Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Challenging Common Assumptions of Thick-Wall Chamber Dynamics in Inertial Fusion Systems Using MOOSE-based Multiphysics Simulations

As an increasing number of companies look toward commercial Inertial Fusion Energy (IFE) designs, there is a pressing need to understand the physics of thick-wall chamber gas dynamics. The thick liquid wall approach implements a renewable wall to mitigate the fusion target emissions, thereby reducing the radiation damage rate and significantly extending the lifetime of chamber structures, leading to increased plant availability and reduced waste streams in comparison to dry wall chamber designs. It is necessary, however, to assess the critical performance and safety aspects of these systems. For example, it is crucial to predict (1) where the mass ablated from the liquid walls will vent, which determines the placement of condensing surfaces; (2) debris propagation up the beam lines, which provides essential information for design and protection requirements; (3) peak pressures and impulse on chamber walls, which affect chamber structural design; and (4) momentum transfer to the liquid jets, which constrains the shape and positioning of the jets. In turn, the chamber design and its liquid walls affect shielding requirements, material activation, and tritium fuel cycle. Currently available simulation tools, however, are unable to accurately capture key thick-wall chamber dynamics. Significant assumptions are often made to simplify the system and reduce computational cost and modeling capability needs, but the impact of these assumptions on simulation predictions has not been evaluated. For example, no three-dimensional simulations can be found in the open literature to evaluate gas venting and momentum transfer to the jets with simulations using two-dimensional domains to represent complex three-dimensional geometries. Moreover, limited studies have been dedicated to jet breakup due to both turbulence and neutron heating, and no studies have been found that evaluate how jet breakup can impact shock-jet interaction. Furthermore, effects of radiative heat transfer have rarely been included for the hydrodynamic phase of shock propagation, and integration of proper equations of state in shock dynamics codes has been mostly exploratory. In this study, we use the flexible, high-fidelity Multiphysics Object-Oriented Simulation Environment (MOOSE) to model these complex phenomena and inform design and safety studies. Capabilities to model thick-wall chamber gas dynamics are being developed, and the impact of the assumptions listed above (i.e., two-dimensional vs three-dimensional, absence of jet breakout, no radiative heat transfer, and ideal gas behavior) are being quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulation of compressible fluid-dynamics in the chamber of inertial fusion energy systems

Here, this paper aims to establish new and innovative modeling capabilities for analyzing chambers in Inertial Fusion Energy (IFE) systems. IFE is emerging as a promising method to achieve fusion power production, but several challenges must be overcome to develop an IFE pilot plant or deploy commercial IFE systems. These challenges are both theoretical and technical, encompassing a deeper understanding of the underlying physical phenomena and the development of new technologies and materials. One of the needs is to develop mathematical models to describe IFE systems and numerical tools to simulate them. This paper contributes to this endeavor by presenting a new OpenFOAM solver for IFE systems, focusing on gas dynamics in their chambers. The analysis and development of chamber designs will play a significant role in the transition from single-shot experiments to high-repetition rates, as there is a need to protect the chamber walls from the intense radiation fields produced by fusion reactions. A promising design option, normally referred to as thick wall chamber design, consists in using lithium or molten salt jet arrays within the chamber. A critical phenomenon is the venting of high-pressure gases from the center to the external part of the chamber, passing through the blanket array. This process involves the propagation and attenuation of strong pressure waves, requiring suitable modeling approaches for compressible fluid-dynamics. The solver proposed in this work implements a multi-material hydrodynamics model tailored to accurately describe the non-linear propagation of pressure waves while avoiding numerical oscillation issues typical of high-velocity compressible simulation. This solver is verified against numerical test cases, validated against experimental data, and applied to the analysis of the High-Yield Lithium-Injection Fusion-Energy (HYLIFE-I) concept. The relevance of this paper is threefold. Firstly, it contributes to developing and testing modeling approaches for compressible fluid-dynamics phenomena, with specific focus on the new and unexplored topic of IFE thick-liquid-wall blanket modeling. Secondly, it marks one of the first applications of the OpenFOAM library in the research field of IFE systems. Finally, the investigated problem is of practical interest for IFE developers, as it provides useful indications about relevant phenomena in pressure wave propagation in the chamber of these systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chamber Interior Viewing System (CIVS 2.0)

The NIF facility is used to conduct fusion and high-density scientific research. The experiments are conducted inside of a 10-meter diameter vacuum chamber called the “Target Chamber”. The target chamber is covered in ports to permit adding equipment to the exterior. Some of this equipment extends into the target chamber such as the target positioners and diagnostics. Other equipment sits on the surface and looks inward, such as the CIVS system. CIVS stands for Chamber Interior Viewing System. The CIVS system provides simple black and white digital images of the interior of the target chamber in real time. These images are used for positioner alignment, trouble shooting and observing for positioner collision. The views through these cameras need to be clear enough for the operators to safely conduct these tasks. One of the products of the experiments conducted in the target chamber are neutrons. These neutrons expand outward from the center of the target chamber with great energy. If the neutrons hit the sensor chip on a digital camera they will “kill” the sensor pixel where they contact, and the result will be a permanently bright white pixel on the image. Over time these “dead” pixels will build up and make the camera less and less usable providing a “staticky” image. The current solution of replacing the cameras when they become damaged is unsustainable due to both the cameras being out of production and the increased rate of camera failure based upon the increased number and energy of neutrons being generated. Current supplies of the correct camera type are dwindling with no source of replacement and the projected rate of replacement is unsustainable. Without a redesign, the function provided by the current CIVS system will be lost.

42 ENGINEERING↗

Passively pumped, polycrystalline ceramic high and ultra-high vacuum chambers

A sealed, passively pumped, polycrystalline ceramic vacuum chamber and method for fabricating the chamber are disclosed. The body of the vacuum chamber is made from a polycrystalline ceramic, for example, alumina. The vacuum chamber includes one or more windows made from a transparent ceramic, for example, sapphire, to accommodate optical access, while remaining amorphous-glass free to minimize or eliminate helium permeation. The vacuum chamber components are joined via laser welding or furnace brazing and the completed chamber is bakeable at temperatures up to 400° C. The vacuum chamber can operate at high or ultra-high vacuum pressures for an extended period through the use of one or more getter-based pumps. The vacuum chamber may include one or more atomic sources depending upon the application.

Walker, Charles A.↗

An experimental and one-dimensional modeling analysis of turbulent gas ejection in pre-chamber engines

In this work, experimental results from a study on the evolution of gas jets ejected through the orifices of a pre-chamber in a heavy-duty optical engine are presented. The work examines conditions without fuel inside the main-chamber, which helps to describe the dynamics of the ejected gas jets without the interference of subsequent combustion in the main-chamber. Experimental diagnostics consist of high-speed visible intensified imaging and low-speed infrared imaging. Additionally a one-dimensional gas jet model is used to characterize the spatial distribution of the ejected flow, including parameters such as tip penetration, which are then validated based on experimental results. Different stages in the ejection of pre-chamber jets are identified, with chemical activity restricted to a maximum distance of 5 to 10 orifice diameters downstream of the orifice as indicated by the recorded visible radiation. Sensitivity of cycle-to-cycle variations in pre-chamber jet development to the air-to-fuel ratio in the pre-chamber observed in the experiments is in most part attributed to the variations in the timing of combustion initiation in the pre-chamber. The influence of the ejection flow on the penetration of the gas jet on a cycle-to-cycle basis is presented using the one-dimensional model. The one-dimensional model also indicates that the local flow exhibits highest sensitivity to operating conditions during the start of ejection until the timing when maximum flow is attained. Differences that exist during the decreasing mass-flow ejection time-period tend to smear out in part due to the transient slowdown of the ejection process.

1-D gas jet model↗

Hybrid combustion modeling approach for turbulent jet ignition in natural-gas pre-chamber spark-ignition engines at high EGR

Here, this study presented a hybrid modeling approach for simulating turbulent jet ignition and combustion processes in a natural-gas pre-chamber spark-ignition engine operating under exhaust gas recirculation (EGR) diluted conditions. In-depth analyses of experimental data and simulation results from previous work [Chinnathambi et al., ICEF2021-67836; Kim et al., Fuel 409: 137815, 2026] revealed two key findings: (i) the magnitude of pressure difference between the pre-chamber and main chamber ($∆P_{PC-MC}$) was positively correlated with the combustion duration from the moment of $∆P_{PC-MC}=0$ to the point of 5% mass fraction burned, with larger $∆P_{PC-MC}$ associated with longer duration; and (ii) the turbulent combustion regime in the main chamber transitioned from the broken reaction zone to the corrugated flamelet regime, with the Karlovitz number exceeding 100 immediately after turbulent hot jets were ejected from nozzles, coinciding with observed local extinction events. To accurately simulate the entire combustion process, a hybrid approach was developed under Reynolds-Averaged Navier Stokes framework, combining the G-equation model for pre-chamber combustion with the multi-zone well-stirred reactor approach and a turbulence-chemistry interaction (TCI) submodel for main chamber combustion. The TCI submodel accounted for the attenuation of reaction rates due to turbulent strain and modeled local extinction by suppressing reaction rates under certain flow and flame conditions. When applied to three EGR rate conditions toward the dilution limit, the hybrid modeling approach accurately reproduced experimental data in terms of cylinder pressure, apparent heat release rate, and the observed positive correlation, including the delayed onset of main chamber combustion—a feature not captured by existing combustion models.

computational fluid dynamics simulation↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Designing a Convection‐Cloud Chamber for Collision‐Coalescence Using Large‐Eddy Simulation With Bin Microphysics

Abstract Collisional growth of cloud droplets is an essential yet uncertain process for drizzle and precipitation formation. To improve the quantitative understanding of this key component of cloud‐aerosol‐turbulence interactions, observational studies of collision‐coalescence in a controlled laboratory environment are needed. In an existing convection‐cloud chamber (the Pi Chamber), collisional growth is limited by low liquid water content and short droplet residence times. In this work, we use numerical simulations to explore various configurations of a convection‐cloud chamber that may intensify collision‐coalescence. We employ a large‐eddy simulation (LES) model with a size‐resolved (bin) cloud microphysics scheme to explore how cloud properties and the intensity of collision‐coalescence are affected by the chamber size and aspect ratio, surface roughness, side‐wall wetness, side‐wall temperature arrangement, and aerosol injection rate. Simulations without condensation and evaporation within the domain are first performed to explore the turbulence dynamics and wall fluxes. The LES wall fluxes are used to modify the Scalar Flux‐budget Model, which is then applied to demonstrate the need for non‐uniform side‐wall temperature (two side walls as warm as the bottom and the two others as cold as the top) to maintain high supersaturation in a tall chamber. The results of LES with full cloud microphysics reveal that collision‐coalescence is greatly enhanced by employing a taller chamber with saturated side walls, non‐uniform side‐wall temperature, and rough surfaces. For the conditions explored, although lowering the aerosol injection rate broadens the droplet size distribution, favoring collision‐coalescence, the reduced droplet number concentration decreases the frequency of collisions.

54 ENVIRONMENTAL SCIENCES↗

Enhancing Turbulent Mixing and Microphysical Uniformity in a Tall Convection‐Cloud Chamber Through Idealized Heterogeneity of Boundaries

A large convection cloud chamber has been proposed for exploring aerosol–cloud–drizzle interactions under well‐controlled turbulent conditions. Recent theoretical and numerical studies suggest that a convection cloud chamber with two heated and two cooled sidewalls can significantly enhance the liquid water content and thus benefit drizzle initiation. However, a chamber with such a sidewall configuration develops stable stratification and extremely weak turbulence therein. In this study, we conduct large‐eddy simulations of a tall convection chamber with five different sidewall configurations consisting of alternating warm and cold patches. For each configuration, the total surface area of warm patches equals that of cold patches, resulting in the same expected cloud‐free supersaturation based on a flux budget model. Results show that changing the sidewall configuration, while keeping all other factors constant, can substantially enhance turbulent mixing and improve the uniformity of thermodynamic and cloud microphysical properties in the bulk region of the chamber. In addition, turbulence strength is positively correlated with liquid water content and negatively correlated with cloud droplet number concentration, consistent with theoretical predictions. Our results highlight the advantage of building a large cloud chamber using modular patches with individually controllable temperature and humidity to achieve well‐mixed conditions.

54 ENVIRONMENTAL SCIENCES↗

Numerical investigation of a fueled pre-chamber spark-ignition natural gas engine

Pre-chamber spark-ignition (PCSI) is a leading advanced ignition concept for internal combustion engines with the potential to enable diesel-like efficiency in medium-duty/heavy-duty (MD/HD) natural gas (NG) engines. By leveraging distributed ignition sources from multiple turbulent jets, the PCSI technology can deliver extremely short combustion duration in ultra-lean mixtures and significantly improve the engine thermal efficiency. However, in the automotive industry there is a lack of adequate science base and predictive simulation tools required for commercial development of PCSI engines. Here, in this study, Reynolds-Average Navier-Stokes simulations are carried out to describe the combustion process in lean-burn NG engines, focusing on the combustion modeling approach. Two combustion models, multi-zone well-stirred reactor (MZ-WSR) and G-equation, are used to simulate the combustion process in an MD NG engine equipped with a fueled-PCSI system for four operating conditions close to the lean operating limit. A skeletal chemical mechanism and a laminar flame speed tabulation are used to compute the combustion accurately. Simulation results are compared with experimental data regarding measured cylinder pressure, heat release rate, and combustion duration. By dividing the PCSI combustion process into four distinct phases, the difference between the two models’ results for each phase is analyzed in detail. The MZ-WSR model overestimates the combustion duration for early flame kernel growth in the pre-chamber due to the lack of a specific formulation to take turbulence-chemistry interaction into account. Despite the prolonged combustion duration and low pressure built-up inside the pre-chamber, the model matches the combustion rate in the main-chamber. In contrast, the G-equation model delivers good agreements for the pre-chamber combustion and turbulent jet-driven combustion processes. However, the model starts to underestimate the combustion rate in the main-chamber, especially under ultra-lean mixture conditions. Finally, improvements are needed for both models to simulate the later combustion stage that occurred in the near-wall regions.

33 ADVANCED PROPULSION SYSTEMS↗

Characterizing the Performance of Fission Chambers for Local Neutron Flux and Spectrum Measurement

Three fission chambers were tested at The Ohio State University Research Reactor (OSURR) to evaluate fission chambers for neutron flux and spectrum measurements. Two of the fission chambers are commercial Photonis CFUR43 fission chambers—one utilizing highly enriched uranium-235 fissile deposits for thermal neutron detection and the other with highly depleted uranium-238 for fast neutron detection. This experiment was also performed in collaboration with French Alternative Energies and Atomic Energy Commission (CEA) with CEA suppling a uranium-235 loaded fission chamber built from the Photonis CFPR CE8/9 kit. The fission chambers were irradiated in a movable 6.5 inch dry tube at reactor powers of 50 kW, 200 kW, and 450 kW at ambient temperature and at 350°C. While all sensors demonstrated good linear sensitivity to reactor power, a leakage current of 6 nA was measured for the CFUR43 detectors. Additionally, the measured signal ratios of the two CFUR43 detectors did not match the theoretical values and are subject to further investigation on individual signal contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Benchmark of Commercial and Developmental Fission Chambers in Elevated Temperatures

This report documents the testing of two in-core fission chamber technologies for high-temperature irradiation environments. This work is in collaboration with the French Alternative Energies and Atomic Energy Commission (CEA). The fission chamber evaluated by Idaho National Laboratory is the micro-pocket fission detector (MPFD). The fission chamber evaluated by the CEA are the 3 mm miniaturized fission chamber and the 7 mm high-temperature fission chamber. Demonstrations of the MPFD were performed at the Neutron Radiography Facility and the Massachusetts Institute of Technology Reactor. Demonstrations of the CEA fission chambers were performed at the Ohio State University Research Reactor. All demonstrations were conducted with a heated experiment rig up to 850°C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmark study of the DTU OWC chamber with both two-way and one-way absorption

This paper reports on a benchmark study based on small-scale (1:50) measurements of a single, oscillating water column chamber mounted sideways in a long flume. The geometry of the OWC chamber is extracted from a barge-like, attenuator-type floating concept “KNSwing” with 40 chambers targeted for deployment in the Danish part of the North Sea. In addition to traditional two-way energy extraction we also consider one-way energy extraction with passive venting and compare chamber response, pressures and total absorbed energy between the two methods. A blind study was established for the numerical modeling, with participants applying several implementations of weakly nonlinear potential flow theory and commercial Navier–Stokes solvers (CFD). Both compressible and incompressible models were used for the air phase. Potential flow calculations predict more energy absorption near the chamber resonance for one-way absorption than for two-way absorption, but the opposite is found from the experimental measurements. This outcome is mainly attributed to energy losses in the experimental passive valve system, but this conclusion must be confirmed by better experimental measurements. Modeling the one-way valve in CFD proved to be very challenging and only one team was able to provide results which were generally closer to the experiments. The study illustrates the challenges associated with both numerical and experimental analysis of OWC chambers. Air compressibility effects were not found to be important at this scale, even with the large volume of additional air used for the one-way case.

16 TIDAL AND WAVE POWER↗

A dynamic solvent chamber propagation estimation framework using RNN for warm solvent injection in heterogeneous reservoirs

Warm solvent injection (WSI), injecting low-temperature solvent into formations to reduce the viscosity of heavy oil, is a clean technology for heavy oil production through reducing greenhouse gas emissions and water usage. The success of WSI operation depends on the uniform development and propagation of solvent chambers in reservoirs. However, reservoir heterogeneity stemming from shale barriers plays a detrimental role in the conformance of solvent chamber development and oil production rate. In this work, we developed a novel recurrent neural network (RNN)-based framework with the capability of efficiently tracking and estimating the solvent chamber positions in heterogeneous reservoirs based on only production time-series data. The developed estimation model utilizes the “sequence-to-sequence" mapping methodology to correlate observed production time-series sequence and solvent chamber edge sequence via a long short-term memory (LSTM) algorithm. The trained RNN models exhibit high accuracy, evidenced by the predicted dynamic solvent chamber locations match the corresponding true locations from numerical simulation, with a high coefficient of determination (R 2 ) and a low mean squared error. Specifically, the achieved R 2 values exceed 0.98 on both the training and testing data. The developed RNN-based workflow was tested via several cases from both regularly- and irregularly-shaped shale barriers, and the results were promising. The predicted solvent chambers showed strong agreement with those obtained from numerical simulations. The major benefits of this workflow include reducing computational time and saving overall monitoring and tracking costs for conventional techniques. In conclusion, the present work would provide a good demonstration of the capability of practical integration of machine learning methods in solving engineering problems.

58 GEOSCIENCES↗

A direct test of Auger cascade induced nucleation from heavy element contamination in C 3 F 8 bubble chambers

Understanding and quantifying the gamma-induced bubble nucleation background in clean nuclear recoil detection bubble chambers is of utmost importance to bubble chamber based dark matter searches. Here, we present data confirming the hypothesis that large Auger cascades from high-Z elements such as iodine and xenon dramatically increase the response of C 3 F 8 bubble chambers to gamma rays. These tests, performed with a small calibration bubble chamber filled with C 3 F 8 +$\mathcal{O}$ (10) ppm xenon, show that the probability of bubble nucleation scales with the rate of xenon inner-shell vacancies, reaching values >10% per K-Shell vacancy for Seitz thresholds of interest to future dark matter searches in bubble chambers. We also place an upper limit on bubble nucleation probability for argon Auger events, relevant to large future bubble chambers which may contain some residual atmospheric argon after the active fluid fill.

47 OTHER INSTRUMENTATION↗

A Scintillating Xenon Bubble Chamber for Dark Matter Detection. Final Report

This report describes the progress in the search for particle dark matter achieved under DOE award DE-SC0012161, as well as the invention of a new dark matter and neutrino detection technique. Work supported by this award follows in three distinct thrusts: (1) the successful completion of the Generation-1 Direct Detection experiment PICO-60, which set the world-leading limit on the spin-dependent coupling of dark matter to protons and achieved a precise understanding of the response of bubble chambers to nuclear-recoil signals and electron-recoil backgrounds; (2) the construction of the Generation-2 Direct Detection experiment LZ, which will soon be the world's most sensitive dark matter detector; and (3) the demonstration of the first scintillating bubble chamber. The development of a scintillating liquid noble bubble chamber was the primary goal of the proposed work, with the aim of combining the excellent background rejection of a PICO-style bubble chamber with the event-by-event energy resolution of a liquid-noble detector such as LZ. This work produced the first ever observation of coincident scintillation and bubble nucleation by a nuclear recoil in a superheated fluid and also revealed an unexpected benefit to the use of noble liquids in a bubble chamber, namely the ability to increase the degree of superheat by an order of magnitude beyond that achievable in PICO-style detectors while maintaining PICO's world-leading background rejection. This discovery has led to new projects in the US and Canada, developing noble liquid bubble chambers both as detectors for low-mass dark matter and as detectors of coherent elastic neutrino-nucleus scattering (CEvNS) by neutrinos produced at nuclear reactors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photo-cleaned Backgroundless Ion Chambers (Final Report for PDRD SR18010)

Ion chambers are often employed to measure the concentration of tritium within flowing gases. In real world environments the active surfaces of ion chambers become covered with tritiated surface contaminants. This tritiated surface contamination will create a large background response that can mask the signature of interest, which is the tritium concentration in the gas phase. Previous efforts to reduce the effects of surface contamination in ion chambers utilize inert coatings (e.g., gold) and low surface area electrodes (e.g., wire mesh), but this route only reduces the effect and does not necessarily alter the ratio of surface contamination to current collection area. Additionally, gold coating may add a substantial cost to the instrument. In the Tritium Facility, ion chambers are periodically cleaned using an alcohol-based process. This process is time consuming and often leads to ion chamber wear and breakage. In addition, periodic cleaning does not address tritium level ambiguities in gloveboxes. An ideal solution to this issue would be to either develop an ion chamber that does not accrue surface contamination, or one that is self-cleaning while it is in operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗