Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM SWITCHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ion beam etching dependence of spin-orbit torque memory devices with switching current densities reduced by Hf interlayers

We report on the fabrication of nanoscale, three-terminal in-plane spin–orbit torque switching devices with low switching current densities. Critical parameters in the fabrication process, including the ion beam etching angle and time, were optimized to avoid fabrication defects and improve device yield. Measurements of the magnetic field and current-induced switching behavior of the tunnel junctions demonstrate a sensitivity to the nanopillar aspect ratio, which dictates the nanopillars’ anisotropy and thermal stability. Additionally, we show that the current density required for switching can be reduced and the device thermal stability increased by inserting Hf interlayers into the heterostructure. Micromagnetic simulations are generally consistent with the experimentally observed switching behavior, suggesting an increase in the interfacial perpendicular anisotropy at the CoFeB/MgO interface and the reduction in the Dzyaloshinskii–Moriya interaction at the W/CoFeB interface by the Hf interlayers.

36 MATERIALS SCIENCE↗

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High power actively Q-switched downhole LIBS analysis systems

An actively Q-switched laser induced breakdown spectroscopy (LIBS) probe, utilizing an optical fiber, a pump beam transmitted through the optical fiber, a coupler, and a lens for collimating the pump beam. The actively Q-switched laser, coupled to a sensor which provides information to a computer that controls a high voltage pulser providing a pulse to a Pockels cell located within the laser which can selectively cause the laser to pulse, resulting in high energy pulses and a second lens for focusing the output pulse such that it creates a plasma or spark. The light from the spark is captured and directed back through an optical system to remote equipment for elemental and/or molecular analysis.

McIntyre, Dustin Langdon↗

Experimental comparison of pyranometer, reflectometer, and spectrophotometer methods for the measurement of roofing product albedo

Albedo (solar reflectance) can be measured outdoors with a pyranometer or indoors with a hemispherical reflectometer or a spectrophotometer. The current study evaluates these methods and their applicability to roofing materials by measuring and comparing the ASTM E1918 (pyranometer), non-ASTM E1918A (alternative pyranometer), ASTM C1549 (reflectometer), and E903 (spectrophotometer) albedos of 10 roofing products, including three single-ply membranes, one asphalt shingle, three roofing aggregates, and three high-profile tiles. It uses full-size (4 m × 4 m) assemblies in the E1918 and E1918A trials; corrects the E1918 albedos to remove shadow and background errors; and evaluates C1549 and E903 albedos with two different irradiance spectra, one global horizontal and the other beam normal. E1918A albedos matched E1918 corrected (E1918_cor) albedos to within 0.036. Furthermore, agreement between C1549 air mass 1 global horizontal (C1549_G1) albedo and E1918_cor albedo was within 0.015 for membrane and shingle coupons, and within 0.031 for aggregates, though the uncertainty in the latter agreement was up to 0.043. After minor corrections, C1549_G1 albedos of flat or slightly convex tile chips were 0.032–0.052 higher than the E1918_cor albedos of their corresponding high-profile tile assemblies because high-profile surfaces have concavities. Switching to the beam-normal albedo C1549_1.5E increased the C1549 albedos of the 10 tested products by 0.004–0.054, with the largest increases (C1549_1.5E – C1549_G1) accruing to spectrally selective cool colors. Using C1549_1.5E albedo to characterize a chip of a cool-colored tile compounded the error induced by representing a high-profile surface by a flat or slightly convex specimen.

14 SOLAR ENERGY↗

Electron-beam–controlled deflection of near-infrared laser in semiconductor plasma

A timing method for experiments on the interaction of a near-infrared laser and an ultra-relativistic electron beam via a semiconductor plasma switch is experimentally validated. As an intermediate medium, a thin Si plate is excited by the energetic, intense electron beam to produce a semiconductor plasma, which in turn deflects counter-colliding laser light having 1 μm wavelength. An electron beam of sub-nC charge sufficiently induces the needed electron number density gradient of 1×10 20 cm -3 per tens of μm length at the interaction point. Demonstration during an inverse Compton scattering experiment by a counter-colliding electron beam of 300 pC and 70 MeV with an Nd: YAG laser at a wavelength of 1 μm is reported here.

43 PARTICLE ACCELERATORS↗

Practical Considerations for Understanding Surface Reaction Mechanisms Involved in Heterogeneous Catalysis

Acquiring useful knowledge about the active site(s) of a catalyst, nature of reactant–catalyst interactions, nature of reactive intermediates, rate-determining step, reaction rate orders that affect various process parameters, and reaction mechanism as a whole is exceedingly challenging. This is especially true in the case of heterogeneous catalysts due to the complexity of the nature of surface active sites and their nonstatic behavior. Here, we present our perspective on differentiating between various surface reaction mechanisms in light of pioneering studies by leaders in the field, with the aim of clarifying some of the confusion associated with these complex mechanisms, especially the Eley–Rideal mechanism. Using bibliometric analysis, we identify and discuss the following four reactions that most commonly invoke the Eley– Rideal mechanism: H 2 activation, CO oxidation, esterification of alcohols by acids, and selective catalytic reduction (SCR) of NO x with NH 3 . Our analysis of studies utilizing well-suited experimental and computational methodologies for differentiating surface reaction mechanisms suggests that the above-mentioned four reactions do not occur via the Eley–Rideal mechanism. Instead, each reaction occurs via the Langmuir–Hinshelwood mechanism with nonidealities present. Lastly, we highlight practical considerations regarding select experimental (characterization methods and differential kinetics) and computational modeling that we believe can provide useful insights to accurately discern between the various possible reaction mechanisms in heterogeneous catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source

The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.

36 MATERIALS SCIENCE↗

Lasing dynamics of diode-pumped Yb – Er laser with a passive Q switch exposed to high-power external light

The temporal dynamics of diode-side-pumped Yb – Er laser, with a passive Co{sup 2+} : MgAl{sub 2}O{sub 4} Q switch illuminated by a light beam (total fluence of 0.15 – 0.16 J cm{sup −2}) from a semiconductor pulsed module, is investigated. It is shown that, using this external illumination, one can change the lasing onset delay and the time jitter ΔT{sub gi}. The dependence of ΔT{sub gi} on the interval between the instant of switching the illumination module on and the lasing peak position t{sub i} has a minimum at |t{sub i}| ≈ 10 μs. The decrease in ΔT{sub gi} with a change in |t{sub i}| from 90 to 10 μs indicates that instant of lasing peak occurrence for the Yb – Er laser is partially controlled by the pulse from the highly stable semiconductor module. If |t{sub i}| < 10 μs, the enhanced luminescence fluence in the cavity of Yb – Er laser exceeds 0.16 J cm{sup −2}; the light beam from the module does not affect much the lasing process in the ytterbium – erbium laser; and, as a consequence, the time jitter recovers the initial value. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resistive switching properties of monolayer h-BN atomristors with different electrodes

Resistive switching properties based on molecular beam epitaxy-grown monolayer hexagonal boron nitride (h-BN) atomristors are studied by using metal insulator metal configurations with different electrode materials. Au/monolayer h-BN/Ni devices demonstrate a forming-free bipolar resistive switching (BRS) behavior, a good endurance with up to 97 cycles at a high compliance current of 100 mA, an average on/off ratio of 10 3 , and a low set/reset voltage variability. Metal/monolayer h-BN/graphite/Co devices exhibit self-compliant current BRS characteristics. Both metal/h-BN/Ni and metal/h-BN/graphite/Co devices show the coexistence of BRS, unipolar resistive switching (URS), and nonvolatile threshold switching (TH) modes. The formation of conductive filaments is attributed to the diffusion and trapping of metal ions on the defect sites driven by the electric field, while the rupture is driven by the electric field in BRS and by Joule heating in URS and TH modes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Some considerations about switching BPM channels

Switching the signals from two BPM buttons between the two channels was suggested for the LEReC BPMs. In this note we discuss how such a switching can help with determining the true position of the beam. We also describe the setup of the switching scheme for the BPMs in the LEReC cooling sections (CSs).

43 PARTICLE ACCELERATORS↗

Fielding and analyzing performance of a prototype high voltage output gas switch for Saturn

Timing spread between the thirty-six Saturn modules affects peak electrical power delivered to the Bremsstrahlung diode and can affect vacuum power flow and impedance behavior of the load. To reduce the module spread, a new megavolt gas-insulated closing switch was developed employing design techniques developed for the Z-machine laser triggered switches while retaining Saturn’s simpler electrical triggering. Two modules were temporarily outfitted with the new switches and used separately into local resistive loads (instead of the usual Saturn electron beam load). A reliable operating point and switch time jitter at that point were the goals of the experiments. The target switch reliability is less than one pre-fire in one thousand switch-shots, and a timing standard deviation of 4 nanoseconds. The switches were able to meet both requirements but the number of tests at the chosen point are limited.

43 PARTICLE ACCELERATORS↗

Contact-free reversible switching of improper ferroelectric domains by electron and ion irradiation

Focused ion beam (FIB) and scanning electron microscopy (SEM) are used to reversibly switch improper ferroelectric domains in the hexagonal manganite ErMnO 3 . Surface charging is achieved by local ion (positive charging) and electron (positive and negative charging) irradiation, which allows controlled polarization switching without the need for electrical contacts. Polarization cycling reveals that the domain walls tend to return to the equilibrium configuration obtained in the as-grown state. The response of sub-surface domains is studied by FIB cross-sectioning, enabling imaging in the direction perpendicular to the applied electric field. The results clarify how the polarization reversal in hexagonal manganites progresses at the level of domains, resolving both domain wall movements and the nucleation and growth of new domains. Our FIB-SEM based switching approach is applicable to all ferroelectrics where a sufficiently large electric field can be built up via surface charging, facilitating contact-free high-resolution studies of the domain and domain wall response to electric fields in 3D.

36 MATERIALS SCIENCE↗

3D-Printed mmWave Quasi-Holographic Antenna for 2-D Beamforming

This paper presents the design and manufacturing of a novel 2D-scanning antenna that integrates a 3D-printed Rotman lens with a quasi-holographic leaky-wave antenna (HLWA). The proposed design achieved beam-scanning capabilities by leveraging the beamforming of the Rotman lens and the high-gain directive properties of the quasi-HLWA. The Rotman lens (RL) enables beam steering in the elevation plane by switching between input ports. The quasi-HLWA, designed using holographic principles, achieves frequency-controlled beam scanning in the azimuth plane. The entire antenna structure was fabricated using additive manufacturing with an Ink1092 substrate and silver ink for the conductive traces. This approach provides greater control over material placement and design freedom compared to traditional methods. A 25° transmission linear substrate taper was used to ensure good impedance matching between the Rotman lens and the quasi-HLWA, allowing greater gain while maintaining a good scanning range. The experimental results validate the 2D scanning capability of the proposed antenna. The antenna system provides coverage from −54° to 54° in the elevation θ plane and −28° to 28° in the azimuth plane ϕ , with a maximum measured gain of 21.3 dBi at 28 GHz with an average radiation efficiency η=60 %. The fabricated prototype was tested, and the performance was in good agreement with the simulated performance.

Rotman lens↗

Vacuum system design, construction, and operation for the Cornell High Energy Synchrotron Source upgrade

During the summer and fall 2018, the Cornell High Energy Synchrotron Source (CHESS), underwent an upgrade that recast the facility as primarily a low emittance X-ray source. The upgrade replaced one sixth of the Cornell Electron Storage Ring (CESR) with six double-bend achromats, featuring four novel CHESS Compact Undulator (CCU) insertion devices, and switched CESR to single particle beam operation. At the time of this writing, the upgraded storage ring has achieved the CHESS-U design goal of operating with 200 mA of positron current at 6.0 GeV beam energy. Additionally, seven out of eleven CHESS-U beamlines are currently in X-ray user operation. The construction and the commissioning of the new section of the CESR accelerator required novel solutions to design, fabrication, and vacuum system operations. Significant design considerations and efforts were made to minimize X-ray ‘dark-time’, returning to operation less than 1 year. This paper describes the important milestones of the process, the solutions implemented, and the present status of CHESS-U.

43 PARTICLE ACCELERATORS↗

A Threshold Helium Leakage Detection Switch with Ultra Low Power Operation

Detecting helium leakage is important in many applications, such as in dry cask nuclear waste storage systems. This work develops a helium detection system based on the relative permittivity (dielectric constant) difference between air and helium. This difference changes the status of an electrostatic microelectromechanical system (MEMS) switch. The switch is a capacitive-based device and requires a very negligible amount of power. Exciting the switch’s electrical resonance enhances the MEMS switch sensitivity to detect low helium concentration. This work simulates two different MEMS switch configurations: a cantilever-based MEMS modeled as a single-degree-freedom model and a clamped-clamped beam MEMS molded using the COMSOL Multiphysics finite-element software. While both configurations demonstrate the switch’s simple operation concept, the clamped-clamped beam was selected for detailed parametric characterization due to its comprehensive modeling approach. The beam detects at least 5% helium concentration levels when excited at 3.8 MHz, near electrical resonance. The switch performance decreases at lower excitation frequencies or increases the circuit resistance. The MEMS sensor detection level was relatively immune to beam thickness and parasitic capacitance changes. However, higher parasitic capacitance increases the switch’s susceptibility to errors, fluctuations, and uncertainties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wehnelt photoemission in an ultrafast electron microscope: Stability and usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a custom 100 μm diameter LaB 6 source with a graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a custom 200 μm diameter polycrystalline Ta source. For each cathode type and configuration, including the Ni Wehnelt aperture, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Furthermore, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of the optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB 6 thermionic emission, as well as to on-axis photoemission [the heretofore conventional approach to ultrafast electron microscopy (UEM) in thermionic-based instruments]. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be ±1% (one standard deviation from the mean) for 70 min (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition were also found to be within ±1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Positive spin Hall magnetoresistance in single-crystalline Pt/CoO(001) bilayers

Here, the spin Hall magnetoresistance (SMR) effect in single-crystalline Pt/CoO(001) bilayers has been systematically investigated. X-ray magnetic linear dichroism measurements prove that CoO antiferromagnetic (AFM) spins can be switched into the direction orthogonal to the applied field. We find the SMR signal is comprised of two components related to either the switching of CoO AFM Néel order or the applied strong field effect. Both SMR components show a “positive” angular dependence with $R_{∥} > R_{⊥}$, while $R_{∥} (R_{⊥})$ is defined as the resistance with the applied in-plane field parallel (perpendicular) to the current. The observed positive SMR is mainly attributed to the uncompensated spins at the Pt/CoO interface, instead of the CoO AFM spins. Our study may attract a great deal of interest to understand the complicated SMR effect in AFM spintronics materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Combining Laue diffraction with Bragg coherent diffraction imaging at 34-ID-C

Measurement modalities in Bragg coherent diffraction imaging (BCDI) rely on finding a signal from a single nanoscale crystal object which satisfies the Bragg condition among a large number of arbitrarily oriented nanocrystals. However, even when the signal from a single Bragg reflection with ( hkl ) Miller indices is found, the crystallographic axes on the retrieved three-dimensional (3D) image of the crystal remain unknown, and thus localizing in reciprocal space other Bragg reflections becomes time-consuming or requires good knowledge of the orientation of the crystal. Here, the commissioning of a movable double-bounce Si (111) monochromator at the 34-ID-C endstation of the Advanced Photon Source is reported, which aims at delivering multi-reflection BCDI as a standard tool in a single beamline instrument. The new instrument enables, through rapid switching from monochromatic to broadband (pink) beam, the use of Laue diffraction to determine crystal orientation. With a proper orientation matrix determined for the lattice, one can measure coherent diffraction patterns near multiple Bragg peaks, thus providing sufficient information to image the full strain tensor in 3D. The design, concept of operation, the developed procedures for indexing Laue patterns, and automated measuring of Bragg coherent diffraction data from multiple reflections of the same nanocrystal are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗