Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Use of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

Computed Tomography (CT) has advanced considerably since being responsible for such dramatic advances in diagnostics within the medical field. It has become a major tool in non destructive evaluation (NDE), and is used in many fields as diverse as coal-mining to metal solidification to examination of rock cores. A review of industrial applications has been written by Dennis. It is only recently that the technique has been seriously used to determine composition through precise measurement of density. While such applications are restricted to cases when there is no ambiguity in the relationship of composition to density. Thus alloy solid solutions lend themselves to compositional analysis provided there is a large change in density with composition. The technique is most useful when rapid non-destructive evaluation is needed. Such cases will occur with samples returning from the International Space Station (ISS) when knowledge of the results could affect future strategies for processing of on-board samples. Experiments from those Principal Investigators (PI) that are most likely to benefit from early CT scanning are discussed. With a dearth of samples, the major emphasis in the first part of this project has been on preparing suitable standards, optimizing the CT technique for these applications, and using the CT system to determine density variations with temperature. An interesting application of CT has been in the examination of meteorites, which can be classified as space-grown materials and will certainly have solidified in a low gravity environment.

Gillies, Donald C.↗

Assessment of Localized Deformations in Sand Using X-Ray Computed Tomography

The internal fabric and localized deformation patterns of triaxial sand specimens were investigated using Computed Tomography (CT). Three displacement-controlled, conventional, drained axisymmetric (triaxial) experiments were conducted on dry Ottawa sand specimens at very low effective confining stresses (0.05, 0.52, and 1.30 kPa) in a microgravity environment aboard the Space Shuttle during the NASA STS-79 mission. CT scanning was p'erformed on these flight specimens, as well as on an uncompressed specimen and a specimen tested in a terrestrial laboratory at 1.30 kPa effective confining stress. CT demonstrated high accuracy in detecting specimen inhomogeneity and localization patterns. Formation of deformation patterns is dependent on the effective confining stress and gravity. Multiple symmetrical radial shear bands were observed in the specimens tested in a microgravity environment. In the axial direction, two major conical surfaces were developed. Nonsymmetrical spatial deformation was observed in the 1-G specimen. Analysis tools were developed to quantify the spatial density change. Void ratio variation within and outside the shear bands was calculated and discussed.

Alshibli, Khalid A↗

Sub-regional Assessment of Bone Loss in the Axial Skeleton in Long-Term Spaceflight

No scanning was performed this month. At this point, 14 subjects are enrolled in the program 11 have received baseline measurements. Five subjects have completed the pre-flight and return CT scans. The accomplishments of the study up to this point are described in the Operational Accomplishments Report submitted to Dr. Lakshmi Putcha for the Increment 3 flight.

Lang, Thomas F.↗

Non-Destructive Testing Scanner

Bio-Imaging Research's technology that originated in an aerospace program has come full circle with a new aerospace adaptation called the Advanced Computed Tomography Inspection System, or ACTIS. The medical version of CT scans the human body for tumors or other abnormalities, the ACTIS system finds imperfections in aerospace structures and components, such as castings, assemblies, rocket motors and nozzles. ACTIS is described by its developer as the most versatile CT scanner available for non-destructive testing applications. ACTIS is a variable geometry system. ACTIS source and detectors can be moved closer together or farther apart to optimize the geometry for different sizes of test objects. The combination of variable geometry, three sources, and focusing detectors makes ACTIS cost effective for a broad range of applications. System can scan anything from very small turbine blades to large rocket assemblies.

Source record↗

Preserving, Enhancing, and Continuing the Scientific Legacy of the Apollo Sample Suite

From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six geologically diverse locations on the Moon. In the nearly 50 years since the samples were collected, over 3000 different studies have been conducted using the nearly 2200 different Apollo samples. Despite the maturity of the sample collection, many new studies of lunar samples are undertaken each year, with an average of more than 55 requests and more than 600 distinct subsamples allocated annually over the past five years. The Apollo samples are a finite resource, however. Although new studies are encouraged, it is important that new studies do not duplicate previous studies, and where possible, leverage previous results to inform and enhance the current studies. This helps to preserve the samples and scientific funding, both of which are precious resources. We have initiated several new efforts to rescue some of the early analyses from these samples, including unpublished analytical data. We are actively scanning NASA documentation in paper form that is related to the Apollo missions and sample processing, and we are collaborating with IEDA to establish a geochemical data base called MoonDB. To populate this database, we are actively working with about a dozen prominent lunar PIs to organize and transcribe years of both published and unpublished data, making it available to all researchers. This effort will also take advantage of new online analytical tools like PetDB. There have already been tangible results from the MoonDB data rescue effort. A pilot project involving the rescue of geochemical data of John Delano on Apollo pyroclastic glasses has already been referenced in multiple Apollo sample requests, and in fact, the compiled data was used as part of one of the new studies. Similarly, scanned sample handling reports have been utilized to find previously analyzed samples that were appropriate to fulfill new sample requests. We have also begun to image the Apollo samples using (1) micro‐CT scanning to document the interior structure of samples, and (2) comprehensive high resolution photography of samples, enabling high resolution 3D reconstructions of the samples. Both efforts will provide comprehensive access to these samples and allow for more targeted requests, and thus better curation of the samples for decades to come.

Zeigler, Ryan↗

Computed Tomography 3-D Imaging of the Metal Deformation Flow Path in Friction Stir Welding

In friction stir welding (FSW), a rotating threaded pin tool is inserted into a weld seam and literally stirs the edges of the seam together. To determine optimal processing parameters for producing a defect free weld, a better understanding of the resulting metal deformation flow path is required. Marker studies are the principal method of studying the metal deformation flow path around the FSW pin tool. In our study, we have used computed tomography (CT) scans to reveal the flow pattern of a lead wire embedded in a FSW weld seam. At the welding temperature of aluminum, the lead becomes molten and is carried with the macro-flow of the weld metal. By using CT images, a 3-dimensional (3D) image of the lead flow pattern can be reconstructed. CT imaging was found to be a convenient and comprehensive way of collecting and displaying tracer data. It marks an advance over previous more tedious and ambiguous radiographic/metallographic data collection methods.

Schneider, Judy↗

Preserving the Science Legacy from the Apollo Missions to the Moon

Six Apollo missions landed on the Moon from 1969-72, returning to Earth 382 kg of lunar rock, soil, and core samples-among the best documented and preserved samples on Earth that have supported a robust research program for 45 years. From mission planning through sample collection, preliminary examination, and subsequent research, strict protocols and procedures are followed for handling and allocating Apollo subsamples. Even today, 100s of samples are allocated for research each year, building on the science foundation laid down by the early Apollo sample studies and combining new data from today's instrumentation, lunar remote sensing missions and lunar meteorites. Today's research includes advances in our understanding of lunar volatiles, lunar formation and evolution, and the origin of evolved lunar lithologies. Much sample information is available to researchers at curator.jsc.nasa.gov. Decades of analyses on lunar samples are published in LPSC proceedings volumes and other peer-reviewed journals, and tabulated in lunar sample compendia entries. However, for much of the 1969-1995 period, the processing documentation, individual and consortia analyses, and unpublished results exist only in analog forms or primitive digital formats that are either inaccessible or at risk of being lost forever because critical data from early investigators remain unpublished. We have initiated several new efforts to rescue some of the early Apollo data, including unpublished analytical data. We are scanning NASA documentation that is related to the Apollo missions and sample processing, and we are collaborating with IEDA to establish a geochemical database called Moon DB. To populate this database, we are working with prominent lunar PIs to organize and transcribe years of both published and unpublished data. Other initiatives include micro-CT scanning of complex lunar samples to document their interior structure (e.g. clasts, vesicles); linking high-resolution scans of Apollo film products to samples; and new procedures for systematic high resolution photography of samples before additional processing, enabling detailed 3D reconstructions of the samples. All of these efforts will provide comprehensive access to Apollo samples and support better curation of the samples for decades to come.

Evans, Cindy↗

Quantifying Void Ratio Variation in Sand using Computed Tomography

A series of displacement-controlled, conventional, drained axisymmetric (triaxial) experiments were conducted on dry Ottawa sand specimens at very low effective confining stresses in a microgravity environment aboard the Space Shuttle during the NASA STS-89 mission. Post-flight analysis included studying the internal fabric and failure patterns of these specimens using Computed Tomography (CT). The CT scans of three specimens subjected to different compression levels (uncompressed specimen, a specimen compressed to 3.3% nominal axial strain (epsilon(sub a)), and a specimen compressed to 25% epsilon(sub a)) are presented to investigate the evolution of instability patterns and to quantify void ratio variation. The progress of failure is described and discussed. Also, specimens' densities were calibrated using standard ASTM procedures and void ratio spatial variation was calculated and represented by contour maps and histograms. The CT technique demonstrated good ability to detect specimen inhomogeneities, localization patterns, and quantifying void ratio variation within sand specimens.

Alshibli, Khalid A.↗

A Procedure to Quantify Interlaminar Damage in Refractory Composites by In-Situ Micro-X-Ray Computed Tomography

Refractory composites are relevant for hot-structure applications on re-entry vehicles. To develop optimized high-performance hot structures, accurate material property data is required. Material properties that often limit design in two-dimensional (2-D) composites are interlaminar strengths. A better understanding of the failure mechanisms for interlaminar shear (ILS), interlaminar tension (ILT), and curved-beam interlaminar tension (CB-ILT) tests can provide insight on improving the design and fabrication of refractory composites. In-situ tests were performed to capture the progressive failure in American Society for Testing and Materials (ASTM) sized ILS (ASTM D3846), ILT (ASTM D7291), and CB-ILT (ASTM D6415) specimens. Before measuring internal damage of refractory composites specimens, the methodology of the test setup warrants a complete and thorough discussion. Detail on the test procedure, test stand design, micro-x-ray computed tomography (CT) configuration, data processing, and CT system uncertainty is discussed. Through keeping the many parameters of the CT system consistent, the uncertainty of the CT system was minimized, optimizing the quality of measurements. The overall quality of a CT scan can be quantified by three metrics: voxel resolution, minimal voxel resolution feature detection, and directional variability. A better understanding of the progressive failure mechanisms of refractory composites is provided by the results of both the present discussion and the one found in the accompanying paper titled “Analysis of Interlaminar Damage in Refractory Composites by In-Situ Micro-X-Ray Computed Tomography”.

In-situ micro-x-ray CT↗

Characterization and Modeling of Cell Wall Imperfections in Aluminum Honeycomb Cores using X-ray CT Imaging

Honeycomb cell imperfections may significantly affect the failure of sandwich composites in core crushing and shear modes. Identification and quantification of the different types of imperfections and evaluation of their effects on the mechanical response of honeycomb cores in flatwise compression is presented. X-Ray computed tomography (CT) scans of honeycomb cores in co-cured composite sandwich panels were performed. Image analysis methods are applied to characterize and quantify core cell geometry and cell wall waviness. An approach is developed for extracting cell wall mid surface planes and waviness for constructing finite element models using shell elements. Analysis results from models with the as-manufactured imperfections are compared to results from models with idealized geometries to evaluate the effect of the as-manufactured imperfections on the initiation of cell wall buckling and subsequent core crushing.

aluminum honeycomb↗

Application of Radon Transform to Multi-Angle Measurements Made by the Research Scanning Polarimeter: A New Approach to Cloud Tomography. Part I: Theory and Tests on Simulated Data.

The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP was a prototype for the Aerosol Polarimetry Sensor (APS) launched on-board the NASA Glory satellite. Currently the retrieval algorithms developed for the RSP are being adopted for the measurements of the space-borne polarimeters on the upcoming NASA’s Plankton, Aerosol, Cloud Ocean Ecosystem (PACE)satellite mission. The RSP’s uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid water cloud droplet sizes using the polarized rainbow structure. It also provides geometric constraints on the cumulus cloud’s 2D cross section yielding the cloud’s geometric shape estimates. In this study we further build on the latter technique to develop a new tomographic approach to retrieval of cloud internal structure from remote sensing measurements. While tomography in the strict definition is a technique based on active measurements yielding a tomogram (directional optical thickness as a function of angle and offset of the view ray), we developed a “semi-tomographic” approach in which tomogram of the cloud is estimated from passive observations instead of being measured directly. This tomogram is then converted into 2D spatial distribution of the extinction coefficient using inverse Radon transform (filtered back projection) which is the standard tomographic procedure used e.g., in medical CT scans. This algorithm is computationally inexpensive compared to techniques relying on highly-multi-dimensional least-square fitting; it does not require iterative 3D RT simulations. The resulting extinction distribution is defined up to an unknown constant factor, so we discuss the ways to calibrate it using additional independent measurements. In the next step we use the profile of the droplet size distribution parameters from the cloud’s side (derived by fitting the polarized rainbows) to convert the 2D extinction distribution into that of the droplet number concentration. We illustrate and validate the proposed technique using 3D-RT-simulatedRSP observations of a LES-generated Cu cloud. Quantitative comparisons between the retrieved and the original optical and microphysical parameters are presented.

clouds↗

Optimal design of composite hip implants using NASA technology

Using an adaptation of NASA software, we have investigated the use of numerical optimization techniques for the shape and material optimization of fiber composite hip implants. The original NASA inhouse codes, were originally developed for the optimization of aerospace structures. The adapted code, which was called OPORIM, couples numerical optimization algorithms with finite element analysis and composite laminate theory to perform design optimization using both shape and material design variables. The external and internal geometry of the implant and the surrounding bone is described with quintic spline curves. This geometric representation is then used to create an equivalent 2-D finite element model of the structure. Using laminate theory and the 3-D geometric information, equivalent stiffnesses are generated for each element of the 2-D finite element model, so that the 3-D stiffness of the structure can be approximated. The geometric information to construct the model of the femur was obtained from a CT scan. A variety of test cases were examined, incorporating several implant constructions and design variable sets. Typically the code was able to produce optimized shape and/or material parameters which substantially reduced stress concentrations in the bone adjacent of the implant. The results indicate that this technology can provide meaningful insight into the design of fiber composite hip implants.

Blake, T. A.↗

Challenges in Integrating Nondestructive Evaluation and Finite Element Methods for Realistic Structural Analysis

Capabilities and expertise related to the development of links between nondestructive evaluation (NDE) and finite element analysis (FEA) at Glenn Research Center (GRC) are demonstrated. Current tools to analyze data produced by computed tomography (CT) scans are exercised to help assess the damage state in high temperature structural composite materials. A utility translator was written to convert velocity (an image processing software) STL data file to a suitable CAD-FEA type file. Finite element analyses are carried out with MARC, a commercial nonlinear finite element code, and the analytical results are discussed. Modeling was established by building MSC/Patran (a pre and post processing finite element package) generated model and comparing it to a model generated by Velocity in conjunction with MSC/Patran Graphics. Modeling issues and results are discussed in this paper. The entire process that outlines the tie between the data extracted via NDE and the finite element modeling and analysis is fully described.

Abdul-Aziz, Ali↗

Body Imaging

Magnetic Resonance Imaging (MRI) and Computer-aided Tomography (CT) images are often complementary. In most cases, MRI is good for viewing soft tissue but not bone, while CT images are good for bone but not always good for soft tissue discrimination. Physicians and engineers in the Department of Radiology at the University of Michigan Hospitals are developing a technique for combining the best features of MRI and CT scans to increase the accuracy of discriminating one type of body tissue from another. One of their research tools is a computer program called HICAP. The program can be used to distinguish between healthy and diseased tissue in body images.

Source record↗

Proton and Electron Threshold Energy Measurements for Extravehicular Activity Space Suits

Construction of ISS will require more than 1000 hours of EVA. Outside of ISS during EVA, astronauts and cosmonauts are likely to be exposed to a large fluence of electrons and protons. Development of radiation protection guidelines requires the determination of the minimum energy of electrons and protons that penetrate the suits at various locations. Measurements of the water-equivalent thickness of both US. and Russian EVA suits were obtained by performing CT scans. Specific regions of interest of the suits were further evaluated using a differential range shift technique. This technique involved measuring thickness ionization curves for 6-MeV electron and 155-MeV proton beams with ionization chambers using a constant source-to-detector distance. The thicknesses were obtained by stacking polystyrene slabs immediately upstream of the detector. The thicknesses of the 50% ionizations relative to the maximum ionizations were determined. The detectors were then placed within the suit and the stack thickness adjusted until the 50% ionization was reestablished. The difference in thickness between the 50% thicknesses was then used with standard range-energy tables to determine the threshold energy for penetration. This report provides a detailed description of the experimental arrangement and results.

Moyers, M. F.↗

Effect of optical digitizer selection on the application accuracy of a surgical localization system-a quantitative comparison between the OPTOTRAK and flashpoint tracking systems

Application accuracy is a crucial factor for stereotactic surgical localization systems, in which space digitization camera systems are one of the most critical components. In this study we compared the effect of the OPTOTRAK 3020 space digitization system and the FlashPoint Model 3000 and 5000 3D digitizer systems on the application accuracy for interactive localization of intracranial lesions. A phantom was mounted with several implantable frameless markers which were randomly distributed on its surface. The target point was digitized and the coordinates were recorded and compared with reference points. The differences from the reference points represented the deviation from the "true point." The root mean square (RMS) was calculated to show the differences, and a paired t-test was used to analyze the results. The results with the phantom showed that, for 1-mm sections of CT scans, the RMS was 0.76 +/- 0. 54 mm for the OPTOTRAK system, 1.23 +/- 0.53 mm for the FlashPoint Model 3000 3D digitizer system, and 1.00 +/- 0.42 mm for the FlashPoint Model 5000 system. These preliminary results showed that there is no significant difference between the three tracking systems, and, from the quality point of view, they can all be used for image-guided surgery procedures. Copyright 1999 Wiley-Liss, Inc.

Non-NASA Center↗

Composite Flywheels Assessed Analytically by NDE and FEA

As an alternative to expensive and short-lived lead-acid batteries, composite flywheels are being developed to provide an uninterruptible power supply for advanced aerospace and industrial applications. Flywheels can help prevent irregularities in voltage caused by power spikes, sags, surges, burnout, and blackouts. Other applications include load-leveling systems for wind and solar power facilities, where energy output fluctuates with weather. Advanced composite materials are being considered for these components because they are significantly lighter than typical metallic alloys and have high specific strength and stiffness. However, much more research is needed before these materials can be fully utilized, because there is insufficient data concerning their fatigue characteristics and nonlinear behavior, especially at elevated temperatures. Moreover, these advanced types of structural composites pose greater challenges for nondestructive evaluation (NDE) techniques than are encountered with typical monolithic engineering metals. This is particularly true for ceramic polymer and metal matrix composites, where structural properties are tailored during the processing stages. Current efforts involving the NDE group at the NASA Glenn Research Center at Lewis Field are focused on evaluating many important structural components, including the flywheel system. Glenn's in-house analytical and experimental capabilities are being applied to analyze data produced by computed tomography (CT) scans to help assess the damage and defects of high-temperature structural composite materials. Finite element analysis (FEA) has been used extensively to model the effects of static and dynamic loading on aerospace propulsion components. This technique allows the use of complicated loading schemes by breaking the complex part geometry into many smaller, geometrically simple elements.

Abdul-Aziz, Ali↗

Low-Cost, Large C-SiC Blisk Fabrication

C-SiC composites offer unique properties for propulsion applications. However, fabrication of low-cost, thick, large scale C-SiC disk for integrally bladed disk (blisk) applications has not been established yet. MER has demonstrated a new process to address this issue. Polymer-based processing was employed for interfacial coatings, consolidation and densification. Up to 40" O.C., 2" thick C-SiC composite processing was established, yielding in excess of 1.8 g/cu cm density. Computer tomography (CT) scans on the 40" O.D., 2" thick C-SiC disk showed no visible delamination, and good density uniformity. Stress-rupture testing in air was conducted at 2200 F, 2400 F and 2550 F.

Kowbel, W.↗