Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Controlled Dy-doping to nickel-rich cathode materials in high temperature aerosol synthesis

Layered nickel-rich materials are promising next-generation cathode materials for lithium ion batteries due to their high capacity and low cost. However, the poor thermal stability and longtime cycling performance hinders the commercial applications of high nickel materials. Doping with heteroatoms has been an effective approach for improving electrochemical performance of cathode materials. Controlling doping concentration and geometrical distribution is desired for optimal electrochemical performance, but it is challenging in traditional co-precipitation methods. In this work, controlled dysprosium (Dy) doping to NCM811 was studied in an aerosol synthesis method by controlling the precursor concentrations and heating parameters. The obtained materials were characterized by SEM, XRD, and XPS, and their electrochemical properties and thermal stability were evaluated. By controlling the doping concentration (1.5%), Dy-doped NCM811 was improved simultaneously in long-term cycling and high-rate performance. Here, the thermal-chemical stability of the Dy-doped cathode materials was examined in a microflow reactor with a mass spectrometer. The results showed that Dy-doping shifted the O 2 onset temperature to a higher temperature and reduced O 2 release by 80%, thus dramatically increasing the thermal-chemical stability and improving the fire safety of cathode materials. Since high temperature aerosol synthesis is a low-cost and scalable method, the findings in this work have broad implications for commercial synthesis of novel materials with controlled doping modification to achieve high electrochemical performance and safety in lithium ion batteries.

25 ENERGY STORAGE↗

Numerical modeling of plasma assisted deflagration to detonation transition in a microscale channel

Here, this work numerically studies the plasma assisted deflagration to detonation transition (DDT) of H 2 /O 2 mixtures in a microscale channel with detailed chemistry and transport. The results show that the DDT onset time is non-monotonically dependent on the discharge pulse number. The DDT is accelerated with small pulse numbers, whereas retarded with large ones. Two different DDT regimes, respectively at a small and large plasma discharge number, via acoustic choking of the burned gas and plasma-enhanced reactivity gradient without acoustic choking, are observed. Without plasma discharge, pronounced pressure and temperature gradients in front of the flame are generated by acoustic compression after the choking of the burned gas, triggering DDT via autoignition. With small plasma pulse numbers, the plasma-generated species enhance the ignition kinetics and lead to an increased reactivity in the boundary layer. After the choking of the burned gas, the plasma-enhanced reactivity advances the sequence of autoignition near the wall, strengthens ignition-shock wave coupling, and accelerates DDT. However, with a large discharge pulse number, a direct autoignition initiating DDT can occur without the acoustic choking of the burned gas due to the strongly accelerated reactivity and elevated temperature. In this case, DDT onset is retarded because the elevated temperature increases sonic velocity and the increased reactivity accelerates fuel oxidation in front of the flame, decelerating the formation of a leading shock and subsequent pressure buildup ahead of the flame. The present modeling reveals that no matter with or without plasma discharge, DDT is initiated by autoignition in thermal, pressure, and reactivity gradient fields via the Zel'dovich gradient mechanism. The acoustic choking of the burned gas may not be the necessary condition of DDT with strong plasma-enhanced reactivity gradient. This work provides an answer to the experimentally observed non-monotonic DDT onset time by plasma, which provides guidance to control DDT in advanced detonation engines and fire safety of hydrogen-fueled catalytic reactors in microchannels by non-equilibrium plasma discharge.

33 ADVANCED PROPULSION SYSTEMS↗

Rate constants and third-body collision efficiencies for recombination of Na with OH and O2: Implications for flame inhibition by alkali salts

Flame inhibition by alkali metals has implications for solid fuel combustion, fire safety, and a number of industrial processes. While the mechanism of inhibition is fairly well understood, details related to thermodynamic properties and rate constants are still in question. In the present work, the recombination of Na with OH (R5) and O2 (R7), respectively, was characterized theoretically, and the implications for modeling laminar premixed hydrogen flames doped with sodium species were examined. Third-body collision efficiencies and low-pressure-limit rate constants were obtained using newly fitted ab initio-based potential energy surfaces, classical trajectories, and one-dimensional master equation calculations. The results are consistent with available experimental results and aid in the present modeling study by providing rate information for bath gases and conditions that remain unexplored experimentally. Chemical kinetic modeling of relative Na and absolute H and OH profiles in H2-fueled laminar, premixed flames doped with a sodium salt shows that the most important radical removal cycle is the sequence Na + OH (+M) → NaOH (+M) (R5), NaOH + H → Na + H2O (R12), even under oxidizing conditions. A secondary cycle, Na + O2 (+M) ⇄ NaO2 (+M) (R7), NaO2 + OH → NaOH + O2 (R14), is less important due to the low thermal stability of NaO2. In most flames, reaction R7 is partially equilibrated, and reaction R14 becomes rate-limiting for the second cycle. The flame analysis supports a lower value of k14 than indicated by recent work on KO2 + OH, but more work is required to confirm this.

Jasper, Ahren W.↗

Development and experimental evaluation of new building air leakage measurement methods: measurement of interior air leaks and comparison to conventional methods

Building air leaks (both through exterior and interior surfaces) can have a significant impact on energy consumption, indoor air quality, fire safety, and moisture accumulation affecting structural durability. Blower door testing has been used to measure leaks in buildings, but commonly used testing methods do not directly measure interior leaks. In this paper, new testing methods (guarded interior test and zonal multipoint pressure testing method) are presented that directly measure these interior leaks, utilizing common blower door equipment for both single and multi-point testing. Furthermore, these new methods are compared to conventional methods in terms of the information provided, limitations and time/effort needed. In addition, building leak measurement results are analyzed to reveal a) coupling between power law model values (exponent and coefficient) for an ensemble of buildings, b) the error in using single point testing when estimating low pressure leakage, and c) how building power law models vary from low to high pressure ranges.

99 GENERAL AND MISCELLANEOUS↗

NSRC makes vital vintage films accessible to today's weapons researchers

A few years ago, archivists at the Lab’s National Security Research Center (NSRC) rediscovered 65 special reels of nitrate motion picture film among the 20,000 film reels in the NSRC’s collections. Because nitrate film stock was discontinued in 1951, they realized that the films contained footage from the Lab’s earliest days of nuclear testing. However, nitrate film is highly toxic and flammable. Confirming this hunch would have to wait until the NSRC team devised a strategy for safely preserving and digitizing the reels. Now, after many months of planning and collaboration with LANL fire safety and industrial hygiene teams, the reels – which include footage from Operation Sandstone, Operation Ivy, and the Trinity test – have been digitized by the NSRC archivist team and are accessible to today’s researchers.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Nanosecond Laser Drying in Wafer Foundries for Significant Energy Efficiency Improvement

Surface drying is a critical process in microelectronics wafer fabrication. In order to reduce and eliminate watermarks, many surface drying processes have been studied and used. Most of the wafer foundries currently use drying processes based on Isopropyl Alcohol (IPA), which causes serious safety (fire), health, environmental, and energy efficiency issues. The long-term goal of this project is to develop a fast, effective, chemical-free, and extremely energy efficient wafer drying technology that employs nanosecond laser-induced sub-surface evaporation and explosion. The objectives of this project are to 1) experimentally develop and verify the laser surface drying method, explore and identify how and to what extent various physical parameters influence the drying efficiency and effectiveness; and 2) understand and optimize the underlying thermodynamics in the proposed laser surface drying, including micro/nanoscale sub-surface superheating, evaporation, explosion, and photo/thermochemical bond breaking via atomistic modeling and experimental characterization. Toward these objectives, five tasks have been accomplished successfully, including 1) develop in-lab laser surface drying setup and study the effect of varied laser parameters, 2) use multiscale hybrid-modeling to study and understand the physics of water behavior during drying toward process optimization, 3) investigate the effect of drying conditions on the drying effectiveness, 4) develop a large-scale laser drying scanning system with automatic scanning, and 5) conduct large-scale simulation to study the effect of dopant level and develop strategies for system development toward industry deployment.

42 ENGINEERING↗

Roadmap to Iodine and Mercury Abatement Materials Selection in Nuclear Waste Processing Off-Gas Streams

This work provides a guide for candidate mercury (Hg) and iodine-129 (129I) abatement material identification, screening, evaluation, technical gap identification, and bench-scale testing prioritization while also conceptualizing a materials deployment roadmap for implementation of new materials in the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility at Hanford in Richland, Washington, and elsewhere in the U.S. Department of Energy (DOE) complex for similar applications. The study was prompted by the need to replace the Kombisorb BAT-37 due to uncertainties in Hg and 129I capture performance and future availability for use in the WTP LAW Facility secondary off-gas system, specifically the Carbon Adsorber units. However, replacement of this material could also mitigate two other issues with Kombisorb BAT-37 (and its successor BAT II 37): (1) fire safety risk due to exothermic heat generated by adsorption reactions between the carbon material and Hg and (2) the risk of low retention of 129I in glass and subsequent downstream impacts on secondary liquid waste treatment at the Effluent Treatment Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Development of a 95-Year Solar Dataset for Resource Adequacy Studies

Long-term high-resolution solar data provides enhanced understanding of variability of solar generation and enhances our ability to develop strategies for a resilient and reliable electric grid under high deployment of solar energy. Therefore, it is important to develop long-term synthetic datasets that can provide multiple occurrences of various severe weather scenarios that are expected to test the limits of resource adequacy under scenarios contain various energy generation sources. Examples of such scenarios could be long periods of high temperatures when demand for electricity is high or periods where high winds could lead to a shut-down of transmission lines for long periods of time to ensure fire safety. NREL has developed the first version of such a dataset covering a 95-year period covering 2006-2100 at a 4km hourly resolution. This dataset contains all variables necessary to calculate solar generation. During development of this dataset, we focused on creating unbiased, high-resolution solar irradiance through statistical downscaling methods, using Regional Climate Model (RCM) simulations from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) as input. The National Solar Radiation Database (NSRDB) containing over 25 years of observations was used to calibrate the statistical downscaling models. This presentation will outline the primary steps in developing this dataset, including (1) regridding RCM data to a common grid at 20-km resolution, (2) correcting RCM biases with NSRDB, (3) applying temporal and spatial downscaling methods to generate high-resolution (4-km, hourly) solar and ancillary data. Additionally, we will present an evaluation of the downscaled data against the NSRDB across various zones in the CONUS. Lastly, we will present a user guide for accessing the datasets.

14 SOLAR ENERGY↗

Electric Vehicle Fire Primer for Fleet Managers

The U.S. Department of Energy's Vehicle Technologies Office provides project assistance through Clean Cities, technical expertise, and funding to help stake-holders implement alternative fuels and electric vehicles (EVs). Fleet managers considering EVs can learn about the potential for EV fires and measures to help reduce fire risk.

ADVANCED PROPULSION SYSTEMS↗

Pulse Shape Discrimination in JSNS 2

JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\overline{ν}$ μ → $\overline{ν}$ e appearance oscillations using neutrinos from muon decay-at-rest. For this search, rejecting cosmic-ray-induced neutron events by Pulse Shape Discrimination (PSD) is essential because the JSNS2 detector is located above ground, on the third floor of the building. We have achieved 94.95% ± 0.15% rejection of neutron events while keeping 92.82% ± 1.77% of signal, electron-like events using a data-driven likelihood method. This article will report the PSD technique using the full fiducial volume of the JSNS2 detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultralight and fire-extinguishing current collectors for high-energy and high-safety lithium-ion batteries

Inactive components and safety hazards are two critical challenges in realizing high-energy lithium-ion batteries. Metal foil current collectors with high density are typically an integrated part of lithium-ion batteries yet deliver no capacity. Meanwhile, high-energy batteries can entail increased fire safety issues. Here we report a composite current collector design that simultaneously minimizes the ‘dead weight’ within the cell and improves fire safety. An ultralight polyimide-based current collector (9 μm thick, specific mass 1.54 mg cm-2) is prepared by sandwiching a polyimide embedded with triphenyl phosphate flame retardant between two superthin Cu layers (~500 nm). Compared to lithium-ion batteries assembled with the thinnest commercial metal foil current collectors (~6 µm), batteries equipped with our composite current collectors can realize a 16-26% improvement in specific energy and rapidly self-extinguish fires under extreme conditions such as short circuits and thermal runaway.

25 ENERGY STORAGE↗

Power System Wildfire Risks and Potential Solutions: A Literature Review & Proposed Metric

Several fire risk evaluation, fire tracking, and fire response resources are available. The risk metrics and fire response programs are sometimes modified to include a power system context. The risk metrics often evaluate the risk of fires causing power system faults or outages, especially on transmission systems. The response programs are modified to ensure the safety of power system equipment and first responders as well as to coordinate power system outages to both ensure safety during an active fire and prevent fire ignition during high risk periods. Although some aspects of wildfire responses have been adapted to include power system concerns, adaptations to power system operations and maintenance to include wildfire risks and responses are still nascent. In particular, a risk metric that evaluates the potential for power system components to ignite wildfires is needed to help guide power system upgrade efforts and power system fire safety measures. This document serves as a brief literature review of wildfire risk metrics and response programs and how they relate to power systems. It also includes a proposed risk metric and structure for describing the risk of a power system component igniting a fire.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pressurization Analysis for Heating of a Screw Top Utility Can Loaded With Plutonium Oxide Powder by a 1273 K Fire

The documented safety analysis for the Savannah River National Laboratory (SRNL) evaluates the consequences of a postulated 1273 K fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage containers. The oxide storage configuration selected for analysis is can/bag/can, comprised of oxide powder inside an 8.38 × 10 -6 m 3 stainless steel B vial inside 0.006 kg of polyethylene bagging inside a one-quart screw top utility can of the type commonly used to package solvents or rubber cements. To enable evaluation of the dose consequences, temperature and pressure transients have been calculated for exposure of a typical set of storage containers to the fire. The pressurization analysis credits venting to and from the B vial but does not credit venting or leakage from the can. Due to the low rate of venting from the B vial into the can gas space, the can pressure is nearly independent of the B vial pressure. Calculated maximum pressures are compared to the utility can burst pressure. In lieu of a structural analysis of the utility cans, burst pressures and leakage rates were measured using compressed nitrogen gas. The measured gauge burst pressure was 0.250 ± 0.043 MPa. The measured burst pressures are lower than the calculated maximum pressure due to fire exposure, indicating that the utility cans could burst during exposure to a 1273 K fire.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Methods and recommendations for large-scale deflagration testing of battery energy storage system enclosures

UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.

Gaudet, Benjamin [UL Solutions] (ORCID:00090006419↗

Defining the State of Safety (SOS) for Lithium-Ion Batteries in EVs: A Discussion

The demand for lithium-ion batteries (LIBs) is skyrocketing, driven by the rapid growth of electric vehicles (EVs) and grid energy storage. However, current LIBs rely on flammable electrolytes, making them susceptible to thermal runaway and fires. Despite ongoing research and development efforts to enhance safety, fire incidents in EVs and energy storage systems persist. As LIB deployment increases, so too does the risk of fires. Therefore, it's crucial to define a "State of Safety" for LIBs - encompassing both operational safety and post-incident safety, such as after a car accident. This concept can help stakeholder and first responders to effectively manage LIB fire risks.

25 ENERGY STORAGE↗

Acoustics Examination of Kappa West Firing ARMAG for Personnel Occupancy

In April of 2023, LANL conducted a series of explosive tests at the Kappa West firing mound at BEEF, NNSS, to examine noise levels within the diagnostics ARMAG next to the firing mound. The intent was to establish an explosive mass that could be detonated on the mound without generating blast noise inside the ARMAG which would be unsafe for personnel. The blast noise threshold for personnel safety during intentional firing operations is 140 dB. Based on data collected during prior experiments, it was anticipated that the noise levels inside the ARMAG would be 20-30 dB lower than noise levels outside the ARMAG. However, data from prior experiments were collected from charges that were not consistent geometries and test layouts, so it was unknown what quantity of explosive would generate the threshold noise level. A prediction was made using the BEC-O standard blast calculator from the DDESB, from which it was estimated that a single, consolidated 60-pound charge at 180 feet would generate blast noise levels of about 170 dB, with noise levels falling to a predicted 166 dB at 250 feet.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Radiation Effects on Line Heat Detection Cable AP Hot Cells Fire Detection at Brookhaven National Laboratory

Hot cells are used to safely shield workers from high radiation environments while allowing a process to take place within the cell's shielded enclosure, often with the assistance of remote manipulators. The interior of a cell may not be accessible by personnel for years at a time, either due to the lingering radiation environment or due to the constant use of these specialized pieces of equipment. High radiation levels are known to cause undesirable effects and changes to different materials in varying degrees. Selecting equipment for a radiation environment requires an evaluation of materials used (preferably completed assembles), to ensure all interactions of materials are known and ensure that the equipment will have a high degree of reliability and functionality over the intended life of the facility. Hot cells contain systems to support the primary purpose of the enclosure. Fire detection is one such support system. Safety of hot cell operations often establish limits on the amounts of combustibles with the cells, but the presence of some combustible materials is unavoidable. Fire detection is provided to quickly detect a fire and summon manual intervention before damage is too great. Detection may also be used to initiate fire suppression systems. As a safety system, fire detection needs to remain functional to protect the facility throughout the facility's life. Equally important is that the false alarms from the fire detection are minimized to retain confidence in the alarm system and avoid unnecessary interruptions in the hot cell operations. There are many types of fire detection available with various pros and cons. Not all types of fire detection are suited for hot cell application.

36 MATERIALS SCIENCE↗