Gas detectors for x-ray lasers

We have developed different types of photodetectors that are based on the photoionization of a gas at a low target density. The almost transparent devices were optimized and tested for online photon diagnostics at current and future x-ray free-electron laser facilities on a shot-to-shot basis with a temporal resolution of better than 100 ns. Characterization and calibration measurements were performed in the laboratory of the Physikalisch-Technische Bundesanstalt at the electron storage ring BESSY II in Berlin. As a result, measurement uncertainties of better than 10% for the photon-pulse energy and below 20 {mu}m for the photon-beam position were achieved at the Free-electron LASer in Hamburg (FLASH). An upgrade for the detection of hard x-rays was tested at the Sub-Picosecond Photon Source in Stanford.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-accuracy X-ray detector calibration based on cryogenic radiometry

Cryogenic electrical substitution radiometers (ESRs) are absolute thermal detectors, based on the equivalence of electrical power and radiant power. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2 %, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity is used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3 %. For some silicon photodiodes, the photocurrent is not linear with the incident radiant power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface acoustic wave propagation in graphene film

Surface acoustic wave (SAW) propagation in a graphene film on the surface of piezoelectric crystals was studied at the BESSY II synchrotron radiation source. Talbot effect enabled the visualization of the SAW propagation on the crystal surface with the graphene film in a real time mode, and high-resolution x-ray diffraction permitted the determination of the SAW amplitude in the graphene/piezoelectric crystal system. The influence of the SAW on the electrical properties of the graphene film was examined. It was shown that the changing of the SAW amplitude enables controlling the magnitude and direction of current in graphene film on the surface of piezoelectric crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

At-wavelength metrology facility for soft X-ray reflection optics

A new Optics Beamline coupled to a versatile UHV reflectometer is successfully operating at BESSY-II. It is used to carry out at-wavelength characterization and calibration of in-house produced gratings and novel nano-optical devices as well as mirrors and multilayer systems in the UV and XUV spectral region. This paper presents most recent commissioning data of the beamline and shows their correlation with initial beamline design calculations. Special attention is paid to beamline key parameters which determine the quality of the measurements such as high-order suppression and stray light behavior. The facility is open to user operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant Raman scattering of polarized and unpolarized x-ray radiation from Mg, Al, and Si

The x-ray resonant Raman scattering (RRS) effect of polarized and unpolarized radiation in the vicinity of the 1s absorption threshold of low-Z elements such as magnesium, aluminum, and silicon is investigated. For the polarized and tunable exciting x-ray radiation the plane grating monochromator (PGM) beam line at the PTB laboratory in the BESSY II synchrotron radiation facility was employed, while unpolarized x-ray beams were induced by 1-MeV proton beam irradiation on various pure thick targets. For the latter case, a novel proton-induced x-ray fluorescence scattering chamber was designed and installed at the Tandem accelerator laboratory of the Institute of Nuclear Physics at N.C.S.R. 'Demokritos'. The total RRS cross sections deduced from both independent excitation modes were found to be in a good agreement, within the experimental uncertainties. The predictions of the existing theory with respect to the dependence of the RRS to the incident beam polarization state is calculated and discussed with respect to the experimental results.

36 MATERIALS SCIENCE↗

Resonant and Near-Threshold Photoionization Cross Sections of Fe{sup 14+}

Photoionization (PI) of Fe{sup 14+} in the range from 450 to 1100 eV was measured at the BESSY II storage ring using an electron beam ion trap achieving high target-ion area densities of 10{sup 10} cm{sup -2}. Photoabsorption by this ion is observed in astrophysical spectra and plasmas, but until now cross sections and resonance energies could only be provided by calculations. We reach a resolving power E/{Delta}E of at least 6500, outstanding in the present energy range, which enables benchmarking and improving the most advanced theories for PI of ions in high charge states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fully automated, fixed exit, in vacuum double-multilayer monochromator for synchrotron-based hard X-ray micro-imaging applications

We present a double multilayer monochromator (DMM) design which has been realized for the BAMline(BESSY-II light source, Germany) as well as in an updated version for the TopoTomo beamline (ANKA light source. Germany)[1-4]. The latter contains two pairs of multilayer stripes in order to avoid absorption edges of the coating material. For both DMMs, the second multilayer offers a meridional bending option for beam compression to increase the available photon flux density. Each multilayer mirror is equipped with a vertical stage for height adjustments allowing for compensation of varying incoming beam heights and giving a certain flexibility choosing the offset. The second multilayer can be moved in the beam direction in order to cover the full energy range available. Furthermore, a white beam option is available.

43 PARTICLE ACCELERATORS↗

Dimensional Control of Micro Components with Synchrotron Computed Tomography

An advantage of Computed Tomography (CT) is the coordinate measurement capability of small inner structures, which are not accessible with classical measurement techniques. Using the advantages of synchrotron radiation CT measurements of parts with sizes of a few millimeters are performed at BAMline of BESSY II and are expected to be used as references for further dimensional measurements with micro CT. Previous investigations were focused on external gears, which are accessible with standard Coordinate Measurement Machines (CMMs). To obtain information about the accuracy of dimensional measurements of internal gears with CT, reference data have been measured by a tactile-optical CMM. This information is used to evaluate the performance of the CT. In addition to the first results for the evaluation of internal gear flanks, new measurements of different gear materials (steel and zirconium dioxide) will be presented. For functional evaluation, gear flanks are a matter of particular interest. Form deviations are analyzed with respect to the different gear materials to establish CT measurements as technology in the field of quality assurance and to compare the different manufacturing processes.

07 ISOTOPE AND RADIATION SOURCES↗

Survey and adjustment methods applied on an 11 axes high performance reflectometer for synchrotron radiation

At BESSY-II a new UV-and XUV optics beamline [1] has recently been setup with an in-house developed versatile reflectometer [2], [3], [4] for at-wavelength metrology on reflective and diffractive optical elements up to 4 kg mass. High precision measurements of the reflection and polarization properties are feasible by a 360° azimuthal rotation of the sample around the beam of light, where samples can be adjusted reproducibly with a novel UHV-Tripod within arc sec and μm precision. The azimuthal rotation requires an extremely high precision adjustment of the goniometer axis with respect to the incident light beam. Here we describe sophisticated methods with which we achieve nearly perfect agreement of the azimuthal rotation axis and the synchrotron beam in the 30 arc sec range. By using geodetic instruments (lasertracker, theodolite, autocollimator) the quality of the reflectometer UHV-mechanics has been characterized with respect to stiffness and radial run out with highest precision [5].

43 PARTICLE ACCELERATORS↗

TXM-NEXAFS of TiO{sub 2}-Based Nanostructures

In this work, electronic properties of individual TiO{sub x}-pristine nanoribbons (NR) prepared by hydrothermal treatment of anatase TiO{sub 2} micro-particles were studied using the HZB transmission x-ray microscope (TXM) at the BESSY II undulator beamline U41-FSGM. NEXAFS is ideally suited to study TiO{sub 2}-based materials because both the O K-edge and Ti L-edge features are very sensitive to the local bonding environment, providing diagnostic information about the crystal structures and oxidation states of various forms of titanium oxides and sub-oxides. TXM-NEXAFS combines full-field x-ray microscopy with spectroscopy, allowing the study of the electronic structure of individual nanostructures with spatial resolution better than 25 nm and a spectral resolution of up to E/{Delta}E = 10000. The typical image field in TXM-NEXAFS measurements is about 10 {mu}mx10 {mu}m, which is large compared to the individual nanoparticle. Therefore, one image stack already contains statistically significant data. In addition, the directional electric field vector (E-bar) of the x-rays can be used as a 'search tool' for the direction of chemical bonds of the atom selected by its absorption edge.

36 MATERIALS SCIENCE↗

Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes

The energy resolved efficiency of two bolometer detector prototypes for ITER with 4 channels each and absorber thicknesses of 4.5 μm and 12.5 μm, respectively, has been calibrated in a broad spectral range from 1.46 eV up to 25 keV. The calibration in the energy range above 3 eV was performed against previously calibrated silicon photodiodes using monochromatized synchrotron radiation provided by five different beamlines of Physikalische Technische Bundesanstalt at the electron storage rings BESSY II and Metrology Light Source in Berlin. For the measurements in the visible range, a setup was realised using monochromatized halogen lamp radiation and a calibrated laser power meter as reference. The measurements clearly demonstrate that the efficiency of the bolometer prototype detectors in the range from 50 eV up to ≈6 keV is close to unity; at a photon energy of 20 keV the bolometer with the thick absorber detects 80% of the photons, the one with the thin absorber about 50%. This indicates that the detectors will be well capable of measuring the plasma radiation expected from the standard ITER scenario. However, a minimum absorber thickness will be required for the high temperatures in the central plasma. At 11.56 keV, the sharp Pt-L{sub 3} absorption edge allowed to cross-check the absorber thickness by fitting the measured efficiency to the theoretically expected absorption of X-rays in a homogeneous Pt-layer. Furthermore, below 50 eV the efficiency first follows the losses due to reflectance expected for Pt, but below 10 eV it is reduced further by a factor of 2 for the thick absorber and a factor of 4 for the thin absorber. Most probably, the different histories in production, storage, and operation led to varying surface conditions and additional loss channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a New Generation of Optical Slope Measuring Profiler

A collaboration including all DOE synchrotron laboratories and industrial vendors of X-ray optics, and with active participation of the HBZ-BESSY-II optics group, has been established to work together on a new slope measuring profiler - the Optical Slope Measuring System (OSMS). The slope measurement accuracy of the instrument is expected to be <50 nrad for the current and future metrology of X-ray optics for the next generation of light sources. The goals were to solidify a design that meets the needs of mirror specifications and also be affordable, and to create a common specification for fabrication of a multi-functional translation/scanning (MFTS) system for the OSMS. This was accomplished by two collaborative meetings at the ALS (March 26, 2010) and at the APS (May 6, 2010).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dielectric function and optical properties of quaternary AlInGaN alloys

The optical properties of quaternary Al{sub x}In{sub y}Ga{sub 1-x-y}N alloy films with 0.16<x<0.64 and 0.02<y<0.13 are presented. The (0001)-oriented AlInGaN layers were grown by metal-organic vapor phase epitaxy on thick GaN/sapphire templates. High-resolution x-ray diffraction measurements revealed the pseudomorphic growth of the AlInGaN films on the GaN buffer. Rutherford backscattering and wavelength-dispersive x-ray spectroscopy analysis were used in order to determine the composition of the alloys. The ordinary dielectric function (DF) of the AlInGaN samples was determined in the range of 1-10 eV by spectroscopic ellipsometry (SE) at room temperature (synchrotron radiation: BESSY II). The sharp onset of the imaginary part of the DF defines the direct absorption edge of the alloys. At higher photon energies, pronounced peaks are observed in the DF indicating a promising optical quality of the material. These features are correlated to the critical points of the band structure (van Hove singularities). An analytical model, which permits us to accurately describe the dielectric function (or optical constants) in the range of 1-10 eV, is also presented. The band-gap and high-energy interband transition values are obtained by fitting the experimental DF with the analytical model. The strain influence on the bandgap is evaluated by using the kxp formalism. Furthermore, an empirical expression is proposed which allows us to calculate the AlInGaN band-gap and high-energy inter-band transitions in the whole compositional range (x, y). The band-gap values obtained from the empirical expression are in good agreement with both the calculated ab initio and the experimental values determined by SE.

36 MATERIALS SCIENCE↗

Néel walls between tailored parallel-stripe domains in IrMn/CoFe exchange bias layers

Tailored parallel-stripe magnetic domains with antiparallel magnetizations in adjacent domains along the long stripe axis have been fabricated in an IrMn/CoFe Exchange Bias thin film system by 10 keV He{sup +}-ion bombardment induced magnetic patterning. Domain walls between these domains are of Néel type and asymmetric as they separate domains of different anisotropies. X-ray magnetic circular dichroism asymmetry images were obtained by x-ray photoelectron emission microscopy at the Co/Fe L{sub 3} edges at the synchrotron radiation source BESSY II. They revealed Néel-wall tail widths of 1 μm in agreement with the results of a model that was modified in order to describe such walls. Similarly obtained domain core widths show a discrepancy to values estimated from the model, but could be explained by experimental broadening. The rotation senses in adjacent walls were determined, yielding unwinding domain walls with non-interacting walls in this layer system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of the size and shape of the scanning aperture in autocollimator-based deflectometric profilometers

Deflectometric profilometers based on industrial electronic autocollimators (ACs), as the ELCOMAT-3000, have become indispensable tools for precision form measurements of optical surfaces. A growing number of labs at synchrotron and free electron laser x-ray facilities are going for BESSY-II NOM-like versions of the AC-based profilometers. These tools have proven capable of characterizing state-of-the-art aspherical x-ray optics with an accuracy on the level of 100 nrad (root-mean-square) over the spatial frequency range limited by the size of the aperture used in the profilometer. Normally, a round aperture with a diameter of about 2.5 mm is used. Previous investigations have shown that with the optimally aligned 2.5-mm aperture, the spatial resolution of a NOM-like profilometer corresponding to the first zero-crossing of the optical transform function (OTF) is ~1.2 mm. In this paper, we investigate the performance of an AC ELCOMAT-3000 for a slope profilometer with different aperture sizes and shapes. The results of angular calibration of the AC equipped with circular and rectangular apertures placed at different distances from the AC are discussed. The calibration was performed at the Physikalisch-Technische Bundesanstalt using the original experimental arrangements, also discussed in the paper. The OTF measurements with the specially developed test sample with chirped surface slope profiles were performed at the Advanced Light Source X-Ray Optics Laboratory (XROL) in application to a new optical surface measuring system under development at the XROL. In the OTF measurements, we have shown that application of a rectangular aperture with dimensions of 1.5 mm × 3 mm improves the spatial resolution in the tangential direction by a factor of ~1.4 compared to that of the standard circular aperture of 2.5-mm diameter. We postulate that the conclusions of our investigations are crucial for reaching fundamental metrological limits in deflectometric profilometry utilizing state-of-the-art electronic autocollimators.

47 OTHER INSTRUMENTATION↗

Facilities for macromolecular crystallography at the Helmholtz-Zentrum Berlin

Three macromolecular crystallography (MX) beamlines at the Helmholtz-Zentrum Berlin (HZB) are available for the regional, national and international structural biology user community. The state-of-the-art synchrotron beamlines for MX BL14.1, BL14.2 and BL14.3 are located within the low-[beta] section of the BESSY II electron storage ring. All beamlines are fed from a superconducting 7 T wavelength-shifter insertion device. BL14.1 and BL14.2 are energy tunable in the range 5-16 keV, while BL14.3 is a fixed-energy side station operated at 13.8 keV. All beamlines are equipped with CCD detectors. BL14.1 and BL14.2 are in regular user operation providing about 200 beam days per year and about 600 user shifts to approximately 50 research groups across Europe. BL14.3 has initially been used as a test facility and was brought into regular user mode operation during the year 2010. BL14.1 has recently been upgraded with a microdiffractometer including a mini-[kappa] goniometer and an automated sample changer. Other user facilities include office space adjacent to the beamlines, a sample preparation laboratory, a biology laboratory (safety level 1) and high-end computing resources. In this article the instrumentation of the beamlines is described, and a summary of the experimental possibilities of the beamlines and the provided ancillary equipment for the user community is given.

43 PARTICLE ACCELERATORS↗

Determination of preferential molecular orientation in porphyrin-fullerene dyad ZnDHD6ee monolayers by the X-ray standing-wave method and X-ray reflectometry

Monolayers of porphyrin-fullerene dyad molecules with zinc atoms incorporated into the porphyrin ring (ZnDHD6ee) on the surface of aqueous subphase and on Si substrates have been investigated by the X-ray standing-wave method and X-ray reflectometry. The experiments have been performed under laboratory conditions and on synchrotron radiation sources (KMC-2 station of BESSY II (Berlin) and Langmuir station at the National Research Centre 'Kurchatov Institute'). Depth distributions of Zn atoms and electron density in the monolayer film are calculated. On the basis of the analysis of these distributions, it is concluded that ZnDHD6ee dyad molecules in monolayers have preferential orientation. The data obtained indicate that the molecules in monolayer film retain their orientation when the monolayer is transferred from a liquid subphase surface onto a solid substrate.

36 MATERIALS SCIENCE↗

A new benchmark of soft X-ray transition energies of $$\mathrm {Ne}$$, $$\mathrm {CO}_2$$, and $$\mathrm {SF}_6$$: paving a pathway towards ppm accuracy

Abstract A key requirement for the correct interpretation of high-resolution X-ray spectra is that transition energies are known with high accuracy and precision. We investigate the K-shell features of $$\mathrm {Ne}$$ Ne , $$\mathrm {CO}_2$$ CO 2 , and $$\mathrm {SF}_6$$ SF 6 gases, by measuring their photo ion-yield spectra at the BESSY II synchrotron facility simultaneously with the 1s– n p fluorescence emission of He-like ions produced in the Polar-X EBIT. Accurate ab initio calculations of transitions in these ions provide the basis of the calibration. While the $$\mathrm {CO}_2$$ CO 2 result agrees well with previous measurements, the $$\mathrm {SF}_6$$ SF 6 spectrum appears shifted by $$\sim $$ ∼ 0.5 eV, about twice the uncertainty of the earlier results. Our result for $$\mathrm {Ne}$$ Ne shows a large departure from earlier results, but may suffer from larger systematic effects than our other measurements. The molecular spectra agree well with our results of time-dependent density functional theory. We find that the statistical uncertainty allows calibrations in the desired range of 1–10 meV, however, systematic contributions still limit the uncertainty to $${\sim }$$ ∼ 40–100 meV, mainly due to the temporal stability of the monochromator energy scale. Combining our absolute calibration technique with a relative energy calibration technique such as photoelectron energy spectroscopy will be necessary to realize its full potential of achieving uncertainties as low as 1–10 meV. Graphical abstract

74 ATOMIC AND MOLECULAR PHYSICS↗