Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Imaging nanoscale carrier, thermal, and structural dynamics with time-resolved and ultrafast electron energy-loss spectroscopy

Time-resolved and ultrafast electron energy-loss spectroscopy (EELS) is an emerging technique for measuring photoexcited carriers, lattice dynamics, and near-fields across femtosecond to microsecond timescales. When performed in either a specialized scanning transmission electron microscope or ultrafast electron microscope (UEM), time-resolved and ultrafast EELS can directly image charge carriers, lattice vibrations, and heat dissipation following photoexcitation or applied bias. Yet, recent advances in theoretical calculations and electron optics are often required to realize the full potential of ultrafast EEL spectrum imaging. Here, in this review, we present a comprehensive overview of the recent progress in the theory and instrumentation of time-resolved and ultrafast EELS. We begin with an introduction to the technique, followed by a physical description of the loss function. We outline approaches for calculating and interpreting ground-state and transient EEL spectra spanning low-loss plasmons to core-level excitations analogous to x-ray absorption. We then survey the current state of time-resolved and ultrafast EELS techniques beyond photon-induced near-field electron microscopy, highlighting abilities to image carrier and thermal dynamics. Finally, we examine future directions enabled by emerging technologies, including electron beam monochromation, in situ and operando cells, laser-free UEM, and high-speed direct electron detectors. These advances position time-resolved and ultrafast EELS as a critical tool for uncovering nanoscale dynamic processes in quantum materials and solar energy conversion devices.

Computational methods↗

The incommensurate modulation of tetragonal tungsten bronze quantified by high resolution 4D STEM

Many members of the tetragonal tungsten bronze (TTB) family of oxides display an incommensurate periodic lattice distortion, the nature of which has been the subject of some controversy. Here we present a study of this structural modulation in the relaxor ferroelectric Ba 5 SmSn 3 Nb 7 O 30 (BSSN) by quantitative scanning transmission electron microscopy (STEM). Additionally, we characterize the modulation in BSSN by employing a fast, pixelated direct electron detector to perform high resolution phase contrast STEM imaging of the crystalline lattice. By quantitatively analyzing the images, we visualize the atomic structural correlations present in the material on both the cation and anion sublattices. This analysis reveals the incommensurate structure to have an octahedral tilting pattern and cooperative A2 site cation displacements, analogous to an Ama2 commensurate cell. Finally, we show that the modulation is composed of a structural motif with a period of 3 x $d_{1\bar{1}0}$ and modified by discommensurations, likely arise from frustrated octahedral tilting in the odd-valued periodicity.

Differential phase contrast↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Michel Electron Selection with SPINE for DUNE Far Detector Simulation

Michel electrons are a valuable input for particle detector calibration due to their consistent kinetic energy distribution. This report details the evaluation of a Michel electron identification method's application to simulated data from the DUNE (Deep Underground Neutrino Experiment) far detector. This method, which relies on the neural network-based particle classification software SPINE (Scalable Particle Imaging with Neural Embeddings), was developed and calibrated using simulated data for the SBND (Short-Baseline Neutrino Detector) experiment before being applied to simulated DUNE data from a 1x2x6 subset of far detector modules.

Wilson, Dante [Colorado State U.]↗

First Measurement of $𝜈_𝑒$ and $\bar{𝜈}_𝑒$ Charged-Current Single Charged-Pion Production Differential Cross Sections on Argon Using the MicroBooNE Detector

Understanding electron neutrino interactions is crucial for measurements of neutrino oscillations and searches for new physics in neutrino experiments. We present the first measurement of the flux-averaged $𝜈_𝑒$ + $\bar{𝜈}_𝑒$ charged-current single charged-pion production cross section on argon using the MicroBooNE detector and data from the NuMI neutrino beam. The total cross section is measured to be [0.93 ± 0.13⁢(stat) ± 0.27⁢(syst)] × 10 −39 cm 2 /nucleon at a mean $𝜈_𝑒$ + $\bar{𝜈}_𝑒$ energy of 730 MeV. Differential cross sections are also reported in electron energy, electron and pion angles, and electron-pion opening angle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 keV and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. Furthermore, these results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.

Dark matter detectors↗

Development of the CMS detector for the CERN LHC Run 3

Since the initial data taking of the CERN LHC, the CMSexperiment has undergone substantial upgrades and improvements. Thispaper discusses the CMS detector as it is configured for the thirddata-taking period of the CERN LHC, Run 3, which started in2022. The entire silicon pixel tracking detector was replaced. A newpowering system for the superconducting solenoid was installed. Theelectronics of the hadron calorimeter was upgraded. All the muonelectronic systems were upgraded, and new muon detector stationswere added, including a gas electron multiplier detector. Theprecision proton spectrometer was upgraded. The dedicated luminositydetectors and the beam loss monitor were refurbished. Substantialimprovements to the trigger, data acquisition, software, andcomputing systems were also implemented, including a new hybridCPU/GPU farm for the high-level trigger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SIMS Data Correction Procedure for Quasi‐Simultaneous Arrival ( QSA ) Under‐counting and Ramifications of Misapplication

Isotope geochemistry requires isotope ratios measured using secondary ion mass spectrometry (SIMS) to be made with optimal precision and accuracy. Under some analytical conditions when using electron multiplier detectors, secondary ions may be under‐counted because of quasi‐simultaneous arrival (QSA) at the first dynode. The relative magnitude of the associated QSA correction to raw measured isotopic ratios can be up to seventy permil or more. Therefore, not applying the correction, or misapplication of it could lead to significant inaccuracies in published isotope ratio data. Examples and ramifications of the latter are described in addition to a straightforward procedure for QSA under‐counting correction.

Geochemistry & Geophysics↗

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the Cryogenic Underground Observatory for Rare Events (CUORE) experiment, based on more than 2 metric ton yr of data collected over five years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data-taking conditions. We achieve an average baseline resolution of 2.54 ±0.14 keV FWHM and 1.18 ±0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06±0.05 counts/(keV kg days) and 16±2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 50 ±2% and 26 ±4% at 10 keV and 3 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that ton-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lead tungstate calorimeter of the Jefferson Lab Eta Factory experiment

A new electromagnetic calorimeter (ECAL) consisting of 1596 lead tungstate PbWO 4 scintillating crystals has been fabricated and installed in the experimental Hall D at Jefferson Lab (JLab). The highgranularity, high-resolution calorimeter is required by the JLab Eta Factory experiment, whose main physics goal is to study rare decays of eta mesons. The ECAL replaced the inner part of the forward lead glass calorimeter of the GlueX detector. Signals from the detector will be digitized using twelve-bit flash analog-to-digital converters operated at a sampling rate of 250 MHz. The ECAL is integrated into the trigger system of the GlueX detector using electronics modules designed at JLab. The ECAL is currently at the commissioning stage and should be ready for the physics run in January 2025. We will give an overview of the JEF experiment, the design and construction of the ECAL, and the integration of the detector and its infrastructure into the Hall D experimental setup.

Somov, Alexander [Thomas Jefferson National Accele↗

Automating Testing of DUNE Electronics via a Finite State Machine

The Deep Underground Neutrino Experiment (DUNE) is a flagship international collaboration designed to study neutrinos tiny, nearly massless particles that may hold answers to fundamental questions about the Universe. Fermilab s Robotic Test Stand (RTS) plays a critical role in ensuring the quality of approximately 50,000 Application-Specific Integrated Circuit (ASIC) chips that will be used in DUNE s massive liquid argon detectors. These electronics will be inside the cryostat; therefore, they will need to have a high yield of working chips and low noise. To improve the automation and reliability of the RTS, this project focused on designing and implementing a Python-based finite state machine (FSM) to manage chip handling workflows. The FSM was developed as a modular software framework to coordinate robotic arm movements, manage chip tray positions, and monitor system states during testing. Key features include robust error handling routines, a pause/resume system for safe mid-cycle interruptions, and a simulation mode for iterative testing without hardware dependencies. The system was designed to prepare for seamless integration with RTS hardware components such as the robotic arm and vision system. This integration will streamline collaboration and enable efficient deployment of updates across the six total institutions performing testing. The outcomes of this internship contribute to Fermilab s mission to advance high-energy physics and support the DOE s national goals by directly improving the testing of equipment to be used in DUNE. The project also provided valuable experience in software design and contributing to the success of DUNE.

Kang, Caleb [William Rainey Harper Coll.]↗

Automating Testing of DUNE Electronics via a Finite State Machine

The Deep Underground Neutrino Experiment (DUNE) is a flagship international collaboration designed to study neutrinos—tiny, nearly massless particles that may hold answers to fundamental questions about the Universe. Fermilab’s Robotic Test Stand (RTS) plays a critical role in ensuring the quality of approximately 50,000 Application-Specific Integrated Circuit (ASIC) chips that will be used in DUNE’s massive liquid argon detectors. These electronics will be inside the cryostat; therefore, they will need to have a high yield of working chips and low noise. To improve the automation and reliability of the RTS, this project focused on designing and implementing a Python-based finite state machine (FSM) to manage chip handling workflows. The FSM was developed as a modular software framework to coordinate robotic arm movements, manage chip tray positions, and monitor system states during testing. Key features include robust error handling routines, a pause/resume system for safe mid-cycle interruptions, and a simulation mode for iterative testing without hardware dependencies. The system was designed to prepare for seamless integration with RTS hardware components such as the robotic arm and vision system. This integration will streamline collaboration and enable efficient deployment of updates across the six institutions performing testing. The outcomes of this internship contribute to Fermilab’s mission to advance high-energy physics and support the DOE’s national goals by directly improving the testing of equipment to be used in DUNE. The project also provided valuable experience in software design and contributing to the success of DUNE.

Kang, Caleb [Fermilab]↗

STEM Ptychographic Holography of Electric and Magnetic Potentials

The development of fast an efficient direct electron imaging detectors have enabled the advancement of phase-imaging techniques in STEM such as iterative ptychography. As beneficial as these techniques are to imaging phase objects, the information recorded in the raw data is due to phase gradients across the probe, so it can be challenging to reconstruct slowly varying phase at lower spatial frequencies such as those induced by electric or magnetic potentials within the specimen. STEM holography [1,2] is an interferometric 4D-STEM technique where electrons in the beam are coherently divided into a superposition of two or more spatially separated probes which are then scanned over the specimen. For example, in a two-beam superposition, the two probes form overlapping bright field discs at the detector which then interfere (left of Fig. 1). Furthermore, if one probe passes through vacuum while the other transmits through the specimen, the resulting relative phase shift can be measured by recording shifts in the interference pattern. STEM holography is thus directly sensitive to the phase of the probe relative to the reference beam, and this phase can be measured regardless of the convergence angle of the probe, unlike single beam ptychography.

Biological Sciences↗

Progress on the design of the interaction region of the Electron-Ion Collider EIC

We present an update on the design of the Interaction Region (IR) for the the Electron Ion Collider (EIC) being built at Brookhaven National Laboratory (BNL). The EIC will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV with luminosities of up to 10^34 /cm^2/s. The IR, located at RHIC's IR6, is designed to meet the requirements of the nuclear physics community as outlined in [1]. A second IR is technically feasible but not part of the project.The magnet apertures are sufficiently large to allow desired collision products to reach the far-forward detectors; the electron magnet apertures in the rear direction are chosen to be large enough to pass the synchrotron radiation fan. In the forward direction the electron apertures are large enough for non-Gaussian tails.The paper discusses a number of recent recent changes to the design. The machine free region was recently increased from 9 to 9.5 m to allow for more space in the forward direction for the detector. The superconducting magnets on the forward side now operate at 1.9 K, which helps crosstalk and space issues.

43 PARTICLE ACCELERATORS↗

Measuring the molecular Migdal effect with neutron scattering on diatomic gases

The Migdal effect is a key inelastic signal channel which could be used to detect low-mass dark matter, but it has never been observed experimentally using Standard Model probes. Here we propose a conceptual design for an experiment which could detect the Migdal effect in diatomic molecules through low-energy neutron scattering, and we provide the requirements on the beam spectrum and reducible backgrounds such that a detection may be achieved. The enhancement of the Migdal rate through non-adiabatic couplings, which are absent in isolated atoms, combined with the distinctive photon energies of electronic transitions in CO, suggest that a positive detection of the molecular Migdal effect may be possible with modest beam times at existing neutron facilities. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

Solar Neutrino Detection with a Pixelated Liquid-Argon Time Projection Chamber

This thesis presents a study of low-energy solar neutrino detection using large-scale LArTPCs, focussing on novel pixelated readout technologies. Solar neutrinos offer a unique probe of fundamental neutrino properties and solar physics, but their detection in the MeV range is challenged by backgrounds. We investigate two complementary technologies: SoLAr, which integrates LArPix-based pixelated charge collection with Silicon Photomultipliers (SiPMs) in a hybrid anode design for simultaneous charge and light detection; and Q-Pix, a triggerless pixelated readout architecture based on charge integrate-reset circuits with local clocks, where Reset Time Differences encode ionisation waveforms via time-to-charge conversion. Two SoLAr prototypes were developed and operated, demonstrating VUV-sensitive SiPM performance in liquid argon and accurate charge-light signal matching with a charge detection threshold of $\sim 100 \mathrm{keV}$. We also implement a complete simulation and reconstruction framework, incorporating realistic detector geometry, electron transport, readout response, and detailed signal and background models, including intrinsic argon and radon progeny, as well as site-specific $\gamma$-ray and neutron fluxes. For Q-Pix, we demonstrate that with a pixel size of $4\times 4$ mm$^2$ and a reset threshold of 1 fC ($\sim 0.1475$ MeV), full-scale operation produces data volumes below 1 PB per 10 ktonne-year. For SoLAr, assuming a shielded DUNE-like detector and 100 ktonne-year exposure, we project uncertainties of $0.90\times 10^{-5}$ eV$^2$ on $\Delta m^2_{21}$ and 0.033 on $\sin^2\theta_{12}$, improving to $0.46\times 10^{-5}$ eV$^2$ and 0.025 with 400 kilotonne-year. At this higher exposure, we also obtain a day–night flux asymmetry at the level of $( -5.6 \pm 3.6 ) \%$. Combining Monte Carlo modelling, hardware validation, and advanced reconstruction techniques, this work establishes a path toward next-generation ktonne-scale LArTPCs as observatories for precision solar neutrino physics.

Ruiz Ferreira, Guilherme [Manchester U.] (ORCID:00↗