in the spin stabilization of the spacecraft. It has been found that the processed accelerometer data has an average error of only + or - 1.3 per cent.

Muhonen, D. P.↗

Accelerometer placement in active flutter suppression systems

An elementary study of the placement of accelerometers when used as sensors in active flutter suppression systems is presented. The model analyzed is a two-dimensional typical section with various combinations of leading- and trailing-edge controllers. The relationship between the control surface placement and accelerometer placement is examined. The results for the numerical examples presented show that accelerometers must be on the same side of the center of gravity as the control surface or right half-plane transmission zeros will arise. The detrimental effects of the right half-plane zeros are discussed in the context of linear-quadratic-regulator plus loop-transfer-recovered observer designs.

Liebst, Bradley S.↗

GRADIO three-axis electrostatic accelerometers

Dedicated accelerometers for satellite gravity gradiometry (GRADIO project) are described. The design profits from experience acquired with the CACTUS accelerometer payload of the satellite CASTOR-D5B and studies of highly accurate accelerometers for inertial navigation. The principle of operation, based on a three-axis electrostatic suspension of a cubic proof mass, is well suited for the measurements of accelerations less than 0.0001 m/sec/sec. A resolution better than 10 to the minus 11th power m/sec/sec/sq root Hz is expected.

Bernard, A.↗

Low-Cost Vertical Accelerometer For Aircraft

Self-aligning device measures vertical acceleration of aircraft but costs only small fraction of price of full inertial navigation system. Consists of accelerometer mounted vertically on inner gimbal of artificial horizon. Vertical accelerometer proves to be effective aid to Global Positioning System (GPS) navigation receivers in general-aviation aircraft and helicopters. Low-cost vertical accelerometer used to improve on vertical accuracy and reliability of GPS receiver alone. Also used to improve altitude accuracy for aircraft otherwise equipped with only baro-altimeter for altitude measurement.

Paielli, Russell A.↗

A new accelerometer recording system for shuttle use

Microgravity investigators are interested in enhancing the capabilities and improving the information return from accelerometers used in microgravity research. In addition to improving the accelerometer sensor, efforts should be directed towards using recent advances in microprocessor technology and system design techniques to improve sensor calibration and temperature compensation, online data display and analysis, and data reduction and information storage. Results from the above areas of investigation should be combined in an integrated design for a spaceflight microgravity accelerometer package.