Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminated data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Diagnosis of a two wire X-pinch by X-ray absorption spectroscopy utilizing a doubly curved ellipsoidal crystal

X-ray absorption spectroscopy is a powerful tool for the diagnosis of plasmas over a wide range of both temperature and density. However, such a measurement is often limited to probing plasmas with temperatures well below that of the x-ray source in order to avoid object plasma emission lines from obscuring important features of the absorption spectrum. This has excluded many plasmas from being investigated by this technique. We have developed an x-ray spectrometer that provides the ability to record absorption spectra from higher temperature plasmas than the usual approach allows without the risk of data contamination by line radiation emitted by the plasma under study. This is accomplished using a doubly curved mica crystal which is bent both elliptically and cylindrically. We present here initial absorption spectra obtained from an aluminum x-pinch plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fusing geophysical signatures of locally recorded surface explosions to improve blast detection

We recorded acoustic, seismic and radio-frequency signatures of 70 solid charge (~2–12 kg) surface explosions (shots) at local distances (0.1–1.5 km) to determine if such signals could be fused for blast monitoring. We observed that each geophysical signature was sufficiently repeatable between similar shots to be identifiable with multichannel correlation detectors. Using template signals from a large explosion, we then processed heavily contaminated data recording a smaller shot with these detectors, and missed or marginally detected the resultant target signals. By then fusing the p-values of these statistics through Fisher's combined probability test, we clearly identified the same explosion signals at thresholds consistent with the false alarm on noise rates of the correlation detectors. This resulting Fisher test thereby provided high-probability detections, zero false alarms and higher theoretical detection capability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optimization-based scatter estimation using primary modulation for computed tomography

Purpose: Scatter reduces the image quality in computed tomography (CT), but scatter correction remains a challenge. A previously proposed primary modulation method simultaneously obtains the primary and scatter in a single scan. However, separating the scatter and primary in primary modulation is challenging because it is an underdetermined problem. In this study, an optimization-based scatter estimation (OSE) algorithm is proposed to estimate and correct scatter. Methods: In the concept of primary modulation, the primary is modulated, but the scatter remains smooth by inserting a modulator between the x-ray source and the object. In the proposed algorithm, an objective function is designed for separating the scatter and primary. Prior knowledge is incorporated in the optimization-based framework to improve the accuracy of the estimation: (1) the primary is always positive; (2) the primary is locally smooth and the scatter is smooth; (3) the location of penumbra can be determined; and (4) the scatter-contaminated data provide knowledge about which part is smooth. Results: The simulation study shows that the edge-preserving weighting in OSE improves the estimation accuracy near the object boundary. Simulation study also demonstrates that OSE outperforms the two existing primary modulation algorithms for most regions of interest in terms of the CT number accuracy and noise. The proposed method was tested on a clinical cone beam CT, demonstrating that OSE corrects the scatter even when the modulator is not accurately registered. Conclusions: The proposed OSE algorithm improves the robustness and accuracy in scatter estimation and correction. This method is promising for scatter correction of various kinds of x-ray imaging modalities, such as x-ray radiography, cone beam CT, and the fourth-generation CT.

60 APPLIED LIFE SCIENCES↗

A Dynamic Landsat Derived Normalized Difference Vegetation Index (NDVI) Product for the Conterminous United States

Satellite derived vegetation indices (VIs) are broadly used in ecological research, ecosystem modeling, and land surface monitoring. The Normalized Difference Vegetation Index (NDVI), perhaps the most utilized VI, has countless applications across ecology, forestry, agriculture, wildlife, biodiversity, and other disciplines. Calculating satellite derived NDVI is not always straight-forward, however, as satellite remote sensing datasets are inherently noisy due to cloud and atmospheric contamination, data processing failures, and instrument malfunction. Readily available NDVI products that account for these complexities are generally at coarse resolution; high resolution NDVI datasets are not conveniently accessible and developing them often presents numerous technical and methodological challenges. Here, we address this deficiency by producing a Landsat derived, high resolution (30 m), long-term (30+ years) NDVI dataset for the conterminous United States. We use Google Earth Engine, a planetary-scale cloud-based geospatial analysis platform, for processing the Landsat data and distributing the final dataset. We use a climatology driven approach to fill missing data and validate the dataset with established remote sensing products at multiple scales. We provide access to the composites through a simple web application, allowing users to customize key parameters appropriate for their application, question, and region of interest.

42 ENGINEERING↗

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical Laboratory (AL) at the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RH-TRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization if RH-TRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all AK [define AK] documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Tritium safety study using Caisson Assembly (CATS) at TPL/JAEA

Tritium confinement is required as the most important safety Junction for a fusion reactor. In order to demonstrate the confinement performance experimentally, an unique equipment, called CATS: Caisson Assembly for Tritium Safety study, was installed in Tritium Process Laboratory of Japan Atomic Energy Agency and operated for about 10 years. Tritium confinement and migration data in CATS have been accumulated and dynamic simulation code was accumulated using these data. Contamination and decontamination behavior on various materials and new safety equipment functions have been investigated under collaborations with a lot of laboratories and universities. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deriving Stable Peak Models to Fit Complex XPS Data From Cu Contaminated Pt Electrocatalysts

X-ray Photoelectron Spectroscopy spectra peak models, designed to partition photoemission signals emanating from different elements or chemical states within an atom, are fitted to data limited to an energy interval over which inelastically scattered photoemission signal can be estimated. While the choice of background approximation and line shapes of components to the peak model requires careful consideration, the energy interval used to define the data to which the peak model is optimized has a significant impact on the final peak model. The relationship between the background intensity and data intensity at the start and end of the energy interval dictates the line shapes used in the peak model. In this work, we devise a method to peak fit a complex overlapping Cu 3p and Pt 4f XPS peak structure to perform the elemental quantification. We first use an Al 2s peak to illustrate how background curves approach data at the limits of the energy interval over which the background is defined, influencing the analysis of XPS spectra. Next, we demonstrate the nature of interactions between specific line shapes (Voigt and pseudo-Voigt profiles) suitable for photoemission peaks and a specific background curve (Shirley) and a peak model is presented that includes components to the peak model that accommodates background intensity during fitting of the peak model to data. The peak model allowed for quantification of the contributions of Pt 4f peaks emanating from the substrate that exhibits strong asymmetry in the presence of the inhomogeneously distributed Cu species, mostly of Lorentzian character.

XPS↗

A data variance technique for automated despiking of magnetotelluric data with a remote reference

The magnetotelluric method employs co-located surface measurements of electric and magnetic fields to infer the local electrical structure of the earth. The frequency-dependent 'apparent resistivity' curves can be inaccurate at long periods if input data are contaminated - even when robust remote reference techniques are employed. Data despiking prior to processing can result in significantly more reliable estimates of long period apparent resistivities. This paper outlines a two-step method of automatic identification and replacement for spike-like contamination of magnetotelluric data; based on the simultaneity of natural electric and magnetic field variations at distant sites. This simultaneity is exploited both to identify windows in time when the array data are compromised, and to generate synthetic data that replace observed transient noise spikes. In the first step, windows in data time series containing spikes are identified via intersite comparison of channel 'activity' - such as the variance of differenced data within each window. In the second step, plausible data for replacement of flagged windows is calculated by Wiener filtering coincident data in clean channels. The Wiener filters - which express the time-domain relationship between various array channels - are computed using an uncontaminated segment of array training data. Examples are shown where the algorithm is applied to artificially contaminated data, and to real field data. In both cases all spikes are successfully identified. In the case of implanted artificial noise, the synthetic replacement time series are very similar to the original recording. In all cases, apparent resistivity and phase curves obtained by processing the despiked data are much improved over curves obtained from raw data.

54 ENVIRONMENTAL SCIENCES↗

Residual foreground contamination in the WMAP data and bias in non-Gaussianity estimation

We analyze whether there is any residual foreground contamination in the cleaned WMAP 7 years data for the differential assemblies, Q, V and W. We calculate the correlation between the foreground map, from which long wavelength correlations have been subtracted, and the foreground reduced map for each differential assembly after applying the Galaxy and point sources masks. We find positive correlations for all the differential assemblies, with high statistical significance. For Q and V, we find that a large fraction of the contamination comes from pixels where the foreground maps have positive values larger than three times the rms values. These findings imply the presence of residual contamination from Galactic emissions and unresolved point sources. We redo the analysis after masking the extended point sources cataloque of Scodeller et al. [7] and find a drop in the correlation and corresponding significance values. To quantify the effect of the residual contamination on the search for primordial non-Gaussianity in the CMB we add estimated contaminant fraction to simulated Gaussian CMB maps and calculate the characteristic non-Gaussian deviation shapes of Minkowski Functionals that arise due to the contamination. We find remarkable agreement of these deviation shapes with those measured from WMAP data, which imply that a major fraction of the observed non-Gaussian deviation comes from residual foreground contamination. We also compute non-Gaussian deviations of Minkowski Functionals after applying the point sources mask of Scodeller et al. and find a decrease in the overall amplitudes of the deviations which is consistent with a decrease in the level of contamination.

79 ASTRONOMY AND ASTROPHYSICS↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-10: One-Step CT Reconstruction for Metal Artifact Reduction by a Modification of Penalized Weighted Least-Squares (PWLS)

Purpose: Metal objects create severe artifacts in kilo-voltage (kV) CT image reconstructions due to the high attenuation coefficients of high atomic number objects. Most of the techniques devised to reduce this artifact utilize a two-step approach, which do not reliably yield the qualified reconstructed images. Thus, for accuracy and simplicity, this work presents a one-step reconstruction method based on a modified penalized weighted least-squares (PWLS) technique. Methods: Existing techniques for metal artifact reduction mostly adopt a two-step approach, which conduct additional reconstruction with the modified projection data from the initial reconstruction. This procedure does not consistently perform well due to the uncertainties in manipulating the metal-contaminated projection data by thresholding and linear interpolation. This study proposes a one-step reconstruction process using a new PWLS operation with total-variation (TV) minimization, while not manipulating the projection. The PWLS for CT reconstruction has been investigated using a pre-defined weight, based on the variance of the projection datum at each detector bin. It works well when reconstructing CT images from metal-free projection data, which does not appropriately penalize metal-contaminated projection data. The proposed work defines the weight at each projection element under the assumption of a Poisson random variable. This small modification using element-wise penalization has a large impact in reducing metal artifacts. For evaluation, the proposed technique was assessed with two noisy, metal-contaminated digital phantoms, against the existing PWLS with TV minimization and the two-step approach. Result: The proposed PWLS with TV minimization greatly improved the metal artifact reduction, relative to the other techniques, by watching the results. Numerically, the new approach lowered the normalized root-mean-square error about 30 and 60% for the two cases, respectively, compared to the two-step method. Conclusion: A new PWLS operation shows promise for improving metal artifact reduction in CT imaging, as well as simplifying the reconstructing procedure.

60 APPLIED LIFE SCIENCES↗

KBase Narrative - Supplemental Data for "Mixed waste contamination selects for a mobile genetic element population enriched in multiple heavy metal resistance genes"

Here we provide the complete set of circular elements produced by SCAPP from metagenomic data that may represent mobile genetic elements (MGEs). For the publication, these sequences were de-replicated within the high [U] and low [U] sample sets. Additionally, 98 of the circular elements were removed for downstream analysis due to high suspicion of being (1) chloroplast or mitochondrial sequences or (2) erroneously circularized long repeat regions. The complete list of circular elements used for the analysis along with metadata can be found in Tables S5 and S6.

Goff, Jennifer↗

λ/2 contamination in X-ray diffraction data – the impact of heavy atoms

The impact of very different values of f ' and f " and of absorption coefficients for the wavelengths λ and λ/2 for heavy elements, and the effect of the difference in wavelength dispersion on the profile of the corresponding Bragg reflections, are discussed with respect to the correction of diffraction data for λ/2 contamination. The impact on the results of four charge-density studies is discussed.

Chemistry↗

Fermilab PIP-II machine protection system digitized data noise elimination scheme and its FPGA implementation

In Fermilab's PIP-II machine protection system, beam loss signals from various detectors are digitized at 125 MS/s. Noise from both high-frequency sources and low-frequency 60 Hz AC power equipment can contaminate the data. To suppress noise across these ranges—especially 60 Hz and its harmonics, which overlap with beam loss signal frequencies—advanced digital processing beyond standard filtering is required. Several real-time functional blocks were simulated and tested on an FPGA: (1) a dual time-constant discharging integrator filter, (2) a de-ripple baseline extraction and storage block, and (3) a fast-recovery discharging integrator. The nonlinear IIR integrator filter removes high-frequency noise and feeds into the baseline extractor. Upon detecting abrupt beam loss, it switches to a longer time constant to prevent baseline distortion. The de-ripple block calculates a valid baseline by averaging over multiple 60 Hz periods, storing results in a 4096-word FPGA RAM. This baseline is subtracted from raw data before integration by the fast-recovery block, which resets quickly after use. All blocks achieved expected performance and were successfully implemented on a low-cost FPGA.

Wu, Jinyuan [Fermilab]↗

Impact of air exposure and surface chemistry on Li-Li 7 La 3 Zr 2 O 12 interfacial resistance

Li 7 La 3 Zr 2 O 12 (LLZO) is a promising solid-state electrolyte that could enable solid-state-batteries (SSB) employing metallic Li anodes. For a SSB to be viable, the stability and charge transfer kinetics at the Li–LLZO interface should foster facile plating and stripping of Li. Contrary to these goals, recent studies have reported high Li–LLZO interfacial resistance which was attributed to a contamination layer that forms upon exposure of LLZO to air. This study clarifies the mechanisms and consequences associated with air exposure of LLZO; additionally, strategies to minimize these effects are described. First-principles calculations reveal that LLZO readily reacts with humid air; the most favorable reaction pathway involves protonation of LLZO and formation of Li2CO3. X-ray photoelectron spectroscopy, scanning electron microscopy, Raman spectroscopy, and transmission electron microscopy were used to characterize the surface and subsurface chemistry of LLZO as a function of relative humidity and exposure time. Additionally, electrochemical impedance spectroscopy was used to measure the Li–LLZO interfacial resistance as a function of surface contamination. These data indicate that air exposure-induced contamination impacts the interfacial resistance significantly, when exposure time exceeds 24 h. The results of this study provide valuable insight into the sensitivity of LLZO to air and how the effects of air contamination can be reversed.

36 MATERIALS SCIENCE↗

Characterizing manufacturing wastewater in the United States for the purpose of analyzing energy requirements for reuse

This paper seeks to inform an improved understanding of the energy tradeoff associated with on-site manufacturing water reuse in the United States from a lifecycle perspective, in part by developing an analytical framework for understanding when this tradeoff for reuse is beneficial. We survey the literature to assess the current state of reuse and its motives and barriers in the United States, before synthesizing information from publicly available EPA data on contaminants in US manufacturing wastewaters and technologies for treating them. Using the available data, we derive a set of “ubiquitous contaminants” among the top ten in terms of mass discharged in more than half of US manufacturing subsectors (NAICS 31–33) according to EPA permit data. We also present information on proven treatment trains and their energy requirements. We then compare water quality requirements for specific contaminants in reclaimed water to those characteristic of wastewater streams currently being discharged from manufacturing plants into surface waters to highlight sectors with reuse opportunities that could require little cost to realize, such as primary metals and, to a lesser extent, petroleum and coal products. We conclude by highlighting data limitations that need to be rectified before applying the framework more broadly and discussing how these data gaps could be filled. Better understanding the relationship between energy and water in the context of on-site manufacturing water reuse would allow manufacturers to improve resiliency by reducing regulatory, physical, and reputational risks while lessening their footprint on local watersheds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗