Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filter Absorption Coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Advancements in the Aerosol Robotic Network (AERONET) Version 3 database – automated near-real-time quality control algorithm with improved cloud screening for Sun photometer aerosol optical depth (AOD) measurements

The Aerosol Robotic Network (AERONET) has provided highly accurate, ground-truth measurements of the aerosol optical depth (AOD) using Cimel Electronique Sun–sky radiometers for more than 25 years. In Version 2 (V2) of the AERONET database, the near-real-time AOD was semiautomatically quality controlled utilizing mainly cloud-screening methodology, while additional AOD data contaminated by clouds or affected by instrument anomalies were removed manually before attaining quality-assured status (Level 2.0). The large growth in the number of AERONET sites over the past 25 years resulted in significant burden to the manual quality control of millions of measurements in a consistent manner. The AERONET Version 3 (V3) algorithm provides fully automatic cloud screening and instrument anomaly quality controls. All of these new algorithm updates apply to near-real-time data as well as post-field-deployment processed data, and AERONET reprocessed the database in 2018. A full algorithm redevelopment provided the opportunity to improve data inputs and corrections such as unique filter-specific temperature characterizations for all visible and near-infrared wavelengths, updated gaseous and water vapor absorption coefficients, and ancillary data sets. The Level 2.0 AOD quality-assured data set is now available within a month after post-field calibration, reducing the lag time from up to several months. Near-real-time estimated uncertainty is determined using data qualified as V3 Level 2.0 AOD and considering the difference between the AOD computed with the pre-field calibration and AOD computed with pre-field and post-field calibration. This assessment provides a near-real-time uncertainty estimate for which average differences of AOD suggest a +0.02 bias and one sigma uncertainty of 0.02, spectrally, but the bias and uncertainty can be significantly larger for specific instrument deployments. Long-term monthly averages analyzed for the entire V3 and V2 databases produced average differences (V3–V2) of +0.002 with a ±0.02 SD (standard deviation), yet monthly averages calculated using time-matched observations in both databases were analyzed to compute an average difference of −0.002 with a ±0.004 SD. The high statistical agreement in multiyear monthly averaged AOD validates the advanced automatic data quality control algorithms and suggests that migrating research to the V3 database will corroborate most V2 research conclusions and likely lead to more accurate results in some cases.

David M. Giles↗

Rare-earth doped transparent ceramics for spectral filtering and quantum information processing

Homogeneous linewidths below 10 kHz are reported for the first time in high-quality Eu{sup 3+} doped Y {sub 2}O{sub 3} transparent ceramics. This result is obtained on the {sup 7}F{sub 0}→{sup 5}D{sub 0} transition in Eu{sup 3+} doped Y {sub 2}O{sub 3} ceramics and corresponds to an improvement of nearly one order of magnitude compared to previously reported values in transparent ceramics. Furthermore, we observed spectral hole lifetimes of ∼15 min that are long enough to enable efficient optical pumping of the nuclear hyperfine levels. Additionally, different Eu{sup 3+} concentrations (up to 1.0%) were studied, resulting in an increase of up to a factor of three in the peak absorption coefficient. These results suggest that transparent ceramics can be useful in applications where narrow and deep spectral holes can be burned into highly absorbing lines, such as quantum information processing and spectral filtering.

36 MATERIALS SCIENCE↗

Acousto-optic filtering of lidar signals

The predominant part of the noise in lidar receivers is created by the background radiation; therefore, one of the most important elements of the receiving optics is a spectrally selecting filter placed in front of the photodetector. Interference filters are usually used to transmit a given wavelength. Specific properties of the interference filters, such as simple design, reliability, small size, and large aperture, combined with high transmission coefficient and narrow spectral band, make them the preferred spectral device in many cases. However, problems arise in applications such as the Differential Absorption Lidar (DIAL) technique, where fast tuning within a wide spectral region is necessary. Tunable acousto-optical filters (TAOF), used recently in astrophysical observations to suppress the background radiation, can be employed with success in lidar sounding. They are attractive due to the possibility for fast spectral scanning with a narrow transmission band. The TAOF's advantages are fully evident in DIAL lidars where one must simultaneously receive signals at two laser frequencies.

Kolarov, G.↗

Spectrally resolved modulated infrared radiometry of photothermal, photocarrier, and photoluminescence response of CdSe crystals: Determination of optical, thermal, and electronic transport parameters

Spectrally resolved modulated infrared radiometry (SR-MIRR) with super-band gap photoexcitation is introduced as a self-consistent method for semiconductor characterization (CdSe crystals grown under different conditions). Starting from a theoretical model combining the contributions of the photothermal (PT) and photocarrier (PC) signal components, an expression is derived for the thermal-to-plasma wave transition frequency f{sub tc} which is found to be wavelength-independent. The deviation of the PC component from the model at high frequency is quantitatively explained by a quasi-continuous distribution of carrier recombination lifetimes. The integral, broad frequency band (0.1 Hz–1 MHz) MIRR measurements simultaneously yielded the thermal diffusivity a, the effective IR optical absorption coefficient β{sub eff}, and the bulk carrier lifetime τ{sub c}. Spectrally resolved frequency scans were conducted with interchangeable IR bandpass filters (2.2–11.3 μm) in front of the detector. The perfect spectral match of the PT and PC components is the direct experimental evidence of the key assumption in MIRR that de-exciting carriers are equivalent to blackbody (Planck) radiators. The exploitation of the β spectrum measured by MIRR allowed determining the background (equilibrium) free carrier concentration n{sub 0}. At the shortest wavelength (3.3 μm), the photoluminescence (PL) component supersedes the PC one and has distinct features. The average sample temperature influences the PC component but not the PT one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor® 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R^2) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify self-absorption effects. The microscopy analysis compares different filter loadings and shows that smaller particle sizes (under 10 micron) can readily be seen on the more lightly loaded filters. At higher loadings, however, the particle size is harder to differentiate. This study provides data on actual stack emission samples showing a range of mass loading conditions and visual evidence of particle size and distribution and also presents the difficulties in quantifying self-absorption effects using actual samples.

air sampling↗

A Photometric Technique for Determining Fluid Concentration using Consumer-Grade Hardware

In support of a separate study to produce an exponential concentration gradient in a magnetic fluid, a noninvasive technique for determining, species concentration from off-the-shelf hardware has been developed. The approach uses a backlighted fluid test cell photographed with a commercial digital camcorder. Because the light extinction coefficient is wavelength dependent, tests were conducted to determine the best filter color to use, although some guidance was also provided using an absorption spectrophotometer. With the appropriate filter in place, the provide attenuation of the light passing, through the test cell was captured by the camcorder. The digital image was analyzed for intensity using, software from Scion Image Corp. downloaded from the Internet. The analysis provides a two-dimensional array of concentration with an average error of 0.0095 ml/ml. This technique is superior to invasive techniques, which require extraction of a sample that disturbs the concentration distribution in the test cell. Refinements of this technique using a true monochromatic laser light Source are also discussed.

Leslie, F.↗

Reflectance spectroscopy of fresh whole leaves for the estimation of chemical concentration

Remotely sensed plant-canopy data in the visible and near-IR ranges are used to establish relations between the canopy reflectance and the chemical content of the leaves. The mathematical relation is generated by means of stepwise regression based on the derivative reflectance at certain wavelengths. Fourier filtering and sample control are used to minimize instrument noise and spectral overlap respectively, and absorption features are noted that correspond to sugar and protein. The coefficients of determination between estimated and measured concentrations are at least 0.82 for such substances as starch and chlorophyll. It is recommended in the analysis of remotly sensed canopy data that the chemicals with strong spectral overlaps with the chemical of interest be accounted for in order to estimate foliar chemical concentrations accurately.

Curran, Paul J.↗

A Detailed Characterization of the Saharan Dust Collected During the Fennec Campaign in 2011: In Situ Ground-Based and Laboratory Measurements

Millions of tons of mineral dust are lifted by the wind from arid surfaces and transported around the globe every year. The physical and chemical properties of the mineral dust are needed to better constrain remote sensing observations and are of fundamental importance for the understanding of dust atmospheric processes. Ground-based in situ measurements and in situ filter collection of Saharan dust were obtained during the Fennec campaign in the central Sahara in 2011. This paper presents results of the absorption and scattering coefficients, and hence single scattering albedo (SSA), of the Saharan dust measured in real time during the last period of the campaign and subsequent laboratory analysis of the dust samples collected in two supersites, SS1 and SS2, in Algeria and in Mauritania, respectively. The samples were taken to the laboratory, where their size and aspect ratio distributions, mean chemical composition, spectral mass absorption efficiency, and spectral imaginary refractive index were obtained from the ultraviolet (UV) to the near-infrared (NIR) wavelengths. At SS1 in Algeria, the time series of the scattering coefficients during the period of the campaign show dust events exceeding 3500 Mm (exp -1), and a relatively high mean SSA of 0.995 at 670 nm was observed at this site. The laboratory results show for the fine particle size distributions (particles diameter <5μm and mode diameter at2–3 μm) in both sites a spectral dependence of the imaginary part of the refractive index Im(m) with a bow-like shape, with increased absorption in UV as well as in the shortwave infrared. The same signature was not observed, however, in the mixed particle size distribution (particle diameter<10 μm and mode diameter at 4 μm) in Algeria. Im(m) was found to range from 0.011 to 0.001i for dust collected in Algeria and 0.008 to 0.002i for dust collected in Mauritania over the wavelength range of 350-2500 nm. Differences in the mean elemental composition of the dust collected in the supersites in Algeria and in Mauritania and between fine and mixed particle size distributions were observed from EDXRF measurements, although those differences cannot be used to explain the optical properties variability between the samples. Finally, particles with low-density typically larger than 10 μm in diameter were found in some of the samples collected at the supersite in Mauritania, but these low-density particles were not observed in Algeria.

Saharan dust measured in real time↗

A novel energy balance approach for a verifiable and accurate solution of radiation extinction in purely absorbing particle clouds

Here we consider the problem of radiation transport through purely absorbing particle clouds. The gold-standard solution of particle-resolved Monte Carlo ray-tracing method to this problem is computationally expensive and therefore solving the radiation transport equation (specifically, the Beer-Bouguer law (BB-law)) on a Eulerian mesh is often preferred. While the absorption coefficient in the real problem is infinite, the BB-law approximates it to be a finite number in the form of number density through a set of assumptions. For particle clouds that do not obey these assumptions, the BB-law predicts an incorrect exponential decay. Also, when the number density is computed using the nearest-neighbor approach, the BB-law solution diverges when the Eulerian mesh size becomes closer to or smaller than the particle size. This numerical divergence is due to the homogenization error. Although the filtering strategy for number density minimizes the homogenization error, it still converges to an incorrect exponential decay for particle clouds that break the BB-law constraints and the cost of the filtering is equivalent to that of the gold-standard solution. In this study, we develop a novel, highly accurate, verifiable and cost-effective solution to the radiation transport equation on a Eulerian domain using an energy balance approach where we derive an expression for the absorption coefficient as a function of particle and Eulerian mesh sizes. We apply our new method to Poisson and turbulent particle clouds that violate all the BB-law constraints and show that the solution is converging upon the mesh refinement, and eventually, we recover the same gold-standard solution for a much cheaper computational cost.

42 ENGINEERING↗

AMICE2 measurements of lab-generated and ambient aerosols at BNL from 2025-07-21 to 2025-08-22

From July 21 through August 22, 2025 the Absorption Measurement Inter-Comparison Experiment phase 2 (AMICE2) was conducted at Brookhaven National Laboratory. The experiment included concurrent operation of several filter-based instruments and in situ instruments sampling from a common sample line. The common sample line provided all instruments with either lab-generated aerosols composed of external mixtures of nigrosin, cabojet, and ammonium sulfate, or with ambient aerosol drawn through an external stack. This data set contains measurements from the CAPS PMssa instrument taken as a reference instrument at 532 nm and against which the effectiveness of the filter corrections may be assessed. It also contains attenuation coefficients from all filter-based instruments and filter transmittances in order to permit correction for filter loading, and the SSA and COA to permit corrections for aerosol darkness. Finally, two sets of multiplicative corrections are provided for the AE-33, TAP, and MA-350 instruments: the first one, Corr1, corrects for filter amplification factor and loading, the second one, Corr2, corrects for the aerosol darkness in terms of the natural log of COA.

Aerosol Extinction↗

IPN Absorption Coefficients

The dataset contains aerosol light absorption and scattering coefficients measured by three single-wavelength Integrated Photoacoustic Nephelometers (IPN). The absorption coefficients were measured at 405, 721, and 1047 nm, while the scattering coefficients were measured at 405 and 721 nm. The single scattering albedo (SSA) at 405 and 721 nm were also calculated from the IPN measurements. The three IPNs shared a common inlet without impactor/cyclone in July; in August, a PM2.5 cyclone inlet was installed to reduce measurement noise and improve data quality. The 721-nm IPN experienced laser shutdown issues, causing missing of a large fraction of the 721-nm measurements, especially in July. As described before, the 721-nm laser issue was less frequent in August after the cyclone installation, improving the data completeness and quality. The IPN raw data were noisy, making identifying patterns and trends difficult; therefore, the hourly average data are recommended over the raw data. The hourly average data were cross-checked with the filter-based TAP and PSAP measurements, which showed that their patterns, trends, and peaks matched. However, due to the differences in working mechanisms and principles of the filter-based and photoacoustic particle-phase instruments, the IPN measurements are lower than the filter-based measurements despite that they have consistent patterns, trends, and peaks.

54 ENVIRONMENTAL SCIENCES↗

Study of silicon strip waveguides with diffraction gratings and photonic crystals tuned to a wavelength of 1.5 µm

Single-mode submicrometer-thick strip waveguides on silicon-on-insulator substrates, fabricated by silicon-planar-technology methods are considered. To solve the problem of 1.5-µm wavelength radiation input-output and its frequency filtering, strip diffraction gratings and two-dimensional photonic crystals are integrated into waveguides. The reflection and transmission spectra of gratings and photonic crystals are calculated. The waveguide-mode-attenuation coefficient for a polycrystalline silicon waveguide is experimentally estimated.

36 MATERIALS SCIENCE↗

Design of Multifunctional Materials: Chalcogenides and Chalcopyrites

There is a strong need for developing multifunctional materials to reduce the cost of applied material without compromising the performance of the detectors, devices and sensors. The materials design, processing, growth and fabrication of bulk and nanocrystals and fabrication into devices and sensors involve huge cost and resources including a multidisciplinary team of experts. Because of this reason, prediction of multifunctionality of materials before design and development should be evaluated. Chalcogenides and chalcopyrites are a very exciting class of materials for developing multifunctionality. Materials such as Gallium selenide GaSe and zinc selenide ZnSe have been proven to be excellent examples. GaSe is a layered material and very difficult to grow in large crystal. However, it's ternary and quaternary analogs such as thallium gallium selenide TlGaSe2, thallium gallium selenide sulfide TlGaSe2-xSs, thallium arsenic selenide Tl3AsSe3, silver gallium selenide AgGaGe3Se8, AgGaGe5Se12 and several others have shown great promise for multifunctionality. Several of these materials have shown good efficiency for frequency conversion (nonlinear optical NLO), electro-optic modulation, and acousto-optic tunable filters and imagers suitable for the visible, near-infrared wavelength, mid wave infrared (MWIR), long wave infrared (LWIR) and even up to Tera hertz wavelength (THW) regions. In addition, this class of materials have demonstrated low absorption coefficients and power handling capability in the systems. Also, these crystals do not require post growth annealing, show very large transparency range and fabricability.

Singh, N. B.↗

The Mimas ghost revisited - An analysis of the electron flux and electron microsignatures observed in the vicinity of Mimas at Saturn

An analysis of the electron-absorption signature observed by the cosmic-ray system on Voyager 2 near the orbit of Mimas is presented. It is found that these observations cannot be explained as the absorption signature of Mimas. By combining Pioneer 11 and Voyager 2 measurements of the electron flux at Mimas's orbit (L = 3.1), an electron spectrum is found in which most of the flux above about 100 keV is concentrated near 1 to 3 MeV. This spectral form is qualitatively consistent with the bandpass filter model of Van Allen et al. (1980). The expected Mimas absorption signature is calculated from this spectrum neglecting radial diffusion. Since no Mimas absorption signature was observed in the inbound Voyager 2 data, a lower limit on the diffusion coefficient for MeV electrons at L = 3.1 of D greater than 10 to the -8th sq Saturn radii/sec is obtained. With a diffusion coefficient this large, both the Voyager 2 and the Pioneer 11 small-scale electron-absorption-signature observations in Mimas's orbit are enigmatic. Thus the mechanism for producing these signatures is referred to as the Mimas ghost. A cloud of material in orbit with Mimas may account for the observed electron signature if the cloud is at least 1-percent opaque to electrons across a region extending over a few hundred kilometers.

Chenette, D. L.↗

Transmittance and optical constants of Eu films from 8.3 to 1400 eV

The optical constants of Eu films were obtained in the 8.3-1400 eV range from transmittance measurements performed at room temperature. Thin films of Eu were deposited by evaporation in ultrahigh vacuum conditions and their transmittance was measured in situ. Eu films were deposited onto grids coated with a thin C support film. The refractive index n of Eu was calculated using the Kramers-Kronig analysis. Data were extrapolated both on the high- and low-energy sides by using experimental and calculated extinction coefficient values available in the literature. Eu, similar to other lanthanides, has a low-absorption band just below the O{sub 2,3} edge onset; the lowest absorption was measured at about 16.7 eV. Therefore, Eu is a promising material for filters and multilayer coatings in the energy range below the O{sub 2,3} edge in which materials typically have a strong absorption. The consistency of the composite optical constants was tested with the f and inertial sum rules and found to be good.

36 MATERIALS SCIENCE↗

Study of the loss of xenon scintillation in xenon-trimethylamine mixtures

This work investigates the capability of TMA ((CH 3 ) 3 N) molecules to shift the wavelength of Xe VUV emission (160-188 nm) to a longer, more manageable, wavelength (260-350 nm). Light emitted from a Xe lamp was passed through a gas chamber filled with Xe-TMA mixtures at 800 Torr and detected with a photomultiplier tube. Using bandpass filters in the proper transmission ranges, no reemitted light was observed experimentally. Considering the detection limit of the experimental system, if reemission by TMA molecules occurs, it is below 0.3% of the scintillation absorbed in the 160-188 nm range. An absorption coefficient value for xenon VUV light by TMA of 0.43 ± 0.03 cm -1 Torr -1 was also obtained. These results can be especially important for experiments considering TMA as a molecular additive to Xe in large volume optical time projection chambers.

36 MATERIALS SCIENCE↗

High-reflective multilayers as narrowband VUV filters

A novel coating has been developed for the 120-230 nm wavelength VUV region which yields significantly higher reflectivity over selectable bandwidths and can be used to fabricate high-performance narrowband reflection filters; the spectral properties of such filters are greatly enhanced through their use in tandem. The coating uses a combination of high and low refractive index dielectric pairs. The proper choice of high-low ratio reduces the effects of VUV absorption for high refractive index films whose extinction coefficient is much higher than for a low-index material.

Zukic, Muamer↗

Transmission Properties of Zitex in the Infrared to Submillimeter

The results of measurements of the refractive index and power absorption coefficient of Zitex at 290 K, 77 K, and 4 K in the spectral region from 1 to 1000 microns are presented. Zitex is a porous Teflon sheet with a filling factor of approximately 50%, and is manufactured in several varieties as a filter paper. Zitex is found to be an effective infrared radiation block, with thin (200 micrometer) sheets transmitting less than 1% in the 1-50 micrometer range while absorbing <10% at wavelengths longer than 200 micrometers. Some variation in the cutoff wavelength is seen, tending to be a shorter wavelength cutoff for a smaller pore size. Additionally, the thermal conductivity of Zitex at cryogenic temperatures has been measured, and is found to be roughly one-half that of bulk Teflon.

Benford, D. J.↗