Search NASA⌕ Search

SEARCH · Search NASA

Results for “EQUIPMENT SPECIFICATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

VIlRS Polarization Re-Testing

The VIIRS instrument's polarization sensitivity, for the VIS/NIR bands will be measured again to reduce the uncertainties associated with the initial degree of linear polarization and associated phase measurements. In preparation for this re-test, work at Goddard and Raytheon is ongoing aimed at understanding the limitations of the test equipment, specifically a large spherical integrating sphere, and the sheet polarizes and effects of straylight. The results of the Goddard preliminary tests and ground support equipment characterizations will be presented.

Waluschka, Eugene↗

Detailed design package for design of a video system providing optimal visual information for controlling payload and experiment operations with television

A detailed description of a video system for controlling space shuttle payloads and experiments is presented in the preliminary design review and critical design review, first and second engineering design reports respectively, and in the final report submitted jointly with the design package. The material contained in the four subsequent sections of the package contains system descriptions, design data, and specifications for the recommended 2-view system. Section 2 contains diagrams relating to the simulation test configuration of the 2-view system. Section 3 contains descriptions and drawings of the deliverable breadboard equipment. A description of the recommended system is contained in Section 4 with equipment specifications in Section 5.

Source record↗

Anesthesia during and Immediately after Spaceflight

The increasing presence of humans in space and long-duration manned missions to the Moon or Mars pose novel challenges to the delivery of medical care. Even now, cumulative person-days in space exceed 80 years and preparations for a return to the Moon are actively underway. Medical care after an emergent de-orbit or an accident during a non-nominal landing must not only address the specific disease or injuries but also the challenges posed by physiologic adaptations to microgravity. In the highly autonomous situation of a long-term space mission the situation is even more complex, because personnel, equipment, specific training, and clinical experience are by definition limited. To summarize our current knowledge specifically for anesthetic care during and immediately after spaceflight, we will review physiologic adaptations to microgravity with particular emphasis on the resulting anesthetic risks, discuss veterinary experiences with anesthesia in weightlessness or in animals adapted to microgravity, describe current research that pertains to anesthesia and spaceflight and point out unresolved questions for future investigation.

Seubert, Christoph N.↗

Precision X-ray telescopes on HEAO-C.

Discussion of precision X-ray telescopes which are to be mounted on HEAO-C aircraft designed to study the structure, energy spectra and transient behavior of specific X-ray objects by the scanning and mapping of the sky. The design features and performance characteristics of the three high-resolution X-ray telescopes and their optical systems are considered. Mission equipment specifications and systems diagrams are appended. The HEAO-C mission is planned for launching by the Shuttle in the late 70s, with the capability of pointing to within one arc minute of X-ray sources for long periods of time.

Dailey, C. C.↗

Life sciences payloads analyses and technical program planning studies

Contractural requirements, project planning, equipment specifications, and technical data for space shuttle biological experiment payloads are presented. Topics discussed are: (1) urine collection and processing on the space shuttle, (2) space processing of biochemical and biomedical materials, (3) mission simulations, and (4) biomedical equipment.

Source record↗

Automated space processing payloads study. Volume 2, book 1: Technical report

The extent was investigated to which experiment hardware and operational requirements can be met by automatic control and material handling devices; payload and system concepts that make extensive use of automation technology are defined. Hardware requirements for each experiment were established and tabulated, and investigations of applicable existing hardware were documented. The capabilities and characteristics of industrial automation equipment, controls, and techniques are presented in the form of a summary of applicable equipment characteristics in three basic mutually-supporting formats. Facilities for performing groups of experiments are defined along with four levitation groups and three furnace groups; major hardware elements required to implement them were identified. A conceptual design definition of ten different automated processing facilities is presented along with the specific equipment to implement each facility and the design layouts of the different units. Constraints and packaging, weight, and power requirements for six payloads postulated for shuttle missions in the 1979 to 1982 time period were examined.

Source record↗

A history of development in rotordynamics: A manufacturer's perspective

The subject of rotordynamics and instability problems in high performance turbomachinery has been a topic of considerable industry discussion and debate over the last 15 or so years. This paper reviews an original equipment manufacturer's history of development of concepts and equipment as applicable to multistage centrifugal compressors. The variety of industry user compression requirements and resultant problematical situations tends to confound many of the theories and analytical techniques set forth. The experiences and examples described herein support the conclusion that the successful addressing of potential rotordynamics problems is best served by a fundamental knowledge of the specific equipment. This in addition to having the appropriate analytical tools. Also, that the final proof is in the doing.

Shemeld, David E.↗

Comparison of Commercial Electromagnetic Interface Test Techniques to NASA Electromagnetic Interference Test Techniques

This report documents the development of analytical techniques required for interpreting and comparing space systems electromagnetic interference test data with commercial electromagnetic interference test data using NASA Specification SSP 30237A "Space Systems Electromagnetic Emission and Susceptibility Requirements for Electromagnetic Compatibility." The PSpice computer simulation results and the laboratory measurements for the test setups under study compare well. The study results, however, indicate that the transfer function required to translate test results of one setup to another is highly dependent on cables and their actual layout in the test setup. Since cables are equipment specific and are not specified in the test standards, developing a transfer function that would cover all cable types (random, twisted, or coaxial), sizes (gauge number and length), and layouts (distance from the ground plane) is not practical.

Smith, V.↗

Study of space shuttle EVA/IVA support requirements. Volume 1: Technical summary report

Results are summarized which were obtained for equipment requirements for the space shuttle EVA/IVA pressure suit, life support system, mobility aids, vehicle support provisions, and energy 4 support. An initial study of tasks, guidelines, and constraints and a special task on the impact of a 10 psia orbiter cabin atmosphere are included. Supporting studies not related exclusively to any one group of equipment requirements are also summarized. Representative EVA/IVA task scenarios were defined based on an evaluation of missions and payloads. Analysis of the scenarios resulted in a total of 788 EVA/IVA's in the 1979-1990 time frame, for an average of 1.3 per shuttle flight. Duration was estimated to be under 4 hours on 98% of the EVA/IVA's, and distance from the airlock was determined to be 70 feet or less 96% of the time. Payload water vapor sensitivity was estimated to be significant on 9%-17% of the flights. Further analysis of the scenarios was carried out to determine specific equipment characteristics, such as suit cycle and mobility requirements.

Copeland, R. J.↗

Robotic End Effectors for Hard-Rock Climbing

Special-purpose robot hands (end effectors) now under development are intended to enable robots to traverse cliffs much as human climbers do. Potential applications for robots having this capability include scientific exploration (both on Earth and other rocky bodies in space), military reconnaissance, and outdoor search and rescue operations. Until now, enabling robots to traverse cliffs has been considered too difficult a task because of the perceived need of prohibitively sophisticated planning algorithms as well as end effectors as dexterous as human hands. The present end effectors are being designed to enable robots to attach themselves to typical rock-face features with less planning and simpler end effectors. This advance is based on the emulation of the equipment used by human climbers rather than the emulation of the human hand. Climbing-aid equipment, specifically cams, aid hooks, and cam hooks, are used by sport climbers when a quick ascent of a cliff is desired (see Figure 1). Currently two different end-effector designs have been created. The first, denoted the simple hook emulator, consists of three "fingers" arranged around a central "palm." Each finger emulates the function of a particular type of climbing hook (aid hook, wide cam hook, and a narrow cam hook). These fingers are connected to the palm via a mechanical linkage actuated with a leadscrew/nut. This mechanism allows the fingers to be extended or retracted. The second design, denoted the advanced hook emulator (see Figure 2), shares these features, but it incorporates an aid hook and a cam hook into each finger. The spring-loading of the aid hook allows the passive selection of the type of hook used. The end effectors can be used in several different modes. In the aid-hook mode, the aid hook on one of the fingers locks onto a horizontal ledge while the other two fingers act to stabilize the end effector against the cliff face. In the cam-hook mode, the broad, flat tip of the cam hook is inserted into a non-horizontal crack in the cliff face. A subsequent transfer of weight onto the end effector causes the tip to rotate within the crack, creating a passive, self-locking action of the hook relative to the crack. In the advanced hook emulator, the aid hook is pushed into its retracted position by contact with the cliff face as the cam hook tip is inserted into the crack. When a cliff face contains relatively large pockets or cracks, another type of passive self-locking can be used. Emulating the function of the piece of climbing equipment called a "cam" (note: not the same as a "cam hook"; see Figure 1), the fingers can be fully retracted and the entire end effector inserted into the feature. The fingers are then extended as far as the feature allows. Any weight then transferred to the end effector will tend to extend the fingers further due to frictional force, passively increasing the grip on the feature. In addition to the climbing modes, these end effectors can be used to walk on (either on the palm or the fingertips) and to grasp objects by fully extending the fingers.

Kennedy, Brett↗

Evaluation program for secondary spacecraft cells: Acceptance test of McDonnell-Douglas, Astropower division, 40.0 ampere hour silver-zinc cells

The development of an inorganic separator material for use in construction of 40 ampere-hour silver zinc cells is discussed. Acceptance tests were conducted to determine real quality, physical defects and ampere-hour capacity. All acceptance tests were performed at an ambient temperature of 23 to 27 C at existing relative humidity and atmospheric pressure. Of the 63 cells tested, only one failed to meet the equipment specifications.

Harkness, J. D.↗