Search NASASearch

SEARCH · Search NASA

Results for “ELECTROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

MECA Electrometer: Overview

The Mars '01 lander contains an electrometer designed to evaluate the electrostatic nature of the Martian regolith and atmosphere. The objective is to gain a better understanding of the hazards related to the human exploration of Mars.

field ion current triboelectric

Electrostatic Regolith Interaction Experiment (ERIE) Electrometer Instrument Development

The Electrostatic Regolith Interaction Experiment (ERIE) is a joint venture between the University of Central Florida (UCF) Center for Microgravity Research (CMR) and the NASA Kennedy Space Center (KSC) Electrostatics and Surface Physics Laboratory (ESPL) seeking to examine charged dust grain behavior in a microgravity environment. Two separate systems have been combined for this suborbital flight experiment: the COLLisions Into Dust Experiment (COLLIDE) developed by the UCF CMR and the Wheel Electrostatic Spectrometer (WES) developed by the NASA KSC ESPL. This combination will advance the understanding of the natural and induced charged grain behavior on the Moon, asteroids, and other low gravity bodies comprised of charged dust particles. COLLIDE retains granular material under vacuum in a shallow tray behind a metal door, which then opens and releases the particles into a larger open volume when microgravity is achieved. The experiment is observed with a high-speed camera, such that the motions of these particles can then be tracked so the kinematics of each grain may be analyzed. The original application for this apparatus was to study cratering events into granular beds, but electrostatic repulsion was detected in the early frames of the video data returned from completed experiments, so a re-flight with a focus on these events was proposed. Agitation of the grains during launch combined with the frictional charge transfer between the grains and the door as it slides open provides an opportunity to use this setup to observe material tribocharging and charged particle behaviors in microgravity. In this updated version, the charged particles released into the chamber will traverse through an electric field produced by high voltage parallel plates and their resulting trajectories will be determined by their net charges. WES was originally developed to characterize the triboelectric properties of the Martian regolith through the contact of a rover wheel with the surface as it rotates. Improvements were made upon this legacy system to develop a sensor suite that will be installed within the COLLIDE door to measure charge transferred between the granular material and insulating disks protruding through the door. These insulator disks span the triboelectric series so, as they slide across the particulate matter when the door opens, each will accumulate a charge consistent with its relative position to the grains within the series. This charge on each insulator is distributed between two capacitances in series with an electrometer amplifier returning an analog voltage proportional to the charge accumulated. Calibration of this system has been performed using applications of known charge to the inputs and characterization of the frictional charge transfer between various regolith simulants and the sensor insulators is currently being examined in the lab.

Electrostatics

Field-effect transistor improves electrometer amplifier

An electrometer amplifier uses a field effect transistor to measure currents of low amperage. The circuit, developed as an ac amplifier, is used with an external filter which limits bandwidth to achieve optimum noise performance.

Munoz, R.

Sensitive electrometer features digital output

Four-stage transistorized electrometer eliminates the need for a logarithmic compression network. It measures very low currents and produces a digital output directly indicative of the input current magnitude.

Doong, H.

Electrometer preamplifier has drift correction feedback

Negative feedback circuit corrects output drift in an electrometer. The negative feedback is used in the no signal state to maintain the output level at zero reference. Drift voltage storage in the signal on state is also used to provide a drift-free readout.

Labarthe, L. C.

A simple electrometer for measuring small photoelectric currents

Quartz-fiber direct-indicating pocket dosimeter is a small-current integrating electrometer. By attaching the photocathode to the quartz fiber terminal and the photoelectron collector to the barrel of the dosimeter and by charging the device to 150 V, a small-current measuring device can be achieved.

Source record

Integrated circuit electrometer and sweep circuitry for an atmospheric probe

The design of electrometer circuitry using an integrated circuit operational amplifier with a MOSFET input is described. Input protection against static voltages is provided by a dual ultra low leakage diode or a neon lamp. Factors affecting frequency response leakage resistance, and current stability are discussed, and methods are suggested for increasing response speed and for eliminating leakage resistance and current instabilities. Based on the above, two practical circuits, one having a linear response and the other a logarithmic response, were designed and evaluated experimentally. The design of a sweep circuit to implement mobility measurements using atmospheric probes is presented. A triangular voltage waveform is generated and shaped to contain a step in voltage from zero volts in both positive and negative directions.

Zimmerman, L. E.

Acceptance testing of the prototype electrometer for the SAMPIE flight experiment

The Solar Array Module Plasma Interaction Experiment (SAMPIE) has two key instruments at the heart of its data acquisition capability. One of these, the electrometer, is designed to measure both ion and electron current from most of the samples included in the experiment. The accuracy requirement, specified by the project's Principal Investigator, is for agreement within 10 percent with a calibrated laboratory instrument. Plasma chamber testing was performed to assess the capabilities of the prototype design. Agreement was determined to be within 2 percent for electron collection and within 3 percent for ion collection.

Hillard, G. Barry

MECA Electrometer: Initial Calibration Experiments

The Mars '01 lander contains an electrometer designed to evaluate the electrostatic nature of the Martian regolith (soil) and atmosphere. The objective is to gain a better understanding of the hazards related to the human exploration of Mars.

MECA Mars electrostatic Martian regolith martian s

Capacitance Probe Resonator for Multichannel Electrometer

A multichannel electrometer voltmeter has been developed that employs a mechanical resonator with voltage-sensing capacitance-probe electrodes that enable high-impedance, high-voltage, radiation-hardened measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. The resonator solution relies on a non-contact, voltage-sensing, sinusoidal-varying capacitor to achieve input impedances as high as 10 petaohms as determined by the resonator materials, geometries, cleanliness, and construction. The resonator is designed with one dominant mechanical degree of freedom, so it resonates as a simple harmonic oscillator and because of the linearity of the variable sense capacitor to displacement, generates a pure sinusoidal current signal for a fixed input voltage under measurement. This enables the use of an idealized phase-lock sensing scheme for optimal signal detection in the presence of noise.

Blaes, Brent R.