Thermal and Evolved Gas Analysis of Geologic Samples Containing Organic Materials: Implications for the 2007 Mars Phoenix Scout Mission

The Thermal and Evolved Gas Analyzer (TEGA) instrument scheduled to fly onboard the 2007 Mars Phoenix Scout Mission will perform differential scanning calorimetry (DSC) and evolved gas analysis (EGA) of soil samples and ice collected from the surface and subsurface at a northern landing site on Mars. We have been developing a sample characterization data library using a laboratory DSC integrated with a quadrupole mass spectrometer to support the interpretations of TEGA data returned during the mission. The laboratory TEGA test-bed instrument has been modified to operate under conditions similar to TEGA, i.e., reduced pressure (e.g., 100 torr) and reduced carrier gas flow rates. We have previously developed a TEGA data library for a variety of volatile-bearing mineral phases, including Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates. Here we examine the thermal and evolved gas properties of samples that contain organics. One of the primary objectives of the Phoenix Scout Mission is to search for habitable zones by assessing organic or biologically interesting materials in icy soil. Nitrogen is currently the carrier gas that will be used for TEGA. In this study, we examine two possible modes of detecting organics in geologic samples; i.e., pyrolysis using N2 as the carrier gas and combustion using O2 as the carrier gas.

Lauer, H. V., Jr.↗

ECTFE (HALAR) as a New Material for Primary Sample Containment of Astromaterials

Fluoropolymers, such as Teflon® (PTFE, PFA, FEP) and Viton® (FKM), have been used for over 40 years in curating astromaterials at NASA JSC. In general, fluoropolymers have low outgassing and particle shedding properties that reduce cross-contamination to curated samples. Ethylene - Chlorotrifluoroethylene (ECTFE), commonly called Halar® (trademark of Solvay Solexis), is a partially fluorinated semi-crystalline copolymer in the same class of fluoropolymers with superior abrasion resistance and extremely low permeability to liquids, gases, and vapors than any other fluoropolymer (fig. 1). ECTFE coatings are becoming more popular in the nuclear, semiconductor, and biomedical industry for lining isolation containment gloveboxes and critical piping as well as other clean room applications. A study was conducted at NASA JSC to evaluate the potential use of Halar on future sample return missions as a material for primary sample containment.

Calaway, Michael J.↗

Sealed container sampling device

Sampling device, by means of a tapered needle, pierces a sealed container while maintaining the seal and either evacuates or pressurizes the container. This device has many applications in the chemical, preservative and battery-manufacturing industries.

Hennigan, T. J.↗

Preliminary Study of Microfluidic Chip as Sample Containment for Quantitative hiRX Measurements

This is a preliminary report on the development and testing of a microfluidic sample chip for the hiRX prototype instrument test slated for FY14. We used an in-house manufacturing laser-based tool at LANL. This allowed us to change experimental parameters rapidly and generate desired features as needed. The finished product was not a polished commercial grade specimen; however we were able to make these relatively easily and quite rapidly. The performance of these handmade devices was surprisingly good with about 5% RSD for a 1 microliter sample volume.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enclosed Chambers for Humidity Control And Sample Containment in Fiber Diffraction

A chamber and stretch frame for making fibers for diffraction is described. The chamber is made from a simple plastic cuvette with silicon nitride windows. It is suitable for maintaining constant humidity during fiber drying and data collection, and allows stretching of the fiber and exposure to magnetic fields during sample preparation. If necessary, it provides primary containment for toxic and infectious biological materials. The chamber has been used in fiber diffraction experiments with filamentous plant viruses and a yeast prion protein, and is shown to produce excellent orientation and to maintain hydration and order at the molecular level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resonant ultrasound spectroscopy for crystalline samples containing initial strain

Resonant ultrasound spectroscopy (RUS) is a mature and robust technique for the nondestructive characterization of the elastic properties of solids capable of providing the elastic constants of anisotropic crystalline solids. The traditional method is based on assuming that the solid is linear elastic and, therefore, obeys a linearized Hookean constitutive relationship (Hooke’s law). In this work, an alternative constitutive law is provided that allows for an initial strain or prestrain to be present stemming from residual stress. Then, the constitutive relationship is integrated into the RUS framework. The model is demonstrated using a realistic prestrain field obtained by simulating shot-peening processing of a polycrystalline Cu sample. The sensitivity of the resonances to the developed prestrain is established and discussed. This work allows researchers to consider the influence of initial strain or residual stress in their samples and the potential influence on accurate elastic constant estimates. The model also supports the potential of RUS for the nondestructive characterization of prestrain in materials.

42 ENGINEERING↗

Accelerated 133 Xe Quantification in Samples Containing Significant 133 mXe

The quantification of 133 Xe in the presence of its mother radionuclide 133 mXe requires the full quantification of both to perform the ingrowth correction for 133 Xe. Due to the nature of both of these radionuclides, the 133 mXe requires significantly more time to quantify by High Purity Germanium (HPGe) detectors due to lower production yields, lower gamma emission probabilities, and lower detection efficiencies. This work shows that 133 Xe and 133 mXe quantification can be accelerated by measuring the 133m:133 activity ratio for a large batch of material and applying this activity ratio to assays of lower activity subsamples of the same batch of material. Included in this report are derivations of the required decay correction equations, and experiments using actual samples to validate the performance of these equations. A detector calibration method is also shown that leverages this method as an alternative to existing calibration methods for 133 mXe quantification.

133mXe↗

Percentage of Water Retained in Icy Lunar Regolith Simulant During Transfer into a Sample Container

We now know that water ice exists on the lunar surface thanks to the findings of multiple lunar missions such as LRO and LCROSS. However, before we develop systems that can utilize this precious resource at a useful scale, we need to acquire more data about the concentration of water in the lunar regolith and how it may vary by depth and location. The OVEN (Optimized Volatile Extraction Node) system is designed to determine the concentration of water as part of an instrument called WAVE (Water Analysis & Volatile Extraction) which can be deployed during a lunar resource prospecting mission. Experiments were carried out at the Johnson Space Center in order to better understand the potential losses of water that may occur during a prospecting mission when a sample is transferred from a drill to the OVEN. A description of the experiment as well as the results will be presented here.

ISRU↗

Preparation of Mo-Re-C samples containing Mo{sub 7}Re{sub 13}C with the β-Mn-type structure by solid state reaction of planetary-ball-milled powder mixtures of Mo, Re and C, and their crystal structures and superconductivity

Mo-Re-C compounds containing Mo{sub 7}Re{sub 13}C with the β-Mn structure were synthesized with high-melting-temperature metals Mo, Re, and C powders using a conventional solid state method with a planetary ball milling machine instead of the arc melting method. Use of the ball milling machine was necessary to obtain Mo{sub 7}Re{sub 13}C with the β-Mn structure using the solid state method. Almost single-phase Mo{sub 7}Re{sub 13}C with a trace of impurity were obtained using the synthesis method. By XRF and lattice parameter measurements on the samples, Fe element existed in the compound synthesized using the planetary ball milling machine with a pot and balls made of steel, though Fe element was not detected in the compound synthesized using a pot and balls made of tungsten carbide. The former compound containg the Fe atom did not show superconductivity but the latter compound without the Fe atom showed superconductivity at 6.1 K. - Graphical abstract: Temperature dependence of the magnetic susceptibility measured under 10 Oe for the superconducting PBM-T samples without Fe element and non-superconducting PBM-S with Fe element. The inset is the enlarged view of the data for the PBM-S sample.

36 MATERIALS SCIENCE↗

Activation product analysis in a mixed sample containing both fission and neutron activation products

Activation analysis of gold (Au) is used to estimate neutron fluence resulting from a criticality event; however, such analyses are complicated by simultaneous production of other gamma-emitting fission products. Confidence in neutron fluence estimates can be increased by quantifying additional activation products such as platinum (Pt), tantalum (Ta), and tungsten (W). This work describes a radiochemical separation procedure for the determination of these activation products. Anion exchange chromatography is used to separate anionic forms of these metals in a nitric acid matrix; thiourea is used to isolate the Au and Pt fraction, followed by removal of the Ta fraction using hydrogen peroxide. W, which is not retained on the first anion exchange column, is transposed to an HCl/HF matrix to enhance retention on a second anion exchange column and finally eluted using HNO3/HF. Chemical separations result in a reduction in the minimum detectable activity by a factor of 287, 207, 141, and 471 for 182Ta, 187W, 197Pt, and 198Au respectively, with greater than 90% recovery for all elements. These results represent the highest recoveries and lowest minimum detectable activities for 182Ta, 187W, 197Pt, and 198Au from mixed fission-activation product samples to date, enabling considerable refinement in the measurement uncertainties for neutron fluences in highly complex sample matrices.

anion exchange↗

Dual reactor for in situ/operando fluorescent mode XAS studies of sample containing low-concentration 3d or 5d metal elements

Transition metal elements are the most important elements of heterogeneous catalysts used for chemical and energy transformations. Many of these catalysts are active at a temperature higher than 400 °C. For a catalyst containing a 3d or 5d metal element with a low concentration, typically their released fluorescence upon the K-edge or L-edge adsorption of X-rays is collected for the analysis of chemical and coordination environments of these elements. However, it is challenging to perform in situ/operando X-ray absorption spectroscopy (XAS) studies of elements of low-energy absorption edges at a low concentration in a catalyst during catalysis at a temperature higher than about 450 °C. Here a unique reaction system consisting two reactors, called a dual reactor system, was designed for performing in situ or operando XAS studies of these elements of low-energy absorption edges in a catalyst at a low concentration during catalysis at a temperature higher than 450 °C in a fluorescent mode. This dual-reactor system contains a quartz reactor for preforming high-temperature catalysis up to 950 °C and a Kapton reactor remaining at a temperature up to 450 °C for collecting data in the same gas of catalysis. With this dual reactor, chemical and coordination environments of low-concentration metal elements with low-energy absorption edges such as the K-edge of 3d metals including Ti, V, Cr, Mn, Fe, Co, Ni, and Cu and L edge of 5d metals including W, Re, Os, Ir, Pt, and Au can be examined through first performing catalysis at a temperature higher than 450 °C in the quartz reactor and then immediately flipping the catalyst in the same gas flow to the Kapton reactor remained up to 450 °C to collect data. The capability of this dual reactor was demonstrated by tracking the Mn K-edge of the MnO x /Na 2 WO 4 catalyst during activation in the temperature range of 300-900 °C and catalysis at 850 °C.

47 OTHER INSTRUMENTATION↗

A Comparative Study of Single-pulse and Double-pulse Laser-Induced Breakdown Spectroscopy with Uranium-containing Samples

Laser-induced breakdown spectroscopy (LIBS) holds potential advantages in special nuclear material (SNM) sensing and nuclear forensics which require rapid analysis, minimal sample preparation and stand-off distance capability. SNM, such as U, however, result in crowded emission spectra with LIBS, and characteristic emission lines are challenging to discern. It is well-known that double-pulse LIBS (DPLIBS) improves the signal intensity for analytes over conventional single-pulse LIBS (SPLIBS). This study investigates U signal in a glass matrix using DPLIBS and compares to signal features obtained using SPLIBS. DPLIBS involves sequential firing of 1.06 µm Nd:YAG pre-pulse and 10.6 µm TEA CO2 heating pulse in near collinear geometry. Optimization of experimental parameters including inter-pulse delay and energy follows identification of characteristic lines and signals for bulk analyte Ca and minor constituent analyte U for both DPLIBS and SPLIBS. Spatial and temporal coupling of the two pulses in the proposed DPLIBS technique yields improvements in analytical merits with negligible further damage to the sample compared to SPLIBS. Subsequently, the study discusses optimum plasma emission conditions of U lines and relative figures of merit in both SPLIBS and DPLIBS. Investigation into plasma characteristics also addresses plausible mechanisms related to observed U analyte signal variation between SPLIBS and DPLIBS.

Skrodzki, P. J.↗

Finding Interstellar Particle Impacts on Stardust Aluminium Foils: The Safe Handling, Imaging, and Analysis of Samples Containing Femtogram Residues

Impact ionisation detectors on a suite of spacecraft have shown the direction, velocity, flux and mass distribution of smaller ISP entering the Solar System. During the aphelion segments of the Stardust flight, a dedicated collector surface was oriented to intercept ISP of beta = 1, and returned to Earth in January 2006. In this paper we describe the probable appeareance and size of IS particle craters from initial results of experimental impacts and numerical simulation, explain how foils are being prepared and mounted for crater searching by automated acquisition of high magnification electron images (whilst avoiding contamination of the foils) and comment on appropriate analytical techniques for Preliminary Examination (PE).

Kearsley, A. T.↗

Long-term material compatibility testing system

System includes procedure for hermetically sealing solid materials and fluids in glass ampoule and use of temperature-controlled facility containing sample holder, which permits sample containers to be retrieved safely and conveniently. Solid material and fluid are sealed within chemically-clean glass ampoule according to highly detailed procedure.

Toth, L. R.↗