At least 19 records

Field Validation of Electrochemical Water Filtration System on Open Loop Cooling Towers at Automotive Plants

Open loop cooling towers play a pivotal role in rejecting heat for chilled water systems serving industrial processes, heating, ventilation, and air conditioning loads. Exposure to outside conditions can present certain operating challenges to system performance including scaling, corrosion, and biological growth. These issues are mitigated through the use of effective cooling tower water filtration and treatment systems to reduce contaminants—along with other total suspended solids (TSS) and total dissolved solids (TDS)—in the system. The U.S. Department of Energy’s Industrial Efficiency and Decarbonization Office is interested in an electrochemical-based filtration system with the ability to remove TSS particulate down to 1 micron. The removal of finer particulates reduces the need for blowdown and, in turn, makeup water use and chemical treatment in the cooling tower. Additionally, the removal process can reduce fouling at the condensers, resulting in better heat exchange and energy savings. Two Industrial Technology Validation program projects validated the electrochemical water filtration system at the Toyota Motor Manufacturing, Mississippi plant in Blue Springs, Mississippi, and the Nissan Canton Vehicle Assembly Plant in Canton, Mississippi. Researchers found that installation of both systems resulted in water and chemical treatment savings with minimal impact on energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Water Production in Cooling Towers

This project developed and demonstrated a novel technology that produces clean water from cooling tower recirculating water by using the natural evaporation and condensation cycle inside cooling towers. The system captures the escaping plume and converts blowdown quality water into high purity water suitable for on-site reuse such as boiler feed. The technology uses electric fields to ionize exhaust plumes, charge the entrained droplets, and direct them toward collection electrodes where they coalesce and flow downward. This allows water recovery at a low energy cost while reducing visible plume emissions. In addition, we developed a complementary software platform that improves overall cooling tower performance. The system uses wireless sensors and physics-based machine learning algorithms to optimize key parameters of the cooling process. For power generation facilities, this increases the thermal efficiency of the cooling loop and condenser, resulting in measurable cycle efficiency gains. Improvements of one percent or more can deliver significant increases in electricity production for the same fuel input.

01 COAL, LIGNITE, AND PEAT↗

Exploring the Potential of Rainwater Harvesting for Cooling Towers: A Systematic Review and Regional Feasibility Assessment

Water scarcity has driven interest in rainwater harvesting, especially for U.S. industries like power and manufacturing, which dedicate a large percentage of their water needs to cooling towers. This paper provides a comprehensive systematic review of studies on the use of rainwater in cooling tower applications, along with an assessment of the regional feasibility of integrating RWH in U.S. manufacturing cooling towers. The systematic review examines the technical, economic, environmental, and policy feasibility of utilizing harvested rainwater, and the regional feasibility analysis evaluates the practical implementation of RWH in manufacturing cooling towers, considering factors such as regional RWH potential, water costs, state policies, and the industrial water use of manufacturing facilities per state. This study supports the hypothesis that RWH for cooling towers is technically feasible, economically viable, and environmentally beneficial. Harvested rainwater is naturally less conductive and soft, and rainwater reuse minimizes the ecological footprint. Supportive state policies, regional RWH potential, and rising water costs across the U.S. are important variables that may impact RWH adoption. The review highlights rooftop RWH as the most studied method and notes that implementing RWH requires infrastructure changes and filtration techniques. While initial investment costs may be high, operational and maintenance costs are low, making RWHS economically feasible over time. Regions with higher water costs and supportive policies are more likely to benefit from RWH adoption. The study provides a foundation for understanding the potential for using RWH in industrial cooling towers.

Cooling towers↗

Cooling tower water conditioning study

Successful elimination of cooling tower treatment chemicals was demonstrated. Three towers functioned for long periods of time with ozone as the only treatment for the water. The water in the systems was reused as much as 30 times (cycles of concentration) without deleterious effects to the heat exchangers. Actual system blow-down was eliminated and the only makeup water added was that required to replace the evaporation and mist entrainment losses. Minimum water savings alone are approximately 75.1 1/kg/year. Cost estimates indicate that a savings of 55 percent was obtained on the systems using ozone. A major problem experienced in the use of ozone for cooling tower applications was the difficulty of accurate concentration measurements. The ability to control the operational characteristics relies on easily and accurately determined concentration levels. Present methods of detection are subject to inaccuracies because of interfering materials and the rapid destruction of the ozone.

Humphrey, M. F.↗

Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate

In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified ε-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Electrochemical Water Filtration System on an Open Loop Cooling Tower at Nissan Manufacturing Plant in Canton, Mississippi

The U.S. Department of Energy Industrial Efficiency and Decarbonization Office’s Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized technologies in the industrial sector to help inform decisions towards accelerating commercialization and deployment. This ITV demonstration investigated the performance of an early-commercial electrochemical water treatment technology on a cooling tower at an automotive plant. Cooling towers are vital equipment for dissipating heat from industrial processes, but they face challenges related to scaling, corrosion, and the growth of biological contaminants. Effective cooling tower water treatment is therefore essential in reducing these contaminants and other total suspended solids (TSS) and total dissolved solids (TDS). Various treatment systems, such as sand-based filters, centrifugal separators, and disc filters are available, each having its advantages and drawbacks. ElectroCell Systems, a filtration technology provider, offers an electrochemistry-based water treatment system that is skid-mounted and can be configured as a side-stream filtration system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ozone Treatment For Cooling Towers

Report presents results of study of cooling tower in which water treated with ozone instead of usual chemical agents. Bacteria and scale reduced without pollution and at low cost. Operating and maintenance costs with treatment about 30 percent of those of treatment by other chemicals. Corrosion rates no greater than with other chemicals. Advantage of ozone, even though poisonous, quickly detected by smell in very low concentrations.

Blackwelder, Rick↗

Analysis of heat and mass transfer potential of a dew-point cooling tower in different climatic conditions

In this study, the performance of the Dew-Point Cooling Tower (DPCT) was analyzed for different factors in a variety of climate conditions. For this purpose, a dedicated numerical model describing heat and mass transfer processes was developed and validated. The results of the numerical simulations allowed to analyze the potential of utilizing the heat and mass transfer process with the dew-point phenomenon for water cooling. It was established that the operational parameters that have a high impact on the performance of the DPCT are: inlet water temperature and inlet air humidity ratio. It was also established that DPCT achieves the highest COP and Specific Cooling Capacity for cold subtropical highland climates and that it achieves highest Wet-bulb Effectiveness for monsoon-influenced humid subtropical climates. In conclusion, the regions where all the efficiency factors achieved above-average values included warm, arid, and desert climates.

42 ENGINEERING↗

Ozone inhibits corrosion in cooling towers

Commercially available corona discharge ozone generator, fitted onto industrial cooling tower, significantly reduces formation of scales (calcium carbonate) and corrosion. System also controls growth of algae and other microorganisms. Modification lowers cost and improves life of cooling system.

French, K. R.↗

Ozonation of cooling tower waters

Continuous ozone injection into water circulating between a cooling tower and heat exchanger with heavy scale deposits inhibits formation of further deposits, promotes flaking of existing deposits, inhibits chemical corrosion and controls algae and bacteria.

Humphrey, M. F.↗

Electrocoagulation Combined with Ultrafiltration Membranes as Pretreatment for RO Desalination of Synthetic Cooling Tower Blowdown Water

Electrocoagulation (EC), an electrochemical water treatment process, is commonly used to remove particulate and colloidal matter from water. Here, in this study, we demonstrate that EC, when coupled with membrane filtration, is also capable of removing dissolved species, such as Ca + , Mg 2+ , and SiO x . The removal of such species is important for downstream membrane-based desalination treatment of the water that can suffer from reduced performance due to membrane scaling. Here, we describe how EC can be combined with a low-pressure membrane (LPM) system to offer efficient (and potentially universal) pretreatment for downstream membrane desalination. Synthetic water, simulating cooling tower blowdown (CTBD) with elevated concentrations of hardness and silicates (Ca: 418 ppm, Mg: 63 ppm, SiO 2 : 50 ppm) is treated using EC coupled to ultrafiltration (UF) to remove Mg up to 30 ± 1%, Ca up to 29 ± 1%, and silica up to 99 ± 1%. We evaluated the effectiveness of the EC-UF pretreatment system in reducing downstream RO scaling using thermodynamic modeling to predict the saturation index (SI) at the RO membrane/water interface. An SI value below zero (SI < 0) indicates under-saturated conditions (with respect to a particular mineral) where mineral scaling does not take place, which correlates with improved water recovery. Our findings suggest that the EC-UF pretreatment system was able to increase water recovery by up to 30%, compared to 0% recovery without pretreatment, under optimal conditions (feed solution pH of 7 and an EC charge loading of 1800 C/L). Finally, we conducted an economic analysis showing that implementing an EC-UF system for CTBD water could yield a cost benefit of up to $\$$14.13 per m 3 compared to direct brine disposal.

cooling tower blowdown↗

Biofilm growth in water-cooling towers as collection platforms for airborne radionuclides

Given its history of nuclear material processing, the Savannah River Site (SRS) was used to evaluate whether biofilms growing in water-cooling towers (WCTs) are effective passive collection platforms for environmental radionuclide surveillance. Uranium and plutonium analyses suggest that WCT-sourced biofilms are efficient, indigenous, constantly running samplers that can be used for environmental monitoring, as their isotopic compositions are distinct from atmospheric fallout and representative of SRS historical activities. Further, the ubiquity of WCTs worldwide and demonstrated ability to detect nuclear material processing and constrain specific activities based on biofilm actinide isotopic compositions make WCT biofilms a promising means to improve monitoring.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗