Search NASA⌕ Search

SEARCH · Search NASA

Results for “BLOOD PLASMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Method of high-precision microsampled blood and plasma mass densitometry

The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

Hinghofer-Szalkay, H.↗

Inhibitory Effects of Vanadium-Binding Proteins Purified from the Sea Squirt Halocynthia roretzi on Adipogenesis in 3T3-L1 Adipocytes

The inhibitory effects of vanadium-binding proteins (VBPs) from the blood plasma and the intestine of sea squirt on adipogenesis in 3T3-L1 adipocytes were examined. 3T3L-1 cells treated with VBP {sub blood plasma} decreased markedly the lipid content in maturing pre-adipocytes in a dose-dependent manner, whereas VBP {sub intestine} did not show significant effects on lipid accumulation. Both VBPs did not have significant effect on cell viability. In order to demonstrate the anti-adipogenic effects of VBP {sub blood plasma}, the expressions of several adipogenic transcription factors and enzymes were investigated by Reverse Transcriptase-Polymerase Chain Reaction. VBP {sub blood plasma} down-regulated the expressions of transcription factors; PPAR-γ, C/EBP-α, SREBP1, and FAS, but did not have significant effects on the expressions of lipolytic enzymes; HSL and LPL. Both the crude and purified VBPs significantly increased the mRNA levels of Wnt10b, FZ1, LRP6, and β-catenin, while decreased the expression of GSK-3β. Hence, VBP {sub blood plasma} inhibited adipogenesis by activating WNT/β-catenin pathway via the activation of Wnt10b. Based on the findings, VBP {sub blood plasma} decreased lipid accumulation which was mediated by decreasing adipogenesis, not by lipolysis. Therefore, VBP {sub blood plasma} could be used to treat obesity.

60 APPLIED LIFE SCIENCES↗

Large-Scale Interlaboratory DI-FT-ICR MS Comparability Study Employing Various Systems

We report ultra-high resolution mass spectrometry (UHR-MS) coupled with direct infusion (DI) electrospray ionization offers a fast solution for accurate untargeted profiling. Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers have been shown to produce a wealth of insights into complex chemical systems because they enable unambiguous molecular formula assignment even if the vast majority of signals is of unknown identity. Inter-laboratory comparisons are required to apply this type of instrumentation in quality control (for food industry or pharmaceutics), large-scale environmental studies or clinical diagnostics. Extended comparisons employing different FT-ICR MS instruments with qualitative direct infusion analysis are scarce since the majority of detected compounds cannot be quantified. The extent to which observations can be reproduced by different laboratories remains unknown. We set up a preliminary study which encompassed a set of seventeen laboratories around the globe, diverse in instrumental characteristics and applications, to analyze the same sets of extracts from commercially available standard human blood plasma and Standard Reference Material (SRM) for blood plasma (SRM1950), which were delivered at different dilutions or spiked with different concentrations of pesticides. The aim of this study was to assess the extent to which the outputs of differently tuned FTICR mass spectrometers, with different technical specifications, are comparable for setting the frames of a future DI-FT-ICR MS ring trial. We concluded that a cluster of five laboratories, with diverse instrumental characteristics showed comparable and representative performance across all experiments, setting a reference to be used in a future ring trial on blood plasma.

47 OTHER INSTRUMENTATION↗

Association between As and Cu renal cortex accumulation and physiological and histological alterations after chronic arsenic intake

Arsenic (As) is one of the most abundant hazards in the environment and it is a human carcinogen. Related to excretory functions, the kidneys in humans, animal models or naturally exposed fauna, are target organs for As accumulation and deleterious effects. Previous studies carried out using X-ray fluorescence spectrometry by synchrotron radiation (SR-{mu}XRF) showed a high concentration of As in the renal cortex of chronically exposed rats, suggesting that this is a suitable model for studies on renal As accumulation. This accumulation was accompanied by a significant increase in copper (Cu) concentration. The present study focused on the localization of these elements in the renal cortex and their correlation with physiological and histological As-related renal effects. Experiments were performed on nine male Wistar rats, divided into three experimental groups. Two groups received 100 {mu}g/ml sodium arsenite in drinking water for 60 and 120 consecutive days, respectively. The control group received water without sodium arsenite (<50 ppb As). For histological analysis, 5-{mu}m-thick sections of kidneys were stained with hematoxylin and eosin. Biochemical analyses were used to determine concentrations of plasma urea and creatinine. The As and Cu mapping were carried out by SR-{mu}XRF using a collimated white synchrotron spectrum (300 {mu}mx300 {mu}m) on kidney slices (2 mm thick) showing As and Cu co-distribution in the renal cortex. Then, renal cortical slices (100 {mu}m thick) were scanned with a focused white synchrotron spectrum (30 {mu}mx30 {mu}m). Peri-glomerular accumulation of As and Cu at 60 and 120 days was found. The effects of 60 days of arsenic consumption were seen in a decreased Bowman's space as well as a decreased plasma blood urea nitrogen (BUN)/creatinine ratio. Major deleterious effects; however, were seen on tubules at 120 days of exposition. This study supports the hypothesis that tubular accumulation of As-Cu may have some bearing on the arsenic-associated nephrotoxicological process.

60 APPLIED LIFE SCIENCES↗

Multiplex detection and identification of viral, bacterial, and protozoan pathogens in human blood and plasma using an expanded high-density resequencing microarray platform

Introduction: Nucleic acid tests for blood donor screening have improved the safety of the blood supply; however, increasing numbers of emerging pathogen tests are burdensome. Multiplex testing platforms are a potential solution. Methods: The Blood Borne Pathogen Resequencing Microarray Expanded (BBP-RMAv.2) can perform multiplex detection and identification of 80 viruses, bacteria and parasites. This study evaluated pathogen detection in human blood or plasma. Samples spiked with selected pathogens, each with one of 6 viruses, 2 bacteria and 5 protozoans were tested on this platform. The nucleic acids were extracted, amplified using multiplexed sets of primers, and hybridized to a microarray. The reported sequences were aligned to a database to identify the pathogen. To directly compare the microarray to an emerging molecular approach, the amplified nucleic acids were also submitted to nanopore next generation sequencing (NGS). Results: The BBP-RMAv.2 detected viral pathogens at a concentration as low as 100 copies/ml and a range of concentrations from 1,000 to 100,000 copies/ml for all the spiked pathogens. Coded specimens were identified correctly demonstrating the effectiveness of the platform. The nanopore sequencing correctly identified most samples and the results of the two platforms were compared. Discussion: These results indicated that the BBP-RMAv.2 could be employed for multiplex detection with potential for use in blood safety or disease diagnosis. The NGS was nearly as effective at identifying pathogens in blood and performed better than BBP-RMAv.2 at identifying pathogen-negative samples.

59 BASIC BIOLOGICAL SCIENCES↗

MicroRNAs as disease progression biomarkers and therapeutic targets in experimental autoimmune encephalomyelitis model of multiple sclerosis

Multiple sclerosis is an autoimmune neurodegenerative disease of the central nervous system characterized by pronounced inflammatory infiltrates entering the brain, spinal cord and optic nerve leading to demyelination. Focal demyelination is associated with relapsing-remitting multiple sclerosis, while progressive forms of the disease show axonal degeneration and neuronal loss. The tests currently used in the clinical diagnosis and management of multiple sclerosis have limitations due to specificity and sensitivity. MicroRNAs (miRNAs) are dysregulated in many diseases and disorders including demyelinating and neuroinflammatory diseases. A review of recent studies with the experimental autoimmune encephalomyelitis animal model (mostly female mice 6–12 weeks of age) has confirmed miRNAs as biomarkers of experimental autoimmune encephalomyelitis disease and importantly at the pre-onset (asymptomatic) stage when assessed in blood plasma and urine exosomes, and spinal cord tissue. The expression of certain miRNAs was also dysregulated at the onset and peak of disease in blood plasma and urine exosomes, brain and spinal cord tissue, and at the post-peak (chronic) stage of experimental autoimmune encephalomyelitis disease in spinal cord tissue. Therapies using miRNA mimics or inhibitors were found to delay the induction and alleviate the severity of experimental autoimmune encephalomyelitis disease. Interestingly, experimental autoimmune encephalomyelitis disease severity was reduced by overexpression of miR-146a, miR-23b, miR-497, miR-26a, and miR-20b, or by suppression of miR-182, miR-181c, miR-223, miR-155, and miR873. Further studies are warranted on determining more fully miRNA profiles in blood plasma and urine exosomes of experimental autoimmune encephalomyelitis animals since they could serve as biomarkers of asymptomatic multiple sclerosis and disease course. Additionally, studies should be performed with male mice of a similar age, and with aged male and female mice.

59 BASIC BIOLOGICAL SCIENCES↗

Determining blood and plasma volumes using bioelectrical response spectroscopy

We hypothesized that an electric field (inductance) produced by charged blood components passing through the many branches of arteries and veins could assess total blood volume (TBV) or plasma volume (PV). Individual (N = 29) electrical circuits (inductors, two resistors, and a capacitor) were determined from bioelectrical response spectroscopy (BERS) using a Hewlett Packard 4284A Precision LCR Meter. Inductance, capacitance, and resistance from the circuits of 19 subjects modeled TBV (sum of PV and computed red cell volume) and PV (based on 125I-albumin). Each model (N = 10, cross validation group) had good validity based on 1) mean differences (-2.3 to 1.5%) between the methods that were not significant and less than the propagated errors (+/- 5.2% for TBV and PV), 2) high correlations (r > 0.92) with low SEE (< 7.7%) between dilution and BERS assessments, and 3) Bland-Altman pairwise comparisons that indicated "clinical equivalency" between the methods. Given the limitation of this study (10 validity subjects), we concluded that BERS models accurately assessed TBV and PV. Further evaluations of the models' validities are needed before they are used in clinical or research settings.

NASA Discipline Number 00-00↗

IgY14 and SuperMix immunoaffinity separations coupled with liquid chromatography-mass spectrometry for human plasma proteomic biomarker discovery

Interest in the application of advanced proteomics technologies to human blood plasma- or serum-based clinical samples for the purpose of discovering disease biomarkers continues to grow; however, the enormous dynamic range of protein concentrations in these types of samples (often >10 orders of magnitude) represents a significant analytical challenge, particularly for detecting low-abundance candidate biomarkers. In response, immunoaffinity separation methods for depleting multiple high- and moderate-abundance proteins have become key tools for enriching low-abundance proteins and enhancing detection of these proteins in plasma proteomics. Herein, we describe IgY14 and tandem IgY14-Supermix separation methods for removing 14 high-abundance and up to 60 moderate-abundance proteins, respectively, from human blood plasma and highlight their utility when combined with liquid chromatography-tandem mass spectrometry for interrogating the human plasma proteome.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of the Utility of the Oral Fluid and Plasma Proteome for Hydrocodone Usage

Non-medical use and abuse of prescription opioids is a growing problem in both the civilian and military communities, with minimal technologies for detecting hydrocodone use. This study explored the proteomic changes that occur in the oral fluid and blood plasma following controlled hydrocodone administration in twenty subjects. The global proteomic profile was determined for samples taken at four time points per subject of pre-exposure and 4, 6, or 168 hours post-exposure. The oral fluid samples analyzed herein provided greater differentiation between “baseline” and “response” time points than was observed with blood plasma, at least partially due to significant person-to-person variability in the plasma proteome. A total of 399 proteins were identified from oral fluid samples, and the abundance of 102 of those proteins was determined to be significantly different upon metabolism of hydrocodone (4 and 6 hour time points) as compared to baseline levels in the oral fluid (pre-dose and 168 hour). This is the first, to our knowledge, assessment of the oral fluid and blood plasma proteome following hydrocodone administration, which demonstrates the potential of oral fluid as a non-invasive sample that may reveal features of hydrocodone or other opioid use and/or misuse.

Kaiser, Brooke LD↗

An Exploratory Study Into the Role of Dynamic Contrast-Enhanced Magnetic Resonance Imaging or Perfusion Computed Tomography for Detection of Intratumoral Hypoxia in Head-and-Neck Cancer

Purpose: Hypoxia in patients with head-and-neck cancer (HNC) is well established and known to cause radiation resistance and treatment failure in the management of HNC. This study examines the role of parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and perfusion computed tomography (CT) as surrogate markers of intratumoral hypoxia, defined by using the exogenous marker of hypoxia pimonidazole and the endogenous marker carbonic anhydrase 9 (CA9). Methods and Materials: Patients with HNC underwent preoperative DCE-MRI, perfusion CT, and pimonidazole infusion. Imaging parameters were correlated with pimonidazole and CA9 staining. The strength of correlations was tested by using a two-tailed Spearman's rank correlation coefficient. Results: Twenty-three regions of interest were analyzed from the 7 patients who completed the DCE-MRI studies. A number of statistically significant correlations were seen between DCE-MRI parameters (volume transfer between blood plasma and extracellular extravascular space [EES], volume of EES, rate constant between EES and blood plasma, time at arrival of contrast inflow, time to peak, average gradient, and time to onset) and areas with a pimonidazole score of 4. In the case of CA9 staining, only a weak correlation was shown with wash-in rate. There were no significant correlations between perfusion CT parameters and pimonidazole staining or CA9 expression. Conclusion: Intratumoral hypoxia in patients with HNC may be predicted by using DCE-MRI; however, perfusion CT requires further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.

Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.

Burton, R. R.↗

Improving low-level plasma protein mass spectrometry-based detection for candidate biomarker discovery and validation

Methods. To improve the detection of low abundance protein candidate biomarker discovery and validation, particularly in complex biological fluids such as blood plasma, increased sensitivity is desired using mass spectrometry (MS)-based instrumentation. A key current limitation on the sensitivity of electrospray ionization (ESI) MS is due to the fact that many sample molecules in solution are never ionized, and the vast majority of the ions that are created are lost during transmission from atmospheric pressure to the low pressure region of the mass analyzer. Two key technologies, multi-nanoelectrospray emitters and the electrodynamic ion funnel have recently been developed and refined at Pacific Northwest National Laboratory (PNNL) to greatly improve the ionization and transmission efficiency of ESI MS based analyses. Multi-emitter based ESI enables the flow from a single source (typically a liquid chromatography [LC] column) to be divided among an array of emitters (Figure 1). The flow rate delivered to each emitter is thus reduced, allowing the well-documented benefits of nanoelectrospray 1 for both sensitivity and quantitation to be realized for higher flow rate separations. To complement the increased ionization efficiency afforded by multi-ESI, tandem electrodynamic ion funnels have also been developed at PNNL, and shown to greatly improve ion transmission efficiency in the ion source interface.2, 3 These technologies have been integrated into a triple quadrupole mass spectrometer for multiple reaction monitoring (MRM) of probable biomarker candidates in blood plasma and show promise for the identification of new species even at low level concentrations.

59 BASIC BIOLOGICAL SCIENCES↗

Laser-optical investigation of the effect of diamond nanoparticles on the structure and functional properties of proteins

Adsorption of such blood plasma proteins as albumin and g-globulin on diamond nanoparticles of size around 5 nm and around 100 nm is observed and studied using laser-optical methods. The adsorption of blood plasma proteins at physiological pH 7.4 is found weaker than that of enzyme protein lysozyme. The observed variations in the Fourier Transform Infrared (FTIR) spectra of proteins may be due to structural transformations of the adsorbed protein. Using the lysozyme as a test protein we show that the protein adsorption leading to observable changes in the FTIR spectrum (the band of Amide I) also induces a significant decrease in the protein functional activity. It is also found that the influence of {approx}5-nm diamond nanoparticles on the protein structure and functions is more significant than that of {approx}100-nm nanodiamonds. (application of lasers and laser-optical methods in life sciences)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing the sensitivity of selected reaction monitoring-based targeted quantitative proteomics

Selected reaction monitoring (SRM)—also known as multiple reaction monitoring (MRM)—has emerged as a promising high-throughput targeted protein quantification technology for candidate biomarker verification and systems biology applications. A major bottleneck for current SRM technology, however, is insufficient sensitivity for e.g., detecting low-abundance biomarkers likely present at the pg/mL to low ng/mL range in human blood plasma or serum, or extremely low-abundance signaling proteins in the cells or tissues. Herein we review recent advances in methods and technologies, including front-end immunoaffinity depletion, fractionation, selective enrichment of target proteins/peptides or their posttranslational modifications (PTMs), as well as advances in MS instrumentation, which have significantly enhanced the overall sensitivity of SRM assays and enabled the detection of low-abundance proteins at low to sub- ng/mL level in human blood plasma or serum. General perspectives on the potential of achieving sufficient sensitivity for detection of pg/mL level proteins in plasma are also discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Identification of Disulfide Bonds in Protein Proteolytic Degradation Products Using de Novo-Protein Unique Sequence Tags Approach

Disulfide bonds are a form of posttranslational modification that often determines protein structure(s) and function(s). In this work, we report a mass spectrometry method for identification of disulfides in degradation products of proteins, and specifically endogenous peptides in the human blood plasma peptidome. LC-Fourier transform tandem mass spectrometry (FT MS/MS) was used for acquiring mass spectra that were de novo sequenced and then searched against the IPI human protein database. Through the use of unique sequence tags (UStags) we unambiguously correlated the spectra to specific database proteins. Examination of the UStags’ prefix and/or suffix sequences that contain cysteine(s) in conjunction with sequences of the UStags-specified database proteins is shown to enable the unambigious determination of disulfide bonds. Using this method, we identified the intermolecular and intramolecular disulfides in human blood plasma peptidome peptides that have molecular weights of up to ~10 kDa.

59 BASIC BIOLOGICAL SCIENCES↗

Zika viral dynamics and shedding in rhesus and cynomolgus macaques

Infection with Zika virus has been associated with serious neurological complications and fetal abnormalities. However, the dynamics of viral infection, replication and shedding are poorly understood. Here we show that both rhesus and cynomolgus macaques are highly susceptible to infection by lineages of Zika virus that are closely related to, or are currently circulating in, the Americas. After subcutaneous viral inoculation, viral RNA was detected in blood plasma as early as 1 d after infection. Viral RNA was also detected in saliva, urine, cerebrospinal fluid (CSF) and semen, but transiently in vaginal secretions. Although viral RNA during primary infection was cleared from blood plasma and urine within 10 d, viral RNA was detectable in saliva and seminal fluids until the end of the study, 3 weeks after the resolution of viremia in the blood. The control of primary Zika virus infection in the blood was correlated with rapid innate and adaptive immune responses. We also identified Zika RNA in tissues, including the brain and male and female reproductive tissues, during early and late stages of infection. Re-infection of six animals 45 d after primary infection with a heterologous strain resulted in complete protection, which suggests that primary Zika virus infection elicits protective immunity. Finally, early invasion of Zika virus into the nervous system of healthy animals and the extent and duration of shedding in saliva and semen underscore possible concern for additional neurologic complications and nonarthropod-mediated transmission in humans.

59 BASIC BIOLOGICAL SCIENCES↗

Peripheral blood hematology, plasma biochemistry, and the optimization of an in vitro immune-based assay in the brown watersnake ( Nerodia taxispilota )

Reptiles represent a phylogenetic lineage that provides a unique link between ectothermic anamniotes and endothermic amniotes. Compared to mammalian and avian species, our understanding of the reptilian immune system is greatly lacking. This gap in knowledge is largely due to an absence of established immune-based assays or specific reagents for these species. In the present study, brown watersnakes (Nerodia taxispilota) were live-captured in the wild, sexed, weighed, measured, bled via the caudal vein and released. At 24 hr post-collection, peripheral blood leukocytes were enriched and evaluated with an established mammalian in-vitro lymphocyte proliferation assay. Snake peripheral blood leukocyte enrichment yielded > 90% lymphocytes with viabilities averaging 81.5%. Baseline physiologic data for N. taxispilota, including hematology and total solids, leukocyte differentials, cell recovery and plasma biochemistry, were also collected. Cells cultured with Concanavalin A exhibited significantly increased proliferation at both 72 and 96 hr. Furthermore, these preliminary results show that enriched peripheral blood from wild-caught N. taxispilota provides a sufficient yield of leukocytes that can be cultured and functionally evaluated using a standard mammalian in-vitro immune-based assay.

59 BASIC BIOLOGICAL SCIENCES↗

Simulated Night- Shift Schedule Disrupts the Plasma Lipidome and Reveals Early Markers of Cardiovascular Disease Risk

Introduction: The circadian system coordinates daily rhythms in lipid metabolism, storage and utilization. Disruptions of internal circadian rhythms due to altered sleep/wake schedules, such as in night-shift work, have been implicated in increased risk of cardiovascular disease and metabolic disorders. To determine the impact of a night-shift schedule on the human blood plasma lipidome, an in-laboratory simulated shift work study was conducted. Methods: Fourteen healthy young adults were assigned to 3 days of either a simulated day or night-shift schedule, followed by a 24-h constant routine protocol with fixed environmental conditions, hourly isocaloric snacks, and constant wakefulness to investigate endogenous circadian rhythms. Blood plasma samples collected at 3-h intervals were subjected to untargeted lipidomics analysis. Results: More than 400 lipids were identified and quantified across 21 subclasses. Focusing on lipids with low between-subject variation per shift condition, alterations in the circulating plasma lipidome revealed generally increased mean triglyceride levels and decreased mean phospholipid levels after night-shift relative to day-shift. The circadian rhythms of triglycerides containing odd chain fatty acids peaked earlier during constant routine after night-shift. Regardless of shift condition, triglycerides tended to either peak or be depleted at 16:30 h, with chain-specific differences associated with the direction of change. Discussion: The simulated night-shift schedule was associated with altered temporal patterns in the lipidome. This may be premorbid to the elevated cardiovascular risk that has been found epidemiologically in night-shift workers.

59 BASIC BIOLOGICAL SCIENCES↗