Search NASA⌕ Search

SEARCH · Search NASA

Results for “Godiva-IV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

29 records · Page 2

PNNL Measurement Results for the 2018 FlatTop Criticality Nuclear Accident Dosimetry Exercise at the Nevada National Security Site (IER-253)

The Pacific Northwest National Laboratory (PNNL) participated in the FlatTop exercise IER-253 at the National Nuclear Security Site (NNSS) during the week of May 21, 2018. This report summarizes the measurements of the personal nuclear accident dosimeters (PNAD). Additionally, portable survey instrument readings and measurements of the simulated biological samples are included. The FlatTop exercise (IER-253) tested only PNADs and did not include fixed nuclear accident dosimeters (FNAD). Previous PNAD results obtained in 2016 at the Godiva-IV exercise IER-148 were summarized in PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Site IER-148 (PNNL-26497). The results clearly indicated that the previous dose conversions were a historical legacy of the Hanford Site and corresponded closer to kerma dose (or first collision dose, and not to Hp(10) dose). The technical basis for PNAD dose was based on the Godiva-IV exercise and documented in A New Dose Calculation Methodology for New PNAD and FNAD Designs at PNNL (PNNL-27023). The configuration of the PNAD was described in these two documents. The FlatTop exercise was the first time PNNL tested this new dose calculation methodology. Results were generally favorable with some results conservatively over reported that fell above the performance criteria. The reported gamma dose results fell non-conservatively low because only the default parameters obtained from the Godiva-IV exercise were used, and because the OSL gamma dosimeter has an energy dependency. The results from the simulated biological samples were also favorable, and in several cases conservatively over reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Review of Nuclear Reactor Transients

This paper explores the nuclear yield that is produced during nuclear transients in small reactors. Nuclear reactor transients can have a wide range of effects such as the reproducible power excursions as found in Godiva-IV to full reactor destruction as planned for in the Kiwi-TNT test. Criticality accidents are also included in this study as in essence a small nuclear reactor has been inadvertently created. The motivation for this paper is to educate the audience as to the likely fission energy release for a typical transient in a small nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NCERC Capabilities [Slides]

NCERC is our nation’s only generalpurpose critical experiments facility and is one of only a few that remain operational throughout the world. The mission of the National Criticality Experiments Research Center (NCERC) is to conduct experiments and training with critical assemblies and fissionable material at or near criticality in order to explore reactivity phenomena, and to operate the assemblies in the regions from subcritical through delayed critical. One critical assembly, Godiva-IV, is designed to operate above prompt critical.

61 RADIATION PROTECTION AND DOSIMETRY↗

IER 555: Godiva Benchmark Update CED-2 (Final Design Report)

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluation of the Godiva IV critical assembly, HEU-MET-FAST-086: GODIVA-IV DELAYED-CRITICAL EXPERIMENTS (HMF-086), was completed by Russ Mosteller. Five critical experiment configurations performed at the Los Alamos National Laboratory (LANL) Technical Area (TA)-18 were evaluated as acceptable benchmark cases. The five cases consist of four delayed critical configurations which differ in control rod positions and one prompt critical configuration. All cases calculated a lower $k_{eff}$ than measured by experiment. This data is referred to as the TA-18 Godiva IV benchmark in this report. In 2005, Godiva IV was disassembled for relocation to the Nevada Test Site (NTS), now Nevada National Security Site (NNSS), at the National Criticality Experiments Research Center (NCERC). Following the disassembly and subsequent reassembly and startup of Godiva IV at NCERC, additional information about the Godiva IV components was obtained. An errata note was added to the HMF-086 evaluation in the ICSBEP handbook to provide this new information until a revision to the benchmark evaluation could be performed. In addition to those corrections, there are differences between the Godiva IV assembly at TA-18 and the Godiva IV assembly at NCERC. These differences include both assembly-specific differences (differences in the safety block gap, differences in the control rod positions, a new NCERC Top Hat and contamination shield) as well as environmental differences, such as the size and shape of the experimental building where the assembly is located. An additional model with similar cases, referred to as the NCERC Godiva IV benchmark in this report, will be added to the revised HMF-086 to capture these additional differences. This will provide the best benchmark model of Godiva for use by those performing experiments at NCERC. The IER 555 CED-2 report documents the information that will be updated in the HMF-086 revision, both the corrections to the TA-18 Godiva IV benchmark and the subsequent changes to create a NCERC Godiva IV benchmark. It describes the measurements that will be performed for cases similar to those performed at TA-18. It also describes measurements that will be included in the evaluation as additional data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hands-On Experimental Training [Slides]

Training provided includes: Nuclear Criticality Safety Fundamentals, Sub-Critical "Hands On" Demonstration, Hand-Stacking and Remote Approach to Critical Using the Planet Assembly, Flattop Free-Run Demonstration, and Godiva-IV Critical Assembly Demonstration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Godiva IV Simulated Radiation Field Characterization and Variance Reduction

Godiva IV is a system comprised of highly enriched uranium alloyed with molybdenum in the form of fuel plate rings. The reactor, along with its predecessors, was designed with the unique ability to satisfy interests in the super-prompt-critical reactor operation space. Originally, the reactor was part of the Los Alamos Critical Experiments Facility (LACEF) at Technical Area-18 (TA-18). The radiation field around Godiva at this facility was well characterized and understood. As a fast neutron system, the neutron spectrum in and around Godiva was close to a Watt Fission spectrum. The Kiva where Godiva IV was located at LACEF was made of thin, sheet metal walls which did not contribute significantly to the neutron spectrum. Following the transition of LACEF to the National Critical Experiments and Research Center (NCERC) in Nevada, Godiva-IV was moved from TA-18 to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). Part of this move brought renewed interest in radiation field characterization. The new facility introduced significant changes to the environment surrounding Godiva, and preliminary foil irradiation results suggested that the room contribution to the neutron spectrum was significant. Unlike at TA-18, a large thermal neutron signature was added to the fast spectrum from Godiva due to significant room return. A primary goal due to the additional complexity that the room return adds to the Godiva IV radiation emission spectrum was the development of an efficient Monte Carlo N-Particle (MCNP) calculation capable of characterizing the neutron spectrum anywhere in the room around Godiva. A campaign of activation foil irradiations and analysis were completed to support the validation of the MCNP model. The modeling of these foils in MCNP can be easily done with a standard volumetric neutron flux tally. However, given the multitude of locations and reaction rates to be modeled, further steps must be taken to increase the efficiency of these calculations in MCNP. During this study, a benchmark model currently under development for Godiva IV was used. A qualitative assessment of the thermal neutron contributors was performed using spatial neutron distribution plots. Additional detail was added to the model based on the qualitative results showing the thermal spectrum’s large sensitivity to hydrogenous material. Neutron energy spectra was evaluated at discrete locations in the room around Godiva to quantify the relative contribution of various components. It was discovered that the concrete walls are the largest contributor to the thermal signature, with minor contributions from plastic components surrounding Godiva. Following these results, two different variance reduction techniques were implemented to improve the problem efficiency in these calculations. In the first approach, an F5 point detector tally was implemented in the standard Godiva IV criticality problem. The second approach involved a weight-window generator implementation with an F5 point detector tally in a fixed source problem. The weight window implementation reduced the runtime from 42739.55 minutes to 1803.34 minutes (computer time), compared to the F5 KCODE implementation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NCERC 2024 Highlights

The National Nuclear Security Administration (NNSA) is entrusted with ensuring the safety, security, and reliability of the nation’s nuclear weapons stockpile while advancing programs aimed at reducing global nuclear proliferation. These critical mission objectives are achieved through the expertise of a highly skilled team of professionals. The operations at the National Criticality Experiments Research Center (NCERC) play a vital role in developing and enhancing knowledge and expertise in advanced nuclear technologies. NCERC supports a wide range of mission areas, including nuclear criticality safety, nuclear emergency response, and nuclear nonproliferation, safeguards, and arms control. It also provides support to the Department of Homeland Security, advances stockpile stewardship science, and delivers scientific expertise to other government agencies, such as NASA and the Defense Threat Reduction Agency. NCERC conducts experiments utilizing diverse nuclear materials, from small neutron-emitting sources for testing radiation detection equipment to larger quantities of uranium and plutonium for criticality experiments. A cornerstone of NCERC's mission portfolio includes the operation of four critical mass assembly machines—Planet, Comet, Flattop, and Godiva-IV—which are instrumental in advancing nuclear science and ensuring the nation’s nuclear security objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Measurement of the 237 Np($n$, γ) 238 Np Cross Section with Fast Neutrons

Accurate knowledge of the 237 Np($n$; γ) 238 Np cross section at fast neutron energies is important for applied nuclear science. The presently available experimental data has large disagreements in the fast neutron region. A measurement of the 237 Np($n$; γ) 238 Np cross section was performed using a well characterized fast neutron source and the results was compared with previous measurements and current nuclear data evaluations. This will provide an integral measurement that can be used as a benchmark for current evaluations. Multiple samples of 237 Np were irradiated in the Godiva-IV critical assembly. Following the irradiation, the samples placed in a γ-ray counting setup and the γ-rays emitted from the decay of 238 Np were measured over a time period of approximately 7 days. Multiple γ-ray decay branches of 238 Np were observed. The observed activity of 238 Np was used to calculate the amount of 238 Np produced during the irradiation via the 237 Np($n$; γ) 238 Np and an integral cross section of 359(10) mb was measured. The 238 Np half-life has been measured with a result of 50.34(7) hours. An integral measurement of the 237 Np($n$; γ) 238 Np cross section has been measured. This result has been compared to the calculated integral cross section using the ENDF/BVIII.0 and JENDL-4.0 evaluated cross sections and found to be in good agreement with ENDF/BVIII.0 value of 367 mb. The JENDL-4.0 evaluation yields a value of 312 mb, which is significantly lower than the measured cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗