Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerometers.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Modeling and Experimental Analysis of Piezoelectric Shakers for High-Frequency Calibration of Accelerometers

Piezoelectric shakers have been developed and used at the National Institute of Standards and Technology (NIST) for decades for high-frequency calibration of accelerometers. Recently, NIST researchers built new piezoelectric shakers in the hopes of reducing the uncertainties in the calibrations of accelerometers while extending the calibration frequency range beyond 20 kHz. The ability to build and measure piezoelectric shakers invites modeling of these systems in order to improve their design for increased performance, which includes a sinusoidal motion with lower distortion, lower cross-axial motion, and an increased frequency range. In this paper, we present a model of piezoelectric shakers and match it to experimental data. The equations of motion for all masses are solved along with the coupled state equations for the piezoelectric actuator. Finally, additional electrical elements like inductors, capacitors, and resistors are added to the piezoelectric actuator for matching of experimental and theoretical frequency responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and validation of a high-voltage levitation circuit for electrostatic accelerometers

A simple high-voltage circuit with a voltage range of 0 to 900 V and an open-loop bandwidth of 11 kHz is realized by using an operational amplifier and a MOSFET combination. The circuit is used for the levitation of a test mass of 71 g, suspended below the top-electrodes with a gap distance of 57 μm, so that the performance of an electrostatic accelerometer can be tested on the ground. The translation noise of the accelerometer, limited by seismic noise, is about 4 × 10{sup −8} m/s{sup 2}/Hz{sup 1/2} at 0.1 Hz, while the high-voltage coupling noise is one-order of magnitude lower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy improvement in a calibration test bench for accelerometers by a vision system

A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behavior if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shock margin testing of a one-axis MEMS accelerometer.

Shock testing was performed on a selected commercial-off-the-shelf - MicroElectroMechanical System (COTS-MEMS) accelerometer to determine the margin between the published absolute maximum rating for shock and the 'measured' level where failures are observed. The purpose of this testing is to provide baseline data for isolating failure mechanisms under shock and environmental loading in a representative device used or under consideration for use within systems and assemblies of the DOD/DOE weapons complex. The specific device chosen for this study was the AD22280 model of the ADXL78 MEMS Accelerometer manufactured by Analog Devices Inc. This study focuses only on the shock loading response of the device and provides the necessary data for adding influence of environmental exposure to the reliability of this class of devices. The published absolute maximum rating for acceleration in any axis was 4000 G for this device powered or unpowered. Results from this study showed first failures at 8000 G indicating a margin of error of two. Higher shock level testing indicated that an in-plane, but off-axis acceleration was more damaging than one in the sense direction.

47 OTHER INSTRUMENTATION↗

Calibrating Accelerometers Using an Electromagnetic Launcher

A Pulse Forming Network (PFN), Helical Electromagnetic Launcher (HEML), Command Module (CM), and Calibration Table (CT) were built and evaluated for the combined ability to calibrate an accelerometer. The PFN has a maximum stored energy of 19.25 kJ bank and is fired by a silicon controlled rectifier (SCR), with appropriate safety precautions. The HEML is constructed out of G-10 fiberglass and is designed to accelerate 600 grams to 10 meters per second. The CM is microcontroller based running Arduino Software. The CM has a keypad input and 7 segment outputs of the bank voltage and desired voltage. After entering a desired bank voltage, the CM controls the charge of the PFN. When the two voltages are equal it allows the fire button to send a pulse to the SCR to fire the PFN and in turn, the HEML. The HEML projectile's tip hits a target that is held by the CT. The CT consists of a table to hold the PFN and HEML, a vacuum chuck, air bearing, velocity meter and catch pot. The Target is held with the vacuum chuck awaiting impact. After impact, the air bearing allows the target to fall freely for the velocity meter to get an accurate reading. A known acceleration is determined from the known change in velocity of the target. Thus, if an accelerometer was attached to the target, the measured value can be compared to the known value.

47 OTHER INSTRUMENTATION↗

Unsupervised learning from three-component accelerometer data to monitor the spatiotemporal evolution of meso-scale hydraulic fractures

Enhanced geothermal systems can provide a substantial share of the global energy demand. There exist several hurdles in the engineering implementations of such geothermal systems. One such hurdle is the accurate monitoring of the fracture networks created in subsurface through hydraulic stimulation of these systems. Micro seismicity associated with the stimulation is the primary means to locate the event hypocenters for estimating the stimulated rock volume. Existing methods for location the hypocenters are restricted to only the highest amplitude impulsive signals that are simultaneously detected on several sensors. Consequently, a large portion (usually ~99%) of the measurements are left unused. In this paper, an unsupervised manifold-approximation followed by clustering of 3-component accelerometer data is used to analyze the seismicity recorded on a monitoring well. With this method, a larger portion of the measured signal is used for the monitoring of the hydraulic fracture network. We analyze the EGS Collab experiment 1 microseismic data, recorded at the Sanford Underground Research Facility, South Dakota. Using the data from a single three-component accelerometer, the polarization features viz. Azimuth, incidence, rectilinearity, and planarity are used as inputs for the unsupervised manifold approximation followed by clustering. Our study shows that density-based clusters in the projected 3D space correspond to distinct types of hydraulically fractured zones around the injection point. Finally, we show that the temporal evolution of these clusters can be used to track fracture creation and propagation.

58 GEOSCIENCES↗

SPE-5 Ground-Motion Prediction at Far-Field Geophone and Accelerometer Array Sites and SPE-5 Moment and Corner-Frequency Prediction

This report offers predictions for the SPE-5 ground-motion and accelerometer array sites. These predictions pertain to the waveform and spectral amplitude at certain geophone sites using Denny&Johnson source model and a source model derived from SPE data; waveform, peak velocity and peak acceleration at accelerometer sites using the SPE source model and the finite-difference simulation with LLNL 3D velocity model; and the SPE-5 moment and corner frequency.

47 OTHER INSTRUMENTATION↗

Measurement Uncertainty Analysis of an Accelerometer Calibration Using a POC Electromagnetic Launcher

A pulse forming network (PFN), helical electromagnetic launcher (HEML), command module (CM), and calibration table (CT) were built and evaluated for the combined ability to calibrate an accelerometer. The PFN has a maximum stored nergy of 19.25 kJ bank and is fired by a silicon controlled rectifier (SCR), with appropriate safety precautions. The HEML is constructed out of G-10 fiberglass reinforced epoxy and is designed to accelerate a mass of 600 grams to a velocity of 10 meters per second. The CM is microcontroller-based running Arduino Software. The CM has a keypad input and 7 segment outputs of the PFN voltage and desired charging voltage. After entering a desired PFN voltage, the CM controls the charging of the PFN. When the two voltages are equal it sends a pulse to the SCR to fire the PFN and in turn, the HEML. The HEML projectile’s tip hits a target that is held by the CT. The CT consists of a table to hold the PFN and HEML, a vacuum chuck, air bearing, velocimeter and catch pot. The target is held with the vacuum chuck awaiting impact. After impact, the air bearing allows the target to fall freely so that the velocimeter can accurately read. A known acceleration is determined from the known change in velocity of the target. Thus, if an accelerometer was attached to the target, the measured value can be compared to the known value.

47 OTHER INSTRUMENTATION↗

Design and initial characterization of a compact, ultra high vacuum compatible, low frequency, tilt accelerometer

A compact tilt accelerometer with high sensitivity at low frequency was designed to provide low frequency corrections for the feedback signal of the Advanced Laser Interferometer Gravitational Wave Observatory active seismic attenuation system. It has been developed using a Tungsten Carbide ceramic knife-edge hinge designed to avoid the mechanical 1/f noise believed to be intrinsic in polycrystalline metallic flexures. Design and construction details are presented; prototype data acquisition and control limitations are discussed. The instrument's characterization reported here shows that the hinge is compatible with being metal-hysteresis-free, and therefore also free of the 1/f noise generated by the dislocation Self-Organized Criticality in the metal. A tiltmeter of this kind will be effective to separate the ground tilt component from the signal of horizontal low frequency seismometers, and to correct the ill effects of microseismic tilt in advanced seismic attenuation systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of accelerometers for sensing combustion phasing of an advanced combustion engine

This paper evaluates the ability of accelerometers to detect combustion phasing of a single-cylinder air-cooled internal combustion engine undergoing homogeneous charge compression ignition. Metrics derived from the measured surface acceleration waveform, surface velocity, and the surface-specific kinetic energy were compared to the 50 per cent energy release location (CA50) on a cyclic basis for three different experimental test cases. The peak surface velocity location showed a robust ability to detect CA50 on a cyclic basis for short combustion durations. Finally, using a simple single-degree-of-freedom vibration model, it is shown the impulsive nature of the combustion load and the natural frequency of the engine structure governs when the peak velocity location will indeed robustly detect CA50 on a on a per-engine cycle basis.

33 ADVANCED PROPULSION SYSTEMS↗

A Feasibility Study on Use of an Accelerometer to Measure the Dynamic Forces in Turning

Metal cutting is a highly dynamic process that generates continuously varying forces. Measurement of these forces is essential to characterizing a cutting process and to fully utilize the machine tool. A force dynamometer is often used to measure these varying forces; however, it is limited by the natural frequency of the sensor and can sometimes be hard to set up on a machine. Therefore, this study aims to estimate the dynamic component of the cutting force using an accelerometer placed directly below the cutting edge. The placement of the sensor helps achieving better signal to noise ratio (S/N). The cutting tool is modelled as a single degree of freedom (SDOF) system relative to the workpiece and dynamic loads are experimentally simulated on it. The measured acceleration is numerically integrated to obtain velocity and deflection, which along with the natural frequency (ω n ) and damping ratio (ζ), is used to predict the dynamic load using the system equation. The dynamic forces tested over a wide range of frequencies, show good agreement with the data from simultaneous dynamometer measurement and the force estimated using the proposed method. The study shows the feasibility of this method in a real cutting scenario and the capability to apply it to a multi DOF system. One major limitation is the inability to capture the static or quasi-static component of the cutting force.

Cutting vibrations↗

Verifying Deep Reductions in the Nuclear Arsenals: Development and Demonstration of a Motion-detection Subsystem for a “Buddy Tag” Using Non-export Controlled Accelerometers

Future nuclear arms-control agreements may place numerical limits on items that are difficult to monitor with national technical means, even when complemented with onsite inspections. Such items could include small objects and mobile assets, such as non-deployed nuclear warheads and mobile missile launchers. Typically, this verification task can be addressed with unique identifiers, but standard tagging techniques may be unacceptable in this case due to host concerns about safety and intrusiveness. First proposed in the late 1980s and partially developed by Sandia National Laboratories in the early 1990s, the “Proximity Tag” or “Buddy Tag” concept seeks to overcome these concerns by separating the tag from the treaty accountable item itself. A buddy tag has two key elements: a tamper-indicating enclosure and a motion-detection system designed to detect illicit movements in a stand-down period. As part of this project, we have built a buddy-tag prototype for demonstration and evaluation purposes. This paper reviews the design choices and functionalities of the tag’s motion-detection subsystem.We pursue a modular approach for the tag’s hardware, built around an Arduino-class microcontroller and a non-export-controlled low-noise accelerometer, and use open-source algorithms for the motion-detection software. Finally, we discuss the results of an extensive experimental campaign involving both indoor and outdoor measurements assessing the performance of the tag under real-world environmental conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Modeling of Atom Interferometer Accelerometer

This report presents the theoretical effort to model and simulate the atom-interferometer accelerometer operating in a highly mobile environment. Multitudes of non-idealities may occur in such a rapidly-changing environment with a large acceleration whose amplitude and direction both change quickly. We studied the undesired effect of high mobility in the atom-interferometer accelerator in a detailed model and a simulator. The undesired effects include the atom cloud's movement during Raman pulses, the Doppler effect due to the relative movement between the atom-cloud and the supporting platform, the finite atom cloud temperature, and the lateral movement of the atom cloud. We present the relevant feed-forward mitigation strategies for each identified non-ideality to neutralize the impact and obtain accurate acceleration measurements.

43 PARTICLE ACCELERATORS↗

Accelerometer Modeling in the State-Space

Generically, accelerometers are sensors that measure the accelerating force applied to an object. Their operation is based on a simple mechanical system and D’Alembert’s force principle along with Newton’s laws of motion. This device is typically mounted to the body of the test object under investigation that is subjected to an accelerating force. The displacement of the seismic or “proof” mass due to the acceleration is sensed by an embedded component from which the acceleration is determined. Interestingly enough, the resulting the resulting mathematical relations governing the dynamical motion is based on the underlying physics, sensor materials, geometry and fabrication. Mathematically, the various designs satisfy the underlying Newtonian equations of motion, but their type and performance differ significantly.

42 ENGINEERING↗

TRUST Sensors in Environments: Accelerometers (SEA) Report

In FY21, a test body with dimensions 2x2x4 inch made from 6061-T6 aluminum with several threaded holes for mounting accelerometers was used for testing. The test body used in FY22 was a 250mm x 250mm x 5mm etched plate made from 6061-T6 aluminum. The testbody weights around 850 grams. A picture of the plate can be seen in Figure 2.1 below.

47 OTHER INSTRUMENTATION↗

Measuring Tree Properties and Responses Using Low-Cost Accelerometers

Trees play a crucial role in the water, carbon and nitrogen cycle on local, regional and global scales. Understanding the exchange of momentum, heat, water, and CO 2 between trees and the atmosphere is important to assess the impact of drought, deforestation and climate change. Unfortunately, ground measurements of tree properties such as mass and canopy interception of precipitation are often expensive or difficult due to challenging environments. This paper aims to demonstrate the concept of using robust and affordable accelerometers to measure tree properties and responses. Tree sway is dependent on mass, canopy structure, drag coefficient, and wind forcing. By measuring tree acceleration, we can relate the tree motion to external forcing (e.g., wind, precipitation and related canopy interception) and tree physical properties (e.g., mass, elasticity). Using five months of acceleration data of 19 trees in the Brazilian Amazon, we show that the frequency spectrum of tree sway is related to mass, canopy interception of precipitation, and canopy–atmosphere turbulent exchange.

59 BASIC BIOLOGICAL SCIENCES↗

High sensitivity single-axis MEMS accelerometer with bilateral flexures

A microelectromechanical systems (MEMS) accelerometer that has high sensitivity to motion along the z axis is discussed. The device includes two symmetrical sets of bilateral, diametrically opposed high aspect ratio flexures that tether a movable proof mass to the frame of the device. The flexures are designed in such a way as to restrict movement of the proof mass along the x and y axes but readily allow motion along the z axis. More specifically, when the device experiences an acceleration along the x or y axes, the proof mass is restricted from moving because some of the bilateral, diametrically opposed flexures are in compression and others are in tension.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗