Status report of the heavy ions source research and development for Spiral2

The physics background requiring a very intense multicharged heavy ion source for Spiral2 is explained. The new Spiral2 low energy beam line dedicated to the heavy ions production and equipped with PHOENIX V2 ECRIS is presented. A status of the A-PHOENIX commissioning at 18 GHz is summarized. A new hybrid ECRIS concept with a cryogenic permanent magnet hexapole is proposed as an improvement of A-PHOENIX technology.

43 PARTICLE ACCELERATORS↗

Model for the description of ion beam extraction from electron cyclotron resonance ion sources

The finite difference method trajectory code KOBRA3-INP has been developed now for 25 years to perform the simulation of ion beam extraction in three dimensions. Meanwhile, the code has been validated for different applications: high current ion beam extraction from plasma sources for ion implantation technology, neutral gas heating in fusion devices, or ion thrusters for space propulsion. One major issue of the development of this code was to improve the flexibility of the applied model for the simulation of different types of particle sources. Fixed emitter sources might be simulated with that code as well as laser ion sources, Penning ion sources, electron cyclotron resonance ion sources (ECRISs), or H{sup -} sources, which require the simulation of negative ions, negative electrons, and positive charges simultaneously. The model which has been developed for ECRIS has now been used to explore the conditions for the ion beam extraction from a still nonexisting ion source, a so called ARC-ECRIS [P. Suominen and F. Wenander, Rev. Sci. Instrum. 79, 02A305 (2008)]. It has to be shown whether the plasma generator has similar properties like regular ECRIS. However, the emittance of the extracted beam seems to be much better compared to an ECRIS equipped with a hexapole.

43 PARTICLE ACCELERATORS↗

Development of a new photoelectron spectroscopy instrument combining an electrospray ion source and photoelectron imaging

A new apparatus has been constructed that combines electrospray ionization with a quadrupole mass filter, hexapole ion trap, and velocity-map imaging. The purpose is to record photoelectron images of isolated chromophore anions. To demonstrate the capability of our instrument we have recorded the photodetachment spectra of isolated deprotonated phenol and indole anions. To our knowledge, this is the first time that the photodetachment energy of the deprotonated indole anion has been recorded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The preliminary tests of the superconducting electron cyclotron resonance ion source DECRIS-SC2

A new compact version of the ''liquid He-free'' superconducting ECR ion source, to be used as an injector of highly charged heavy ions for the MC-400 cyclotron, is designed and built at the Flerov Laboratory of Nuclear Reactions in collaboration with the Laboratory of High Energy Physics of JINR. The axial magnetic field of the source is created by the superconducting magnet and the NdFeB hexapole is used for the radial plasma confinement. The microwave frequency of 14 GHz is used for ECR plasma heating. During the first tests, the source shows a good enough performance for the production of medium charge state ions. In this paper, we will present the design parameters and the preliminary results with gaseous ions.

43 PARTICLE ACCELERATORS↗

Optimization of a charge-state analyzer for electron cyclotron resonance ion source beams

A detailed experimental and simulation study of the extraction of a 24 keV He{sup +} beam from an ECR ion source and the subsequent beam transport through an analyzing magnet is presented. We find that such a slow ion beam is very sensitive to space-charge forces, but also that the neutralization of the beam's space charge by secondary electrons is virtually complete for beam currents up to at least 0.5 mA. The beam emittance directly behind the extraction system is 65 {pi} mm mrad and is determined by the fact that the ion beam is extracted in the strong magnetic fringe field of the ion source. The relatively large emittance of the beam and its non-paraxiality lead, in combination with a relatively small magnet gap, to significant beam losses and a five-fold increase of the effective beam emittance during its transport through the analyzing magnet. The calculated beam profile and phase-space distributions in the image plane of the analyzing magnet agree well with measurements. The kinematic and magnet aberrations have been studied using the calculated second-order transfer map of the analyzing magnet, with which we can reproduce the phase-space distributions of the ion beam behind the analyzing magnet. Using the transfer map and trajectory calculations we have worked out an aberration compensation scheme based on the addition of compensating hexapole components to the main dipole field by modifying the shape of the poles. The simulations predict that by compensating the kinematic and geometric aberrations in this way and enlarging the pole gap the overall beam transport efficiency can be increased from 16% to 45%.

43 PARTICLE ACCELERATORS↗

Fast camera studies at an electron cyclotron resonance table plasma generator

A simple table-size ECR plasma generator operates in the ATOMKI without axial magnetic trap and without any particle extraction tool. Radial plasma confinement is ensured by a NdFeB hexapole. The table-top ECR is a simplified version of the 14 GHz ATOMKI-ECRIS. Plasma diagnostics experiments are planned to be performed at this device before installing the measurement setting at the “big” ECRIS. Recently, the plasma generator has been operated in pulsed RF mode in order to investigate the time evolution of the ECR plasma in two different ways. (1) The visible light radiation emitted by the plasma was investigated by the frames of a fast camera images with 1 ms temporal resolution. Since the visible light photographs are in strong correlation with the two-dimensional spatial distribution of the cold electron components of the plasma it can be important to understand better the transient processes just after the breakdown and just after the glow. (2) The time-resolved ion current on a specially shaped electrode was measured simultaneously in order to compare it with the visible light photographs. The response of the plasma was detected by changing some external setting parameters (gas pressure and microwave power) and was described in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study on a negative hydrogen ion source with hot cathode arc discharge

A negative hydrogen (H{sup −}) ion source with hot cathode arc discharge was designed and fabricated as a primary injector for a 10 MeV PET cyclotron at IMP. 1 mA dc H{sup −} beam with ε {sub N,} {sub RMS} = 0.08 π mm mrad was extracted at 25 kV. Halbach hexapole was adopted to confine the plasma. The state of arc discharge, the parameters including filament current, arc current, gas pressure, plasma electrode bias, and the ratio of I{sub e{sup −}}/I{sub H{sup −}} were experimentally studied. The discussion on the result, and opinions to improve the source were given.

43 PARTICLE ACCELERATORS↗

Differential and integral cross sections in OH(X) + Xe collisions

Differential cross sections (DCSs) for inelastic collisions of OH(X) with Xe have been measured at a collision energy of 483 cm{sup −1}. The hydroxyl (OH) radicals were initially prepared in the X{sup 2}Π{sub 3/2} (v = 0, j = 1.5, f) level using the hexapole electric field selection method. Products were detected state-selectively by [2 + 1] resonance-enhanced multiphoton ionization of OH, combined with velocity-map imaging. Integral cross sections in OH(X) + Xe at a collision energy of 490 cm{sup −1} were also measured by laser-induced fluorescence. The results are compared with exact close-coupling quantum mechanical scattering calculations on the only available ab initio potential energy surface (PES). The agreement between experimental and theoretical results is generally very satisfactory. This highlights the ability of such measurements to test the available PES for such a benchmark open-shell system. The agreement between experiment and theory for DCSs is less satisfactory at low scattering angles, and possible reasons for this disagreement are discussed. Finally, theoretical calculations of OH(X) + He DCSs have been obtained at various collision energies and are compared with those of OH(X) + Xe. The role of the reduced mass in the DCSs and partial cross sections is also examined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vortex Pump for Dilute Bose-Einstein Condensates

The formation of vortices by topological phase engineering has been realized experimentally to create the first two- and four-quantum vortices in dilute atomic Bose-Einstein condensates. We consider a similar system, but in addition to the Ioffe-Pritchard magnetic trap we employ an additional hexapole field. By controlling cyclically the strengths of these magnetic fields, we show that a fixed amount of vorticity can be added to the condensate in each cycle. In an adiabatic operation of this vortex pump, the appearance of vortices into the condensate is interpreted as the accumulation of a local Berry phase. Our design can be used as an experimentally realizable vortex source for possible vortex-based applications of dilute Bose-Einstein condensates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Molecular fountain.

A molecular fountain directs slowly moving molecules against gravity to further slow them to translational energies that they can be trapped and studied. If the molecules are initially slow enough they will return some time later to the position from which they were launched. Because this round trip time can be on the order of a second a single molecule can be observed for times sufficient to perform Hz level spectroscopy. The goal of this LDRD proposal was to construct a novel Molecular Fountain apparatus capable of producing dilute samples of molecules at near zero temperatures in well-defined user-selectable, quantum states. The slowly moving molecules used in this research are produced by the previously developed Kinematic Cooling technique, which uses a crossed atomic and molecular beam apparatus to generate single rotational level molecular samples moving slowly in the laboratory reference frame. The Kinematic Cooling technique produces cold molecules from a supersonic molecular beam via single collisions with a supersonic atomic beam. A single collision of an atom with a molecule occurring at the correct energy and relative velocity can cause a small fraction of the molecules to move very slowly vertically against gravity in the laboratory. These slowly moving molecules are captured by an electrostatic hexapole guiding field that both orients and focuses the molecules. The molecules are focused into the ionization region of a time-of-flight mass spectrometer and are ionized by laser radiation. The new molecular fountain apparatus was built utilizing a new design for molecular beam apparatus that has allowed us to miniaturize the apparatus. This new design minimizes the volumes and surface area of the machine allowing smaller pumps to maintain the necessary background pressures needed for these experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Application of a High-Temperature Linear Ion Trap Reactor

A high-temperature linear ion trap reactor with hexapole design was homemade to study ion–molecule reactions at variable temperatures. The highest temperature for the trapped ions is up to 773 K, which is much higher than those in available reports. The reaction between V{sub 2}O{sub 6}{sup −} cluster anions and CO at different temperatures was investigated to evaluate the performance of this reactor. The apparent activation energy was determined to be 0.10 ± 0.02 eV, which is consistent with the barrier of 0.12 eV calculated by density functional theory. This indicates that the current experimental apparatus is prospective to study ion–molecule reactions at variable temperatures, and more kinetic details can be obtained to have a better understanding of chemical reactions that have overall barriers. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Novel Environmental Cell for In-Situ Gas Reaction Experiments via Aberration-Corrected STEM Imaging

A novel heating technology composed of a disposable MEMS-based (microelectromechanical systems) device has recently been developed and shown to provide unique in-situ heating capabilities in electron microscopes [1]. Protochips, Inc. (Raleigh, NC) provides the AduroTM heater technology, composed of a disposable MEMS device that serves both as the heating element and the specimen support grid, a TEM holder with electrical feed-throughs, and an external current source. This system has been shown to provide near instantaneous (106 C/s) heating and cooling, and is stable to the limit of the microscope's specimen stage so full sub- ngstr m image resolution in highangle annular dark-field imaging mode can be achieved on our JEOL 2200FS scanning transmission electron microscope (STEM/TEM) instrument, fitted with a hexapole corrector on the probe-forming lenses (CEOS GmbH, Heidelberg, Ger.). This heating technology is being extended to function in a closed cell system that allows heating in a gaseous environment for in-situ elevated temperature reaction studies. The design concepts and early results of testing of the environmental cell (E-cell) performance are detailed here.

aberration-corrected↗

Design and Control of Three-Dimensional Topological Magnetic Fields Using Interwoven Helical Nanostructures

Three-dimensional (3D) magnetic nanostructures are an emerging platform capable of creating complex topological magnetic fields. The control of localized nanoscale magnetic fields is seen to be of importance for diverse areas from bioapplications such as drug delivery, to particle trapping and controlling Majorana Fermions for quantum computing. Three-dimensional geometric confinement and proximity can create tailor-made spin textures not possible in two dimensions. The control of magnetization afforded here can allow the formation of unique stray field textures. Here, we report the creation of reconfigurable 3D topological magnetic field textures induced by an interwoven 3D nanostructure and applied field protocol. These field textures emerge due to distinct DWs formed in this structure and lead to the creation of an antivortex field, a hexapole cusp and a 3D skyrmion field tube of mixed chirality. In conclusion, our results therefore show a key step toward the design and control of topological magnetic fields on the nanoscale.

36 MATERIALS SCIENCE↗

An Experimental and Computational Investigation into the Gas-Phase Acidities of Tyrosine and Phenylalanine: Three Structures for Deprotonated Tyrosine

Using mass spectrometry and correlated molecular orbital theory, three deprotonated structures were revealed for the amino acid tyrosine. The structures were distinguished experimentally by ion/molecule reactions involving proton transfer and trimethylsilyl azide. Gas-phase acidities from proton transfer reactions and from G3(MP2) calculations generally agree well. The lowest energy structure, which was only observed experimentally using electrospray ionization from aprotic solvents, is deprotonated at the carboxylic acid group and is predicted to be highly folded. A second unfolded carboxylate structure is several kcal/mol higher in energy and primarily forms from protic solvents. Protic solvents also yield a structure deprotonated at the phenolic side chain, which experiments find to be intermediate in energy to the two carboxylate forms. G3(MP2) calculations indicate that the three structures differ in energy by only 2.5 kcal/mol, yet they are readily distinguished experimentally. Structural abundance ratios are dependent upon experimental conditions, including the solvent and accumulation time of ions in a hexapole. Under some conditions, carboxylate ions may convert to phenolate ions. For phenylalanine, which lacks a phenolic group, only one deprotonated structure was observed experimentally when electrosprayed from protic solvent. This agrees with G3(MP2) calculations that find the folded and unfolded carboxylate forms to differ by 0.3 kcal/mol.

Environmental Molecular Sciences Laboratory↗

Self-frequency summing in quantum dot photonic crystal nanocavity lasers

We demonstrate self-frequency summing in photonic crystal nanocavity lasers with quantum dot gain. Two dipole modes and a hexapole mode, supported in the cavity, simultaneously showed lasing oscillation in the near infrared wavelength region under optical carrier injection. Meanwhile, within the same laser cavity, the internally generated three laser fields are up-converted to exhibit sharp visible emission lines via intra-cavity nonlinear frequency summing (and doubling) processes. This self-frequency summing process in active nanocavities will pave the way for developing nanoscale nonlinear optical light sources.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fully quantum state-resolved inelastic scattering of NO(X) + Kr: Differential cross sections and product rotational alignment

Fully quantum state selected and resolved inelastic scattering of NO(X) by krypton has been investigated. Initial Λ-doublet state selection is achieved using an inhomogeneous hexapole electric field. Differential cross sections and even-moment polarization dependent differential cross sections have been obtained at a collision energy of 514 cm{sup −1} for both spin-orbit and parity conserving and changing collisions. Experimental results are compared with those obtained from quantum scattering calculations and are shown to be in very good agreement. Hard shell quantum scattering calculations are also performed to determine the effects of the different parts of the potential on the scattering dynamics. Comparisons are also made with the NO(X) + Ar system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new Stark decelerator based surface scattering instrument for studying energy transfer at the gas-surface interface

We report on the design and characterization of a new apparatus for performing quantum-state resolved surface scattering experiments. The apparatus combines optical state-specific molecule preparation with a compact hexapole and a Stark decelerator to prepare carrier gas-free pulses of quantum-state pure CO molecules with velocities controllable between 33 and 1000 m/s with extremely narrow velocity distributions. The ultrahigh vacuum surface scattering chamber includes homebuilt ion and electron detectors, a closed-cycle helium cooled single crystal sample mount capable of tuning surface temperature between 19 and 1337 K, a Kelvin probe for non-destructive work function measurements, a precision leak valve manifold for targeted adsorbate deposition, an inexpensive quadrupole mass spectrometer modified to perform high resolution temperature programmed desorption experiments and facilities to clean and characterize the surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗