Search NASA⌕ Search

SEARCH · Search NASA

Results for “FTMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

33 records · Page 2

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Two-stage membrane-based process utilizing highly CO 2 -selective membranes for cost and energy efficient carbon capture from coal flue gas: A process simulation study

Membrane technology for CO 2 capture has become an attractive strategy due to its cost and energy efficiency and low materials costs. In the past decade, membrane-based process designs for post-combustion power plant CO 2 capture have been developed, utilizing existing highly CO 2 -permeable membranes with relatively low CO 2 /N 2 selectivity (<50), and have obtained reasonably economic carbon capture. However, few membrane-based process designs were proposed for moderate to highly CO 2 -selective membranes (CO 2 /N 2 selectivity of 50–300, and >300, respectively), which have vastly emerged in recent years, such as various facilitated transport membranes (FTMs). Herein, we proposed a two-stage membrane-base process design targeting economic carbon capture from coal-fired flue gas. This process design features the utilization of highly CO 2 -selective membranes for one-stage CO 2 enrichment to 95% dry-base purity in the first stage and recycle of the remaining CO 2 by a highly CO 2 -permeable membrane in the second stage, in order to achieve economic CO 2 capture with 90% capture rate and >95% CO 2 product purity. Through an integration-iteration membrane model and the Aspen Plus process simulation, a sensitivity study of operating pressures (feed and permeate pressures) and membrane properties (CO 2 permeance and CO 2 /N 2 selectivity) was conducted. Critical CO 2 /N 2 selectivity of 300–400 was found for the highly CO 2 -selctive membranes to meet the demand for cost and energy efficient results. The lowest possible membrane area of 4.8 × 10 5 m 2 and fractional energy of 19.3% were obtained, which is comparable to or even more attractive than reported membrane-based process designs. Here, this work provides a new membrane process design option for highly CO 2 -selective membranes and gives insights on the influence of membrane performance and operation condition.

42 ENGINEERING↗

Natural Abundance Isotope Ratio Measurements of Organic Molecules Using 21 T FTICR MS

Subtle variations in stable isotope ratios at natural abundance are challenging to measure but can yield critical insights into biological, physical, and geochemical processes. Well established methods, particularly multi-collector, gas-source or plasma isotope ratio mass spectrometry (IRMS) are the gold standard for stable isotope measurement but inherent limitations in these approaches make them ill-suited to determining site-specific and multiply substituted isotopic abundances of all but a few compounds, or to characterizing mixtures or larger intact molecules. Additionally, Fourier transform mass spectrometry (FTMS), namely Orbitrap mass spectrometry, has recently demonstrated the ability to measure natural abundance isotope ratios with chemically informative accuracy and precision. Here, we report the first use of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the accurate (<1‰) and precise (<1‰ standard error) simultaneous determination of $δ$ 13 C and $δ$ 15 N in caffeine isotopologues and provide a discussion of the critical instrumental parameters necessary to make such measurements. Finally, we report the ability to make these measurements with online liquid chromatography, expanding the ability of this technique to explore mixtures in the future.

07 ISOTOPE AND RADIATION SOURCES↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Speed Intact Protein Characterization Using 4X Frequency Multiplication, Ion Trap Harmonization, and 21 Tesla FTICR-MS

Mass spectrometric characterization of large biomolecules, such as intact proteins, requires the specificity afforded by ultra-high resolution mass measurements performed at both the intact mass and product ion levels. Although the performance of time-of-flight mass analyzers is steadily increasing, the choice of mass analyzer for large biomolecules (e.g. proteins >50 kDa) is generally limited to the Fourier transform family of mass analyzers, such as Orbitrap and ion cyclotron resonance (FTICR-MS) with the latter providing unmatched mass resolving power and measurement accuracy. Yet, protein analyses using FTMS are largely hindered by the low acquisition rates of ultra-high resolution spectra. Frequency multiple detection schemes enable FTICR-MS to overcome this fundamental barrier and achieve resolving powers and acquisition speeds 4X greater than the limits imposed by magnetic field strength. Here we expand upon earlier work on the implementation of this technique for biomolecular characterization. We report the coupling of 21T FTICR-MS, 4X frequency multiplication, ion trapping field harmonization technology, and spectral data processing methods to achieve unprecedented acquisition rates and resolving power in mass spectrometry of large intact proteins. Isotopically resolved spectra of multiply charged ubiquitin ions were acquired using detection periods as short as 12 ms. Large proteins such as apo-transferrin (MW=78 kDa) and monoclonal antibody (MW=150 kDa) were isotopically resolved with detection periods of 384 ms and 768 ms, respectively. These results illustrate the future capability of accurate characterization of large proteins on time-scales compatible with online separations.

Shaw, Jared B.↗

Adverse Effect of Polyelectrolyte Complexation on the CO 2 Permeability of Polyvinylamine Copolymers

Polyvinylamine (PVAm) is one of the most studied polymers for facilitated transport membranes (FTMs) in CO 2 separation applications. In this study, poly(N-vinylformamide) (PNVf) was hydrolyzed to prepare a range of PNVf-PVAm copolymer compositions and the effect of PVAm fraction on CO 2 permeability and CO 2 /N 2 selectivity these polymers examined. The most permeable film was the polymer containing 52 mol% PVAm units with a CO 2 permeability of 353 Barrer and CO 2 /N 2 selectivity of 96, when tested at 60°C with humidified 14/86 CO 2 /N 2 mixed gas. Despite containing a higher loading of amines to act as CO 2 carriers, higher PVAm contents yielded significantly lower CO 2 permeability, without a loss of selectivity. This trend was not due to polymer crystallization since none of the PVAm films exhibited crystallinity in X-ray diffraction analysis. The loss of gas permeability at high PVAm content was instead due to strong polyelectrolyte interactions between polymer chains formed when PVAm reacts with CO 2 . Since only the PVAm units are ionized upon reaction with CO 2 , with the PNVf units remaining neutral, the density of these ionic effects increased as PVAm content increased, leading to increased resistance to gas permeation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Top-Down Characterization of the Post-Translationally Modified Intact Periplasmic Proteome from the Bacterium Novosphingobium aromaticivorans

The periplasm of Gram-negative bacteria is a dynamic and physiologically important subcellular compartment where the constant exposure to potential environmental insults amplifies the need for proper protein folding and modifications. Top-down proteomics analysis of the periplasmic fraction at the intact protein level provides unrestricted characterization and annotation of the periplasmic proteome, including the post-translational modifications (PTMs) on these proteins. Here, we used single-dimension ultra-high pressure liquid chromatography coupled with the Fourier transform mass spectrometry (FTMS) to investigate the intact periplasmic proteome of Novosphingobium aromaticivorans . Our top-down analysis provided the confident identification of 55 proteins in the periplasm and characterized their PTMs including signal peptide removal, N-terminal methionine excision, acetylation, glutathionylation, pyroglutamate, and disulfide bond formation. This study provides the first experimental evidence for the expression and periplasmic localization of many hypothetical and uncharacterized proteins and the first unrestrictive, large-scale data on PTMs in the bacterial periplasm.

Wu, Si↗

Quantitative Analysis of Human Salivary Gland-Derived Intact Proteome Using Top-Down Mass Spectrometry

There are several notable challenges inherent to fully characterizing the entirety of the human saliva proteome using bottom-up approaches, including polymorphic isoforms, post-translational modifications, unique splice variants, deletions, and truncations. To address these challenges, we have developed a top-down based liquid chromatography-mass spectrometry (LC-MS) approach, which cataloged 20 major human salivary proteins with a total of 83 proteoforms, containing a broad range of post-translational modifications. Among these proteins, several previously reported disease biomarker proteins were identified at the intact protein level, such as beta-2 microglobulin (B2M). In addition, intact glycosylated proteoforms of several saliva proteins were also characterized, including intact N-glycosylated protein prolactin inducible protein (PIP) and O-glycosylated acidic protein rich protein (aPRP). These characterized proteoforms constitute an intact saliva proteoform database, which was used for quantitative comparison of intact salivary proteoforms among six healthy individuals. Human parotid (PS) and submandibular/sublingual gland (SMSL) secretion samples (2 μg of protein each) from six healthy individuals were compared using RPLC coupled with the 12T FTICR mass spectrometer. Significantly different protein and PTM patterns were resolved with high reproducibility between PS and SMSL glands. The results from this study provide further insight into the potential mechanisms of PTM pathways in oral glandular secretion, expanding our knowledge of this complex yet easily accessible fluid. Intact protein LC-MS approach presented herein can potentially be applied for rapid and accurate identification of biomarkers from only a few microliters of human glandular saliva.

Environmental Molecular Sciences Laboratory↗

Single-Cell Metabolomics with Rapid Determination of Chemical Formulas from Isotopic Fine Structures

Metabolomic measurements can provide functional readouts of cellular states and phenotypes. Here, we present a protocol for single-cell metabolomics that permits direct untargeted detection of a broad number of metabolites under ambient conditions, without the need for sample processing, and with high confidence in the discovery and identification of the molecular formulas for detected metabolites. This protocol describes combining fiber-based laser ablation electrospray ionization (f-LAESI) with a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer (21T-FTICR-MS) to obtain high confidence molecular formula information about detected metabolites. The f-LAESI source utilizes mid-infrared laser ablation through a sharp optical fiber tip, affording direct ambient analysis of cells without the need for sample processing. Using the 21T-FTICR-MS as a mass analyzer enabled measurement of the isotopic fine structure (IFS) for numerous metabolites simultaneously from single cells, and the IFSs were in turn computationally processed to rapidly determine the corresponding elemental compositions. This metabolomics technique complements other single cell omics measurement methods, helping to resolve complex molecular interactions that take place within cells unattainable from single cell transcriptomic and proteomics methods.

mass spectrometry, FTICR, FTMS, ultrahigh mass res↗

FT-ICR MS analysis of blended pine-microalgae feedstock HTL biocrudes

Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is utilized for direct comparison of the chemical composition of biocrudes generated from the hydrothermal liquefaction of 100% pine, 100% algae, 75:25 pine:algae, and 50:50 pine:algae feedstocks. This analysis reveals that the of the 72:25 and 50:50 pine:algal HTL biocrudes is essentially a composite of the two parent feeds (i.e., pine and algae) with a lower relative abundance of Ox species and a higher relative abundance of nitrogen-containing species than the pine HTL biocrude. Alternatively, the biocrude blends have a lower relative abundance of nitrogen-containing species where N>2 than the algal HTL biocrude. The 75:25 pine:algal HTL biocrude has more elemental formulae in common with the pine HTL biocrude than the 50:50 blend; however, both blends have more elemental formulae in common with the algal HTL biocrude. Interestingly, >20% of the elemental formulae assigned to monoisotopic peaks within the 75:25 and 50:50 biocrude blends are species not present in either the pine or algal HTL biocrudes. The highest relative abundance of these new species belong to the N2O4-6 classes, which correspond to heteroatom classes with a moderate number of nitrogen atoms and higher number of oxygen atoms per molecules than the species within the pure algal HTL biocrude. Compositionally, the novel species have the same structural motif but are of higher DBE and carbon numbers than the species within the algal HTL biocrude. These original species are most likely generated from reactions between molecules from both feeds, which results in compounds wotj higher oxygen content than typically seen in the algal HTL biocrude but also higher nitrogen contents than observed in the pine HTL biocrude.

FT-ICR↗

The gas-phase bis-uranyl nitrate complex [(UO2)(2)(NO3)(5)](-): infrared spectrum and structure

The infrared spectrum of the bis-uranyl nitrate complex [(UO{sub 2}){sub 2}(NO{sub 3}){sub 5}]{sup -} was measured in the gas phase using multiple photon dissociation (IRMPD). Intense absorptions corresponding to the nitrate symmetric and asymmetric vibrations, and the uranyl asymmetric vibration were observed. The nitrate nu3 vibrations indicate the presence of nitrate in a bridging configuration bound to both uranyl cations, and probably two distinct pendant nitrates in the complex. The coordination environment of the nitrate ligands and the uranyl cations were compared to those in the mono-uranyl complex. Overall, the uranyl cation is more loosely coordinated in the bis-uranyl complex [(UO{sub 2}){sub 2}(NO{sub 3}){sub 5}]{sup -} compared to the mono-complex [UO{sub 2}(NO{sub 3}){sub 3}]{sup -}, as indicated by a higher O-U-O asymmetric stretching (nu3) frequency. However, the pendant nitrate ligands are more strongly bound in the bis-complex than they are in the mono-uranyl complex, as indicated by the {nu}{sub 3} frequencies of the pendant nitrate, which are split into nitrosyl and O-N-O vibrations as a result of bidentate coordination. These phenomena are consistent with lower electron density donation per uranyl by the nitrate bridging two uranyl centers compared to that of a pendant nitrate in the mono-uranyl complex. The structure was calculated using density functional theory (B3LYP functional), which produced a structure in which the two uranyl molecules bridged by a single nitrate coordinated in a bis-bidentate fashion. Each uranyl molecule was coordinated by two pendant nitrate ligands. The corresponding vibrational spectrum was in excellent agreement with the IRMPD measurement, confirming the structural assignment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interlaboratory Study for Characterizing Monoclonal Antibodies by Top-Down and Middle-Down Mass Spectrometry

The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product’s primary structure reliably and reproducibly. The major objective of the present study was to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up approaches, such as confirming protein integrity, sequencing variable domains, ruling out artefacts, and revealing modifications and their locations. A panel of three mAbs was selected and centrally provided to twenty laboratories worldwide for the analysis: Sigma mAb standard (SiLuLite), NIST mAb standard, and the therapeutic mAb Herceptin (trastuzumab). A variety of different MS instrument platforms and ion dissociation techniques were employed. Overall, the present study confirms that MD/TD MS strategies are valuable and readily available tools in laboratories worldwide. They provide complementary information to the bottom-up approach and can add unique information, which may be crucial for comprehensive mAb characterization. The current limitations, as well as possible solutions to overcome them, are also outlined. One of the limitations revealed by the results of the present study is that the expert knowledge in both experiment and data analysis is indispensable to practice TD/MD MS, but the number of TD/MD MS experts is still very low.

59 BASIC BIOLOGICAL SCIENCES↗

PyKrev: A Python Library for the Analysis of Complex Mixture FT-MS Data

In this study, we present PyKrev, a Python library for the analysis of complex mixture Fourier transform mass spectrometry (FT-MS) data. PyKrev is a comprehensive suite of tools for analysis and visualization of FT-MS data after formula assignment has been performed. These comprise formula manipulation and calculation of chemical properties, intersection analysis between multiple lists of formulas, calculation of chemical diversity, assignment of compound classes to formulas, multivariate analysis, and a variety of visualization tools producing van Krevelen diagrams, class histograms, PCA score, and loading plots, biplots, scree plots, and UpSet plots. The library is showcased through analysis of hot water green tea extracts and Scotch whisky FT-ion cyclotron resonance-MS data sets. PyKrev addresses the lack of a single, cohesive toolset for researchers to perform FT-MS analysis in the Python programming environment encompassing the most recent data analysis techniques used in the field.

47 OTHER INSTRUMENTATION↗

An integrated top-down and bottom-up strategy for characterization protein isoforms and modifications

Bottom-up and top-down strategies are two commonly used methods for mass spectrometry (MS) based protein identification; each method has its own advantages and disadvantages. In this chapter, we describe an integrated top-down and bottom-up approach facilitated by concurrent liquid chromatography-mass spectrometry (LC-MS) analysis and fraction collection for comprehensive high-throughput intact protein profiling. The approach employs a high resolution reversed phase (RP) LC separation coupled with LC eluent fraction collection and concurrent on-line MS with a high field (12 Tesla) Fourier-transform ion cyclotron resonance (FTICR) mass spectrometer. Protein elusion profiles and tentative modified protein identification are made using detected intact protein mass in conjunction with bottom-up protein identifications from the enzymatic digestion and analysis of corresponding LC fractions. Specific proteins of biological interest are incorporated into a target ion list for subsequent off-line gas-phase fragmentation that uses an aliquot of the original collected LC fraction, an aliquot of which was also used for bottom-up analysis.

59 BASIC BIOLOGICAL SCIENCES↗