Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Vortex generating flow passage design for increased film-cooling effectiveness and surface coverage

The fluid mechanics of the basic discrete hole film cooling process is described as an inclined jet in crossflow and a cusp shaped coolant flow channel contour that increases the efficiency of the film cooling process is hypothesized. The design concept requires the channel to generate a counter rotating vortex pair secondary flow within the jet stream by virture of flow passage geometry. The interaction of the vortex structures generated by both geometry and crossflow was examined in terms of film cooling effectiveness and surface coverage. Comparative data obtained with this vortex generating coolant passage showed up to factors of four increases in both effectiveness and surface coverage over that obtained with a standard round cross section flow passage. A streakline flow visualization technique was used to support the concept of the counter rotating vortex pair generating capability of the flow passage design.

Papell, S. S.↗

Film cooling effectiveness and heat transfer with injection through holes

An experimental investigation of the local film cooling effectiveness and heat transfer downstream of injection of air through discrete holes into a turbulent boundary layer of air on a flat plate is reported. Secondary air is injected through a single hole normal to the main flow and through both a single hole and a row of holes spaced at three diameter intervals with an injection angle of 35 deg to the main flow. Two values of the mainstream Reynolds number are used; the blowing rate is varied from 0.1 to 2.0. Photographs of a carbon dioxide-water fog injected into the main flow at an angle of 90 deg are also presented to show interaction between the jet and mainstream.

Eriksen, V. L.↗

Vortex generating flow passage design for increased film cooling effectiveness

It is an object of the invention to provide a film cooling apparatus of increased effectiveness and efficiency. In accordance with the invention, a cooling fluid is injected into a hot flowing gas through a passageway in a wall which contains and is subject to the hot gas. The passageway is slanted in a downstream direction at an acute angle to the wall. A cusp shape is provided in the passageway to generate vortices in the injected cooling fluid thereby reducing the energy extracted from the hot gas for that purpose. The cusp shape increases both film cooling effectiveness and wall area coverage. The cusp may be at either the downstream or upstream side of the passageway, the former substantially eliminating flow separation of the cooling fluid from the wall immediately downstream of the passageway.

Papell, S. S.↗

Film Cooling Effectiveness Measurements on a CMC-Simulated Flat Plate

Ceramic matrix composites (CMC) are high temperature materials that can allow higher operating turbomachinery engine temperatures with less coolant required. One method of fabricating ceramic matrix composites is by weaving fibers into the shape of an airfoil. Generally, CMC fiber tows are assembled with various weave patterns, but this uneven surface could introduce aerodynamic losses, and it will be necessary to determine the best film cooling hole arrangement for minimal thermal engine efficiency loss. As part of an effort to assess the impact of geometric constraints of CMC implementation relative to metallic high pressure turbine blades, an experimental study was performed to investigate the effect of film cooling on a CMC-like surface roughened flat plate. Film cooling effectiveness measurements were acquired on a large-scale surface with a ceramic matrix composite weave pattern and on a smooth surface for comparison. A single row and a 2-row cooling hole arrangement were investigated with different hole sizes. Infrared thermography data was acquired at several Reynolds numbers and blowing ratios. Results showed that the effect on span averaged film cooling effectiveness was small between a weave surface pattern and a smooth surface, while hole spacing dependence had a much stronger effect.

infrared↗

Swept-slot film-cooling effectiveness in hypersonic turbulent flow

Measurement results are presented for the surface equilibrium temperature downstream of swept slots, with sonic tangential air injection into a thick hypersonic turbulent boundary layer. These results are compared with unswept slot results for cooling effectiveness.

Hefner, J. N.↗

Concurrent Cooling Effects of Dynamic Line Ratings on Wind Plant Gen-Tie Lines

This report was prepared for the Wind Energy Technology Office for the FY 2022, quarter 2 deliverable. This details the use of dynamic line rating technology to rate a series of gen tie lines connecting wind plants to the regional transmission lines. This consists of two primary study regions, the first on the desert west of Idaho Falls, and the second in the region east of the Cascades along the Columbia River Gorge. The TREAD program that was developed at INL was used to create generated gen-tie lines based on nearby regional transmission line connections. The capacity availability of the gen tie lines are compared with the power production of the wind farms. Overall, the INL Site location shows a much greater capacity for the gen-tie lines due to the higher wind speeds. Across both locations, the HRRR data shows higher wind speeds than observed at the observational weather stations. For both the Columbia Gorge and Idaho areas, the sites show that a statically rate gen-tie could carry additional capacity far above the rated during periods of high wind due to the concurrent cooling effects.

17 WIND ENERGY↗

Influence of coolant tube curvature on film cooling effectiveness as detected by infrared imagery

Thermal film cooling footprints observed by infrared imagery from straight, curved, and looped coolant tube geometries are compared. It was hypothesized that the differences in secondary flow and in the turbulence structure of flow through these three tubes should influence the mixing properties between the coolant and the main stream. A flow visualization tunnel, an infrared camera and detector, and a Hilsch tube were employed to test the hypothesis.

Papell, S. S.↗

Comparing the cooling effectiveness of operationalisable urban surface combination scenarios for summer heat mitigation

Extreme summer heat in cities exacerbates the vulnerability of urban communities to heatwaves. Vegetative and reflective urban surfaces can help reduce urban heat. This study investigated the impacts of urban trees, green roofs and cool roofs on heat mitigation during average and extreme summer conditions in temperate oceanic Melbourne, Australia. We simulated the city climate using ‘The Air Pollution Model’ (TAPM) at a 1 km spatial resolution over 10 years, which according to our review of the literature, was the most prolonged period for simulation in Melbourne. During a widespread heatwave event, some of the tested scenarios with combined surface parameters could reduce the extreme values of the energy budget components- sensible heat, latent heat, and storage heat fluxes up to seasonal averages compared to the existing situation for Melbourne (control). The scenario with the highest (reasonable maximum) ground-level vegetation, green roofs, and cool roofs could reduce air temperatures up to 2.4 °C. The simulations suggest that a combined strategy with vegetative and high-albedo surfaces will deliver higher effectiveness with maximum cooling benefits and cost-effectiveness than individual strategies in cities. These results suggest the importance of collaborative strategic planning of urban surfaces to make cities healthier, sustainable, and liveable.

54 ENVIRONMENTAL SCIENCES↗

Surface-cooling effects on compressible boundary-layer instability

The influence of surface cooling on compressible boundary layer instability is discussed theoretically for both viscous and inviscid modes, at high Reynolds numbers. The cooling enhances the surface heat transfer and shear stress, creating a high heat transfer sublayer. This has the effect of distorting and accentuating the viscous Tollmien-Schlichting modes to such an extent that their spatial growth rates become comparable with, and can even exceed, the growth rates of inviscid modes, including those found previously. This is for moderate cooling, and it applies at any Mach number. In addition, the moderate cooling destabilizes otherwise stable viscous or inviscid modes, in particular triggering outward-traveling waves at the edge of the boundary layer in the supersonic regime. Severe cooling is also discussed as it brings compressible dynamics directly into play within the viscous sublayer. All the new cooled modes found involve the heat transfer sublayer quite actively, and they are often multi-structured in form and may be distinct from those observed in previous computational and experimental investigations. The corresponding nonlinear processes are also pointed out with regard to transition in the cooled compressible boundary layer. Finally, comparisons with Lysenko and Maslov's (1984) experiments on surface cooling are presented.

Seddougui, Sharon O.↗

Leading edge film cooling effects on turbine blade heat transfer

An existing three dimensional Navier-Stokes code, modified to include film cooling considerations, has been used to study the effect of spanwise pitch of shower-head holes and coolant to mainstream mass flow ratio on the adiabatic effectiveness and heat transfer coefficient on a film-cooled turbine vane. The mainstream is akin to that under real engine conditions with stagnation temperature = 1900 K and stagnation pressure = 3 MPa. It is found that with the coolant to mainstream mass flow ratio fixed, reducing P, the spanwise pitch for shower-head holes, from 7.5 d to 3.0 d, where d is the hole diameter, increases the average effectiveness considerably over the blade surface. However, when P/d= 7.5, increasing the coolant mass flow increases the effectiveness on the pressure surface but reduces it on the suction surface due to coolant jet lift-off. For P/d = 4.5 or 3.0, such an anomaly does not occur within the range of coolant to mainstream mass flow ratios analyzed. In all cases, adiabatic effectiveness and heat transfer coefficient are highly three-dimensional.

Garg, Vijay K.↗

Surface-cooling effects on compressible boundary-layer instability, and on upstream influence

The influence of surface cooling on compressible boundary-layer instability is discussed theoretically for both viscous and inviscid modes, at high Reynolds numbers, with related questions on upstream influence being considered in an Appendix. The cooling enhances the surface heat transfer and velocity gradient, crating a high-heat-transfer sublayer. This has the effect of distorting and accentuating the viscous Tollmien-Schlichting modes to such an extent that their spatial growth rates becomes comparable with, and can even exceed, the growth rates of inviscid modes, including those found previously. This is for moderate cooling, and it applies at any Mach number. In addition, the moderate cooling destabilizes otherwise stable viscous or inviscid modes, in particular triggering outward-traveling waves at the edge of the boundary layer in the supersonic regime. Severe cooling is also discussed as it brings compressible dynamics directly into play within the viscous sublayer. All the new cooled modes found involve the heat-transfer sublayer quite actively, and they are often multistructured in form and may be distinct from those observed in previous computational and experimental investigations. The corresponding nonlinear processes are also pointed out with regard to transition in the cooled compressible boundary layer. Finally, comparisons with Lysenko and Maslov's (1984) experiments on surface cooling are presented.

Seddougui, S. O.↗

Wall cooling effects on hypersonic transitional/turbulent boundary layers at high Reynolds numbers

The characteristics of a thick hypersonic boundary layer turbulent for a length of 175 cm on a 4 deg sharp wedge were measured. The resulting boundary layer was free from transverse curvature effects and only mildly affected by upstream history effects caused by pressure and wall temperature gradients. Heat-transfer distributions were used to locate regions of laminar, transitional, and turbulent flow at an edge unit Reynolds number of 470,000 cm at wall-to-total temperature ratios from about 0.3 to 1. Wall cooling had little effect on the location of the transition region. Pitot and total temperature profiles and skin-friction measurements were obtained at several locations along the model longitudinal centerline. Mixing length and turbulent Prandtl number distributions were derived from the fully turbulent mean profiles.

Watson, R. D.↗

Stagnation region gas film cooling: Effects of dimensionless coolant temperature

An experimental investigation was conducted to mode the film cooling performance for a turbine vane leading edge using the stagnation region of a cylinder in cross flow. Experiments were conducted with a single row of spanwise angled (25 deg) coolant holes for a range of the coolant blowing ratio and dimensionless coolant temperature with free stream-to-wall temperature ratio approximately 1.7 and Re sub D = 90000. the cylindrical test surface was instrumented with miniature heat flux gages and wall thermocouples to determine the percentage reduction in the Stanton number as a function of the distance downstream from injection (x/d sub 0) and the location between adjacent holes (z/S). Data from local heat flux measurements are presented for injection from a single row located at 5 deg, 22.9 deg, 40.8 deg, from stagnation using a hole spacing ratio of S/d = 5. The film coolant was injected with T sub c T sub w with a dimensionless coolant temperature in the range 1.18 or equal to theta sub c or equal to 1.56. The data for local Stanton Number Reduction (SNR) showed a significant increase in SNR as theta sub c was increased above 1.0.

Bonnice, M. A.↗