Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beamline IDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

12-ID SMI Beamline Radiation Shielding Analysis

The NSLS-II Beamline Radiation Shielding Policy has been stated as follows in reference 1: Radiation exposure to staff and users resulting from National Synchrotron Light Source II (NSLS-II) operations must comply with Brookhaven National Laboratory (BNL) and Department of Energy (DOE) radiation requirements and must be maintained as low as reasonably achievable (ALARA). Per the Photon Sciences Shielding Policy (PS-C-ASD-POL-005), in continuously occupied areas during normal operation the dose rate is ALARA, and shall be < 0.5 mrem/h (based on occupancy of 2000 hours/year) or less than 1 rem in a year.

36 MATERIALS SCIENCE↗

19-ID NYX Beamline Radiation Shielding Analysis

The NSLS-II Beamline Radiation Shielding Policy has been stated as follows in Reference 1: Radiation exposure to staff and users resulting from National Synchrotron Light Source II (NSLS-II) operations must comply with Brookhaven National Laboratory (BNL) and Department of Energy (DOE) radiation requirements and must be maintained as low as reasonably achievable (ALARA).

36 MATERIALS SCIENCE↗

19-ID NYX Beamline Radiation Shielding Analysis - Updated

The NSLS-II Beamline Radiation Shielding Policy has been stated as follows in Reference 1: Radiation exposure to staff and users resulting from National Synchrotron Light Source II (NSLS-II) operations must comply with Brookhaven National Laboratory (BNL) and Department of Energy (DOE) radiation requirements and must be maintained as low as reasonably achievable (ALARA). In accordance with the Photon Science Shielding Policy (PS-C-ASD-POL-005), in continuously occupied areas during normal operation the dose rate is ALARA, and shall be < 0.5 mrem/h (based on occupancy of 2000 hours/year) or less than 1 rem in a year.

36 MATERIALS SCIENCE↗

02-ID SIX Beamline Radiation Shielding Analysis

The NSLS-II Beamline Radiation Shielding Policy has been stated as follows in reference 1: Radiation exposure to staff and users resulting from National Synchrotron Light Source II (NSLS-II) operations must comply with Brookhaven National Laboratory (BNL) and Department of Energy (DOE) radiation requirements and must be maintained as low as reasonably achievable (ALARA). Per the Shielding Policy (PS-C-ASD-POL-005), in continuously occupied areas during normal operation the dose rate is ALARA, and shall be < 0.5 mrem/h (based on occupancy of 2000 hours/year) or less than 1 rem in a year.

36 MATERIALS SCIENCE↗

16-ID LIX Beamline Radiation Shielding Analysis

The NSLS-II BEAMLINE RADIATION SHIELDING POLICY has been stated as follows in reference 1: Radiation exposure to staff and users resulting from National Synchrotron Light Source II (NSLS-II) operations must comply with Brookhaven National Laboratory (BNL) and Department of Energy (DOE) radiation requirements and must be maintained as low as reasonably achievable (ALARA). Per the Photon Science Shielding Policy (PS-C-ASD-POL-005), in continuously occupied areas during normal operation the dose rate is ALARA, and shall be < 0.5 mrem/h (based on occupancy of 2000 hours/year) or less than 1 rem in a year.

36 MATERIALS SCIENCE↗

8-ID ISS Beamline Radiation Shielding Analysis

The NSLS-II BEAMLINE RADIATION SHIELDING POLICY has been stated as follows in reference 1: Radiation exposure to staff and users resulting from National Synchrotron Light Source II (NSLS-II) operations must comply with Brookhaven National Laboratory (BNL) and Department of Energy (DOE) radiation requirements and must be maintained as low as reasonably achievable (ALARA).

36 MATERIALS SCIENCE↗

21-ID SIX Beamline Radiation Shielding Analysis

The radiation shielding analysis of Soft Inelastic X-ray Scattering(SIX, 2ID) at 500 mA is documented in this technical note, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

21-ID ESM Beamline Radiation Shielding Analysis

The radiation shielding analysis of Electron Spectro-Microscopy (ESM, 21ID) at 500 mA is documented in this technical note, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR). Figure 1 shows the layout of ESM beam line, which uses 2 undulators (EPU105 or EPU57).

36 MATERIALS SCIENCE↗

04-ID ISR Beamline Radiation Shielding Analysis

The NSLS-II Beamline Radiation Shielding Policy has been stated as follows in reference 1: Radiation exposure to staff and users resulting from National Synchrotron Light Source II NSLS-II) operations must comply with Brookhaven National Laboratory (BNL) and Department of Energy (DOE) radiation requirements and must be maintained as low as reasonably achievable (ALARA). Per the Photon Science Shielding Policy (PS-C-ASD-POL-005), in continuously occupied areas during normal operation the dose rate is ALARA, and shall be < 0.5 mrem/h (based on occupancy of 2000 hours/year) or less than 1 rem in a year.

36 MATERIALS SCIENCE↗

21-ID ESM Beamline Radiation Shielding Analysis

Beamlines are required to shield against two primary sources of radiation, the primary gas bremsstrahlung (GB) and the synchrotron beam, as well as the secondary radiation resulting from the scattering of these two primary beams by the beamline components and/or air.

36 MATERIALS SCIENCE↗

Minimizing Experimental Setup Time and Effort at APS beamline 1-ID through Instrumentation Design

Sector 1-ID at the APS accommodates a number of dif-ferent experimental techniques in the same spatial enve-lope of the E-hutch end station. These include high-energy small and wide angle X-ray scattering (SAXS and WAXS), high-energy diffraction microscopy (HEDM, both near and far field modes) and high-energy X-ray tomography. These techniques are frequently combined to allow the users to obtain multimodal data, often attaining 1 μm spatial resolution and <0.05º angular resolution. Furthermore, these techniques are utilized while the sam-ple is thermo-mechanically loaded to mimic real operat-ing conditions. The instrumentation required for each of these techniques and environments has been designed and configured in a modular way with a focus on stability and repeatability between changeovers. This approach allows the end station to be more versatile, capable of collecting multi-modal data in-situ while reducing time and effort typically required for set up and alignment, resulting in more efficient beam time use. Key instrumentation de-sign features and layout of the end station are presented.

Benda, Erika↗

Focusing with saw-tooth refractive lenses at a high-energy X-ray beamline

The Advanced Photon Source 1-ID beamline, operating in the 40–140 keV X-ray energy range, has successfully employed continuously tunable saw-tooth refractive lenses to routinely deliver beams focused in both one and two dimensions to experiments for over 15 years. The practical experience of implementing such lenses, made of silicon and aluminium, is presented, including their properties, control, alignment, and diagnostic methods, achieving ∼1 µm focusing (vertically). Ongoing development and prospects towards submicrometre focusing at these high energies are also mentioned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beamline CSX (23-ID, EPU 49): 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline CSX (23-ID-1) was conducted on March 27, 2015 in accordance with the Beamline CSX (23-ID, EPU 49) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the 23-ID beamline First Optics Enclosure (FOE) and downstream beam pipe. At the time of this comprehensive survey, 23-ID-2 beamline was still undergoing technical commissioning and therefore Section II “23 ID-2 FOE, exclusion zone and downstream pipe” could not be completed. During the surveys the stored beam current varied between 21.43 mA and 23.51 mA, the 23-ID straight section vacuum was around 0.44 ntorr, and front-end slits were open near their hard stop limits.

36 MATERIALS SCIENCE↗

Beamline SRX (05-ID, IVU 21): 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline SRX (05-ID, In-Vacuum Undulator) was conducted on March 20, 2015 in accordance with the Beamline SRX (05-ID) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the 3, 05-ID beamline enclosures (05-ID-A, 05-ID-B and 05-ID-D) and the transport pipe in between 05-ID-A, 05-ID-B and 05-ID-D. Enclosure 05-ID-C currently has only a transport pipe connecting 05-ID-B and 05-ID-D, but will serve as the experimental end station as future branch line for the second IVU. During the surveys the stored beam current varied between 21.04 and 24.87 mA, the 05ID straight section vacuum was around 0.43 ntorr, andfront-end slits opened near their hard stop limits.

36 MATERIALS SCIENCE↗

Beamline IXS (10-ID, IVU 22) 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline IXS (10-ID, In-Vacuum Undulator) was conducted on March 2 and 4, 2015 in accordance with the Beamline IXS (10-ID) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the four 10-ID beamline enclosures (10-ID-A, 10-ID-B, 10-ID-C and 10-ID-D) and transport pipe between 10-ID-B and 10-ID-C. During the surveys the stored beam current varied between 24.83 and 21.77 mA, the ID-10 straight section vacuum was around 0.58 ntorr, and front-end slits open near their hard stop limits.

36 MATERIALS SCIENCE↗

Beamline HXN (03-ID, IVU 20): 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline HXN (03-ID, In-Vacuum Undulator) was conducted on February 27 and March 9, 2015 in accordance with the Beamline HXN (03-ID) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the three, 03-ID beamline enclosures (03-ID-A, 03-ID-B, and 03-ID-C) and transport pipes between 03-ID-A and 03-ID-B, and between 03-ID-B and 03-ID-C. During the surveys the stored beam current varied between 20.75 and 23.15 mA,the ID-03 straight section vacuum was approximately 0.76 ntorr, and front-end slits were open near their hard stop limits.

36 MATERIALS SCIENCE↗

Beamline XPD (28-ID, DW 100) 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline XPD (28-ID, Damping Wiggler) was conducted on March 16, March 30 and April 09, 2015 in accordance with the Beamline XPD (28-ID) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the two 28-ID beamline enclosures in use (28-ID-A, 28-ID-C) and the transport pipe in between 28-ID-A and 28-ID-C. Enclosure 28-ID-B currently has only a transport pipe connecting 28-ID-A and 28-ID-C, and is expected to be used as the experimental end station for future branch line.

36 MATERIALS SCIENCE↗

Beamline CHX (11-ID, IVU 20): 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline CHX (11-ID, In-Vacuum Undulator) was conducted on March 12 and 13, 2015 in accordance with the Beamline CHX (11-ID) Radiation Survey Plan [1]. Some initial setup of the beamline and front end slits was needed and completed on March 09, 2015. The purpose of the survey was to verify the shielding integrity of the two 11-ID beamline enclosures (11-ID-A and 11-ID-B) and transport pipe between 11-ID-A and 11-ID-B.

36 MATERIALS SCIENCE↗