Search NASASearch

SEARCH · Search NASA

Results for “Battery degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

564 records · Page 2

Mechanical Properties of Carbon Fiber Reinforced Composites Exposed to Cryogenic Conditions and Space Radiation via Simulation and Testing

As NASA missions extend beyond low Earth orbit, increasing reliance is placed on carbon fiber reinforced polymer (CFRP) composites for spacecraft structures where mass efficiency, durability, and long-term reliability are critical. In service, these materials are subjected to a combination of ultraviolet radiation, vacuum, ionizing radiation, atomic oxygen, and extreme thermal excursions under sustained mechanical loading. Flight systems such as the Boeing Starliner and SpaceX Dragon employ external composite structures that will experience these environments for extended durations. Although prior spaceflight and ground studies have reported limited changes in bulk mechanical properties, the synergistic effects of these environments on composite microstructure, particularly at the fiber matrix interphase, remain insufficiently characterized and represent a potential qualification and reliability risk. This study investigates the effects of short-term cryogenic exposure on a radiation shielding carbon epoxy composite, SC2020, as a ground-based analog for space relevant thermal extremes. The SC2020 material system has previously flown on the International Space Station under the Materials International Space Station Experiment (MISSE) program. Composite specimens were exposed to liquid nitrogen for 6 and 24 hours and evaluated using a multiscale characterization framework that combined ASTM D3039 tensile testing, Atomic Force Microscopy (AFM) based interphase analysis, and helium gas permeability measurements. Tensile testing showed no statistically significant or permanent degradation in global strength or modulus following cryogenic exposure. In contrast, AFM measurements revealed reductions in interphase modulus, weakened adhesion, and increased nanoscale heterogeneity, indicating localized degradation mechanisms not captured by conventional bulk testing. Gas permeability measurements showed a progressive increase in helium diffusion with exposure duration, consistent with micro-void formation or partial interfacial debonding. The results indicate that cryogenic exposure initiates degradation at the fiber matrix interphase while leaving global mechanical properties largely unchanged over short durations. These findings underscore the importance of multiscale diagnostics for identifying early-stage damage mechanisms that may influence long term performance and qualification margins for spaceflight composite structures. The data presented establish a cryogenic baseline for comparison with forthcoming MISSE flight exposure results and support ongoing NASA Established Program to Stimulate Competitive Research (EPSCoR) efforts aimed at improving composite qualification methodologies, risk assessment, and reliability prediction for space environments.

composite reliability

Enabling Mission Flexibility to Battery Driven Deep Space Endeavors With Generalized Battery-Health-Monitoring Using Physics-Based and Data-Driven Reduced-Order Models

The needs and requirements for an electrochemical energy storage for deep space exploration is well explored. It is often understood that different mission sites and environmental conditions require different battery chemistries or technologies. Additionally, various engineering solutions are deployed to overcome specific chemical challenges. One often overlooked need is the “health” monitoring of an electrochemical storage system. The term generalized health monitoring, as envisioned in this work, refers to the monitoring of various aspects such as electrode health, electrolyte health, reaction pathway health, cooling system health, sensor health, and BMS health [1]. Generalized health monitoring allows mission leads, engineers, and scientists to incorporate flexibility in mission designs, make on-the-fly mission changes, and extend the duration of science missions. Moreover, it enables automation and data-driven decision-making without compromising safety and performance. Recently, our group developed a hierarchy of thermal reduced-order models (TROM) by combining a physics-based modeling approach and data-driven model reduction techniques applied to flight data [2]. The resulting TROMs were found to be not only accurate but also identifiable from the flight data. Consequently, the coefficient of variance of the model parameters is small over the course of hundreds of flights, allowing for monitoring the parameter evolution trajectories as the battery ages and degrades. These parameters constitute the metrics of the generalized health of a battery. Monitoring their evolution allows such models to be used for anomaly detection and prognostics, improving early detection of abnormal behavior and thus enabling timely maintenance, longer battery life, and enhanced battery safety. For this presentation, the practicality of the thermal model will be validated on a pack of 14cells under various topology configurations such as 1S14P, 2P7S, 7S2P, and 1P14S. It is well known that manufacturing and non-uniform aging lead to variability in the performance of a cell, which is exacerbated by cell balancing during active load. Additionally, in extreme scenarios, the paramount objective is to complete the mission, regardless of the stresses on the battery. Topology-induced balancing issues further stress the battery. The goal of this study is to determine if the noise (identifiability) in the reduced-order thermal model parameters is sensitive to topology, cell spacing, cooling strategy, and manufacturing or age variability. The variability in cells is considered by assuming a multimodal distribution for microscopic parameters of a cell (such as porosity, tortuosity, reaction kinetics, volumetric thermal conductivity, and volumetric heat capacity). The compounded effect of manufacturing variability, topological selection, cooling strategies, and cell balancing ages each cell in a battery differently. The study aims to clarify whether the challenge in extracting maximum information depends on the minimum number of sensors or models used for data extraction.

Automation

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez

Solar Array Automation Limitations

Significant progress in the automation of the spacecraft electrical power systems has been made within the past few years. This is especially important with the development of the space station and the increasing demand on the electrical power systems for future satellites. The key element of the spacecraft power system, the solar arrays which supply the power, will have to grow to supply many tens of kilowatts of power within the next twenty years. This growth will be accompanied by the problems associated with large distributed power systems. The growth of the arrays, the on-array management problems and potential solutions to array degradation or failure are discussed. Multilowatt arrays for unmanned spacecraft with comments on the implications of array degradation for manned spacecraft are discussed.

Terry M Trumble

Application of Energy-efficient Electromagnetic Melt-Processing for the Upcycling of Recycled Polyphenylene Sulfide into Multifunctional Segregated Nanocomposites

Polyphenylene sulfide (PPS) is widely used in structural and functional composites because of its thermal stability, chemical resistance, and mechanical strength. As circular manufacturing becomes increasingly important, extending the service life of recycled PPS (rPPS) is essential. However, conventional high-temperature reprocessing accelerates thermo-oxidative degradation, reducing recycled composite performance. This study proposes a rapid and potentially energy-saving upcycling strategy for rPPS using electromagnetic (EM) melt-processing to form segregated carbon nanotube (CNT) networks and produce EM-responsive nanocomposites. The aim was to determine whether CNT-assisted EM heating could reduce polymer degradation while improving multifunctional properties at ultralow filler loadings. rPPS micropellets were coated with CNTs by ball milling to create conductive shells, then compacted into green bodies (GBs) and selectively melted by rapid EM irradiation. Structural, electrical, mechanical, rheological, and electromagnetic interference (EMI) shielding properties were evaluated. Electrical percolation occurred at an ultralow CNT loading of 0.08 wt%, with conductivity reaching (1.24 ± 0.74) × 10 -5 S⋅m -1 at 0.1 wt%. At this concentration, tensile strength and modulus increased by 72% and 99%, respectively. At ~ 0.7 mm thickness, X-band EMI shielding effectiveness reached 6 dB for GBs and 3 dB after EM processing. This shows that EM melt-processing upcycles rPPS into high-performance multifunctional nanocomposites with minimum thermal degradation.

recycled

Investigation of Bipropellant Plume-Induced Contamination Effects on Coverglass Materials

Contamination and degradation of external spacecraft materials by unburned and partially combusted species from bipropellant thruster plumes has long been observed as a key component of the induced space environment. Space shuttle flight experiments and returned flight hardware from the International Space Station (ISS) have both experienced microscopic impact features induced by high-velocity thruster plume droplets. Analytical results have shown that droplet impingement angle relative to a receiving surface plays a key role in the surface damage. Although impacts with normal impingement angles contribute more severely to surface degradation than highly oblique angles, surface effects at higher impingement angles should not be dismissed. Thruster plume-induced materials degradation is a complex phenomenon that depends on a variety of parameters, including but not limited to material type, system temperature and pressure, plume composition, and thruster firing specifications such as number of pulses, pulse duration, and sample distance from the thruster. For space applications, attaining the vacuum pressure and temperature conditions necessary for flight-like plume expansion and exposure conditions is not a trivial task. The German Aerospace Center (Deutsches Zentrum für Luft- und Raumfahrt, DLR) is a facility uniquely capable of simulating such conditions. Test coupons were exposed to bipropellant thruster firings under high vacuum at the DLR facility. Percent area coverage (PAC) and droplet size distributions were evaluated for the uncoated and coated solar array coverglass materials over a range of impingement angles (0̊ to 75̊). A post-test imaging workflow was developed that aimed to quantify changes in sample surface morphology obtained from scanning electron microscopy (SEM) images using the Image Processing and Analysis in Java (ImageJ) tool; an opensource image processing software. The goal was to create a framework through which to evaluate the effect of bipropellant-induced PAC and droplet size distribution on solar array coverglass optical transmission losses. Understanding this relationship is important because optical transmission losses are known to lead to current reduction in solar power generation systems. In addition to the development of surface characterization workflows, valuable lessons learned as they pertain to future investigations and experiments will be discussed. The authors hope that sharing these lessons will facilitate more utilization of DLR’s unique capabilities as well as open the conversation for how best to address experimental characterization of flight-like plume expansion and its impacts on materials surface degradation effects.

Gateway

Bosch Carbon Catalyst Regeneration in Water II: Analysis of Bosch Catalyst Beads Throughout the Initial Regeneration Process

Catalyst integrity is an important factor in reactor longevity since it changes the effectiveness of a reaction. A Carbon Formation Reactor (CFR), used within Series Bosch (S-Bosch), utilizes an iron alloy catalyst to convert carbon monoxide and hydrogen into water and solid carbon. The catalyst promotes the formation of carbon to such an extent that pressure-causing clogs form within the reactor and reaction sites on the catalyst become limited. To remove carbon from both the reactor and the surface of the iron alloy catalyst, a technique was developed that utilizes water, an In-Situ Resource Utilization (ISRU) Resource, and agitation to regenerate the reactor. To ascertain catalyst integrity throughout this regenerative process, sample catalyst beads were taken before and after the carbon formation reaction, and then after the regeneration process. Additionally, wastewater from the regeneration process was sampled. The sampled beads and wastewater were observed under a Scanning Electron Microscopy (SEM) microscope and the beads were chemically etched to determine if the catalyst had degraded at any point during this process, and if catalyst was lost. Minimal catalyst degradation was observed after carbon formation in the CFR.

regeneration

Bosch Carbon Catalyst Regeneration in Water II: Analysis of Bosch Catalyst Beads Throughout the Initial Regeneration Process

Catalyst integrity is an important factor in reactor longevity since it changes the effectiveness of a reaction. A Carbon Formation Reactor (CFR), used within Series Bosch (S-Bosch), utilizes an iron alloy catalyst to convert carbon monoxide and hydrogen into water and solid carbon. The catalyst promotes the formation of carbon to such an extent that pressure-causing clogs form within the reactor and reaction sites on the catalyst become limited. To remove carbon from both the reactor and the surface of the iron alloy catalyst, a technique was developed that utilizes water, an In-Situ Resource Utilization (ISRU) Resource, and agitation to regenerate the reactor. To ascertain catalyst integrity throughout this regenerative process, sample catalyst beads were taken before and after the carbon formation reaction, and then after the regeneration process. Additionally, wastewater from the regeneration process was sampled. The sampled beads and wastewater were observed under a Scanning Electron Microscopy (SEM) microscope and the beads were chemically etched to determine if the catalyst had degraded at any point during this process, and if catalyst was lost. Minimal catalyst degradation was observed after carbon formation in the CFR.

Series Bosch

Erosion Results of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4)

Polymers and other oxidizable materials on the exterior of spacecraft in the low Earth orbit (LEO) space environment can be eroded from reaction with atomic oxygen (AO). Therefore, in order to design durable spacecraft it is important to know the extent of erosion that will occur during a mission. This can be determined by knowing the LEO AO erosion yield, E y (volume loss per incident oxygen atom), of materials susceptible to AO reaction. In addition, recent flight experiments have shown that the AO E y can vary with the AO fluence and/or solar exposure. Therefore, obtaining AO E y data for materials flown on various spaceflight missions is important. NASA Glenn Research Center has flown numerous experiments as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS) to characterize the LEO E y of polymers, composites, protective coatings, and other spacecraft materials. Recently, four Glenn experiments with 365 flight (F) samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Although each experiment had numerous sample objectives, the primary objective was to determine the LEO AO E y of various spacecraft materials as a function of solar irradiation and AO fluence. This paper provides a summary of the erosion data for the PCE 1-4 AO E y samples. The AO E y for 150 samples flown in either the LEO ram, wake, zenith or nadir directions are provided. The AO ram fluence varied from 2.97×10 20 atoms/cm 2 after 0.89 years of direct space exposure (with relatively high levels of Si contamination) on MISSE 12 to 3.93×10 20 atoms/cm 2 after 1.17 years of direct space exposure on MISSE-10. The ram AO E y values for uncoated polymers range from 3.81×10 –25 cm 3 /atom for polytetrafluoroethylene (M9R-C20 F) exposed to an AO fluence of 3.44×10 20 atoms/cm 2 on MISSE-9 to 4.43×10 –23 cm 3 /atom for AO etched low density polyimide aerogel (M12R-C21 F) exposed to an AO fluence of 2.97×10 21 atoms/cm 2 on MISSE-12. Because of the low AO fluence and relatively high Si contamination, a number of PCE-3 wake samples experienced mass gain. Thus, AO E y values are not provided for these samples. Although there are calculated AO E y values for the zenith, wake and nadir samples, the ram AO E y for a particular material is a more reliable value in terms of AO exposure because the zenith, wake and nadir directions were exposed to either no or very little AO fluence and thus other space environmental factors (i.e. vacuum, thermal extremes and thermal cycling, and/or various types of radiation) are responsible for the mass loss.

Erosion yield

Predicting Team Functioning in Long Term Space Missions Using Acoustic and Linguistic Measures

Maintaining optimal team functioning is critical for long-duration space exploration missions, yet traditional monitoring methods, such as self-reports and wearable sensors, often impose operational burdens or suffer from bias. This paper investigates a non-intrusive speech-based artificial intelligence (AI) framework to predict degradations in team functioning using data from the Human Exploration Research Analog (HERA) of the U.S. National Aeronautics and Space Administration (NASA). Using acoustic features, linguistic descriptors, and semantic embeddings, we evaluate static non-linear and temporal machine learning models to predict both objective (task accuracy) and subjective (self-reported efficacy and cohesion) team functioning outcomes. Results indicate that temporal models outperform static approaches, with prediction of objective task accuracy in Team Interaction Battery (TIB) improving from near chance to 71%. Self-reported outcomes, including team efficacy and cohesion, are predicted more reliably than task performance, achieving balanced accuracies of up to 85.56% and 78.12%, respectively, and are found to be most strongly associated with acoustic features. In a second interdependent task, the MMSEV–EVA, accuracies of up to 78% are achieved using temporal models with acoustic features. Furthermore, incorporating just 1–2 days of team-specific historical data systematically improved performance, and acoustic markers from informal pre-task interactions provided modest predictive gains. Finally, while automated preprocessing yielded viable accuracy, humancorrected data provided moderate performance gains, though transcription error rates did not significantly correlate with model performance. These findings highlight the potential of speech as a passive, high-fidelity monitoring tool for autonomous habitats.

Temporal modeling

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

iodine

Improved multilayer insulation applications

Multilayer insulation blankets used for the attenuation of radiant heat transfer in spacecraft are addressed. Typically, blanket effectiveness is degraded by heat leaks in the joints between adjacent blankets and by heat leaks caused by the blanket fastener system. An approach to blanket design based upon modular sub-blankets with distributed seams and upon an associated fastener system that practically eliminates the through-the-blanket conductive path is described. Test results are discussed providing confirmation of the approach. The specific case of the thermal control system for the optical assembly of the Space Telescope is examined.

George Mikk

Solar Absorptance and Thermal Emittance of Some Common Spacecraft Thermal-Control Coatings

Solar absorptance and thermal emittance of spacecraft materials are critical parameters in determining spacecraft temperature control. Because thickness, surface preparation, coatings formulation, manufacturing techniques, etc. affect these parameters, it is usually necessary to measure the absorptance and emittance of materials before they are used. Absorptance and emittance data for many common types of thermal control coatings, are together with some sample spectral data curves of absorptance. In some cases for which ultraviolet and particle radiation data are available, the degraded absorptance and emittance values are also listed.

John H Henninger

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

RTV

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

silicone intumescence

Organic Inventory - Planetary Protection on the Moon

All spacecraft generate and carry contaminants, i.e., unwanted and potentially harmful material. When a spacecraft lands and operates in vacuum, as onto Earth’s Moon, it introduces contaminants into its environment that may compromise mission science objectives and engineering performance. Contamination may degrade sites of unique value to planetary science or in situ resource utilization. This presentation will identify and compare source terms and transport vectors for contaminants – in particular, organic material – generated by landed spacecraft. An integrated modeling framework for the organic contamination footprint of spacecraft missions will be described and presented.

Planetary Protection