Search NASA⌕ Search

SEARCH · Search NASA

Results for “DISPLACEMENT GAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Benchmark notch test for life prediction

The laser Interferometric Strain Displacement Gage (ISDG) was used to measure local strains in notched Inconel 718 test bars subjected to six different load histories at 649 C (1200 F) and including effects of tensile and compressive hold periods. The measurements were compared to simplified Neuber notch analysis predictions of notch root stress and strain. The actual strains incurred at the root of a discontinuity in cyclically loaded test samples subjected to inelastic deformation at high temperature where creep deformations readily occur were determined. The steady state cyclic, stress-strain response at the root of the discontinuity was analyzed. Flat, double notched uniaxially loaded fatigue specimens manufactured from the nickel base, superalloy Inconel 718 were used. The ISDG was used to obtain cycle by cycle recordings of notch root strain during continuous and hold time cycling at 649 C. Comparisons to Neuber and finite element model analyses were made. The results obtained provide a benchmark data set in high technology design where notch fatigue life is the predominant component service life limitation.

Domas, P. A.↗

Dynamic fracture toughness of ceramic composites

The dynamic fracture toughness vs crack velocity relationships of TiB2 particulate-reinforced SiC-matrix and SiC whisker-reinforced Al2O3-matrix composites were determined at both room temperature and 1200 C with impacted, single-edge notched three-point bend specimens. Rapid crack initiation and propagation were monitored by a laser interferometric-displacement gage system. A FEM model that transmitted the measured outside-impact load to the specimen within the furnace was used to characterize the entire loading system-specimen unit. Small differences were measured between the room temperature and 1200 C dynamic responses.

Yang, K. H.↗

MO-FG-303-04: A Smartphone Application for Automated Mechanical Quality Assurance of Medical Accelerators

Purpose: The mechanical quality assurance (QA) of medical accelerators consists of a time consuming series of procedures. Since most of the procedures are done manually – e.g., checking gantry rotation angle with the naked eye using a level attached to the gantry –, it is considered to be a process with high potential for human errors. To remove the possibilities of human errors and reduce the procedure duration, we developed a smartphone application for automated mechanical QA. Methods: The preparation for the automated process was done by attaching a smartphone to the gantry facing upward. For the assessments of gantry and collimator angle indications, motion sensors (gyroscope, accelerator, and magnetic field sensor) embedded in the smartphone were used. For the assessments of jaw position indicator, cross-hair centering, and optical distance indicator (ODI), an optical-image processing module using a picture taken by the high-resolution camera embedded in the smartphone was implemented. The application was developed with the Android software development kit (SDK) and OpenCV library. Results: The system accuracies in terms of angle detection error and length detection error were < 0.1° and < 1 mm, respectively. The mean absolute error for gantry and collimator rotation angles were 0.03° and 0.041°, respectively. The mean absolute error for the measured light field size was 0.067 cm. Conclusion: The automated system we developed can be used for the mechanical QA of medical accelerators with proven accuracy. For more convenient use of this application, the wireless communication module is under development. This system has a strong potential for the automation of the other QA procedures such as light/radiation field coincidence and couch translation/rotations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving optical bench radius measurements using stage error motion data

We describe the application of a vector-based radius approach to optical bench radius measurements in the presence of imperfect stage motions. In this approach, the radius is defined using a vector equation and homogeneous transformation matrix formulism. This is in contrast to the typical technique, where the displacement between the confocal and cat's eye null positions alone is used to determine the test optic radius. An important aspect of the vector-based radius definition is the intrinsic correction for measurement biases, such as straightness errors in the stage motion and cosine misalignment between the stage and displacement gauge axis, which lead to an artificially small radius value if the traditional approach is employed. Measurement techniques and results are provided for the stage error motions, which are then combined with the setup geometry through the analysis to determine the radius of curvature for a spherical artifact. Comparisons are shown between the new vector-based radius calculation, traditional radius computation, and a low uncertainty mechanical measurement. Additionally, the measurement uncertainty for the vector-based approach is determined using Monte Carlo simulation and compared to experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Applications of a quadratic extended interior penalty function for structural optimization

A quadratic extended interior penalty function formulation especially well suited for second-order unconstrained optimization procedures is presented. Analytical derivatives of constraints and an approximate analysis technique are used. Minimum-mass design results are presented which indicate that the combination of these procedures can help make mathematical programming a useful optimization tool for large-order structural design problems with a large number of design variables and multiple constraints. Examples include statically loaded high- and low-aspect-ratio wings simultaneously subjected to stress, displacement, minimum gage and, in some cases, maximum strain constraints.

Haftka, R. T.↗

Results of boron-aluminum thrust structure

Results are presented of testing-to-failure a two member boron-aluminum thrust structure. The structure represented one section of a more complex planar truss and was designed to test the integrity of a diffusion bonded joint. The structure failed at 107 percent of the ultimate design load in the diffusion bond region. Strain gages and displacement transducers were used to measure loads and deflections of the truss. The experimentally derived axial loads, bending moments, and torsion in the various members are presented and compared with predicted values.

Hyer, M. W.↗

An approximation function for frequency constrained structural optimization

The purpose is to examine a function for approximating natural frequency constraints during structural optimization. The nonlinearity of frequencies has posed a barrier to constructing approximations for frequency constraints of high enough quality to facilitate efficient solutions. A new function to represent frequency constraints, called the Rayleigh Quotient Approximation (RQA), is presented. Its ability to represent the actual frequency constraint results in stable convergence with effectively no move limits. The objective of the optimization problem is to minimize structural weight subject to some minimum (or maximum) allowable frequency and perhaps subject to other constraints such as stress, displacement, and gage size, as well. A reason for constraining natural frequencies during design might be to avoid potential resonant frequencies due to machinery or actuators on the structure. Another reason might be to satisy requirements of an aircraft or spacecraft's control law. Whatever the structure supports may be sensitive to a frequency band that must be avoided. Any of these situations or others may require the designer to insure the satisfaction of frequency constraints. A further motivation for considering accurate approximations of natural frequencies is that they are fundamental to dynamic response constraints.

Canfield, R. A.↗

An interferometric strain-displacement measurement system

A system for measuring the relative in-plane displacement over a gage length as short as 100 micrometers is described. Two closely spaced indentations are placed in a reflective specimen surface with a Vickers microhardness tester. Interference fringes are generated when they are illuminated with a He-Ne laser. As the distance between the indentations expands or contracts with applied load, the fringes move. This motion is monitored with a minicomputer-controlled system using linear diode arrays as sensors. Characteristics of the system are: (1) gage length ranging from 50 to 500 micrometers, but 100 micrometers is typical; (2) least-count resolution of approximately 0.0025 micrometer; and (3) sampling rate of 13 points per second. In addition, the measurement technique is non-contacting and non-reinforcing. It is useful for strain measurements over small gage lengths and for crack opening displacement measurements near crack tips. This report is a detailed description of a new system recently installed in the Mechanisms of Materials Branch at the NASA Langley Research Center. The intent is to enable a prospective user to evaluate the applicability of the system to a particular problem and assemble one if needed.

Sharpe, William N., Jr.↗

Design, Optimization, and Evaluation of A1-2139 Compression Panel with Integral T-Stiffeners

A T-stiffened panel was designed and optimized for minimum mass subjected to constraints on buckling load, yielding, and crippling or local stiffener failure using a new analysis and design tool named EBF3PanelOpt. The panel was designed for a compression loading configuration, a realistic load case for a typical aircraft skin-stiffened panel. The panel was integrally machined from 2139 aluminum alloy plate and was tested in compression. The panel was loaded beyond buckling and strains and out-of-plane displacements were extracted from 36 strain gages and one linear variable displacement transducer. A digital photogrammetric system was used to obtain full field displacements and strains on the smooth (unstiffened) side of the panel. The experimental data were compared with the strains and out-of-plane deflections from a high-fidelity nonlinear finite element analysis.

Mulani, Sameer B.↗

Through-the-thickness fatigue crack closure behavior in an aluminum alloy

The variation in fatigue crack closure behavior across the thickness of aluminum alloy specimens was investigated. The specimen geometries examined were the middle crack tension M(T) and compact tension C(T). The fatigue crack closure behavior was determined using remote displacement and strain gages, near tip strain gages, and fatigue striations. A hybrid experimental/numerical method was also used to infer the crack opening loads. The results indicate a variation in crack opening load, of 0.2 in the specimen interior to 0.4 to 0.5 at the surface.

Dawicke, D. S.↗

Through-the-thickness fatigue crack closure behavior in an aluminum alloy

The variation in fatigue crack closure behavior across the thickness of aluminum alloy specimens was investigated. The specimen geometries examined were the middle crack tension M(T) and compact tension C(T). The fatigue crack closure behavior was determined using remote displacement and strain gages, near tip strain gages, and fatigue striations. A hybrid experimental/numerical method was also used to infer the crack opening loads. The results indicate a variation in crack opening load, of 0.2 in the specimen interior to 0.4 to 0.5 at the surface.

Dawicke, D. S.↗

Instrumentation and data acquisition for full-scale aircraft crash testing

The Landing and Impact Dynamics Branch of the NASA Langley Research Center has been conducting full-scale aircraft crash tests since the 1970s. Using a pendulum method, aircraft are suspended by cables from a 240-ft high gantry and swung into the impact surface at various attitudes and velocities. Instrumentation for these tests include on-board high-speed cameras, strain gages, load cells, displacement transducers, and accelerometers. Transducers in the aircraft are hard-wired through a long umbilical cable to the data acquisition room. Up to 96 channels of data can be collected at a typical rate of 4000 samples per second. Data acquisition using an FM multiplexed analog system and a high-speed personal computer based digital system is described.

Jones, Lisa E.↗

Sub-ply level scaling approach investigated for graphite-epoxy composite beam columns

Scale model graphite-epoxy composite specimens were fabricated using the 'sub-ply level' approach and tested as beam-columns under an eccentric axial load to determine the effect of specimen size on flexural response and failure. In the current research project, although the fiber diameters are not scaled, the thickness of the pre-preg material itself has been scaled by adjusting the number of fibers through the thickness of a single ply. Three different grades of graphite-epoxy composite material (AS4/3502) were obtained from Hercules, Inc., in which the number of fibers through the thickness of a single ply was reduced (Grade 190 with 12 to 16 fibers, Grade 95 with 6 to 8 fibers, and Grade 48 with 3 to 4 fibers). Thus, using the sub-ply level approach, a baseline eight ply quasi-isotropic laminate could be fabricated using either the Grade 48 or Grade 95 material and the corresponding full-scale laminate would be constructed from Grade 95 or standard Grade 190 material, respectively. Note that in the sub-ply level approach, the number of ply interfaces is constant for the baseline and full-scale laminates. This is not true for the ply level and sublaminate level scaled specimens. The three grades of graphite-epoxy composite material were used to fabricate scale model beam-column specimens with in-plane dimensions of 0.5*n x 5.75*n, where n=1,2,4 corresponsing to 1/4, 1/2, and full-scale factors. Angle ply, cross ply, and quasi-isotropic laminate stacking sequences were chosen for the investigation and the test matrices for each laminate type are given. Specimens in each laminate family with the same in-plane dimensions but different thicknesses were tested to isolate the influence of the thickness dimension on the flexural response and failure. Also, specific lay-ups were chosen with blocked plies and dispersed plies for each laminate type. Specimens were subjected to an eccentric axial load until failure. The load offset was introduced through a set of hinges which were attached to the platens of a standard load test machine. Three sets of geometrically scaled hinges were used to ensure that scaled loading conditions were applied. This loading condition was chosen because it promotes large flexural deformations and specimens fail at the center of the beam, away from the grip supports. Five channels of data including applied vertical load, end shortening displacement, strain from gages applied back-to-back at the midspan of the beam, and rotation of the hinge from a bubble inclinometer were recorded for each specimen. The beam-column test configuration was used previously to study size effects in ply level scaled composite specimens of the same material system, sizes, and stacking sequences. Thus, a direct comparison between the two scaling approaches is possible. Ply level scaled beam-columns with angle ply, cross ply, and quasi-isotropic lay-ups exhibited no size dependencies in the flexural response, but significant size effects in strength. The reduction in strength with increasing specimen size was not predicted successfully by analysis techniques. It is anticipated that results from this investigation will lead to a better understanding of the strength scale effect in composite structures.

Jackson, Karen E.↗

Local Analysis-Test Correlation Of Tow-Steered Composite Shells With Small Cutouts

The prebuckling and postbuckling behavior of two composite tow-steered shells with small cutouts is assessed using nonlinear dynamic finite element analyses and compared in detail with experimental measurements. The cylindrical shells were manufactured without cutouts using an automated fiber placement system, where the shells’ fiber orientation angles vary continuously around the shell circumference from ±10 degrees on the axially stiff crown and keel, to ±45 degrees on the shear-stiff sides. The first shell with overlaps has laminate thickness variations on the crown and keel that result from application of all 24 tows during each pass of the fiber placement system. The second shell without overlaps uses the fiber placement system’s tow drop/add capability to achieve a more uniform shell wall thickness. An unreinforced cutout representing a passenger door on a commercial aircraft fuselage is machined into the side of each of the two shells. These shells with cutouts were tested in axial compression and buckled elastically in previous work. Detailed nonlinear finite element analysis results are compared with their corresponding measured local load-displacement and load-strain responses in prebuckling, at global buckling, and into a stable postbuckled state. Test data from displacement transducers, strain gages, and digital image correlation are extracted at the centers of the crown and keel, and at the middles of the top and left edges of the cutout. The overall agreement between these measured and analytical responses is excellent in prebuckling through global buckling, and very good from global buckling through postbuckling. As such, the excellent correlation observed here increases confidence in applying tow-steered composites in operational vehicles.

Composites↗

Local Analysis-Test Correlation Of Tow-Steered Composite Shells With Small Cutouts

The prebuckling and postbuckling behavior of two composite tow-steered shells with small cutouts is assessed using nonlinear dynamic finite element analyses and compared in detail with experimental measurements. The cylindrical shells were manufactured without cutouts using an automated fiber placement system, where the shells’ fiber orientation angles vary continuously around the shell circumference from ±10 degrees on the axially stiff crown and keel, to ±45 degrees on the shear-stiff sides. The first shell with overlaps has laminate thickness variations on the crown and keel that result from application of all 24 tows during each pass of the fiber placement system. The second shell without overlaps uses the fiber placement system’s tow drop/add capability to achieve a more uniform shell wall thickness. An unreinforced cutout representing a passenger door on a commercial aircraft fuselage is machined into the side of each of the two shells. These shells with cutouts were tested in axial compression and buckled elastically in previous work. Detailed nonlinear finite element analysis results are compared with their corresponding measured local load-displacement and load-strain responses in prebuckling, at global buckling, and into a stable postbuckled state. Test data from displacement transducers, strain gages, and digital image correlation are extracted at the centers of the crown and keel, and at the middles of the top and left edges of the cutout. The overall agreement between these measured and analytical responses is excellent in prebuckling through global buckling, and very good from global buckling through postbuckling. As such, the excellent correlation observed here increases confidence in applying tow-steered composites in operational vehicles.

Composites↗

Design, Optimization, and Evaluation of Integrally-Stiffened Al-2139 Panel with Curved Stiffeners

A curvilinear stiffened panel was designed, manufactured, and tested in the Combined Load Test Fixture at NASA Langley Research Center. The panel is representative of a large wing engine pylon rib and was optimized for minimum mass subjected to three combined load cases. The optimization included constraints on web buckling, material yielding, crippling or local stiffener failure, and damage tolerance using a new analysis tool named EBF3PanelOpt. Testing was performed for the critical combined compression-shear loading configuration. The panel was loaded beyond initial buckling, and strains and out-of-plane displacements were extracted from a total of 20 strain gages and 6 linear variable displacement transducers. The VIC-3D system was utilized to obtain full field displacements/strains in the stiffened side of the panel. The experimental data were compared with the strains and out-of-plane deflections from a high fidelity nonlinear finite element analysis. The experimental data were also compared with linear elastic finite element results of the panel/test-fixture assembly. Overall, the panel buckled very near to the predicted load in the web regions.

Havens, David↗

Adaptor for Measuring Principal Strains with Tuckerman Strain Gage

An adapter is described which uses three Tuckerman optical strain gages to measure the displacement of the three vortices of an equilateral triangle along lines 120 degrees apart. These displacements are substituted in well-known equations in order to compute the magnitude and direction of the principal strains. Tests of the adaptor indicate that principal strains over a gage length of 1.42 inch may be measured with a systematic error not exceeding 4 percent and a mean observational error of the order of + or minus 0.000006. The maximum observed error in strain was of the order of 0.00006. The directions of principal strains for unidirectional stress were measured with the adaptor with an average error of the order of 1 degree.

INSTRUMENTS-STRAIN GAUGES-RUGE & DE FOREST↗

Buckling Test Results from the 8-Foot-Diameter Orthogrid-Stiffened Cylinder Test Article TA01

Results from the testing of cylinder test article SBKF-P2-CYLTA01 (referred to herein as TA01) are presented. The testing was conducted at the Marshall Space Flight Center (MSFC), November 19‒21, 2008, in support of the Shell Buckling Knockdown Factor (SBKF) Project.i The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF project researchers. TA01 is an 8-foot-diameter (96-inches), 78.0-inch long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch vehicle structures and was designed to exhibit global buckling when subjected to compression loads. Five different load sequences were applied to TA01 during testing and included four sub-critical load sequences, i.e., loading conditions that did not cause buckling or material failure, and one final load sequence to buckling and collapse. The sub-critical load sequences consisted of either uniform axial compression loading or combined axial compression and bending and the final load sequence subjected TA01 to uniform axial compression. Traditional displacement transducers and strain gages were used to monitor the test article response at nearly 300 locations and an advanced digital image correlation system was used to obtain low-speed and high-speed full-field displacement measurements of the outer surface of the test article. Overall, the test facility and test article performed as designed. In particular, the test facility successfully applied all desired load combinations to the test article and was able to test safely into the postbuckling range of loading, and the test article failed by global buckling. In addition, the test results correlated well with initial pretest predictions.

Hilburger, Mark W.↗