Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic Scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Correlating dynamic microstructure to observed color in electrophoretic displays via in situ small-angle x-ray scattering

Electrophoretic deposition (EPD) is an industrially relevant and scalable technique used to form particle deposits from colloidal suspensions. Highly concentrated particle suspensions generally prevent real-time in situ microscopy observations which limit the characterization of EPD films to ex situ, or postprocessed, laboratory techniques. For dynamic systems, such as tunable amorphous photonic crystals (APCs), only reversible deposits are formed during the EPD process. Since reversible deposits cannot be characterized with standard ex situ methods, the particle-particle and particle-field interactions that govern the displayed color and crystallinity of these systems are not well understood. In this paper, we present in situ small-angle x-ray scattering and UV-Vis techniques for measuring both the structural and optical response of an APC under applied electric fields. Furthermore, we also develop a computational model based on colloidal interactions to explain the observed change in the interparticle spacing of APCs due to the applied electric field which correlates to displayed color. Ultimately, this work provides a new in situ characterization method that could be expanded for other dynamic, tunable colloidal systems.

36 MATERIALS SCIENCE↗

Non-Invasive Evaluation of Corneal Abnormalities Using Static and Dynamic Light Scattering

A preliminary study of corneal abnormalities in intact bovine eyes is presented. Twenty-one eyes were treated with chemicals, cotton swabs, and radial and photo-refractive surgeries. Dynamic and static light scattering was performed as a function of the penetration depth into the corneal tissue. Topographical maps of corneal refractive power from untreated and treated corneas were also obtained using videokeratoscopy and results compared. The ultimate aim is to develop the technique of dynamic light scattering (DLS) for clinical applications in early evaluation of corneal complications after laser-assisted in situ keratomileusis (LASIK) surgeries and other corneal abnormalities.

Ansari, Rafat R.↗

Integrated fiber optic probe for dynamic light scattering

An integrated fiber optic probe, comprising a monomode optical fiber fusion spliced to a short length of a graded-index multimode fiber, is fabricated for use as a coherent receiver in dynamic light scattering. The multimode fiber is cleaved to provide a gradient-index fiber lens with a focal length of 125 microns and an f-number close to unity. An integrated fiber receiver is used to measure the intensity-intensity autocorrelation data from a 0.05 percent by weight concentration of an aqueous suspension of polystyrene latex spheres. Analysis of 100 independent data sets indicates that the particle size can be recovered with an accuracy of +/- 1 percent.

Dhadwal, Harbans S.↗

Online submicron particle sizing by dynamic light scattering using autodilution

Efficient production of a wide range of commercial products based on submicron colloidal dispersions would benefit from instrumentation for online particle sizing, permitting real time monitoring and control of the particle size distribution. Recent advances in the technology of dynamic light scattering (DLS), especially improvements in algorithms for inversion of the intensity autocorrelation function, have made it ideally suited to the measurement of simple particle size distributions in the difficult submicron region. Crucial to the success of an online DSL based instrument is a simple mechanism for automatically sampling and diluting the starting concentrated sample suspension, yielding a final concentration which is optimal for the light scattering measurement. A proprietary method and apparatus was developed for performing this function, designed to be used with a DLS based particle sizing instrument. A PC/AT computer is used as a smart controller for the valves in the sampler diluter, as well as an input-output communicator, video display and data storage device. Quantitative results are presented for a latex suspension and an oil-in-water emulsion.

Nicoli, David F.↗

Dynamic Light Scattering of Diabetic Vitreopathy

Diabetes induces pathology throughout the body via nonenzymatic glycation of proteins. Vitreous, which is replete with type 11 collagen, undergoes significant changes in diabetes. The resultant diabetic vitreopathy plays an important role in diabetic retinopathy. Detecting these molecular changes could provide insight into diabetic eye disease as well as molecular effects elsewhere in the body. Human eyes were obtained at autopsy and studied in the fresh, unfixed state. Sclera, choroid, and retina were dissected off the vitreous for dark-field slit microscopy and dynamic light scattering (DLS). For the former, the entire vitreous was exposed. For the latter, only a window at the equator was dissected in some specimens, and the anterior segment was removed leaving the posterior lens capsule intact in others. DLS was performed to determine particle sizes at multiple sites 0.5 mm apart, spanning the globe at the equator (window dissections) and along the antero-posterior axis. Dark-field slit microscopy in diabetic subjects detected findings typical of age-related vitreous degeneration, but at much younger ages than nondiabetic controls. Noninvasive DLS measurements found a greater heterogeneity and larger particle sizes in vitreous of subjects with diabetes as compared to age-matched controls. DLS can detect and quantify the early molecular effects that cause vitreous collagen fibrils to cross-link and aggregate. This could provide valuable insight into ocular and systemic effects of hyperglycemia, because the molecular changes in diabetic vitreopathy could serve as an index of such effects throughout the body. In addition to the diagnostic implications, this methodology could provide a rapid, reproducible way to monitor the response to therapy with novel agents intended to prevent the complications of diabetes on a molecular level.

Sebag, J.↗

Diffuse scattering from dynamically compressed single-crystal zirconium following the pressure-induced α → ω phase transition

The prototypical α → ω phase transition in zirconium is an ideal test bed for our understanding of polymorphism under extreme loading conditions. After half a century of study, a consensus had emerged that the transition is realized via one of two distinct displacive mechanisms, depending on the nature of the compression path. However, recent dynamic-compression experiments equipped with diffraction diagnostics performed in the past few years have revealed new transition mechanisms, demonstrating that our understanding of the underlying atomistic dynamics and transition kinetics is in fact far from complete. We present classical molecular dynamics simulations of the α → ω phase transition in single-crystal zirconium shock compressed along the [0001] axis using a machine-learning-class potential. The transition is predicted to proceed primarily via a modified version of the two-stage Usikov-Zilberstein mechanism, whereby the high-pressure ω phase heterogeneously nucleates at boundaries between grains of an intermediate β phase. We further observe the fomentation of atomistic disorder at the junctions between β grains, leading to the formation of highly defective interstitial material between the ω grains. We directly compare synthetic x-ray diffraction patterns generated from our simulations with those obtained using femtosecond diffraction in recent dynamic-compression experiments, and show that the simulations produce the same unique, anisotropic diffuse scattering signal unlike any previously seen from an elemental metal. Our simulations suggest that the diffuse signal arises from a combination of thermal diffuse scattering, nanoparticlelike scattering from residual kinetically stabilized α and β grains, and scattering from interstitial defective structures. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Light scattering and dynamics of interacting Brownian particles

The relative motions of interacting Brownian particles in liquids may be described as radial diffusion in an effective potential of the mean force. By using a harmonic approximation for the effective potential, the intermediate scattering function may also be evaluated. For polystyrene spheres of 250 A mean radius in aqueous environment at 0.00125 g/cu cm concentration, the results for the calculated mean square displacement are in qualitative agreement with experimental data from photon correlation spectroscopy. Because of the interactions, the functions deviate considerably from the exponential forms for the free particles.

Tsang, T.↗

Attosecond X-Ray Core-Level Chronoscopy of Aromatic Molecules

Attosecond photoemission or photoionization delays are a unique probe of the structure and the electronic dynamics of matter. However, the spectral congestion of valence photoelectron spectra sets fundamental limits to the complexity of systems that can be studied, and the delocalization of valence electron wave functions blurs the spatial origin of the photoelectron wave packet. Using attosecond x-ray pulses from LCLS, we demonstrate the key advantages of measuring core-level delays: The photoelectron spectra remain atomlike, the measurements become element specific, and the observed scattering dynamics originate from a pointlike source when multicenter interference effects are negligible. We exploit these unique features to reveal the effects of changing functional groups (C-H vs N) and symmetry on attosecond scattering dynamics by measuring and calculating the photoionization delays between N−1⁢𝑠 and C−1⁢𝑠 core shells of a series of aromatic azabenzene molecules. Remarkably, the delays increase with the number of nitrogen atoms in the molecule and reveal multiple resonances. We identify two previously unknown mechanisms regulating the associated attosecond dynamics, namely the enhanced confinement of the trapped wave function with the replacement of C-H groups by N atoms and the decrease of the coupling strength among the photoemitted partial waves with increasing symmetry. This study demonstrates the unique opportunities opened by measurements of core-level photoionization delays for unraveling attosecond electron dynamics in complex matter.

Ji, Jia-Bao [Eidgenoessische Technische Hochschule↗

The effects of multispecies Hohlraum walls on stimulated Brillouin scattering, Hohlraum dynamics, and beam propagation

We report experiments and simulations have been conducted to investigate the efficacy of Ta 2 O 5 -lined Hohlraum walls at reducing stimulated Brillouin backscattering (SBS) as well as any subsequent effects on the Hohlraum dynamics and capsule implosions in indirect drive experiments at the National Ignition Facility. Using a 1.1 MJ 400 TW, 351 nm, shaped laser pulse, we measure a 5× reduction in SBS power in the peak of the pulse from the wall on the outer 50° cone beams. The SBS spectrum indicates a reduction in the high-Z spectral signature when using multispecies wall materials. Detailed hydrodynamic simulations were performed using different heat conduction models with flux limiters. Additional simulations were performed on the plasma maps using the 3D parallel paraxial code pF3D to compare backscatter powers between the pure Au and Ta 2 O 5 -lined Hohlraums. Further analysis, using hydrodynamically equivalent plasmas, shows that the SBS reduction is clearly a result of the added ion Landau damping caused by the oxygen ions and not from differences in plasma conditions. The experimental and simulation results also show an increase in the wall plasma expansion when using the Ta 2 O 5 liner leading to a 70% more oblate implosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation and fluid dynamics of scattering aerosols in laser Doppler velocimetry

An experimental study on the particle-fluid interactions of scattering aerosols was performed using monodisperse aerosols of different particle sizes for the application of laser Doppler velocimeters in subsonic turbulence measurements. Particle response was measured by subjecting the particles to an acoustically excited flow field where the particle Reynolds numbers were controlled to simulate the corresponding values of fluid turbulence. The test aerosols were fairly monodisperse with a mean diameter that could be controlled over the size range from 0.1 to 1.0 micron. Experimental results on the generation of a fairly monodisperse aerosol of solid particles and liquid droplets and on the aerosol response in the frequency range 100 Hz to 100 kHz are presented. The present study indicates that a unit density spherical scatterer of 0.3 micron-diameter would be an optimum choice as tracer particles for subsonic air turbulence measurements.

Mazumder, M. K.↗

Dynamic light scattering analysis of solutions from which lysozyme crystals grow

The variation of the friction factor was measured by photon correlation spectroscopy during isothermal growth of chicken egg white lysozyme crystals. It was observed to initially increase to a maximum as crystals formed, and then to decrease to a constant value. The change in the friction factors was measured as a function of temperature at concentrations of lysozyme varying from one sufficiently low that molecular interactions were undetectable to concentrations near those at which crystals grow in solutions, in all cases the ionic strength was below that required for crystallization.

Bishop, J. B.↗

Ophthalmic Diagnostics Using a New Dynamic Light Scattering Fiber Optic Probe

A new fiber optic probe is developed to study different parts of the eye. The probe positioned in front of an eye, delivers a low power light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. We report alpha-crystalline size distributions, as a function of penetration depth, inside the lens and hyaluronic acid molecular size distribution in the vitreous body. In a clinical setting, the probe can be mounted on a slit-lamp apparatus simply by using a H-ruby lens holder. The capability of detecting cataracts, both nuclear and peripheral, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before surgery is necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber, e.g., posterior vitreous detachment.

Ansari, Rafat R.↗

Dynamic Light Scattering Developed to Look Through the Eye's Window Into the Body

Microgravity researcher Dr. Rafat R. Ansari, from the NASA Glenn Research Center, has found that the eye operates much like a camera and is the "window to the body." The eye contains transparent tissue through which light passes, providing us a view of what's going on inside. These transparent tissues represent nearly every tissue type that exists throughout the body. With the correlations and comparisons of these tissues done at Glenn, we hope to improve doctors' ability to diagnose diseases at much earlier stages. The medical community will be able to look noninvasively and quantitatively into a patient's eyes to detect disease before symptoms appear. Since the eye is easily accessed by light, the optical technologies created at Glenn can be used to evaluate its structure and physiology in health, aging, and disease.

Stauber, Laurel J.↗

Dynamic light scattering homodyne probe

An optical probe for analyzing a sample illuminated by a laser includes an input optical fiber operably connectable to the laser where the input optical fiber has an entrance end and an exit end. The probe also includes a first beam splitter where the first beam splitter is adapted to transmit an alignment portion of a light beam from the input fiber exit end and to reflect a homodyning portion of the light beam from the input fiber. The probe also includes a lens between the input fiber exit end and the first beam splitter and a first and a second output optical fiber, each having an entrance end and an exit end, each exit end being operably connectable to respective optical detectors. The probe also includes a second beam splitter which is adapted to reflect at least a portion of the reflected homodyning portion into the output fiber entrance ends and to transmit light from the laser scattered by the sample into the entrance ends.

Meyer, William V.↗

Unraveling the Nature of Vibrational Dynamics in CsPbI 3 by Inelastic Neutron Scattering and Molecular Dynamics Simulations

Cesium lead iodide, CsPbI 3 , is an optoelectronic material of large interest for various technological applications; however, fundamental questions surrounding the vibrational dynamics of this material, especially regarding its role in structural phase transitions, remain to be elucidated. Here, in a combined variable temperature inelastic neutron scattering (INS) and machine-learning based molecular dynamics (MD) simulation study, we show that the stable phase at room temperature, i.e., the nonperovskite δ-phase, exhibits phonon modes with weak anharmonicity with only a weak temperature dependence from 10 K all the way up to the transition to the cubic perovskite α-phase at approximately 600 K. In contrast, the α-phase features anharmonic and damped vibrational dynamics, mainly associated with overdamped tilting motions of the PbI 6 octahedra. Crucially, these overdamped tilting modes, which relate to the tetragonal and orthorhombic distorted perovskite phases (β- and γ-phase, respectively) formed at lower temperatures, stay overdamped by more than 100 K above the respective phase transition. This suggests a flat energy landscape of octahedral tilting motions in α-CsPbI3 and with structural fluctuations on the picosecond time scale with tilting patterns that locally resemble the structure of the β- and γ-phases. The vibrational dynamics of α-CsPbI 3 are also characterized by pronounced anharmonic motions with large thermal displacements of the Cs + ions, but these modes remain underdamped at 600 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗