Search NASA⌕ Search

SEARCH · Search NASA

Results for “EBIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

LIS in low power density for RHIC-EBIS

The Electron Beam Ion Source (EBIS) project at Brookhaven National Laboratory is a new heavy ion preinjector for Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory science programs. Laser Ion Source (LIS), which can supply many heavy ion species using solid targets, is a candidate of a primary ion source provider for RHIC-EBIS. LIS experiment with 5 Hz operation, which is required practically in RHIC-EBIS, was demonstrated to understand the beam property for long operation time. High laser power density decayed the peak current and ion yield with operation time and did not keep the surface of target flat. On the contrary, the beam in low laser power density kept the performance in long operation time.

43 PARTICLE ACCELERATORS↗

The Entropic Braiding Index ( eBI ): A Robust Metric to Account for the Diversity of Channel Scales in Multi‐Thread Rivers

Abstract The Braiding Index ( BI ), defined as the average count of intercepted channels per cross‐section, is a widely used metric for characterizing multi‐thread river systems. However, it does not account for the diversity of channels (e.g., in terms of water discharge) within different cross‐sections, omitting important information related to system complexity. Here we present a modification of BI, the Entropic Braiding Index ( eBI ), which augments the information content in BI by using Shannon Entropy to encode the diversity of channels in each cross section. eBI is interpreted as the number of “effective channels” per cross‐section, allowing a direct comparison with the traditional BI . We demonstrate the potential of the ratio BI/eBI to quantify channel disparity, differentiate types of multi‐thread systems (braided vs. anastomosed), and assess the effect of discharge variability, such as seasonal flooding, on river cross‐section stability.

54 ENVIRONMENTAL SCIENCES↗

An EBIS system for rare isotope science project in Korea

An EBIS system has been designed to be used as a charge breeder for the post accelerator of an ISOL system. An electron gun, which is designed to produce a maximum current of 3 A at the beam energy of 20 kV, will be acquired from the Budker Institute, Novosibirsk. Electron beam optics calculations of the EBIS system as well as of the gun assembly have been performed using PBGUNS and TRAK. A superconducting solenoid with a maximum field of 6 T is to be used to compress the electron beam. A test stand, which includes the gun assembly and a high-power electron beam collector, is being designed and will be ready for the gun test in the end of this year. Charge breeding simulation using EBIS0D and CBSIM has been performed for a few key isotopes.

43 PARTICLE ACCELERATORS↗

First charge breeding results at CARIBU EBIS

The Electron Beam Ion Source (EBIS) developed to breed CARIBU radioactive beams at ATLAS is currently in the off-line commissioning stage. The beam commissioning is being performed using a low emittance surface ionization source producing singly-charged cesium ions. The primary goal of the off-line commissioning is the demonstration of high-efficiency charge breeding in the pulsed injection mode. An overview of the final design of the CARIBU EBIS charge breeder, the off-line commissioning installation and the first results on charge breeding of stable cesium ions are presented and discussed.

43 PARTICLE ACCELERATORS↗

The CARIBU EBIS control and synchronization system

The Californium Rare Isotope Breeder Upgrade (CARIBU) Electron Beam Ion Source (EBIS) charge breeder has been built and tested. The bases of the CARIBU EBIS electrical system are four voltage platforms on which both DC and pulsed high voltage outputs are controlled. The high voltage output pulses are created with either a combination of a function generator and a high voltage amplifier, or two high voltage DC power supplies and a high voltage solid state switch. Proper synchronization of the pulsed voltages, fundamental to optimizing the charge breeding performance, is achieved with triggering from a digital delay pulse generator. The control system is based on National Instruments realtime controllers and LabVIEW software implementing Functional Global Variables (FGV) to store and access instrument parameters. Fiber optic converters enable network communication and triggering across the platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Effects of the CARIBU EBIS Trap Configuration on Extracted Ion Beam Characteristics

Recently the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) Electron Beam Ion Source (EBIS) charge breeder was commissioned at the Argonne Tandem Linear Accelerator System (ATLAS). Different EBIS trap configurations were used to investigate the effects on the extracted beam characteristics - intensities, timing, and energy spread. Results of the commissioning runs are presented; and implications regarding optimization of the charge breeder configuration are discussed.

Dickerson, Clayton↗

Single pass electron beam cooling of gold ions between EBIS LINAC and booster is theoretically possible!

Electron beam cooling is examined as an option to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster. Electron beam parameters are based on experimental data (obtained at BNL) of electron beams extracted from a plasma cathode. Many issues, regarding a low energy high current electron beam that is needed for electron beam cooling to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster, were examined. Computations and some experimental data indicate that none of these issues is a show stopper. Preliminary calculations indicate that single pass cooling is feasible; momentum spread can be reduced by more than an order of magnitude in about one meter. Hence, this option cooling deserves further more serious considerations.

43 PARTICLE ACCELERATORS↗

Injection of large transverse emittance EBIS beams in booster

During the commissioning of EBIS beams in Booster in November 2010 and in April, May and June 2011, it was found that the transverse emittances of the EBIS beams just upstream of Booster were much larger than expected. Beam emittances of 11{pi} mm milliradians had been expected, but numbers 3 to 4 times larger were measured. Here and throughout this note the beam emittance, {pi}{epsilon}{sub 0}, is taken to be the area of the smallest ellipse that contains 95% of the beam. We call this smallest ellipse the beam ellipse. If the beam distribution is gaussian, the rms emittance of the distribution is very nearly one sixth the area of the beam ellipse. The normalized rms emittance is the rms emittance times the relativistic factor {beta}{gamma} = 0.06564. This amounts to 0.12{pi} mm milliradians for the 11{pi} mm milliradian beam ellipse. In [1] we modeled the injection and turn-by-turn evolution of an 11{pi} mm milliradian beam ellipse in the horizontal plane in Booster. It was shown that with the present injection system, up to 4 turns of this beam could be injected and stored in Booster without loss. In the present note we extend this analysis to the injection of larger emittance beams. We consider only the emittance in the horizontal plane. Emittance in the vertical plane and the effects of dispersion are treated in [2].

43 PARTICLE ACCELERATORS↗

Injection of Large Transverse Emittance EBIS Beams in Booster

During the commissioning of EBIS beams in Booster in November 2010 and in April, May and June 2011, it was found that the transverse emittances of the EBIS beams just upstream of Booster were much larger than expected. Beam emittances of 11π mm milliradians had been expected, but numbers 3 to 4 times larger were measured. Here and throughout this note the beam emittance, πϵ 0 , is taken to be the area of the smallest ellipse that contains 95% of the beam. We call this smallest ellipse the beam ellipse. If the beam distribution is gaussian, the rms emittance of the distribution is very nearly one sixth the area of the beam ellipse. The normalized rms emittance is the rms emittance times the relativistic factor βγ = 0.06564. This amounts to 0.12π mm milliradians for the 11π mm milliradian beam ellipse. In we modeled the injection and turn-by-turn evolution of an 11π mm milliradian beam ellipse in the horizontal plane in Booster. It was shown that with the present injection system, up to 4 turns of this beam could be injected and stored in Booster without loss. In the present note we extend this analysis to the injection of larger emittance beams. We consider only the emittance in the horizontal plane. Emittance in the vertical plane and the effects of dispersion are treated in.

43 PARTICLE ACCELERATORS↗

Commissioning and performance of the BNL EBIS LLRF system

The Electron Beam Ion Source (EBIS) LLRF system utilizes the RHIC LLRF upgrade platform to achieve the required functionality and flexibility. The LLRF system provides drive to the EBIS high-level RF system, employs I-Q feedback to provide required amplitude and phase stability, and implements a cavity resonance control scheme. The embedded system provides the interface to the existing Controls System, making remote system control and diagnostics possible. The flexibility of the system allows us to reuse VHDL codes, develop new functionalities, improve current designs, and implement new features with relative ease. In this paper, we will discuss the commissioning process, issues encountered, and performance of the system.

43 PARTICLE ACCELERATORS↗

Performance of the new EBIS preinjector

The construction and initial commissioning phase of a new heavy ion preinjector was completed at Brookhaven in September, 2010, and the preinjector is now operational. This preinjector, using an EBIS source to produce high charge state heavy ions, provided helium and neon ion beams for use at the NASA Space Radiation Laboratory in the Fall of 2010, and gold and uranium beams are being commissioned during the 2011 run cycle for use in RHIC. The EBIS operates with an electron beam current of up to 10 A, to produce mA level currents in 10-40 {micro}s beam pulses. The source is followed by an RFQ and IH linac to accelerate ions with q/m > 0.16 to an energy of 2 MeV/amu, for injection into the Booster synchrotron. The performance of the preinjector is presented, including initial operational experience for the NASA and RHIC programs.

43 PARTICLE ACCELERATORS↗

Commissioning of the EBIS-based heavy ion preinjector at Brookhaven

The status is presented of the commissioning of a new heavy ion preinjector at Brookhaven National Laboratory. This preinjector uses an Electron Beam Ion Source (EBIS), and an RFQ and IH Linac, both operating at 100.625 MHz, to produce 2 MeV/u ions of any species for use, after further acceleration, at the Relativistic Heavy Ion Collider (RHIC) and the NASA Space Radiation Laboratory (NSRL). Among the increased capabilities provided by this preinjector are the ability to produce ions of any species, and the ability to switch between multiple species in 1 second, to simultaneously meet the needs of both science programs. For initial setup, helium beam from EBIS was injected and circulated in the Booster synchrotron. Following this, accelerated Au{sup 32+} and Fe{sup 20+} beams were transported to the Booster injection point, fulfilling DOE requirements for project completion.

43 PARTICLE ACCELERATORS↗

Ion optics of RHIC EBIS

RHIC EBIS has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

43 PARTICLE ACCELERATORS↗

Design study of primary ion provider for RHIC-EBIS

Brookhaven National Laboratory (BNL) has developed the new pre-injector system, Electron Beam Ion Source (EBIS) for Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

43 PARTICLE ACCELERATORS↗

Design and numerical characterization of a crossover EBIS

For the investigation of highly charged ions, a crossover EBIS (XEBIS) was developed at the University of Frankfurt. In contrast to conventional EBIS/T devices the compression of the electron beam is achieved by electrostatic focusing to a crossover point in the interaction region. This concept allows a compact and simple design. Simulations performed with EGUN show a perveance of 2.1×10{sup −7} A/V{sup 3/2} for the realized gun system. In the interaction region the electron beam has a density of around 10 A/cm{sup 2} and a minimum radius of 0.15 mm. The XEBIS has a total length of 112 mm with a trap length of 26 mm. It is designed for electron beam energies of up to 6 keV/q. The storage capacity of the trap region is in the order of 1×10{sup 8} charges. Charge state breeding studies with CBSIM indicate for the noble gases as maximal achievable charge state Ar{sup 16+}, Kr{sup 30+} and Xe{sup 35+}. Thus ion beam currents of around 2.04 nA assuming 50 Hz repetition rate can be expected. The emittance of the extracted beam is approximated to 8 mm mrad. After completion of the construction phase, the XEBIS will be installed for first performance investigations at a dedicated test bench, equipped with a fast Faraday Cup (FC), a retarding field spectrometer, a luminescence screen and optical diagnostics. Subsequently the XEBIS will serve as source for highly charged ions at different experimental setups.

74 ATOMIC AND MOLECULAR PHYSICS↗

EBIS Beam Intensity Online Optimization with GPTune and Offline Analysis with XGBoost

The application of machine learning techniques to accelerator research has led to significant breakthroughs in optimization strategies. This paper presents a pioneering study using a novel machine learning algorithm, GPTune, to optimize beam intensity by adjusting parameters in the EBIS injection and extraction beam lines. Our research demonstrates substantial improvements, achieving a remarkable 22% and 70% increase in beam intensity at two separate measurement locations.

43 PARTICLE ACCELERATORS↗

The Design and Development of The EBIS LEBT Solenoid Power Supply

This power supply was designed and developed at Brookhaven National Laboratory (BNL) as part of a new ion preinjector system called EBIS (Electron Beam Ion Source). It consists of a charging power supply, a capacitor bank, a discharge and recovery circuit and control circuits. The output is fed through cables into a solenoid magnet. The magnet's inductance is 1.9mH. The maximum charging voltage is 1000V. The power supply output is a half sine wave of 13ms duration. The repetition rate is 5Hz. The power supply output can be set to any value between 250A and 1900A in one second in order to accommodate the varying species of ions specified by different machine users.

43 PARTICLE ACCELERATORS↗

The Electron Beam Ion Source (EBIS)

Brookhaven National Lab has successfully developed a new pre-injector system, called the Electron Beam Ion Source, for the Relativistic Heavy Ion Collider (RHIC) and NASA Space Radiation Laboratory science programs. The first of several planned improvemen

43 PARTICLE ACCELERATORS↗