IDC Re-Engineering Phase 2 System Specification Document Version 1.5

This document contains the system specifications derived to satisfy the system requirements found in the IDC System Requirements Document for the IDC Re-Engineering Phase 2 project. This System Specification Document (SSD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data but does include requirements for the dissemination of radionuclide data and products.

97 MATHEMATICS AND COMPUTING↗

IDC Re-Engineering Phase 2 System Requirements Document Version 1.4

This System Requirements Document (SRD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The IDC applies, on a routine basis, automatic processing methods and interactive analysis to raw International Monitoring System (IMS) data in order to produce, archive, and distribute standard IDC products on behalf of all States Parties. The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data, but includes requirements for the dissemination of radionuclide data and products.

97 MATHEMATICS AND COMPUTING↗

Proceedings of the 2011 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

These proceedings contain papers prepared for the Monitoring Research Review 2011: Ground-Based Nuclear Explosion Monitoring Technologies, held 13-15 September, 2011 in Tucson, Arizona. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Defense Threat Reduction Agency (DTRA), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), National Science Foundation (NSF), and other invited sponsors. The scientific objectives of the research are to improve the United States' capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

135 Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring

Measurement of elevated concentrations of xenon radioisotopes ( 131m Xe, 133m Xe, 133 Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for verifying whether or not a detected explosion is nuclear in nature. These isotopes are among the few with enough mobility and with half-lives long enough to make their detection at long distances realistic. Existing radioxenon detection systems used by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) suffer from problems such as complexity, need for high maintenance and memory effect. To study the response of CdZnTe (CZT) detectors to xenon radioisotopes and investigate whether it is capable of mitigating the afore-mentioned issues with the current radioxenon detection systems, a prototype detector utilizing two coplanar CZT detectors was built and tested at Oregon State University. The detection system measures xenon radioisotopes through beta-gamma coincidence technique by detecting coincidence events be-tween the two detectors. Here in this paper, we introduce the detector design and report our measurement results with radioactive lab sources and 135 Xe produced in the OSU TRIGA reactor. Minimum Detectable Concentration (MDC) for 135 Xe was calculated to be 1.47 ± 0.05 mBq/m 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examining the potential for detecting simultaneous noble gas and aerosol samples in the international monitoring system radionuclide network

The purpose of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) is to establish a legally binding ban on nuclear weapon test explosions or any other nuclear explosions. The Preparatory Commission for the CTBT Organization (CTBTO PrepCom) is developing the International Monitoring System (IMS) that includes a global network of 80 stations to monitor for airborne radionuclides upon entry into force of the CTBT. All 80 radionuclide stations will monitor for particulate radionuclides and at least half of the stations will monitor for radioxenon. The airborne radionuclide monitoring is an important verification technology both for the detection of a radionuclide release and in the determination of whether the release event originates from a nuclear explosion as opposed to an industrial use of nuclear materials. Nuclear power plants and many medical isotope production facilities release radioxenon into the atmosphere. Low levels of a few particulate isotopes, such as iodine, may also be released. Detections of multiple isotopes are useful for screening the radionuclide samples for relevance to the Treaty. This paper examines the anticipated joint detections in the IMS of noble gas and particulate isotopes from underground nuclear explosions where breaches in the underground containment vents from low levels to up to 1% of the radionuclide inventory of the resulting fission products to the atmosphere. Detection probabilities are based on 844 simulated release events spaced out at 17 release locations and one year in time. Six different release (venting) scenarios, including two fractionated scenarios, were analyzed. When ranked by detection probability, 11 particulate isotopes and one noble gas isotope ( 133 Xe) appear in the top 20 isotopes for all six release scenarios. Using the 11 particulate isotopes and the one noble gas isotope, the IMS has nearly the same detection probability as when 45 particulate and 4 noble gas isotopes are used. Thus, a limited list of relevant radionuclides may be sufficient for treaty verification purposes. The probability that at least one particulate and at least one radioxenon isotope would be detected in the IMS from the release events ranged from 0.15 to 0.86 depending on the release scenario.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A prototype detection system for atmospheric monitoring of xenon radioisotopes

The design of a radioxenon detection system utilizing a CdZeTe crystal and a plastic scintillator coupled to an array of SiPMs to conduct beta-gamma coincidence detection for atmospheric radioxenon monitoring, as well as the measurement of 135 Xe and 133/133m Xe, have been detailed previously. This paper presents recent measurements of 133/133m Xe and 131m Xe and the observation of conversion electrons in their coincidence spectra, as well as a 48-hour background measurement to calculate the Minimum Detectable Concentration (MDC) of radioxenon isotopes in the system. The identification of Regions of Interest (ROIs) in the coincidence spectra yielded from the radioxenon measurements, and the subsequent calculation of the MDCs of the system for 135 Xe, 133/133m Xe, and 131m Xe, are also discussed. Calculated MDCs show that the detection system preforms respectably when compared to other state of the art radioxenon detection systems and achieved an MDC of less than 1 mBq/m 3 for 131m Xe, 133 Xe, and 133m Xe, in accordance with limits set by the Comprehensive Nuclear-Test-Ban Treaty (CTBTO). Lastly, the system also provides the advantage of room temperature operation, compactness, low noise operation and having simple readout electronics.

36 MATERIALS SCIENCE↗

Applying Waveform Correlation to Reduce Seismic Analyst Workload Due to Repeating Mining Blasts

Agencies that monitor for underground nuclear tests are interested in techniques that automatically characterize mining blasts to reduce the human analyst effort required to produce high–quality event bulletins. Waveform correlation is effective in finding similar waveforms from repeating seismic events, including mining blasts. We report the results of an experiment to detect and identify mining blasts for two regions, Wyoming (U.S.A.) and Scandinavia, using waveform templates recorded by multiple International Monitoring System stations of the Preparatory Commission for the Comprehensive Nuclear–Test–Ban Treaty Organization (CTBTO PrepCom) for up to 10 yr prior to the time of interest. We discuss approaches for template selection, threshold setting, and event detection that are specialized for characterizing mining blasts using a sparse, global network. We apply the approaches to one week of data for each of the two regions to evaluate the potential for establishing a set of standards for waveform correlation processing of mining blasts that can be generally applied to operational monitoring systems with a sparse network. Here, we compare candidate events detected with our processing methods to the Reviewed Event Bulletin of the International Data Centre to assess potential reduction in analyst workload.

58 GEOSCIENCES↗

Preface to the Focus Section on North Korea’s September 2017 Nuclear Test and Its Aftermath

On September 3, 2017 a large seismic event was detected near the Punggye-ri nuclear test site in North Korea (officially known as the Democratic People Republic of Korea or DPRK) by several geophysical monitoring institutions (for example, the USGS announced it as mb 6.3 event, the CTBTO announced it as a mb 6.1 event). Within a few hours North Korea declared it had carried out its sixth underground nuclear explosion, a test of a hydrogen bomb.

58 GEOSCIENCES↗

A General Investigation of Optimized Atmospheric Sample Duration

ABSTRACT The International Monitoring System (IMS) consists of up to 80 aerosol and xenon monitoring systems spaced around the world that have collection systems sensitive enough to detect nuclear releases from underground nuclear tests at great distances (CTBT 1996; CTBTO 2011). Although a few of the IMS radionuclide stations are closer together than 1,000 km (such as the stations in Kuwait and Iran), many of them are 2,000 km or more apart. In the absence of a scientific basis for optimizing the duration of atmospheric sampling, historically scientists used a integration times from 24 hours to 14 days for radionuclides (Thomas et al. 1977). This was entirely adequate in the past because the sources of signals were far away and large, meaning that they were smeared over many days by the time they had travelled 10,000 km. The Fukushima event pointed out the unacceptable delay time (72 hours) between the start of sample acquisition and final data being shipped. A scientific basis for selecting a sample duration time is needed. This report considers plume migration of a nondecaying tracer using archived atmospheric data for 2011 in the HYSPLIT (Draxler and Hess 1998; HYSPLIT 2011) transport model. We present two related results: the temporal duration of the majority of the plume as a function of distance and the behavior of the maximum plume concentration as a function of sample collection duration and distance. The modeled plume behavior can then be combined with external information about sampler design to optimize sample durations in a sampling network.

CTBT↗

NetMOD version 1.0 user's manual

NetMOD (Network Monitoring for Optimal Detection) is a Java-based software package for conducting simulation of seismic networks. Specifically, NetMOD simulates the detection capabilities of seismic monitoring networks. Network simulations have long been used to study network resilience to station outages and to determine where additional stations are needed to reduce monitoring thresholds. NetMOD makes use of geophysical models to determine the source characteristics, signal attenuation along the path between the source and station, and the performance and noise properties of the station. These geophysical models are combined to simulate the relative amplitudes of signal and noise that are observed at each of the stations. From these signal-to-noise ratios (SNR), the probability of detection can be computed given a detection threshold. This manual describes how to configure and operate NetMOD to perform seismic detection simulations. In addition, NetMOD is distributed with a simulation dataset for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) International Monitoring System (IMS) seismic network for the purpose of demonstrating NetMOD's capabilities and providing user training. The tutorial sections of this manual use this dataset when describing how to perform the steps involved when running a simulation.

58 GEOSCIENCES↗

MB3a Infrasound Sensor Evaluation.

Sandia National Laboratories has tested and evaluated a new infrasound sensor, the MB3a, manufactured by Seismo Wave. These infrasound sensors measure pressure output by a methodology developed by researchers at the French Alternative Energies and Atomic Energy Commission (CEA) and the technology was recently licensed to Seismo Wave for production and sales. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, dynamic range, seismic sensitivity, and self- calibration ability. The MB3a infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

Merchant, Bion J.↗

IDC Reengineering Phase 2 Project Scope

The Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) operates the International Data Centre (IDC) to support treaty verification activities by Member States. The IDC collects, stores, processes, and distributes data from seismic, hydroacoustic, infrasound, and radionuclide stations. A significant component of the IDC is the seismic, hydroacoustic, and infrasound (SHI) processing system. The IDC has recognized the need to reengineer the SHI processing system and has defined a three-phase reengineering effort. IDC Reengineering Phase 1 (RP1) started in 2011 with the goal to significantly modernize SHI automatic and interactive data processing software, focusing on enhancements to individual components of the system. Reengineering Phase 2 (RP2), started in 2014, addresses the task of specifying a unified architecture for all SHI software, across processing stages, to pave the way for further software development and sustainment in the future. A key objective of RP2 is an architecture sufficient to provide a basis for a cost estimate for the development or enhancement of the software components and subsystems. This report provides a brief description of the scope of the IDC Reengineering Phase 2 project. It describes the goals and objectives of reengineering, the system definition, and the technical scope of the system.This report expands upon the “Scope for IDC Reengineering Phase 2”, July 2014, ECS-DIS-WGB-43-PTS-MATERIAL-12-ADD-1, produced by the IDC.

58 GEOSCIENCES↗

Evaluation of Two Guralp Preamplifiers for GS21 Seismometer Application

Sandia National Laboratories has tested and evaluated two Guralp preamplifiers for use with a GS21 seismometer application. The two preamplifiers have a gain factor of 61.39. The purpose of the preamplifier evaluation was to determine a measured gain factor, transfer function, total harmonic distortion, self-noise, application passband, dynamic range, seismometer calibration pass-through, and to comment on any issues encountered during the evaluation. The test results included in this report were in response to static, tonal, and dynamic input signals. The Guralp GS21 preamplifiers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO). Test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Hyperion 5113/A Infrasound Sensor Evaluation

Sandia National Laboratories has tested and evaluated an infrasound sensor, the 5113/A manufactured by Hyperion. These infrasound sensors measure pressure output by a methodology developed by the University of Mississippi. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, and dynamic range. The 5113/A infrasound sensor is a new revision of the 5000 series intended to meet the infrasound application requirements for use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

IDC Re-Engineering Phase 2 System Requirements Document V1.3.

This System Requirements Document (SRD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The IDC applies, on a routine basis, automatic processing methods and interactive analysis to raw International Monitoring System (IMS) data in order to produce, archive, and distribute standard IDC products on behalf of all States Parties. The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data but includes requirements for the dissemination of radionuclide data and products.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

CEA SMAD 2016 Digitizer Evaluation.

Sandia National Laboratories has tested and evaluated an updated SMAD digitizer, developed by the French Alternative Energies and Atomic Energy Commission (CEA). The SMAD digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The SMAD digitizers have been updated since their last evaluation by Sandia to improve their performance when recording at a sample rate of 20 Hz for infrasound applications and 100 Hz for hydro-acoustic seismic stations. This evaluation focuses primarily on the 20 Hz and 100 Hz sample rates. The SMAD digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test- Ban-Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Two Guralp Preamplifiers for GS13 Seismometer Application.

Sandia National Laboratories has tested and evaluated a new preamplifier, the Guralp Preamplifier for GS13, manufactured by Guralp. These preamplifiers are used to interface between Guralp digitizers and Geotech GS13 Seismometers. The purpose of the preamplifier evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Guralp GS13 Preamplifiers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗