Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electric power reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Status of shuttle fuel cell technology program.

The hydrogen-oxygen fuel cell has been proved as an efficient and reliable electrical power supply for NASA manned-space-flight vehicles. It has thus ensured a role in the Space Shuttle Program as the primary electrical power supply for the Orbiter vehicle. The advanced fuel cell technology programs conducted under the management of the NASA Manned Spacecraft Center over the past two years have resulted in a high level of technical readiness in fuel cell power generation to support shuttle mission requirements. These programs have taken advantage of technological developments that have occurred since the designs were completed for the Gemini and Apollo fuel cells.

Rice, W. E.↗

Space Station Freedom power - A reliability, availability, and maintainability assessment of the proposed Space Station Freedom electric power system

A preliminary reliability, availability, and maintainability (RAM) analysis of the proposed Space Station Freedom electric power system (EPS) was performed using the unit reliability, availability, and maintainability (UNIRAM) analysis methodology. Orbital replacement units (ORUs) having the most significant impact on EPS availability measures were identified. Also, the sensitivity of the EPS to variations in ORU RAM data was evaluated for each ORU. Estimates were made of average EPS power output levels and availability of power to the core area of the space station. The results of assessments of the availability of EPS power and power to load distribution points in the space stations are given. Some highlights of continuing studies being performed to understand EPS availability considerations are presented.

Turnquist, S. R.↗

The Diagnostic Challenge Competition: Probabilistic Techniques for Fault Diagnosis in Electrical Power Systems

Reliable systems health management is an important research area of NASA. A health management system that can accurately and quickly diagnose faults in various on-board systems of a vehicle will play a key role in the success of current and future NASA missions. We introduce in this paper the ProDiagnose algorithm, a diagnostic algorithm that uses a probabilistic approach, accomplished with Bayesian Network models compiled to Arithmetic Circuits, to diagnose these systems. We describe the ProDiagnose algorithm, how it works, and the probabilistic models involved. We show by experimentation on two Electrical Power Systems based on the ADAPT testbed, used in the Diagnostic Challenge Competition (DX 09), that ProDiagnose can produce results with over 96% accuracy and less than 1 second mean diagnostic time.

Ricks, Brian W.↗

Combined Electromagnetic and Thermal Design Optimization Studies of In-Slot Cooling for UAM Electric Motors

Urban Air Mobility vehicles will require high specific power and high reliability electric motors. Motor specific power is limited by the temperature limits of stator winding insulation and the motor cooling system’s ability to extract heat from the motor windings. The temperature limits of the stator winding are set by both thermal-chemical aging and thermo-mechanical stresses. In-slot cooling is known to be able to both more effectively reduce the max hotspot temperature in a winding and the thermo-mechanical stress in a winding at a given hotspot temperature relative to external cooling jackets. In this paper, a combined electromagnetic, thermal, and mechanical optimization of in-slot cooled motors for UAM applications is completed. Initial thermal and mechanical studies of in-slot cooling topologies with a reference design were used to down select an in-slot cooled topology for optimization. Optimizations were carried out for both the in-slot cooled topology and a traditional externally cooled motor. Results show that the in-slot cooling topology can achieve a smaller mass than a traditional water jacket cooled design, but at the cost of lower efficiency due to larger required stator thicknesses and correspondingly larger stator iron loss.

Thomas Tallerico↗

Combined Electromagnetic and Thermal Design Optimization Studies of in-Slot Cooling for UAM Electric Motors

Abstract- Urban Air Mobility vehicles will require high specific power and high reliability electric motors. Motor specific power is limited by the temperature limits of stator windings insulation and the motor cooling system’s ability to extract heat from the motor windings. The temperature limits of the stator winding are set by both thermal-chemical aging and thermo-mechanical stresses. In-slot cooling is known to be able to both more effectively reduce the max hotspot temperature in a winding and the thermo-mechanical stress in a winding at a given hotspot temperature relative to external cooling jackets. In this paper, a combined electromagnetic, thermal, and mechanical optimization of in-slot cooled motors for UAM applications is completed. Initial thermal and mechanical studies of in-slot cooling topologies with a reference design were used to down select an in-slot cooled topology for optimization. Optimizations were carried out for a representative UAM mission profile on both the in-slot cooled topology and a traditional externally cooled motor. Results show that the in-slot cooling topology can achieve a smaller mass than a traditional water jacket cooled design, but at the cost of lower efficiency due larger required stator thicknesses and correspondingly larger stator iron loss.

Thomas Tallerico↗

Roller Locking Brake

Roller locking brake is normally braking rotary mechanism allowing free rotation when electromagnet in mechanism energized. Well suited to robots and other machinery which automatic braking upon removal of electrical power required. More compact and reliable. Requires little electrical power to maintain free rotation and exhibits minimal buildup of heat.

Vranish, John M.↗

Reliability and Decarbonization Resource Adequacy and Resilience

The Electric Power Transformation: 2023 MEGA Symposium has a focus on the transition of the energy generation industry to cleaner and climate resilient electric power that can remain cost-effective and reliable. Electric power energy issues abound as the world and the industry address environmental policy challenges—climate change, air quality, waste and water policy, environmental justice, and Environmental Social Governance —and various technology issues related to energy production and delivery, including the latest cutting-edge options. This presentation discusses reliability and decarbonization of the power sector with a focus on resource adequacy and resilience.

Balash, Peter↗

Advanced Power Electronics and Electric Machines

The advanced power electronics and electric machines (APEEM) research group at the National Renewable Energy Laboratory (NREL) has developed world-class experimental and modeling capabilities for designing and evaluating efficient and reliable power electronics and electric machines thermal management systems. They also design, fabricate and characterize advanced power electronics packaging, and are developing state-of-health monitoring techniques. These researchers deliver safe, reliable, high performing, power-dense components that allow seamless integration between renewable energy sources, electric transportation, and the grid, helping to make widespread electric vehicle (EV) adoption and greenhouse gas emissions reduction more feasible. This document outlines the group's major capabilities in the areas of power electronics; module development and characterization; thermal modeling and management; thermomechanical reliability analysis of devices, modules, inverters/converters, and electric machines; physics-of-failure-based reliability analysis; and microelectronics. It also overviews the group's state-of-the-art equipment for fluid-based thermal management; thermal measurement & characterization; thermomechanical reliability analysis; micro- and power electronics measurement & characterization; and prototype fabrication, as well as the group's world-class modeling and simulation capabilities.

advanced gate drivers↗

Optimization, Design, and Demonstration of 1 kW Stirling Controller Using Capacitor-based Power Factor Correction

Free-piston Stirling convertors provide efficient, reliable thermal to electric power conversion, provided they are paired with a reliable controller. This paper outlines work underway on design concepts for kilowatt-class controllers. Using passive power factor correction (PFC) this design explores the possibility of reducing programmatic risk through system simplification. Efficiency is maximized through incorporating wide-bandgap gallium nitride (GaN) switches, and passive PFC volume is minimized through the use of polymer multi-layer capacitors. This work is aimed at exploring new approaches for future Stirling controllers.

Christopher Barth↗

Earth to space power beaming: A new NASA technology initiative

Laser power beaming from the Earth's surface is an innovative and potentially cost-effective option for reliably providing electrical power for applications such as space transportation, Earth-orbiting satellites, and lunar development. The maturation of laser power beaming technology can support low power applications such as upgraded conventional communications satellites in the present decade. Power beaming systems to support extensive lunar base operations that may consume extremely large amounts of power can be implemented early in the 21st century. The synergistic advantages of high-thrust, high specific-impulse electric propulsion may make enhanced, low cost space logistics an area of unique significance for laser power beaming. Economic forces will continue as a driving factor in the selection of major system elements for both commercial applications as well as the avant-garde national space missions envisioned for the 21st century. As a result, the implementation of laser power beaming systems will only take place if they can demonstrate clear economic benefits without sacrificing performance, personnel safety, or the environment. Similarly, the development activities that are a necessary precursor to any operational system will take place only if key industry and government leaders perceive laser power beaming systems as an achievable goal with realistic payoffs in comparison to competing energy options. This paper summarizes NASA's current research to evaluate laser power beaming systems as they apply to applications of greatest interest, and it includes a summary of the current laser power beaming program within the NASA Headquarters Office of Aeronautics and Space Technology. This research effort will quantify some key technical certainties and uncertainties pertaining to laser power beaming systems appropriate for space applications as well as establish a path of development that includes maturation of key technology components for reliable laser and millimeter wave power beaming systems during the 1990's. The program is known as 'SELENE', an acronym for Space Laser Energy.

Rather, John D. G.↗

Structural Analyses of Stirling Power Convertor Heater Head for Long-Term Reliability, Durability, and Performance

Deep-space missions require onboard electric power systems with reliable design lifetimes of up to 10 yr and beyond. A high-efficiency Stirling radioisotope power system is a likely candidate for future deep-space missions and Mars rover applications. To ensure ample durability, the structurally critical heater head of the Stirling power convertor has undergone extensive computational analyses of operating temperatures (up to 650 C), stresses, and creep resistance of the thin-walled Inconel 718 bill of material. Durability predictions are presented in terms of the probability of survival. A benchmark structural testing program has commenced to support the analyses. This report presents the current status of durability assessments.

Halford, Gary R.↗

Bifurcation Analysis of DC Electric Power Systems for Deep Space Exploration Spacecraft

Electric power system reliability is a crucial factor in the application of both manned and unmanned spacecraft that could alter the success of space exploration missions. Understanding the behavior of these electric systems is essential to determine the safe operating conditions, and subsequently, prevent undesired conditions which may cause system-wide blackouts, leaving the spacecraft in a vulnerable position. This study will use bifurcation analysis to determine the behavior of DC spacecraft electric power systems and identify the major causes of voltage instability.

Bifurcation Analysis↗

Energy Paths for the Yurok People

The Yurok Tribe has been working for more than two decades to bring adequate, cost-effective energy services to their Tribal members. With the completion of the electric line extension to Wautec, they are well on their way to an effective and sustainable energy future. However, there is still much work to be done; many Tribal households in the Upper Reservation are still without reliable, affordable electric power. Now the Tribe needs to determine the next steps to realize their energy vision. This Yurok Tribe energy strategic planning study examined electricity usage, costs and infrastructure, as well as electricity needs on the Reservation. It also assessed the Tribe’s energy resources. Equipped with this information, the project team conducted an energy options analysis that examined different project opportunities and identified key projects that are both feasible to implement and will help the Tribe reach its stated Energy Vision. There are still numerous households in the Upper Reservation and adjacent lands that are without grid electric power, and it is likely that most of them will remain disconnected from the grid because of their remoteness. To provide these community members with reliable, affordable, modern energy services their homes will need to be electrified via a robust off-grid energy services program that installs and maintains off-grid energy systems. This is the key need that is explored and addressed in this plan.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A High-Voltage High-Reliability Scalable Architecture for Electric Vehicle Power Electronics (Final Report)

This project developed and demonstrated new composite converter technologies that lead to high power density (> 20 kW/L) at power levels of 10s of kW, 100s of kW, or possibly higher, with fundamental advances in converter efficiency and Q that lead to substantial increases in mean time to failure (MTTF). These advantages were realized through development of new composite converter topologies that perform buck, boost, or other conversion functions and that are scalable to higher voltage and power levels through sharing of voltage and current stresses among multiple dissimilar partial-power converter modules. The project led to experimental demonstration of a125 kW multifunction electric vehicle power conversion system having in-creased dc bus voltage (950 V nominal, 1200 V peak) that interfaces a 200 V to 400 V battery pack, and that includes integrated level 2 wired charging and wireless charging functions. The project incorporated SiC MOSFET modules having switching frequencies in excess of 100 kHz, planar magnetics, a hierarchical control architecture that enables scaling to higher voltages and powers with additional converter modules, and a high-power density in excess of 20 kW/L. The research demonstrated how a more complex converter approach can increase mean-time-to-failure, even though the number of elements is increased. This is achieved through significant reduction of temperature rise through fundamentally superior converter circuit topologies. The research also demonstrated new high power planar magnetics that increase power density. The technology is appropriate to a variety of applications including EV power trains, EV charging, PV inverters, battery storage, and similar areas. These systems potentially can be manufactured in the U.S.

33 ADVANCED PROPULSION SYSTEMS↗

Reliability Aspects of Power-Dense Electric-Drive Power Electronics

This presentation provides a state of the art of electric-drive vehicle power electronics, and covers the APEEM Group research in thermomechanical and reliability aspects of advanced power electronics packaging. Some future directions are identified.

ADVANCED PROPULSION SYSTEMS↗