Results for “COOLING TOWERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An algorithmic approach to predicting mechanical draft cooling tower fan speeds from infrasound signals

Mechanical draft cooling towers (MDCTs) serve a critical heat management role in a variety of industries. For nuclear reactors in particular, the consistent, predictable operation of MDCTs is required to avoid damage to infrastructure and reduce the potential for catastrophic failure. Accurate, reliable measurement of MDCT fan speed is therefore an important maintenance and safety requirement. To that end, we have developed an algorithm for automatically predicting the rotational speeds of multiple, simultaneously operating fan rotors using contactless, infrasound measurements. The algorithm is based on identifying the blade passing frequencies (BPFs), their harmonics, as well as the motor frequencies (MFs) for each fan in operation. Using the algorithm, these frequencies can be automatically identified in the acoustic waveform’s short-time Fourier transform spectrogram. Attribution is aided by a set of filters that rely on the unique spectral and temporal characteristics of fan operation, as well as the intrinsic frequency ratios of the BPF harmonics and the BPF/MF signals. The algorithm was tested against infrasound data acquired from infrasound sensors deployed at two research reactors: the Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL) and the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory (ORNL). After manually identifying the MDCT gearbox ratio, the algorithm was able to quickly yield fan speeds at both reactors in good agreement with ground truth. Ultimately, this work demonstrates the ease by which MDCT fans may be monitored in order to optimize operational conditions and avoid infrastructure damage.

42 ENGINEERING↗

Ozone Treatment For Cooling Towers

Report presents results of study of cooling tower in which water treated with ozone instead of usual chemical agents. Bacteria and scale reduced without pollution and at low cost. Operating and maintenance costs with treatment about 30 percent of those of treatment by other chemicals. Corrosion rates no greater than with other chemicals. Advantage of ozone, even though poisonous, quickly detected by smell in very low concentrations.

Blackwelder, Rick↗

Analysis of heat and mass transfer potential of a dew-point cooling tower in different climatic conditions

In this study, the performance of the Dew-Point Cooling Tower (DPCT) was analyzed for different factors in a variety of climate conditions. For this purpose, a dedicated numerical model describing heat and mass transfer processes was developed and validated. The results of the numerical simulations allowed to analyze the potential of utilizing the heat and mass transfer process with the dew-point phenomenon for water cooling. It was established that the operational parameters that have a high impact on the performance of the DPCT are: inlet water temperature and inlet air humidity ratio. It was also established that DPCT achieves the highest COP and Specific Cooling Capacity for cold subtropical highland climates and that it achieves highest Wet-bulb Effectiveness for monsoon-influenced humid subtropical climates. In conclusion, the regions where all the efficiency factors achieved above-average values included warm, arid, and desert climates.

42 ENGINEERING↗

METSiCloPs in Cooling Tower Water, Final Presentation: Water Treatment at FSI [Slides]

Motivation: According to current projections, FSI could require anywhere from 83-288 MGY of water. Reducing excessive dependence on external water supply by making operations as water-lean as possible in the face of water availability fluctuations seasonally. The amount of Silica occurring naturally in New Mexico is several multiples higher than most of the country, with average values of 90 ppm, but reaching as high as 113 ppm. Since its saturation concentration at ambient temperatures is about 150 ppm, this corresponds to cycles of concentration as low as 1-2 for untreated water in cooling towers (i.e., the water is circulated through the towers only once or twice before they are dumped into the outfall), thereby making operations highly water intensive. There is, therefore, there is a strong need and internal motivation to remove Silica from the water that is circulated in the cooling towers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ozone inhibits corrosion in cooling towers

Commercially available corona discharge ozone generator, fitted onto industrial cooling tower, significantly reduces formation of scales (calcium carbonate) and corrosion. System also controls growth of algae and other microorganisms. Modification lowers cost and improves life of cooling system.

French, K. R.↗

Blowdown Recovery System for Cooling Tower Water Treatment

From 2014-2017, the U.S. General Services Administration's (GSA's) average nationwide water rates increased 41%. Rapidly escalating costs, mandated water-reduction targets, and the fact that an average of 28% of commercial office building water use is associated with heating and cooling led the GSA Green Proving Ground program to select alternative water treatment technologies for in-field validation. This report summarizes the latest alternative water treatment evaluation completed in 2022 - a Blowdown Recovery System for Cooling Tower Water Treatment. This Green Proving Ground program project assessed the performance of an alternative water treatment system provided by Aqualogix for treating cooling tower blowdown at the Lloyd D. George U.S. Courthouse in Las Vegas, Nevada.

13 HYDRO ENERGY↗

Ozonation of cooling tower waters

Continuous ozone injection into water circulating between a cooling tower and heat exchanger with heavy scale deposits inhibits formation of further deposits, promotes flaking of existing deposits, inhibits chemical corrosion and controls algae and bacteria.

Humphrey, M. F.↗

CONDENSATION-EVAPORATION MODELING OF DRIFT FROM A MECHANICAL COOLING TOWER

Numerical studyfor investigatingthe phase change behavior of a drift from a mechanical draft cooling tower is presented. A k-ε turbulence model, discrete phase model, species transport equations, and a heat-mass exchange model are solved simultaneouslyto capture the heat and mass transfer effects of a drift condensing and evaporatingeffects. The simulation result is compared to an available real scale test data and its limitation is also discussed. A parametric study is carried out by varying the ambient dry bulb temperature, ambient relative humidity, wind speed, liquid droplet diameter, and the drift amount. It is found that by combining the evaporation and condensation models, a drift phase change phenomena is accurately depicted. A parametric study reveals that wind speed impact is affected by the ambient temperature and the number of liquid droplets and their size play a critical role in the phase change phen

Han, Kai↗

Zero Liquid Discharge and Water Reuse in Recirculating Cooling Towers at Power Facilities: Review and Case Study Analysis

Zero liquid discharge (ZLD) systems installed at power facilities with the primary purpose of meeting water discharge regulations have the added benefit of providing high quality effluent that can be reused in the facility. This paper provides a review of water use in power sector recirculating cooling towers and a baseline assessment of on-site water reuse at natural gas combined cycle (NGCC) power facilities. Two NGCC facilities with reverse-osmosis (RO) or brine-concentrator processes followed by evaporation ponds were selected as case studies; data from these facilities were used to quantify the water, energy, and cost implications of implementing conventional and emerging ZLD technologies. At one case study facility, model results show that implementation of ZLD would reduce water withdrawals by 18%, which is less than savings associated with implementation of dry cooling but comparable to current efforts to reduce water withdrawals by increasing cycles of concentration. Implementation of ZLD using high-recovery RO resulted in a doubling of the levelized cost of water (LCOW). LCOW increased more when a brine concentrator was used. For both case studies, the ZLD system using high-recovery RO required less than 0.1% of a facilitiy's annual electricity generation and the ZLD system using a brine concentrator process required less than 0.8%. Additionally, increasing the evaporation pond area to minimize required ZLD system recovery rates and reduce system electricity costs does not reduce the LCOW. Instead, the LCOW increases because less water is recovered and more water is lost to evaporation. Furthermore, if water availability decreases or water competition/cost increases, facilities may be incentivized to maximize water recovery from ZLD systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrocoagulation Combined with Ultrafiltration Membranes as Pretreatment for RO Desalination of Synthetic Cooling Tower Blowdown Water

Electrocoagulation (EC), an electrochemical water treatment process, is commonly used to remove particulate and colloidal matter from water. Here, in this study, we demonstrate that EC, when coupled with membrane filtration, is also capable of removing dissolved species, such as Ca + , Mg 2+ , and SiO x . The removal of such species is important for downstream membrane-based desalination treatment of the water that can suffer from reduced performance due to membrane scaling. Here, we describe how EC can be combined with a low-pressure membrane (LPM) system to offer efficient (and potentially universal) pretreatment for downstream membrane desalination. Synthetic water, simulating cooling tower blowdown (CTBD) with elevated concentrations of hardness and silicates (Ca: 418 ppm, Mg: 63 ppm, SiO 2 : 50 ppm) is treated using EC coupled to ultrafiltration (UF) to remove Mg up to 30 ± 1%, Ca up to 29 ± 1%, and silica up to 99 ± 1%. We evaluated the effectiveness of the EC-UF pretreatment system in reducing downstream RO scaling using thermodynamic modeling to predict the saturation index (SI) at the RO membrane/water interface. An SI value below zero (SI < 0) indicates under-saturated conditions (with respect to a particular mineral) where mineral scaling does not take place, which correlates with improved water recovery. Our findings suggest that the EC-UF pretreatment system was able to increase water recovery by up to 30%, compared to 0% recovery without pretreatment, under optimal conditions (feed solution pH of 7 and an EC charge loading of 1800 C/L). Finally, we conducted an economic analysis showing that implementing an EC-UF system for CTBD water could yield a cost benefit of up to $\$$14.13 per m 3 compared to direct brine disposal.

cooling tower blowdown↗

Biofilm growth in water-cooling towers as collection platforms for airborne radionuclides

Given its history of nuclear material processing, the Savannah River Site (SRS) was used to evaluate whether biofilms growing in water-cooling towers (WCTs) are effective passive collection platforms for environmental radionuclide surveillance. Uranium and plutonium analyses suggest that WCT-sourced biofilms are efficient, indigenous, constantly running samplers that can be used for environmental monitoring, as their isotopic compositions are distinct from atmospheric fallout and representative of SRS historical activities. Further, the ubiquity of WCTs worldwide and demonstrated ability to detect nuclear material processing and constrain specific activities based on biofilm actinide isotopic compositions make WCT biofilms a promising means to improve monitoring.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Management, Efficiency and Treatment of Silica, Chlorides, and other Pollutants (METSiCloPs) of Cooling Tower Water [Slides]

Site-wide water balance suggests that CTs across eight LANL facilities use about 58% of the total potable water bought from LAC (271 MGY). It is vital to make a conscious and calculated effort to reduce the dependence on external water supplies, and potable water.We need to strive to increase CoCs at CTs and improve water efficiency to reduce water consumption.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hygroscopic cooling tower for waste water disposal

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid integrating waste water as makeup water. The present invention also relates to methods of using the same. The present invention also relates to hygroscopic cooling systems adapted to dispose of waste water by combining the waste water with a hygroscopic working fluid, precipitating impurities and evaporating the remaining water.

Martin, Christopher Lee↗

Hygroscopic cooling tower for waste water disposal

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid integrating waste water as makeup water. The present invention also relates to methods of using the same. The present invention also relates to hygroscopic cooling systems adapted to dispose of waste water by combining the waste water with a hygroscopic working fluid, precipitating impurities and evaporating the remaining water.

Martin, Christopher Lee↗

Locating Operational Events of the Cooling Tower of a Nuclear Reactor with a Very Local Seismic Network

Geolocation of emergent seismic signals is challenging at close distances. Here, we used three-component data from a seismic network and a targeted experiment at a research nuclear reactor to locate seismic sources. Utilizing known events collected during the targeted experiment, we were able to infer source locations with seismic amplitudes and polarization characteristics of the data. Although the resolution of the source location is not perfect, the seismic amplitudes and polarization analysis offer useful constraints. For the known events, the source region inferred with our analysis includes the true source locations. Synthetic tests indicate the resolution is largely due to limited data coverage and measurement uncertainties because the synthetic tests show similar results compared with the field data. We identified the source of the unknown event through spectrum cross correlation between the signals from the known events and an unknown event. Our findings were confirmed by operational staff at the facility. When the propagation medium properties (i.e., seismic velocity and quality factor for attenuation) are known, our analysis can be applied to continuous data from a seismic array to infer both source amplitude and location. If the medium properties are not known, a targeted experiment can be conducted to estimate them.

58 GEOSCIENCES↗