Characterization Results for the April 2022 Tank Farm 2H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents characterization results for the April 2022 2H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Forensic Examinations in Support of Breach Sealed Source Event at Harborview Medical Facility on 2 May 2019

On May 2, 2019, International Isotopes, Inc. (INIS), a subcontractor to Triad National Security, LLC (contractor for Los Alamos National Laboratory) breached a sealed radioactive source containing ~2800 Ci of the radioactive isotope cesium-137 ( 137 Cs) at the University of Washington Harborview Research and Training (HRT) Building in downtown Seattle while attempting to recover the source for the National Nuclear Security Administration’s (NNSA’s) Off-site Source Recovery Program (OSRP). The breach of the source resulted in the contamination of 13 personnel, all 7 floors of the building, and a release of material to the environment. A summary of root and contributing causes of the event was investigated and published by a joint investigation team (JIT) co-led by NNSA and Triad National Security, LLC. That investigation was supported by forensics examinations provided by Pacific Northwest National Laboratory. This report summarizes the results of those forensic examinations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cesium Removal from 5.5 and 7.0 M Na AP-105 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational by Washington River Protection Solutions LLC (WRPS), prepares initial low-activity Hanford waste tank supernate feeds for the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is < 3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), has been selected as the ion exchange media for TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, testing to date on actual tank waste samples has been limited to Na concentrations between 5 and 6 M Na (Fiskum et al. 2019a, 2021b and Westesen et al. 2021a, 2021b, 2022) while actual tank conditions can reach upwards of 9 M Na. Testing with feed from Hanford tank AP-105 incorporated testing at both 5.5 and 7 M Na in order to evaluate the impact of Na concentration on volume of waste processed before reaching the WAC. A 6-L volume of 5.5 M Na AP-105 and an 8-volume of 7 M Na AP-105 was processed through the Radioactive Waste Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 6- to 9-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.9 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. Table S.1 and Figure S.1 summarize the measured AP-105 Cs load performance for each feed condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results for the March 2023 Tank Farm 2H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents characterization results for the March 2023 2H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from AP-106 Tank Waste Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operated by Washington River Protection Solutions, LLC, prepares Hanford waste tank supernate feeds for the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant (WTP). In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange (IX), allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is <3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST), manufactured by Honeywell UOP, LLC (product IONSIV R9140-B), was selected as the ion exchange media for TSCR.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining Cs-137 Background body burdens for Wild Pigs At Savannah River Site

Savannah River Site (SRS) is a unique U.S. Department of Energy facility in that most of the 310-square miles of land has not be industrialized since operations began in 1953. This has allowed abundant, undisturbed vegetation structure to exists as well as an increase in herd sizes among wildlife populations onsite. Cs-137 is widespread across SRS due to the production of nuclear materials, but is mostly from global atmospheric fallout from nuclear weapons testing. Due to most of SRS being undisturbed land, the concentrations of Cs-137 are higher on site than off site. The SRS began conducting annual deer harvests that were open to the public beginning in 1965. All animals harvested during these hunts are monitored for Cs-137, which is measured using a Sodium Iodide detector. There has been an effective method for calculating the background Cs-137 body burden for the deer population at the SRS, developed by Gaines and Novak using data collected during hunts and gamma overflight data to determine the areas contaminated by site activities. For animals that have a Cs-137 concentration above the established background level, a dose is assigned to the hunter. By applying the same method for wild pigs using data collected from hunts, gamma overflight, and developing a site-specific home range of wild pigs, we were able to calculate the Cs-137 background body burden concentrations of wild pigs on site. Objectives: Develop site-specific home range for wild pigs at SRS; Determine the average concentrations of Cs-137 in wild pigs from background; Use Gaines and Novak method for determining background Cs-137 body burdens wild pigs on SRS. Methods and Materials: Development of site-specific home range of wild pigs was determined to be 2.5 miles using: Four studies conducted between 1969 and 1992 for the SRS wild pig population. (Mayer and Brisbin) The background compartments were determined using: Gamma overflight data showing contaminated areas; Site-specific home range of the wild pigs. Results and Conclusion: All data were generated through the JMP software to provide a histogram and summary statistics. The estimate of an upper tolerance limit for the background contamination with 95% confidence is 1.965 pCi/g for the wild pigs. This means that for wild pigs on SRS from the background compartments are expected to have Cs-137 concentrations of less than 1.965 pCi/g. The current background for the deer is 2.59 pCi/g. For the background compartments Cs-137 concentrations from 2012-2018: Mean: 0.815 pCi/g, Maximum: 2.341 pCi/g, Minimum: -0.704 pCi/g.

07 ISOTOPE AND RADIATION SOURCES↗

Long Term Assessment of Radiocesium in Deer, Fish, Soil, and Vegetation at the Savannah River Site

Throughout the Savannah River Site's (SRS) operational history, many radionuclides have been released into the environment. However, due to fallout from weapons testing, the amount released from SRS, its persistence in the environment, and the seclusion of the Site, radiocesium (Cs-137) is one of the most critical radionuclides in the SRS environment. The Effective half-life (Te) is the time it takes for a radionuclide in the environment to decrease by 50% of its initial amount. There are three means of radionuclide removal: Physical: Radioactive decay, sedimentation, and washout; Chemical: Changes in pH, oxidation state or adsorption; Biological: Changes in the food web or translocation. Effective half-life (T{sub e}) = log{sub e}2/λ{sub e} Where λ{sub e} is estimated from the slopes of loge-transformed Cs-137 activity concentrations regressed on year. The objective of this work was to calculate the effective half-life of Cs-137 in various biota at SRS and to perform an assessment of the changes in the effective half life over time. Compared to 2013 data, there is a slight increase in the effective half-lives for fish at most sampling locations. This effective half-life increase is an indication that the rate of Cs-137 loss is starting to plateau. The effective half-life of Cs-137 in SRS fish ranges from 4-11 years. The effective half-life of Cs-137 in soil at the Creek plantation is about 15 years. The effective half-life of Cs-137 in grassy vegetation at the Creek Plantation is about 14 years. The effective half-life of deer hunted on the SRS is about 15.5 years. After termination of all reactor activity by 1980, the Cs-137 activity began to drop drastically.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Argonne SuperGel for CBRN Decontamination - 20160

The Argonne SuperGel was developed between 2003 and 2015 to fill a gap in our nation's capability to quickly decontaminate important structures following a radiological or nuclear release event. Specifically, the decontamination technology was developed to minimize damage to monuments, high valued structures, and critical infrastructure while reducing environmental and health impacts. An important criterion during its development, common reagents were employed that could be easily acquired in order to minimize the timeline for its deployment. Its current formulation uses off-the-shelf super-absorbing hydrogels common to the food and agricultural industry and common salts. Over the years, two formulations of the Argonne SuperGel have been developed to specifically target radioactive cesium contaminations and then, more generically, actinide and fission product contaminations. A biodegradable derivative of phosphoric acid is used in small amounts to promote the removal of insoluble actinide species. The original order of unit operations for the SuperGel technology was 1) applying the wash solution to promote mobility of the contaminants on the surface, 2) applying the hydrogel to absorb the wash solution and contaminants, and 3) removing the hydrogel for disposal. During the course of our studies, we tested a new formulation of the gel technology that eliminated the need for a separate step to apply the wash solution without a compromise in decontamination factors. Greater than 70% and >95% of Cs-137 were removed from concrete and tile coupons, respectively, after two decontaminations, with the best results using wash solutions of 1.0 M KCl and 1.0 M NH{sub 4}Cl formulations. We found no statistical difference between results at 30 deg. C and 40 deg. C or at 70% and 90% relative humidity. We tested the gel under strong UV irradiation to simulate extreme environments. While a tropical noontime UV flux did not adversely affect the gel system decontamination of Cs-137 from concrete or tile coupons, the noontime flux resulted in significant dehydration of the gel after two hours of constant exposure. The rehydration of the gel by the humid air (at 90% humidity and 40 deg. C) was slow and may not be sufficient to offset dehydration by the sun. Americium decontamination from concrete was 70% after optimizing the phosphoric acid derivative and carbonate salt concentration in the wash solution. Since its development, we have had the opportunity to test the SuperGel in the removal of legacy contaminations in hot cell facilities and former glovebox facilities at Argonne. This has provided a unique opportunity to evaluate the SuperGel on a range of contaminants outside the original specifications for its use. We will report on the origin of the gel formulation, some highlighted experimental data including independent testing by the US EPA which has never been reported, and its efficacy for removing legacy alpha contaminations and its potential use for removal of chemical and biological hazardous agents. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of the Corrosion Risks to a Double Shell Tank During the Selective Removal of a Cesium-rich Supernate Layer - 20227

The Direct Feed Low Activity Waste (DF-LAW) activity will provide the initial feed to the Waste Treatment and Immobilization Plant at the Hanford Tank Farm facility. Feed preparation for DF-LAW will be carried out in multiple double shell waste tanks (DST) utilizing the Tank Side Cesium Removal (TSCR) process. Tank AP-106 will be an integral part of the TSCR process and hence key to the DFLAW activity. Prior to being utilized for this purpose, the Cs-137 concentration levels in the AP-106 supernate must be reduced significantly. The AP-106 re-purposing process manages normal waste tank addition procedures such that waste acceptance criteria objectives for Cs-137 removal are achieved. As this process was being developed, several concerns regarding tank integrity during and after repurposing of Tank AP-106, and the associated tanks (i.e., AP-102, AN-101, and AP-108), were addressed. The potential corrosion degradation mechanisms identified based on process knowledge included: general and pitting corrosion, caustic stress corrosion cracking, concentration cell corrosion, and microbiologically induced corrosion (MIC). A systematic approach was undertaken to assess the risk of corrosion during the AP-106 re-purposing process. The assessment considered the initial and present condition of the tank, the service history of the tank, the environmental conditions created in each tank during each stage of the process, process timing, and corrosion testing and modeling that approximated tank conditions. Based on this information, recommendations were provided to minimize the exposure of the tank to corrosive conditions. These recommendations included time limits for each stage of the process, staging of corrosion inhibitor solutions should process delays occur, and waste sampling with potential chemistry adjustments at defined steps in the process. Additionally, recommendations for post-process supernate chemistry adjustments and tank inspections were put forth. The greatest risk for this process occurs during the manipulation of large quantities of Columbia River water (i.e., greater than 450,000 gallons) within AP-106, the associated tanks and the supporting infrastructure (i.e., transfer line piping). This risk becomes more pronounced if there is a process upset and the tank walls remain exposed to a corrosive condition longer than intended. As long as the river water is blended into the supernate in a timely fashion, and the waste is adjusted appropriately with corrosion inhibitors, corrosion may be minimized and the final condition of the supernate in AP-106 and the associated tanks is expected to be in compliance with corrosion chemistry requirements. Contingency plans will be made to minimize the impact of a process upset. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Study on Radionuclides Selection for DCGLs Development for Site Release of KRR Units 1 and 2 site in Korea - 20256

The selection of Derived Concentration Guideline Levels (DCGLs) in nuclear facilities decommissioning is important because they serve as criteria for site characterization and final status surveys. DCGLs should be derived for KAERI TRIGA Mark II and III research reactor site clearance and prior to the work, a radionuclides list for DCGLs consideration was created. Radionuclides selection for DCGLs was performed according to the procedure proposed by the US NRC based on the characterization survey related to the decommission site. By evaluating the dose contribution of each radionuclide using D and D computer code, radionuclides with a dose contribution fraction of 0.1% or more for the entire radionuclide were selected. As a result, the selected radionuclides were beta radionuclides H-3, C-14 and Sr-90 and gamma radionuclides Co-60, Cs-137, Eu-152 and Eu-154. The selected radionuclides can be presented for consultation with domestic regulatory agencies in the future and will be used as the technical base of DCGLs for the final status survey. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Characterization Strategy of a Limited Number of Radioactive Waste Effluent Tanks in View of Decommissioning a Large Number of Tanks - 20286

In order to organize the D and D of the former effluent treatment facility at the CEA Cadarache Center (France), the key data to gather through the facility characterization are the following:: volumes and masses, liquid/solid distribution and specific activity. By studying the treatment processes and the history of the facility, families of tanks have been defined and a reference tank chosen for investigation in each family. The intrusive investigations (video, residue thickness, dose rate..), the gamma spectrometry measurements carried out on site on the residue samples and radiochemical results collected in laboratories, led us to conclude that there was a relative radiological homogeneity (for specific activity and Am-241/Cs-137 ratio) within each tank. The next step consisted in extrapolating the specific activity evaluated for the reference tanks, to the other tanks of each family by using data such as geometry, dose rate or the function of the tanks within the process. Thus, a cartography of the 130 tanks of the facility is available. Finally, the conclusions drawn from the radiological homogeneity of the tanks and their affiliation to homogeneous, well-identified tank clusters lead to a simple and efficient operational approach for the D and D of the 130 tanks of the facility. Indeed, because of the residue characteristics (homogeneous activity and strong differentiation of Cs/Am ratio), a sample collected when opening the tank, and measured on site by gamma spectrometry will allow us to validate the operational design and the emptying techniques defined during the D and D study phase thanks to the characterization of a limited number of reference tanks. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TCCR Operational Summary and Optimization for Tank 9 Processing - 20314

Savannah River Remediation (SRR) manages and operates the liquid waste facilities at Savannah River Site (SRS) for the Department of Energy (DOE). Stored liquid waste is a complex mixture of insoluble solids (sludge) and soluble salts in an alkaline solution. SRR has deployed the Tank Closure Cesium Removal (TCCR) system, a tank-side ion exchange process, to remove radioactive cesium from salt waste and enable onsite disposal of the resulting decontaminated salt solution as low-level waste at the Saltstone facilities. The TCCR system consists of two prefilters, four ion exchange (IX) columns, one resin trap, and a ventilation system. The IX process uses a form of inorganic crystalline silicotitanate (CST), which has a high affinity for cesium and other alkali metals, strontium, and actinides. This process is currently deployed utilizing salt feed from Tank 10, with future plans to dissolve solid salt in Tank 9 and transfer the salt solution to Tank 10 for processing through TCCR. The feed for TCCR must be created from salt-cake in Tank 10 through a dissolution process. Once enough salt has been dissolved, a qualification process is entered. This process characterizes the feed and ensures the cesium loading on the columns will not cause boiling of waste within the columns during or after processing. Once the batch has been qualified, salt waste is fed to the TCCR system through a transfer pump in the center of the tank. The waste is filtered through a set of two shielded, dead-end prefilters that prevent solids buildup in the columns. The filtered salt solution then travels to the shielded IX columns, which can be operated individually or in series, where the cesium is sorbed on the CST media. The decontaminated salt solution (DSS) then travels through a resin trap and out of the module to Tank 11. TCCR has successfully processed approximately 795,000 L of Tank 10H radioactive salt waste over two batches to date. There has not yet been a system induced shutdown. The prefilters performed as expected with only minor degradation in recovery of differential pressure after a backflush sequence. The time between backflushes decreased as each batch reached the end of processing. The hydraulics in the IXCs mostly performed as expected at all flow rates, except for one IXC that will be further investigated during Batch 3 processing. The TCCR system has shown some opportunities for more efficient processing during the length of the demonstration so far. For future processing of material from Tank 9H through Tank 10H and the TCCR unit, TCCR 1A will implement changes to the prefilters and the IXCs. The prefilters will have an increased surface area and a new filter media in an effort to increase time between filter swaps and improve backwashing cleaning capability. The IXCs will have a reduced diameter to allow for increased heat transfer out of the column and increased loading of Cs-137. Additionally, a new form of CST with an increased kinetic performance is being investigated for use during TCCR 1A operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effects of Contaminant-Aging on Decontamination Efficacy for Rapid Remediation of Concrete Surfaces - 20412

Understanding the relationship between decontamination efficacy and contaminant aging is imperative for developing effective remediation strategies following a large-scale contamination event. Non-destructive decontamination of concrete following a contamination incident becomes more difficult with increased time between contamination and decontamination because contaminants may chemically bind to concrete and/or penetrate into the concrete subsurface. In this work, we evaluated the decontamination efficacy of two decontamination methods on concrete samples contaminated with soluble Cesium-137 (Cs-137) and silica particles with 0.5 μm and 2 μm diameters. Concrete samples were aged between 1 and 59 days, with half of the coupons receiving 1 mL of artificial rainwater about once every three days. After aging, coupons were either decontaminated or analyzed to determine contaminant penetration depths. Coupons were decontaminated with 0.1 M Potassium Chloride (KCI) solution applied either by flowing solution across the contaminated coupon face or non-destructive power washing. Contaminant depth profiles were created by removing the top surface of the coupon at least 15 times, measuring the activity in each removed layer, normalizing the total activity removed to the measured decontamination efficacy following the last layer removal, and determining the penetration thickness using the coupon dimensions, bulk density, and mass of material removed for each layer. Pressurized washing effectively removed particles, but not soluble cesium, despite the majority of Cs-137 being located within the first millimeter of the subsurface. Soluble cesium removal by flowing 0.1 M KCI solution across the contaminated surface dropped to less than 12% within the first ten days. This drop in Cs-137 removal efficacy occurred within the first five days for coupons experiencing artificial rainfall events. Flowing 0.1 M KCI solution across the contaminated face was ineffective at removing particles, likely because particles had localized in surface depressions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Qualification of Processing Batches for Tank Closure Cesium Removal Through In-Tank Batch Contact Testing - 20470

The Tank Closure Cesium Removal (TCCR) process at the Savannah River Site (SRS) is currently processing waste from Tank 10H, generating decontaminated salt solution that is sent to Tank 11H. Transfers out of Tank 11H are then disposed of on site as a grout wasteform in the SRS Saltstone Processing Facility. This is a full-scale demonstration of the use of Crystalline Silicotitanate (CST) for the decontamination of aqueous nuclear waste supernate. CST primarily removes cesium from the high sodium alkaline feed, but also adsorbs strontium, actinides, and some other trace metals. The TCCR unit is an at-tank set of four ion exchange columns, with two typically being operated in series during waste processing. Tank 10H is serving a dual function as both the salt dissolution tank as well as the feed tank for the TCCR system. Prior to operation of TCCR, Tank 10H must undergo dissolution campaigns, dissolving the salt cake to form an aqueous salt solution (supernate). After each dissolution campaign, the supernate created must be qualified prior to processing through the TCCR system. Qualification includes detailed characterization of the supernate as well as in-tank batch contact tests to determine the equilibrium loading of Cs-137 on the CST ion exchange media (IONSIV{sup TM} R9120-Ba). In support of the in-tank batch contact testing, Savannah River National Laboratory (SRNL) developed a CST sample holder, also referred to as a 'tea-bag', to hold a measured amount (∼0.1 grams) of pretreated CST between stainless steel screens. The tea-bag fits within a standard stainless steel sample vial that has been modified to allow the flow of supernate to the CST. This sample holder is then immersed in the waste tank allowing free contact between the CST beads and the surrounding liquid, at an effectively infinite liquid-to-solid phase ratio. A pair of tea-bags are deployed in the tank for a period of 10 days for each batch, after which the CST is recovered, digested, and analyzed to determine the loading of cesium isotopes on the CST. This result then supports the TCCR column thermal loading limits for processing as part of the TCCR safety basis. This paper will discuss the design and testing of the CST sample holder, as well as results from the first few batches of waste qualified and subsequently processed through the TCCR system. In addition, results from analyses of Tank 11H samples, showing decontamination of the product will be included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recovery of Cs-137 from Electric Arc Furnace Dust - 20562

The present work proposes the Cs-137 recovery from Electric Arc Furnace Dusts (EAFD) by leaching, in order to reduce the volume of radioactive waste to be managed. Leaching tests were performed on different samples of EAFD contaminated with Cs-137. Two leaching methodologies were tested: dynamic and static using as medium distilled water and in some cases NaOH. The results indicate the possibility of recovering Cs-137 from EAFD using the dynamic method; however, the recovery efficiencies of Cs-137 depend on EAFD's chemical composition. The leachates of Cs-137 were quantitatively adsorbed on exchange resins, showing its great potential to isolate or contain the Cs-137 recovery from EAFD. This study shows the feasible to apply the dynamic leaching methodology to recover Cs-137 from EAFD and the use of ion exchange resins for the isolation of removed Cs-137. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Life cycle Management of 324 Project High-Activity, Mixed/Low-Level Radioactive Waste - 20506

U.S. DOE contractor CH2M Hill Plateau Remediation Company (CHPRC) manages the 324 Building and is preparing to remotely excavate and disposition the radioactive soil beneath the building to allow further deactivation of the building. The 324 Building is a non-reactor Category 2 Nuclear Facility located in the 300 Area of the Hanford Site. Records indicate that in October 1986, approximately 516 liters of a concentrated liquid waste stream containing cesium-137 ({sup 137}Cs) and strontium-90 ({sup 90}Sr) spilled onto the floor of a hot cell, B-Cell, in the 324 Building. The spill contained an estimated 1.3 million curies (Ci) of radioactivity. A breach in the sump of B-Cell was discovered in November 2009 during characterization of the soil under the building. Exposure rates in excess of 10,000 R/hr were detected through a system of access pipes installed under the hot cell, and an estimated 1.557 E+05 Ci of {sup 137}Cs and 6.842 E+04 Ci of {sup 90}Sr are in the soil beneath B-Cell. The magnitude of the soil contamination below B-Cell represents one of the most challenging remediation activities in the DOE complex. The objective of CHPRC's 324 Project is to remotely excavate and disposition the highly contaminated soil under the hot cell so building deactivation and stabilization activities can resume. Depending on the volume and radioactivity of contaminated soil under B-Cell, the material will be dispositioned either at the Hanford Site's Environmental Restoration Disposal Facility (ERDF) or in grout monoliths that will be created in the hot cells (A, C and D) next to B-Cell during future building demolition activities. The current project scope includes installing structural supports under the walls of B-Cell and using remotely operated equipment to remove debris from the hot cell, remove debris mixed with grout on the floor, saw through and remove the cell floor and liner, and excavate contaminated soil under B-Cell to a depth of up to 3.66 meters (12 feet). Addition or removal of debris in A-Cell may be required to support B-Cell cleanout and excavation activities. The base approach is to disposition debris and soil bins in the Radiochemical Engineering Cell (REC) monoliths, and subsequently disposition the monoliths during building demolition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Testing of Alkaline Earth Metal Ion Absorption on Crystalline Silicotitanate - 20440

The Tank Closure Cesium Removal process at the Savannah River Site (SRS) has processed aqueous tank waste using the inorganic ion exchange media IONSIV{sup TM} R9120-Ba (which is also known as Crystalline Silicotitanate (CST)). Salt-cake in Tank 10H at SRS was dissolved and processed through filters and ion exchange columns. The primary purpose of the process is to remove Cs-137 from the aqueous waste so that it can be disposed as low level waste. It is known that this inorganic media also absorbs strontium from solution, and that strontium competes with cesium ions for absorption sites. The strontium ion is actually more strongly absorbed than the cesium ion from typical tank waste. However, strontium is typically present in low concentrations so does not normally cause a significant impact. Strontium is present as both non-radioactive isotopes and the radioactive Sr-90 isotope; with the non-radioactive isotopes being much more abundant. Although the total strontium solubility is usually much lower than cesium, some tank waste compositions can have a high enough soluble strontium concentration to decrease the cesium absorption. Relatedly, some testing at SRS suggested that another alkaline earth metal, calcium, may also absorb onto CST and may decrease cesium absorption. Barium is also an important species in treatment of tank waste, but is also usually present at low concentrations. However, after the Cs-137 is absorbed onto CST, it emits a beta particle and converts to Ba-137m, which then decays to non-radioactive Ba-137 by emission of a gamma ray. If the Ba-137m were to desorb quickly, it could impact the dose rate in down-stream equipment. In order to understand the impact of these alkaline earth metals on CST, SRNL performed testing using simulants of SRS tank waste that contain soluble barium, strontium, and calcium. Testing examined both removal of the alkaline earth metals and their impact on removal of cesium. Testing involved first developing realistic waste simulant formulations and dissolving the alkaline earth metals to high enough concentrations to potentially impact the Cs absorption. Once the formulations were developed and prepared, computer modeling was used to calculate the expected Cs absorption behavior to determine if the alkaline earth metals impact the performance. Measurements of the alkaline earth metals absorption by the media is also important for disposition of spent media because of the added radionuclide inventory from the Sr-90. These initial tests are examining the general impact and will be used to determine if further testing or measurements are needed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗