Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROPHORESIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Preparative electrophoresis experiment design

A multifaceted study supporting the NASA programs to develop a space electrophoresis capability has been conducted. The study involved principally the technique of continuous free electrophoresis. It comprised a critical review of the art, study of new techniques for enhancing resolution and stability, and construction and initial testing of a high resolution cell. The effort resulted in a significant advance in free electrophoresis technique. It has provided also a much improved base for developments exploiting the added advantages of a zero-gravity environment.

Thiehler, A.↗

Preparative electrophoresis of living lymphocytes

Vertical liquid columns containing low molecular weight dextran density gradients can be used for preparative lymphocyte electrophoresis on earth, in simulation of 0 gravity conditions. Another method that has been tested at 1 G, is the electrophoresis of lymphocytes in a upward direction in vertical columns. By both methods up to 10 to the 7th power lymphocytes can be separated at one time in a 30 cm glass column of 8 mm inside diameter, at 12 v/cm, in 2 hours. Due to convection and sedimentation problems, the separation at 1 G is less than ideal, but it is expected that at 0 gravity electrophoresis will prove to be a uniquely powerful cell separation tool. The technical feasibility of electrophoresing inert particles at 0 G has been proven earlier, during the flight of Apollo 16.

Vanoss, C. J.↗

Electrophoresis in space at zero gravity

Early planning for manufacturing operations in space include the use of electrophoresis for purification and separation of biological materials. Greatly simplified electrophoresis apparatus have been flown in the Apollo 14 and 16 missions to test the possibility of stable liquid systems in orbit. Additionally, isoelectric focusing and isotachophoresis are of particular interest as they offer very high resolution and have self-sharpening boundaries. The value of possible space electrophoresis is substantial. For example, present technology permits large fractionation of only a few of blood proteins many fractions, and separated cell populations are needed for research.

Bier, M.↗

Preparative liquid column electrophoresis of T and B lymphocytes at gravity = 1

Vertical liquid columns containing low-molecular-weight dextran density gradients can be used for preparative lymphocyte electrophoresis on earth, in simulation of zero gravity conditions. Another method that has been tested at 1 g, is the electrophoresis of lymphocytes in an upward direction in vertical columns. By both methods up to 100 million lymphocytes can be separated at one time in a 30-cm glass column of 8-mm inside diameter, at 12 V/cm, in two hours. Due to convection and sedimentation problems, the separation at 1 g is less than ideal, but it is expected that at zero gravity electrophoresis will probe to be a uniquely powerful cell separation tool.

Van Oss, C. J.↗

Electrophoresis experiment, experiment MA-014

A continuous, free flow electrophoresis study was conducted during the Apollo Soyuz Test Project mission to investigate and evaluate the increase in sample flow rate and sample resolution achievable in space. The electrophoresis equipment was designed for the separation of four mixtures of biological cells with variable sample flow rates, buffer flow rates, and electric field gradients. Separation quality was assessed by measuring the light from a quartz lamp through the electrophoresis channel and on to a photodiode system. The preliminary results indicate that all monitored systems operated correctly during the experiment. The optical system produced a light that was too bright to discern true cell distributions, but data were received that show a distribution of separated cells.

Hannig, K.↗

Electrophoresis experiment. Experiment MA-014

A continuous free-flow electrophoresis study was conducted during the Apollo-Soyuz Test Project Mission to investigate and evaluate the increase in sample flow rate and sample resolution achievable in space. The electrophoresis equipment was designed for the separation of four mixtures of biological cells with variable sample flow rates, buffer flow rates, and electric field gradients. Separation quality was assessed by measuring the light from a quartz lamp through the electrophoresis channel and onto a photodiode system. The data evaluation indicates that all monitored systems operated correctly during the experiment. The optical system produced a light that was too bright to discern true cell distributions, but final analysis of scientific data by computer processing shows the expected distribution of separated cells.

Hannig, K. H.↗

Preparative cell electrophoresis at 1 and 0 gravity

It is attempted to show that the use of heavy water (D2O) as starting cushion for the cells combines the advantages of the required density difference, with no lasting biochemical or physiochemical influence on the cells. Phosphate buffers of low ionic strength were prepared in distilled water or heavy water. A vertical starch gel electrophoresis was used to support a cylindrical polystyrene electrophoresis tube used for lymphocyte separations, 25 cm in length and 0.75 cm I.D., prepared from a 10 ml disposable pipet. Erythrocyte separations were carried out in a jacketed rectangular plexiglas chamber. It is pointed out that the described preparative D2O gradient electrophoresis method cannot be readily used for the measurement of electrophoretic mobilities for analytical purposes. However, for the preparative separation of cells with only slightly different electrokinetic properties the method appears promising, simple, and entirely inocuous to the cells.

Van Oss, C. J.↗

Studies with sample conductivity, insertion rates, and particle deflection in a continuous flow electrophoresis system

The continuous flow electrophoresis system makes electrophoresis possible in a free-flowing film of aqueous electrolyte medium. The sample continuously enters the electrolyte at the top of the chamber and is subjected to the action of a lateral dc field. This divides the sample into fractions since each component has a distinctive electrophoretic mobility. Tests were made using monodisperse polystyrene latex microspheres to determine optimum sample conductivity, insertion rates and optimum electric field applications as baseline data for future STS flight experiments. Optimum sample flow rates for the selected samples were determined to be approximately 26 micro-liters/min. Experiments with samples in deionized water yielded best results and voltages in the 20 V/cm to 30 V/cm range were optimum. Deflections of formaldehyde fixed turkey and bovine erythrocytes were determined using the continuous flow electrophoresis system. The effects of particle interactions on sample resolution and migration in the chamber was also evaluated.

Williams, G., Jr.↗

Evaluation of the Separability of Monodisperse Polystyrene Latex Microspheres in a Continuous Flow Electrophoresis System

The continuous flow electrophoresis system makes electrophoresis possible in a free flowing film of aqueous electrolyte medium. The sample is introduced at one end of the chamber and is subjected to a lateral dc field. This process separates the sample into fractions since each component has a distinctive electrophoric mobility. Evaluations were made of sample conductivity and buffer conductivity as they affect sample band spread and separation using the Continuous Particle Electrophoresis (CPE) system. Samples were prepared from mixtures of 5 percent and 1 percent polystyrene latex (PSL) microspheres which were .4, .56 and .7 microns in diameter. These were prepared in electrolyte media 1x and 3x the conductivity of the curtain buffer, approximately 150 and 450 micro mhos/cm. Samples with matched conductivities produced greater resolution and less band spread than those with 3x the conductivity of the curtain buffer.

Williams, G., Jr.↗

Development anmd testing of electrophoresis solutions. Task I.1: Development of optimal buffer system

Two buffers were explored for testing: low ionic strength electrophoresis buffer with and without density gradient material. It was found that the electrophoresis routine was better tolerated when Ficoll was present. The results of a viability study of primary human fetal kidney (HFK-1) cells at the first passage are shown. Cell strain HFK-1 was used in several experiments at the first and second passage. The HFK consisted mainly of fibroblasts, and HFK-1 has a high epithelioid cell content. The chromosomes of HFK were examined and found to be euploid. The stock medium for cell electrophoresis is described. In this solution density gradient solutes such as sucrose and Ficoll are dissolved to bring the osmolarity to 0.30. Its ionic strength is less than 0.01M, and its conductivity is usually 0.0011 mho/cm. Methods for viability determination included direct microscopic counting of the percent cells attached and spread within 24 hr of plating test cultures or electrophoretically separated fractions. The Cytograf viability assay concept was tested, and shown that blue stained cells scatter less light into the 0.8 to 3.3 deg angular interval than do unstained cells.

Source record↗

Electrophoresis technology

A new high resolution apparatus designed for space was built as a laboratory prototype. Using a moving wall with a low zeta potential coating, the major sources of flow distortion for an electrophoretic sample stream are removed. Highly resolved fractions, however, will only be produced in space because of the sensitivity of this chamber to buoyancy-induced convection in the laboratory. The second and third flights of the McDonnell Douglas Astronautics Corporation continuous flow electrophoresis system carried samples developed at MSFC intended to evaluate the broad capabilities of free flow electrophoresis in a reduced gravity environment. Biological model materials, hemoglobin and polystyrene latex microspheres, were selected because of their past use as electrophoresis standards and as visible markers for fluid flow due to electroosmosis, spacecraft acceleration or other factors. The dependence of the separation resolution on the properties of the sample and its suspension solution was assessed.

Snyder, R. S.↗

Kidney Cell Electrophoresis

Materials and procedures for microgravity electrophoresis of living human embryonic kidney cells were evaluated, ground support in the form of analytical cell electrophoresis and flow cytometry was provided and cells returned from space flight were analyzed. Preflight culture media, electrophoresis buffer, fraction collection media, temperature profiles, and urokinase assay procedures were tested prior to flight. Electrophoretic mobility distributions of aliquots of the cell population to be fractionated in flight were obtained. The protocol established and utilized is given.

Todd, P.↗

Analysis of free zone electrophoresis of fixed erythrocytes performed in microgravity

A free fluid zone electrophoresis experiment was performed in the microgravity environment of Space Shuttle flight STS-3 (March 1983). The experiment was designed to confirm observations made on the Apollo-Soyuz mission of 1975 and to test the effect of high red blood cell (RBC) concentration on free fluid electrophoresis. Photographic documentation of cell zone progression in one-hour separations of mixtures of formaldehyde-fixed human and rabbit erythrocytes, which were subjected to a field of approximately 13 V/cm in low ionic strength buffer, was analyzed. One of two columns contained 2 x 10 to the 8th RBC/ml; (low concentration), and the other contained 1 x 10 to the 9th RBC/ml (high concentration). The observed and calculated leading edge displacements of the RBC in the two columns were in agreement, indicating the absence of unexpected effects of the reduced gravity environment. Post-flight analyses of the contents of the columns was not possible, and additional microgravity experiments are needed to evaluate the role of particle-particle interactions in concentrated suspensions undergoing electrophoresis.

Snyder, Robert S.↗

Preparative electrophoresis for space

A premise of continuous flow electrophoresis is that removal of buoyancy-induced thermal convection caused by axial and lateral temperature gradients results in ideal performance of these instruments in space. Although these gravity dependent phenomena disturb the rectilinear flow in the separation chamber when high voltage gradients or thick chambers are used, distortion of the injected sample stream due to electrohydrodynamic effects cause major broadening of the separated bands. The electrophoresis separation process is simple, however flow local to the sample filament produced by the applied electric field have not been considered. These electrohydrodynamic flows distort the sample stream and limit the separation. Also, electroosmosis and viscous flow combine to further distort the process. A moving wall concept is being proposed for space which will eliminate and control the disturbances. The moving wall entrains the fluid to move as a rigid body and produces a constant residence time for all samples distributed across the chamber thickness. The moving wall electrophoresis chamber can only be operated in space because there is no viscous flow in the chamber to stabilize against thermal convection.

Rhodes, Percy H.↗

Continuous flow electrophoresis system experiments on shuttle flights STS-6 and STS-7

A space continuous flow electrophoresis system (CFES) was developed that would incorporate specific modifications to laboratory instruments to take advantage of weightlessness. The specific objectives were to use a model sample material at a high concentration to evaluate the continuous flow electrophoresis process in the CFES instrument and compare its separation resolution and sample throughput with related devices on Earth and to expand the basic knowledge of the limitations imposed by fluid flows and particle concentration effects on the electrophoresis process by careful design and evaluation of the space experiment. Hemoglobin and polysaccharide were selected as primary samples. The results from space show a large band spread of the high concentration of the single species of hemoglobin that was due to the mismatch of electrical conductivity between the sample and the buffer. On STS-7 the major objective was to evaluate the influence of the electrical properties of the sample constituents on the resolution of the CFES. As expected, the polystyrene latex microspheres dispersed in a solution with 3 times the electrical conductivity of the curtain buffer separated with a larger band spread than in the 2nd experiment.

Snyder, Robert S.↗

Continuous flow electrophoresis system experiments on shuttle flights STS-6 and STS-7

The development of a space continuous flow electrophoresis system (CFES) is discussed. The objectives of the experiment were: (1) to use a model sample material at a high concentration to evaluate the continuous flow electrophoresis process in the McDonnell Douglass CFES instrument and compare its separation resolution and sample throughput with related devices on Earth, and (2) to expand the basic knowledge of the limitations imposed by fluid flows and particle concentration effects on the electrophoresis process by careful design and evaluation of the space experiment. Hemoglobin and polysaccharide were selected as samples of concentration effects. The results from space show a large band spread of the high concentration of the single species of hemoglobin that was principally due to the mismatch of electrical conductivity between the sample and buffer.

Snyder, Robert S.↗

Preparative electrophoresis for space

A premise of continuous flow electrophoresis is that removal of buoyance-induced thermal convection caused by axial and lateral temperature gradients results in ideal performance of these instruments in space. Although these gravity dependent phenomena disturb the rectilinear flow in the separation chamber when high voltage gradients or thick chamber are used, distortion of the injected sample stream due to electrodynamic effects cause major broadening of the separated bands. The electrophoresis separation process is simple, however flow local to the sample filament produced by the applied electric field were not considered. These electrohydrodynamic flows distort the sample stream and limit the separation. Also, electroosmosis and viscous flow combine to further distort the process. A moving wall concept is being proposed for space which will eliminate and control the disturbances. The moving wall entrains the fluid to move as a rigid body and produces a constant residence time for all samples distributed across the chamber thickness. The moving wall electrophoresis chamber can only be operated in space because there is no viscous flow in the chamber to stabilize against thermal convection.

Rhodes, Percy H.↗

Free flow cell electrophoresis using zwitterionic buffer

Studies of a zwitterionic buffer formulated for cell electrophoresis were done using the McDonnell-Douglas Continuous Flow Electrophoresis System. Standard buffers were analyzed for their stability in the electrical field and the results showed that both buffers tested were inherently unstable. Further, titration studies showed that the standards buffers buffered poorly at the pH employed for electrophoresis. The zwitterionic buffer buffered well at its nominal pH and was shown to be stable in the electrical field. Comparative studies of the buffer with standard cell separation buffers using formalin fixed rabbit and goose red blood cells showed that the zwitterionic buffer gave better resolution of the fixed cells. Studies with viable hybridoma cells showed that buffer Q supported cell viability equal to Hank's Balanced Salt Solution and that hybridoma cells in different stages of the growth cycle demonstrated reproducible differences in electrophoretic mobility.

Rodkey, R. Scott↗