Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Hardware-in-the-Loop Experimental Testbed Using Air Conditioners for Grid Balancing

Driven by the need to offset the variability of renewable generation on the grid, development of load control is a highly active field of research. However, practical use of residential loads for grid balancing remains rare, in part due to the cost of communicating with large numbers of small loads and also the limited experimentation done so far to demonstrate reliable operation. To establish a basis for the safe and reliable use of fleets of compressor loads as distributed energy resources, we constructed an experimental testbed in a laboratory, so that load coordination schemes could be tested at extreme conditions. Here, this experimental testbed was used to tune a simulation testbed to which it was then linked, thereby augmenting the effective size of the fleet. Modeling of the system was done both to demonstrate the experimental testbed's behavior and also to understand how to tune the behavior of each load. Implementing this testbed has enabled rapid turnaround of experiments on various load control algorithms, and year-round testing without the constraints and limitations arising in seasonal field tests with real houses. Experimental results show the practical feasibility of an ensemble of small loads contributing to grid balancing.

Air Conditioners↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

Modeling Water Vapor Transport at Liquid/Membrane Interfaces for Applications in Liquid Desiccant Air Conditioners (CRADA CRD-17-679 Final Report)

Conventional compressor-based cooling has undergone incremental changes over the past 100 years. Further improvements in efficiency require evermore complex systems, especially under humid conditions. Meso-porous membranes offer unique opportunities for efficient humidity control in buildings using an absorbent desiccant solution, but membranes are not designed or optimized for this purpose. This project will use molecular dynamic simulations to determine optimal membrane properties for these air conditioning applications, focusing on the membrane properties at the membrane/liquid/air interface. Optimal membrane designs will enable smaller, more durable, and less expensive designs of these membrane air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefit FOA FY2015 - Solid State Magnetocaloric Air Conditioner (Final Report)

The active magnetic refrigeration (AMR) cycle holds great promise to reduce energy consumption of space cooling and heating. It is estimated that it could achieve up to 25% improvement in energy efficiency over conventional vapor compression systems. Prototypes have been built and demonstrated the working principles and energy benefits of the technology. These prototypes however were of low specific cooling power, defined as cooling power obtainable from unit mass of magnetocaloric materials (MCM). Specific cooling power is inversely proportional to the cost of the system. Therefore, for the magnetocaloric technology to be commercially viable, the specific cooling power must be increased. To increase the specific cooling power, for any MCM, the frequency of operation must increase. However, the maximum frequency that an AMR can operate at is limited by the residence time that is required to transfer heat in and out of the regenerator during the cold and got blows. This time length is dependent on the thermal conductivity of the heat transfer medium. The higher the thermal conductivity of the heat transfer medium, the faster heat can be transferred between the medium and the MCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Benefit Analysis for Air Conditioner in Tunisia

This is the second report from Lawrence Berkeley National Laboratory (LBNL) in support of developing a minimum energy performance standards (MEPS) program for ACs in Tunisia. This report builds upon a market and regulatory assessment that characterized Tunisia’s market and regulations for ACs (LBNL 2022). The current report is organized in the style of the technical support documents (TSDs) produced for U.S. appliance efficiency standards and comprises the following: a description of our analytical framework (Section 1) followed by several analyses of the context for and impacts of adopting a MEPS for ACs in Tunisia: an energy-use analysis (Section 2), engineering analysis (Section 3), life-cycle cost (LCC) analysis (Section 4), and national impact analysis (Section 5). The report concludes with policy recommendations (Section 6).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Low-Cost Minisplit Heat Pump Connection System

This project was funded by SCE's Emerging Technologies Program, and evaluates the feasibility of a connection system that can pave the path to accelerated, cost-effective adoption of high-efficiency Minisplit Heat Pump (MSHP) systems. This report details the characterization of this connection system and a heat pump enabled with this technology in a laboratory setting, and assesses the energy and cost impact applicable to residential buildings in SCE service territory. The energy and economic analysis leverages NREL's ResStock TM modeling approach based on the EnergyPlus ® hourly simulation platform. The connection system can be incorporated into existing MSHP architectures. This reduces installation time from 10 to 20 man hours to approximately one hour or less, dramatically lowering total installation costs without adversely impacting heat pump performance. This report characterizes the connection system's leakage performance while connected and disconnected, as well as leakage over several connection/disconnection cycles, commensurate with manufacturer specifications for the individual components. The connector was incorporated into an off-the-shelf MSHP. Performance was compared to an identical unmodified heat pump. The connector had no impact on performance. Large-scale hourly energy simulations were performed for 22,574 homes across 15 counties in SCE service territory. The analysis was performed using baseline assumptions about the penetrations of window air conditioners (~18%) and six upgrade scenarios for these air conditioners. All scenarios assumed 100% adoption of the Connector-Supported Heat Pump (CSHP) in place of window air conditioners: MSHPs at Seasonal Energy Efficiency Ratio (SEER) 17, 25, and 33, and CSHPs at SEER 17, 25, and 33. Results show the increased adoption of high-efficiency heat pumps can result in up to 29% air conditioning energy savings for homes with window air conditioners.

42 ENGINEERING↗

Modeling and Experiments on a Dedicated Outdoor Air System Using Liquid Desiccant Heat and Mass Exchangers

Liquid desiccants can provide efficient dehumidification but have yet to see widespread adoption. Most systems studied previously use natural gas-combustion to heat and regenerate the desiccant, and a central chiller plant or cooling tower for removing the heat of absorption. Here we present modeling and experimental results on a novel packaged air conditioner integrating liquid-desiccant heat and mass exchangers with a vapor compression cycle. The packaged system does not need cold or hot water from a central plant or cooling tower and is suitable for rooftop unit air conditioners. The system uses the evaporator to cool the liquid desiccant that is absorbing moisture from the air, and the condenser to heat the liquid desiccant to regenerate it. Efficiency is improved by reducing the load on the evaporator for a given supply-air dewpoint. This paper presents the measured dehumidification efficiency for a 10- ton packaged air conditioner, focusing on dehumidifying ventilation air. The paper also presents a numerical model to predict the outlet conditions and dehumidification efficiency, which we compare with the measured data.

air conditioning↗

The Effect of Power Electronic Loads on Western Interconnection Stability

The prevalence of power electronics in the bulk power system is increasing rapidly in both the generation and consumption of electricity. This work focuses on the effect of changing load composition - specifically the transition from single phase air conditioner motors to power electronics backed air conditioners - on power system stability. Various transmission and generation contingency events for the Western Interconnection were simulated using Positive Sequence Load Flow software and planning models from the Western Electricity Coordinating Council. In general, an increased proportion of power electronic load leads to more instability. For some specific faults resulting in fault-induced delayed voltage recovery, transitioning to higher proportions of power electronic loads helps expedite system recovery. These results demonstrate that load composition should be examined in conjunction with generation composition when evaluating system stability.

FIDVR↗

Highly-Efficient Microemulsion-Based Absorption Chillers for HVAC Application

Air conditioning is a necessity to achieve a comfortable, habitable home or office for many places in US. However, vapor compression air conditioners are largely made with chlorofluorocarbon refrigerants, or CFCs, which create problems for a world grappling with climate change. In addition, vapor compression air conditioners are driven by electricity. Cooling and heating represent one-third of building electrical energy consumption in US. An absorption chiller is different to vapor compression chillers or air conditioners because it doesn’t use conventional refrigerants, like CFC. Instead, they may use water as the refrigerant which is mixed with safe and nontoxic absorbents. The research performed in this project advanced the understanding of absorption cooling technology and its application in HVAC. Various technologies were explored to improve the performance of the desorber and absorber components in the absorption chillers.

42 ENGINEERING↗

Automatic Fault Detection & Diagnostics: Residential Market Analysis

This report provides an overview of the market potential for automated fault detection and diagnostics (AFDD) in the residential sector, focusing on embedded AFDD in central air conditioners (CAC) and air-source heat pumps (ASHP) as well as the use of smart diagnostic tools to ensure quality installation of CAC/ASHP equipment. The contents include background on AFDD, stakeholder engagement efforts, a technology assessment of AFDD and smart diagnostic tools, residential CAC and ASHP market trends, a characterization of the CAC and ASHP installed base, a synopsis of utility provider programs, and market barriers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cold-Climate Packaged Heat Pumps - Resistance is Futile

The U.S. currently has a large market for room/zonal space conditioning equipment focused primarily on cooling, namely packaged terminal air conditioners (PTACs), packaged terminal heat pumps (PTHPs), and room air conditioners. This equipment largely relies on electric resistance for heating, particularly when outdoor temperatures fall to 40°F or below, presenting a compelling opportunity for energy savings and carbon reductions from reverse cycle heating. This paper provides an overview of cold climate packaged heat pump technologies in the market capable of high output down to outdoor temperatures of 5°F and identifies the technological and market barriers to adoption. For state-of-the-art cold climate packaged heat pumps sold in the retrofit market, defrost meltwater management is the principal barrier to implementation. An energy use analysis is conducted on state-of-the-art cold climate packaged heat pumps for heating and cooling loads by building vintage and climate zone. Potential solutions to defrost meltwater are proposed and modeled for their impact on heating energy efficiency. A national impact assessment estimates the aggregate energy savings and carbon reductions if cold climate packaged heat pumps were to replace existing PTACs and PTHPs in the U.S. building stock. A national, two-track approach is proposed for increasing market adoption in the replacement and new construction markets.

ACEEE Summer Study, cold climate, heat pumps, ccph↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗

The impact of behavioral and geographic heterogeneity on residential-sector carbon abatement costs

Analyses of monetary and emissions savings from residential efficiency upgrades usually neglect behavioral differences between consumers. Variations in behavior are frequently large: 13% of the U.S. population sets thermostats for cooling at 20 °C (68 °F) or lower and 15% at 25.5 °C (78 °F) or higher. Efficiency analyses should account for behavioral heterogeneity as well as variations in climate and housing characteristics. We model energy and economic savings of efficiency upgrades for U.S. single-family detached houses, accounting for differences in thermostat settings, climate zone, fuel prices, and home characteristics. We consider five efficiency interventions: wall insulation, attic insulation, air sealing, high-efficiency furnaces, and high-efficiency air conditioners. Energy and economic savings vary widely by consumer; the average net present value for wall insulation is $3,020 United States Dollar (USD), but considering heterogeneity, it has a 10th percentile value of -$231 and 90th percentile value of $5,000. Neglecting heterogeneity, technology upgrades can be prioritized from lower to higher carbon abatement costs: air conditioners, wall insulation, furnace, air sealing, and attic insulation. Accounting for heterogeneity reorders this prioritization, and consumer-specific conditions affect mitigation costs such that technologies are mixed in with one another and are no longer arranged one after another. These results indicate that interventions to improve efficiency should consider differences between consumers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Material properties of aqueous potassium acetate solutions for use in liquid desiccant air conditioning

We present thermophysical properties of aqueous potassium acetate solutions relevant to their application as a liquid desiccant in air-conditioning systems. Liquid desiccant air conditioners could provide up to 80% energy savings compared to high-efficiency vapor compression air conditioners. However, the commonly used liquid desiccants, particularly chloride salt solutions, are highly corrosive. This precludes the use of metallic components, necessitating specialized plastics and thereby driving up cost, weight, and limiting operational temperature and pressure ranges. Potassium acetate has been identified as a less corrosive alternative, potentially enabling broader material compatibility in LDAC components. In this study we systematically measured and modelled key thermophysical properties of KAc solutions density, vapor pressure, viscosity, specific heat capacity, phase behavior, and diffusion coefficient across a range of concentrations (10 - 70wt%) and temperatures. For instance, KAc exhibits a vapor pressure of 3.1 kPa at 50wt% and 40degrees C, demonstrating dehumidification capability comparable to chloride salts. By providing an extended dataset and associated models, this work advances the understanding needed to design energy-efficient, corrosion mitigating LDAC system.

36 MATERIALS SCIENCE↗