Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measurement and Modeling of Blocking Contacts for Cadmium Telluride Gamma Ray Detectors

Gamma ray detectors are important in national security applications, medicine, and astronomy. Semiconductor materials with high density and atomic number, such as Cadmium Telluride (CdTe), offer a small device footprint, but their performance is limited by noise at room temperature; however, improved device design can decrease detector noise by reducing leakage current. This thesis characterizes and models two unique Schottky devices: one with an argon ion sputter etch before Schottky contact deposition and one without. Analysis of current versus voltage characteristics shows that thermionic emission alone does not describe these devices. This analysis points to reverse bias generation current or leakage through an inhomogeneous barrier. Modeling the devices in reverse bias with thermionic field emission and a leaky Schottky barrier yields good agreement with measurements. Also numerical modeling with a finite-element physics-based simulator suggests that reverse bias current is a combination of thermionic emission and generation. This thesis proposes further experiments to determine the correct model for reverse bias conduction. Understanding conduction mechanisms in these devices will help develop more reproducible contacts, reduce leakage current, and ultimately improve detector performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Methodology and Determination of Field of View of Neutron and Gamma Detectors in the Atucha Spent Fuel Storage Pool

In this paper we seek to create a model by determining the field of view (FOV) of a detector (i.e. which assemblies contribute to the detector response) in the Atucha-I spent fuel pool. The FOV is determined by solving the adjoint transport equation using the 3-D, parallel PENTRAN (Parallel Environment Neutral-particle TRANsport) Sn code, with the detector cross section as the adjoint source. If this adjoint function is coupled with the source spectrum, then the contribution to the detector from each assembly can be determined. First, the reactor criticality was modeled using the MCNP5 (Monte Carlo N-Particle) Monte Carlo code in order to determine the power distribution in each assembly. Using the power distribution data, the assemblies were divided and homogenized into 8 axial and 3 radial zones for burnup analysis. Depletion calculations were performed for each zone using the ORIGEN-ARP (Automatic Rapid Processing) utility from the SCALE 5.1 (Standardized Computer Analyses for Licensing Evaluation) code package. Spent fuel pool and detector were modeled in 2-D in PENTRAN as the detector plus 3 fuel assemblies along both x and y axes. Using the resulting adjoint function combined with the source spectrum, they have determined the FOVs of the fission chamber neutron detector that was used at Atucha, and concluded that 2 assemblies along x and y axes are needed for both cases (i.e. the 4 adjacent assemblies plus the next surrounding 12). For the neutron detector, 88% of the response comes from the nearest 4 assemblies, with 99% from the nearest 16. Results for a uniformly sensitive gamma detector indicate that 2 assemblies in both directions are also needed, with 89% of the response coming from the adjacent assemblies. A Monte Carlo calculation using MCNP was performed to benchmark the neutron result, giving a similar result (87% MCNP vs. 88% PENTRAN). Based on these studies, we have developed a database of FOVs as a function of burnup and decay conditions for different detector types, and a methodology/algorithm which uses this database to analyze the response of a detector placed in a spent fuel pool with the aim of detecting gross defects.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monte Carlo Simulations of Ultra-High Energy Resolution Gamma Detectors for Nuclear Safeguards

Ultra-high energy resolution superconducting gamma-ray detectors can improve the accuracy of non-destructive analysis for unknown radioactive materials. These detectors offer an order of magnitude improvement in resolution over conventional high purity germanium detectors. The increase in resolution reduces errors from line overlap and allows for the identification of weaker gamma-rays by increasing the magnitude of the peaks above the background. In order to optimize the detector geometry and to understand the spectral response function Geant4, a Monte Carlo simulation package coded in C++, was used to model the detectors. Using a 1 mm{sup 3} Sn absorber and a monochromatic gamma source, different absorber geometries were tested. The simulation was expanded to include the Cu block behind the absorber and four layers of shielding required for detector operation at 0.1 K. The energy spectrum was modeled for an Am-241 and a Cs-137 source, including scattering events in the shielding, and the results were compared to experimental data. For both sources the main spectral features such as the photopeak, the Compton continuum, the escape x-rays and the backscatter peak were identified. Finally, the low energy response of a Pu-239 source was modeled to assess the feasibility of Pu-239 detection in spent fuel. This modeling of superconducting detectors can serve as a guide to optimize the configuration in future spectrometer designs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma-ray detectors based on magnetic microcalorimeters (MMCs) for accurate measurements of nuclear decay data and NDA of nuclear materials. For highest energy resolution, we are introducing erbium-doped silver (Ag:Er) as a novel sensor material and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. For highest energy resolution we will operate the MMC detector arrays in a dilution refrigerator with a base temperature <10 mK. The detector performance and utility will be demonstrated with radioactive sources of interest to the safeguards community. In FY16 and FY17, we had purchased a liquid-cryogen-free dilution refrigerator and installed 16 SQUID preamplifiers and writing for MMC detector operation at ~10 mK. We have also developed the process to fabricate the first Ag:Er-based MMCs, built prototype detector arrays and tested them with different radioactive sources. We have also shown that our MMC detectors can achieve the LCP goal of an energy resolution below 50 eV as needed to resolve most closelyspaced lines of interest for NDA. The goals for FY18 were then 1) to optimize the MMC design based on the measured detector characteristics and to increase the array size to 32-pixels for increased sensitivity, and 2) to demonstrate the utility of MMC gamma-ray detectors in applications relevant in nuclear safeguards.

42 ENGINEERING↗

Magnetic Microcalorimeter Gamma Detectors for High-Precision Non-Destructive Analysis, FY14 Extended Annual Report

Cryogenic gamma (γ) detectors with operating temperatures of ~0.1 K or below offer 10× better energy resolution than conventional high-purity germanium detectors that are currently used for non-destructive analysis (NDA) of nuclear materials. This can greatly increase the accuracy of NDA, especially at low-energies where gamma rays often have similar energies and cannot be resolved by Ge detectors. We are developing cryogenic γ–detectors based on metallic magnetic calorimeters (MMCs), which have the potential of higher resolution, faster count rates and better linearity than other cryogenic detector technologies. High linearity is essential to add spectra from different pixels in detector arrays that are needed for high sensitivity. Here we discuss the fabrication of a new generation of MMC γ–detectors in FY2014, and the resulting improvements in energy resolution and linearity of the new design. As an example of the type of NDA that cryogenic detectors enable, we demonstrate the direct detection of Pu-242 emissions with our MMC γ–detectors in the presence of Pu-240, and show that a quantitative NDA analysis agrees with the mass spectrometry

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma Detector Response and Analysis Software - Detector Response Function

GADRAS-DRF uses a Detector Response Function (DRF) to compute the response of gamma-ray detectors incident radiation. The application includes provision for plotting measured and computed spectra and for characterizing detector response parameters based on measurements of a series of calibration sources (e.g., Ba-133, Cs-137, Co-60, and Th-228). An application program interface enables other programs to access the dynamic-link library that is used to compute spectra.

Source record↗

Conceptual design of a hybrid neutron-gamma detector for study of β-delayed neutrons at the RIB facility of RIKEN

Here, the conceptual design of the BRIKEN neutron detector at the radioactive ion beam factory (RIBF) of the RIKEN Nishina Center is reported. The BRIKEN setup is a complex system aimed at detecting heavy-ion implants, β particles, γ rays and β-delayed neutrons. The whole setup includes the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and up to 166 3 He-filled counters embedded in a high-density polyethylene moderator. The design is quite complex due to the large number and different types of 3 He-tubes involved and the additional constraints introduced by the ancillary detectors for charged particles and γ rays. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3 He-counter array, aiming for the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected detector parameters of merit, namely, the average neutron detection efficiency and the efficiency flatness as a function of a reduced number of geometric variables. The response of the neutron detector is obtained from a systematic Monte Carlo simulation implemented in GEANT4. The robustness of the algorithm allowed us to design a versatile detection system, which operated in hybrid mode includes the full neutron counter and two clover detectors for high-precision gamma spectroscopy. In addition, the system can be reconfigured into a compact mode by removing the clover detectors and re-arranging the 3 He tubes in order to maximize the neutron detection performance. Both operation modes shows a rather flat and high average efficiency. In summary, we have designed a system which shows an average efficiency for hybrid mode ( 3 He tubes + clovers) of 68.6% and 64% for neutron energies up to 1 and 5 MeV, respectively. For compact mode (only 3 He tubes), the average efficiency is 75.7% and 71% for neutron energies up to 1 and 5 MeV, respectively. The performance of the BRIKEN detection system has been also quantified by means of Monte Carlo simulations with different neutron energy distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beowulf - Beta-Gamma Detector Calibration Graphical User Interface

Pacific Northwest National Laboratory (PNNL) has demonstrated significant advancement in using beta-gamma coincidence detectors to detect a wide range of radioxenon isotopes. To obtain accurate activities with the detector it must be properly calibrated by measuring a series of calibration gas samples. The data is analyzed to create the calibration block used in the International Monitoring System file format. Doing the calibration manually has proven to be tedious and prone to errors, requiring a high degree of expertise. The Beowulf graphical user interface (GUI) is a software application that encompasses several components of the calibration task and generates a calibration block, as well as, a detailed report describing the specific calibration process used. This additional document can be used as a Quality assurance certificate to assist in auditing the calibration. This paper consists of two sections. Section 1 will describe the capabilities of Beowulf and section 2 will be a representative report generated or the 137Cs calibration and quality assurance source.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Using a Borated Panel to Form a Dual Neutron-Gamma Detector

A borated polyethylene plane placed between a neutron source and a gamma spectrometer is used to form a dual neutron-gamma detection system. The polyethylene thermalizes the source neutrons so that they are captured by {sup 10}B to produce a flux of 478 keV gamma-rays that radiate from the plane. This results in a buildup of count rate in the detector over that from a disk of the same diameter as the detector crystal (same thickness as the panel). Radiation portal systems are a potential application of this technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exploration of GaTe for Gamma Detectors

The layered III-VI semiconductor Gallium Telluride has potential for room temperature gamma ray spectroscopy applications due to its band gap of 1.67 eV, and average atomic number of 45:31 (Ga) and 52 (Te). The physical properties of GaTe are highly anisotropic due to covalent bonding within the layer and van der Waals bonding between layers. This work reports the results of surface and bulk processing, surface characterization, and electrical characterization of diodes formed on both the laminar and non-laminar GaTe surfaces. Alpha detection measurements were also performed.

36 MATERIALS SCIENCE↗

Root cause analysis and solutions for plastic gamma detector degradation in challenging environments—An overview

Polyvinyl toluene (PVT) plastic is often used to make gamma ray sensitive scintillators and is used in many important applications. For example, PVT is used to scan recycled steel going into a plant to be processed. It is also used in personnel portals to scan employees, and is used at the borders of many countries to scan cargo and cars passing through. In recent years, it was discovered that PVT can become degraded when it absorbs water and then is subjected to daily temperature swings, as is evidence by a reduction in scintillation light. Water absorption by PVT was notionally associated with temporary fogging (i.e., a rapid decrease in opacity which was reversible over time) and permanent fogging (i.e., permanent crack-like defects) and was for some time suspected to be the leading cause of the fogging due to circumstantial evidence. However, definitive proof was not established and in particular the specific mechanisms by which water entered the plastic and ultimately created temporary and permanent point-like defects was not fully understood. This paper is an overview of an effort initiated to reveal the fundamental root cause and also the dynamics of the fogging and degradation processes. This understanding is important not only to solve degradation problems for PVT in fielded systems, but also (1) to provide direction for future procurements for new equipment, and (2) to provide direction for future R&D efforts into advanced plastics with enhanced spectroscopic capabilities or dual particle gamma/neutron capabilities. Unexpected outcomes of this investigation included (1) the capability to predict the onset of fogging based on models using weather data alone, and (2) new modified formulations of PVT and PS which are fog-resistant. This paper provides an overview of the water uptake and associated mechanisms for various compositions, characterization of resulting temporary and permanent defects, predictive modeling of fogging, and possible solutions including encapsulation, heaters and new formulations. While this paper is an overview of the root cause analysis and solution, five accompanying papers (Lance et al., 2018, Myllenbeck and Feng, 2018, Payne et al., 2018, Zaitseva et al. 2018, Kouzes et al., 2018) from the same conference (SORMA 2018) delve further into the details and also expand upon the scope of what will be reported herein.

36 MATERIALS SCIENCE↗

Neutron Detector Gamma Insensitivity Criteria

The shortage of 3He has triggered the search for an effective alternative neutron detection technology for radiation portal monitor applications. Any new detection technology must satisfy two basic criteria: 1) it must meet the neutron detection efficiency requirement, and 2) it must be insensitive to gamma ray interference at a prescribed level, while still meeting the neutron detection requirement. It is the purpose of this document to define this latter criterion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel, Fast Readout, Gamma Detector System for Nuclear Fingerprinting - 18083

Decommissioning or cleanup of a nuclear facility or after a nuclear accident requires detailed knowledge of the type, distribution and amount of nuclear isotopes. Gamma spectroscopy is a technique that can provide this information in situ, using the energy deposited by incident photons into the spectrometer. However, the high precision needed limits the speed of measurement. In this work, we present a novel technique to achieve fast, precise measurements, employing a multi-detector system with a fast readout which is suitable for high radiation environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A novel background reduction strategy for high level triggers and processing in gamma-ray Cherenkov detectors

Gamma ray astronomy is now at the leading edge for studies related both to fundamental physics and astrophysics. The sensitivity of gamma detectors is limited by the huge amount of background, constituted by hadronic cosmic rays (typically two to three orders of magnitude more than the signal) and by the accidental background in the detectors. By using the information on the temporal evolution of the Cherenkov light, the background can be reduced. We will present here the results obtained within the MAGIC experiment using a new technique for the reduction of the background. Particle showers produced by gamma rays show a different temporal distribution with respect to showers produced by hadrons; the background due to accidental counts shows no dependence on time. Such novel strategy can increase the sensitivity of present instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma Detector Response/Soil Concentration Correlation Study at the AAR Manufacturing, Inc. Site, Livonia, Michigan

At the NRC's request, ORAU conducted surveys of the AAR Manufacturing site during the period of September 25 through September 27, 2012. The survey activities included walkover surveys and sampling activities. Once the survey team was onsite, the NRC personnel decided to forgo survey activities in the New Addition and the pickling area. Areas of the planned study boundary were inaccessible due to overgrowth/large pieces of concrete covering the soil surface; therefore, the study boundary was redefined. Gamma walkover scans of the site boundary and front yard identified multiple areas of elevated gamma radiation. As a result, two judgmental samples were collected. Sample results were above thorium background levels The answer to the PSQ relating to the relationship between thorium concentration in soil and NaI instrument response is Yes. NaI instrument response can be used as a predictor of Th-232 concentration in the 0 to 1 m layer. An R2 value of 0.79 was determined for the surface soil relationship, thus satisfying the DQOs. Moreover, the regression was cross-checked by comparing the predicted Th-232 soil core concentration to the average Th-232 concentration (Section 5.3.2). Based on the cross-check, the regression equation provides a reasonable estimate for the Th-232 concentration at the judgmental locations. Consideration must be given when applying this equation to other soil areas of the site. If the contamination was heterogeneously distributed, and not distributed in a discrete layer as it was in the study area, then using the regression equation to predict Th-232 concentration would not be applicable.

54 ENVIRONMENTAL SCIENCES↗

Xenon Gamma Detector Project Support

This project provided funding of $48,500 for part of one year to support the development of compressed xenon spectrometers at BNL. This report describes upgrades that were made to the existing detector system electronics during that period, as well as subsequent testing with check sources and Special Nuclear Materials. Previous testing of the equipment extended only up to the energy of 1.3 MeV, and did not include a spectrum of Pu-239. The new electronics allowed one-button activation of the high voltage ramp that was previously controlled by manual adjustments. Mechanical relays of the charging circuit were replaced by a tera-ohm resistor chain and an optical switch. The preamplifier and shaping amplifier were replaced by more modern custom designs. We found that the xenon purity had not been degraded since the chamber was filled 10 years earlier. The resulting spectra showed significantly better resolution than sodium iodide spectra, and could be analyzed quite effectively by methods using peak area templates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗