Search NASA⌕ Search

SEARCH · Search NASA

Results for “EQUIPMENT PROTECTION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effects of a conducting sphere moving through a gradient magnetic field.

We examine several conducting spheres moving through a magnetic field gradient. An analytical approximation is derived and an experiment is conducted to verify the analytical solution. The experiment is simulated as well to produce a numerical result. Both the low and high magnetic Reynolds number regimes are studied. Deformation of the sphere is noted in the high Reynolds number case. It is suggested that this deformation effect could be useful for designing or enhancing present protection systems against space debris.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New Beam Loss Monitor for 12 GeV Upgrade

This paper describes a new VME based machine protection Beam Loss Monitor (BLM) signal processing board designed at Jefferson Lab to replace the current CAMAC based BLM board. The new eight-channel BLM signal processor has linear, logarithmic, and integrating amplifiers that simultaneously provide the optimal signal processing for each application. Amplified signals are digitized and then further processed through a Field Programmable Gate Array (FPGA). Combining both the diagnostic and machine protection functions in each channel allows the operator to tune-up and monitor beam operations while the machine protection is integrating the same signal. Other features include extensive built-in-self-test, fast shutdown interface (FSD), and 16-Mbit buffers for beam loss transient play-back. The new VME BLM board features high sensitivity, high resolution, and low cost per channel.

43 PARTICLE ACCELERATORS↗

High Power Testing of RF Cavities for the PEP II B Factory

We describe the process of conditioning and high-power testing of RF cavities for PEP-II. Procedures for vacuum assembly, bakeout and automated processing are described. Interlocks and safety precautions for protection of equipment and personnel are discussed and performance data of tested cavity assemblies are reported. Performance of ancillary components such as windows, couplers and tuners is also discussed. Comments are included on handling, alignment, installation and commissioning issues where appropriate.

43 PARTICLE ACCELERATORS↗

Testing of 3-meter Prototype Fault Current Limiting Cables

Two 3-m long, single-phase cables have been fabricated by Ultera from second generation (2G) superconductor supplied by American Superconductor. The first cable was made with two layers of 2G tape conductor and had a critical current of 5,750 A while the second cable had four layers and a critical current of 8,500 A. AC loss was measured for both cables at ac currents of up to 4 kArms. Ultera performed initial fault current studies of both cables in Denmark with limited currents in the range from 9.1 to 44 kA. Results from these tests will provide a basis for a 25-m long, three-phase, prototype cable to be tested at ORNL early next year and a 300-m long, fault current limiting, superconducting cable to be installed in a ConEd substation in New York City.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Verification of an IGBT Fusing Switch for Over-current Protection of the SNS HVCM

An IGBT based over-current protection system has been developed to detect faults and limit the damage caused by faults in high voltage converter modulators. During normal operation, an IGBT enables energy to be transferred from storage capacitors to a H-bridge. When a fault occurs, the over-current protection system detects the fault, limits the fault current and opens the IGBT to isolate the remaining stored energy from the fault. This paper presents an experimental verification of the over-current protection system under applicable conditions.

43 PARTICLE ACCELERATORS↗

Exe-Guard Project

The exe-Guard Project is an alliance between Dominion Virginia Power (DVP), Sandia National Laboratories (SNL), Dartmouth University, and Schweitzer Engineering Laboratories (SEL). SEL is primary recipient on this project. The exe-Guard project was selected for award under DE-FOA-0000359 with CFDA number 81.122 to address Topic Area of Interest 4: Hardened platforms and Systems. The exe-Guard project developed an antivirus solution for control system embedded devices to prevent the execution of unauthorized code and maintain settings and configuration integrity. This project created a white list antivirus solution for control systems capable of running on embedded Linux® operating systems. White list antivirus methods allow only credible programs to run through the use of digital signatures and hash functions. Once a system’s secure state is baselined, white list antivirus software denies deviations from that state because of the installation of malicious code as this changes hash results. Black list antivirus software has been effective in traditional IT environments but has negative implications for control systems. Black list antivirus uses pattern matching and behavioral analysis to identify system threats while relying on regular updates to the signature file and recurrent system scanning. Black list antivirus is vulnerable to zero day exploits which have not yet been incorporated into a signature file update. System scans hamper the performance of high availability applications, as revealed in NIST special publication 1058 which summarizes the impact of blacklist antivirus on control systems: Manual or “on-demand” scanning has a major effect on control processes in that they take CPU time needed by the control process (Sometimes close to 100% of CPU time). Minimizing the antivirus software throttle setting will reduce but not eliminate this effect. Signature updates can also take up to 100% of CPU time, but for a much shorter period than a typical manual scanning process. Control systems are vulnerable to performance losses if off-the-shelf blacklist antivirus solutions aren’t implemented with care. This investment in configuration in addition to constant decommissioning to perform manual signature file updates is unprecedented and impractical. Additionally, control systems are often disconnected or islanded from the network making the delivery of signature updates difficult. Exe-Guard project developed a white list antivirus solution that mitigated the above drawbacks and allows control systems to cost-effectively apply malware protection while maintaining high reliability. The application of security patches can also be minimized since white listing maintains constant defense against unauthorized code execution. Security patches can instead be applied in less frequent intervals where system decommissioning can be scheduled and planned for. Since control systems are less dynamic than IT environments, the feasibility of maintaining a secure baselined state is more practical. Because upgrades are performed in infrequent, calculated intervals, it allows a new security baseline to be established before the system is returned to service. Exe-Guard built on the efforts of SNL under the Code Seal project. SNL demonstrated prototype Trust Anchors on the project which are independent monitoring and control devices that can be integrated into untrustworthy components. The exe-Guard team started with the lessons learned under this project then designed commercial solution for white list malware protection. Malware is a real threat, even on islanded or un-networked installations, since operators can unintentionally install infected files, plug in infected mass storage devices, or infect a piece of equipment on the islanded local area network that can then spread to other connected equipment. Protection at the device level is one of the last layers of defense in a security-in-depth defense model before an asset becomes compromised. This project provided non-destructive intrusion, isolation and automated response solution, achieving a goal of the Department of Energy (DOE) Roadmap to Secure Control Systems. It also addressed CIP-007-R4 which requires asset owners to employ malicious software prevention tools on assets within the electronic security perimeter. In addition, the CIP-007-R3 requirement for security patch management is minimized because white listing narrows the impact of vulnerabilities and patch releases. The exe-Guard Project completed all tasks identified in the statement of project objective and identified additional tasks within scope that were performed and completed within the original budget. The cost share was met and all deliverables were successfully completed and submitted on time. Most importantly the technology developed and commercialized under this project has been adopted by the Energy sector and thousands of devices with exe-Guard technology integrated in them have now been deployed and are protecting our power systems today

24 POWER TRANSMISSION AND DISTRIBUTION↗

User Impressions and Gait Analysis of Exoskeleton Device Usage in Generalized Tank Farm Activities

Tank farm workers involved in nuclear cleanup activities perform physically demanding tasks, typically while wearing heavy personal protective equipment (PPE). Exoskeleton devices have the potential to bring considerable benefit to this industry but have not been thoroughly studied in the context of nuclear cleanup. In this paper, we examine the performance of exoskeletons during a series of tasks emulating jobs performed on tank farms while participants wore PPE commonly deployed by tank farm workers. The goal of this study was to evaluate the effects of commercially available lower-body exoskeletons on a user’s gait kinematics and user perceptions. Three participants each tested three lower-body exoskeletons in a 70-min protocol consisting of level treadmill walking, incline treadmill walking, weighted treadmill walking, a weight lifting session, and a hand tool dexterity task. Results were compared to a no exoskeleton baseline condition and evaluated as individual case studies. The three participants showed a wide spectrum of user preferences and adaptations toward the devices. Individual case studies revealed that some users quickly adapted to select devices for certain tasks while others remained hesitant to use the devices. Temporal effects on gait change and perception were also observed for select participants in device usage over the course of the device session. Here, device benefit varied between tasks, but no conclusive aggregate trends were observed across devices for all tasks. Evidence suggests that device benefits observed for specific tasks may have been overshadowed by the wide array of tasks used in the protocol.

Tank farm↗

Standardizing Performance Metrics for Building-Level Electrical Distribution Systems

Building-level electrical distribution systems comprise a myriad of current-carrying equipment, conversion devices, and protection devices that deliver power from the utility or local distributed energy resources to end-use building loads. Electric power has traditionally been generated, transmitted, and distributed in alternating current (AC). However, the last decade has seen a significant increase in the integration of native direct current (DC) equipment that has elevated the importance of DC distribution systems. Numerous studies have comparatively examined the performance of various electrical distribution systems in buildings but have failed to achieve uniform conclusions, primarily because of a lack of consistent and analogous performance evaluation methods. This paper aims to fill this gap by providing a standard set of metrics and measurement boundaries to consistently evaluate the performance of AC, DC, or hybrid AC/DC electrical distribution systems. The efficacy of the proposed approach is evaluated on a representative medium-sized commercial office building model with AC distribution and an equivalent hybrid AC/DC and DC distribution model, wherein the AC distribution model is concluded to be the most efficient. The simulation results show variation in computed metrics with different selected boundaries that verify the effectiveness of the proposed approach in ensuring consistent computation of the performance of building-level electrical distribution systems. This paper provides an initial set of guidelines for building energy system stakeholders to adopt appropriate solutions, thus leading to more efficient energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benchtop assessment of sealing efficacy and breathability of additively manufactured (AM) face masks

The onset of the 2019 novel coronavirus disease (COVID-19) led to a shortage of personal protective equipment (PPE), medical devices, and other medical supplies causing many stakeholders and the general public alike to turn to additive manufacturing (AM) as a stopgap when normally accessible devices were not available. However, without a method to test these AM constructs, there continued to be a disconnect between AM suppliers and the community’s needs. The objective of this study was to characterize the pressure drop and leakage of four different publicly available AM face mask models with two filter material combinations, as well as to investigate the impact of frame modification techniques including the use of foam strips and hot-water face forming to improve fit when the masks are donned on manikin head forms. AM face mask frame designs were downloaded from public repositories during the early stages of the COVID-19 pandemic. AM face masks were fabricated and tested on manikin head forms within a custom chamber containing dry aerosolized NaCl. Pressure drops, particle penetration, and leakage were evaluated for various flow rates and NaCl concentrations. Results indicated that filter material combination and frame modification played a major role in the overall performance of the AM face masks studied. Filter material combinations showed improved performance when high filtration fabric was used, and the cross-sectional area of the fabric was increased. AM frame modifications appeared to improve AM face mask leakage performance by as much as 69.6%.

36 MATERIALS SCIENCE↗

CRADA Number NFE-20-08283 with Actinic LLC (CRADA Final Report)

Significant advances have been made in the additive manufacturing (AM) of thermoplastics and optically cured thermosets; however, AM of thermally cured thermosets has lagged. Materials belonging to this class of thermosets, such as silicone rubbers and polyurethanes, are not well represented in the AM space despite their widespread use in medical, defense, and other fields. Ideally, a solution would enable AM of current commercially viable thermally cured thermosets with a speed that is comparable to those already realized for thermoplastics and optically cured thermosets. Realizing this goal will provide several benefits, including: 1. Make thermally cured thermoset designs impossible via casting. 2. Iteration of part designs without investment in new molds. 3. Devices and personal protection equipment, custom-fit to the end-user. 4. Ability to print multifunctional composite materials. 5. Rapid production ability for DoD personnel deployed at forward locations. 6. Simplify supply chains and replace multiple parts with a single raw material. These benefits motivate the development of a commercially viable 3D printer for thermally cured thermosets, based on the technique of photothermal curing. This project further developed a printer capable of printing composites containing commercially available thermally cured polydimethylsiloxane (PDMS), directly yielding cured parts such as boxes, walls, and free-standing overhangs.

36 MATERIALS SCIENCE↗

Electrical Engineering Medium Voltage Protection and Coordination

This presentation covers the basics of the medium voltage electrical system on the Kennedy Space Center. The material will include the process of selective coordination between protective devices and the analysis of a fault that occurred in the electrical system. I will discuss the most common causes of faults found and how the system reacts to the faults at different locations in the subsystem. Explain the importance of the sensitivity and coordination between the devices to protect the equipment it is supplying.

Wessner, Jason R.↗

Real-Time Alignment and Reorientation of Polymer Chains in Liquid Crystal Elastomers

Liquid crystal elastomers (LCEs) exhibit soft elasticity due to the alignment and reorientation of mesogens upon mechanical loading, which provides additional mechanisms to absorb and dissipate energy. This enhanced response makes LCEs potentially transformative materials for biomedical devices, tissue replacements, and protective equipment. However, there is a critical knowledge gap in understanding the highly rate-dependent dissipative behaviors of LCEs due to the lack of real-time characterization techniques that probe the microscale network structure and link it to the mechanical deformation of LCEs. In this work, we employ in situ optical measurements to evaluate the alignment and reorientation degree of mesogens in LCEs. The data are correlated to the quantitative physical analysis using polarized Fourier-transform infrared spectroscopy. The time scale of mesogen alignment is determined at different strain levels and loading rates. The mesogen reorientation kinetics is characterized to establish its relationship with the macroscale tensile strain, and compared to theoretical predictions. Overall, this work provides the first detailed study on the time-dependent evolution of mesogen alignment and reorientation in deformed LCEs. It also provides an effective and more accessible approach for other researchers to investigate the structural-property relationships of different types of polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NREL’s Controllable Grid Interface Saves Time and Resources, Improves Reliability of Renewable Energy Technologies; NREL (National Renewable Energy Laboratory)

The National Renewable Energy Laboratory's (NREL) controllable grid interface (CGI) test system at the National Wind Technology Center (NWTC) is one of two user facilities at NREL capable of testing and analyzing the integration of megawatt-scale renewable energy systems. The CGI specializes in testing of multimegawatt-scale wind and photovoltaic (PV) technologies as well as energy storage devices, transformers, control and protection equipment at medium-voltage levels, allowing the determination of the grid impacts of the tested technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A new characterization of the icing environment below 10,000 feet AGL from 7,000 miles of measurements in supercooled clouds

A growing requirement over the past decade for a new assessment of aircraft icing conditions in wintertime clouds at altitudes up to about 10,000 feet is discussed. The requirement was documented in past workshops and comes primarily from the helicopter community which wants ice-protected rotorcraft to meet increasing demands for all-weather operations. Currently, only a few of the larger helicopters are equipped with certification of ice-protection devices. This is because the current FAA criteria for design and certification of ice-protection equipment results in power and payload penalties that smaller rotorcraft cannot tolerate. The FAA criteria were actually designed for large, transport-category aircraft capable of flying to 20,000 feet or more. For this reason, there have been concerns that the current criteria may be too severe for low-performance aircraft, such as helicopters, which generally operate at altitudes below 10,000 feet.

Jeck, R. K.↗

Command module/service module reaction control subsystem assessment

Detailed review of component failure histories, qualification adequacy, manufacturing flow, checkout requirements and flow, ground support equipment interfaces, subsystem interface verification, protective devices, and component design did not reveal major weaknesses in the command service module (CSM) reaction control system (RCS). No changes to the CSM RCS were recommended. The assessment reaffirmed the adequacy of the CSM RCS for future Apollo missions.

Weary, D. P.↗

Viscoelastic foam cushion

Foam is viscous and elastic with unusual and useful temperature, humidity, and compression responses. Applied weight and pressure distributed equally along entire interface with foam eliminates any pressure points. Flexible urethane foam is ideal for orthopedic and prosthetic devices, sports equipment, furniture, and crash protection.

Kubokawa, C. C.↗