Search NASA⌕ Search

SEARCH · Search NASA

Results for “HVAC SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Impact of refrigerant undercharge faults on building indoor conditions and HVAC system operation in residential Buildings: A simulation study

This study investigates the impact of refrigerant undercharge on indoor temperature and HVAC system performance in residential buildings. Simulation models for typical residential buildings in Orlando, FL and Indianapolis, IN were developed using the ResStock database. A refrigerant undercharge fault model was then applied to the simulations with varying levels of fault intensity. The paper offers an extensive analysis, revealing that variations in supply air temperature, equipment runtime, and cooling energy consumption due to the level of refrigerant undercharge faults are notably significant on a summer representative day. Similarly, on a winter representative day, changes in supply air temperature and runtime are significant as well as changes in supplemental heat energy consumption. We find that occupants may remain oblivious to these faults during the cooling season, particularly when the HVAC system is oversized; in that case, supply air temperature data could help detect a fault. Another challenge is that during the heating season, when the supplemental heater operates, it is difficult to identify a refrigerant undercharge fault using only indoor and supply air temperature data. Finally, this study finds that supply air temperature, equipment runtime, and supplemental heater energy consumption data can help in detecting refrigerant undercharge faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Convergence Rate of Model Reference Adaptive Control with Application to Building HVAC Systems

Model reference adaptive control (MRAC) has been studied for decades and successfully applied in multiple areas, including heating, ventilation, and air conditioning (HVAC) systems for buildings. MRAC is efficient in capturing the time-varying characteristics of buildings' indoor temperatures and outdoor weather environments. In this paper, the rate of convergence of MRAC is investigated, where a direct adaptive control with temperature set point reference tracking is used to regulate the indoor temperatures for buildings. Numerical results show that by controlling the HVAC systems of residential buildings using MRAC, the indoor temperatures converge Q-sublinearly to the desired temperature set points. In addition, the rate of convergence for MRAC is compared with a baseline adaptive model-free control method.

Wu, Tumin↗

Dialogue Between Lighting and HVAC Systems: Improving building system integration

Lighting systems have long been capable of sensing when someone enters or exits a room and using that knowledge to turn lights on or off. More recently, connected lighting systems with sensors integrated into every luminaire have become broadly available, facilitating highly granular occupancy detection. Similarly, HVAC systems have long been able to use an understanding of building occupancy to adjust temperature setpoints and reduce energy use without significant impacts to occupant comfort. Energy codes (e.g., ASHRAE/IES Standard 90.1, IECC, Title 24) now require “occupied standby HVAC control,” whereby systems adjust both temperature and ventilation setpoints in zones that are determined to be unoccupied during normal occupancy hours. Here, this article discusses current issues that stymie the integration of Lighting and HVAC systems, and DOE activities focused on addressing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Signal Temporal Logic Control for Residential HVAC Systems to Accommodate High Solar PV Penetration

This paper proposes a new signal temporal logic (STL) control for ON/OFF residential buildings' Heating Ventilation and Air Conditioning (HVAC) systems. STL is used to control indoor temperatures while consuming most of the generated solar photovoltaic (PV) power locally to minimize its impact on the grid and reduce the need for large energy storage devices. In contrast to most, if not all, control mechanisms such as the traditional model predictive control (MPC), STL control allows for including temporal constraints in the control formulation to further relax indoor temperatures' constraints and allow them to exceed the comfort band limits for a prespecified (short) period of time. This relaxation allows to consume an additional PV power by the HVAC systems, which prevents such an unwanted intermittent power from affecting the grid. We formulate the MPC-based STL control mechanism to implement the objective. Simulation results show that the PV tracking performance has been improved while employing the proposed STL controller.

Wu, Tumin↗

Lessons learned from the development and implementation of a workforce training curriculum for advanced controls for high performance HVAC systems

Over the past decade, academic research on advanced controls has slowly transitioned into new software platforms, giving rise to various companies developing and deploying these innovative products, including solutions for light commercial HVAC systems. However, the current workforce remains widely unprepared to install, maintain and operate these systems, particularly complex software-based control platforms, as most workforce training programs still focus on traditional building automation for large commercial buildings. This paper presents the development and piloting of curriculum for three key types of professionals: ● Technicians (trade-level): installing and maintaining modern high-performance HVAC systems and controls ● Programmers (undergrad-level): developing and implementing advanced controls ● Engineers and energy professionals (undergrad/grad-level): managing and evaluating system performance We share details of the material developed including training videos, open-source software, instruction manuals. We also present the results of a pilot implementation of the training materials with real students.

Casillas, Armando↗

EMPIRICAL VALIDATION OF MULTI-ZONE BUILDING AND HVAC SYSTEM MODELS UNDER UNCERTAINTY

This study implemented a framework of empirical validation of building energy models under uncertainty to a set of controlled experiments that aim to validate multi-zone building and HVAC system models. Energy models were created through iterative acquisitions of information and data and uses measurement data from various types of sensors as both inputs and as observations to validate predictions. Experimental and modeling uncertainties were quantified and propagated accordingly, and probabilistic accuracy metrics were used to evaluate the agreement between model predictions and observations under uncertainty. Sensitivity analysis was performed to identify the most influential uncertainties that will be prioritized to be addressed in the next steps. Current results of two cooling tests show an overall good agreement between predictions and observations on a set of HVAC system outputs despite considerable and influential uncertainty in DX cooling coil COP. Agreements on zone-level responses vary notably among individual rooms, likely because of significant uncertainties in room radiation heat gain and system supply air.

Li, Qi↗

Field-based AFDD for refrigerant undercharge in residential HVAC systems: enhancing reliability through false alarm mitigation

This study evaluated rule-based and machine learning (ML) based automated fault detection and diagnostics (AFDD) algorithms for detecting refrigerant undercharge faults in residential heating, ventilation, and air conditioning (HVAC) systems, using actual building data and a minimal set of features. The ML-based algorithms included Decision Tree (DT) and K-Nearest Neighbors (KNN). Both the rule-based and ML-based algorithms demonstrated the capability to detect refrigerant undercharge faults of -30% or more. Both types of algorithms exhibited false alarms before the implementation of a false alarm mitigation algorithm, which motivated the development of such a mitigation strategy. After applying the mitigation, false alarms were substantially reduced, with the rule-based algorithm decreasing to 0.6% and the ML-based algorithms reaching 0%, while maintaining strong detection performance. Although the rule-based algorithm initially showed lower performance compared to the ML-based algorithms, its detection accuracy improved after mitigation to a level comparable to the ML-based algorithms. These results confirm that combining false alarm mitigation with both rule-based and ML-based AFDD algorithms significantly enhances practical reliability while preserving robust fault detection capabilities. Furthermore, the findings demonstrate the potential for field deployment of these algorithms in residential HVAC systems and highlight the importance of minimizing false alarms.

False Alarm↗

Online Dynamic Mode Decomposition Based System Identification of Multi-Zone Building HVAC Systems

Many works have recently been conducted to reduce the electricity consumption of smart buildings and allow them to support various grid services. Most of these works require accurate system models for the various appliances in the building including heating, ventilation, and air conditioning (HVAC) units. In this paper, we investigate a recursive data-driven system identification strategy to construct the thermal model for a time-varying building with a multi-zone HVAC unit. The online dynamic mode decomposition (DMD)-based strategy is employed to identify the multi-zone thermal building dynamics, where a simple information update (rank-1) is selected to avoid computational complexity. The DMD-based identification strategy is validated using a real gymnasium building equipped with a 4-zone HVAC unit, and its performance is compared with that of the traditional nuclear-norm subspace identification (N2SID) strategy.

Wu, Tumin [University of Tennessee, Knoxville (UTK↗

Analysis of predicted mean vote-based model predictive control for residential HVAC systems

Model Predictive Control (MPC) is an advanced process control method that has attracted much attention in building heating, ventilation, and air conditioning (HVAC) systems. Here, this paper analyzes the optimal precooling performance in residential buildings using MPC with two different comfort indices, namely, temperature and predicted mean vote (PMV). It first formulates, for each comfort index, an optimization problem that accounts for different factors, such as weather, home thermal condition, prediction horizon, time-of use (TOU) utility rate, and rated cooling capacity. The problem is then solved, resulting in an MPC strategy that determines the HVAC on/off control signal and minimizes energy cost over a receding time horizon while maintaining thermal comfort. The energy performance difference between temperature-based and PMV-based MPC strategies is subsequently investigated, especially in light of the interior wall surface temperature and under different combinations of the factors. Extensive simulation results demonstrated that the proposed MPC strategies are adaptive and their performances depend primarily on weather, home thermal condition, and prediction horizon, while the impact of TOU utility rate and rated cooling capacity is relatively small. Because the PMV-based MPC strategy can take advantage of the lower interior wall surface temperature due to precooling, it resulted in 8–45% cost savings for the scenarios investigated and an average increase of 0.042–0.113 in the absolute value of the PMV index compared to the temperature-based MPC strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

A labeled dataset for building HVAC systems operating in faulted and fault-free states

Abstract Open data is fueling innovation across many fields. In the domain of building science, datasets that can be used to inform the development of operational applications - for example new control algorithms and performance analysis methods - are extremely difficult to come by. This article summarizes the development and content of the largest known public dataset of building system operations in faulted and fault free states. It covers the most common HVAC systems and configurations in commercial buildings, across a range of climates, fault types, and fault severities. The time series points that are contained in the dataset include measurements that are commonly encountered in existing buildings as well as some that are less typical. Simulation tools, experimental test facilities, and in-situ field operation were used to generate the data. To inform more data-hungry algorithms, most of the simulated data cover a year of operation for each fault-severity combination. The data set is a significant expansion of that first published by the lead authors in 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field demonstration and implementation analysis of model predictive control in an office HVAC system

Model Predictive Control (MPC) is a promising technique to address growing needs for heating, ventilation, and air-conditioning (HVAC) systems to operate more efficiently and with greater flexibility. However, due to a number of factors, including the required implementation expertise, lack of high quality data, and a risk-adverse industry, MPC has yet to gain widespread adoption. While many previous studies have shown the advantages of MPC, few analyzed the implementation effort and associated practical challenges. In addition, previous work has developed an open-source, Modelica-based tool-chain that automatically generates optimal control, parameter estimation, and state estimation problems aimed at facilitating MPC implementation. Therefore, this study demonstrates usage of this tool-chain to implement MPC in a real office building, discusses practical challenges of implementing MPC, and estimates the implementation effort associated with various tasks in order to inform the development of future workflows and serve as an initial benchmark for their impact on reducing implementation effort. This study finds that the implemented MPC saves approximately 40% of HVAC energy over the existing control during a two-month trial period and that tasks related to data collection and controller deployment activities can each require as much effort as model generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated fault detection and diagnosis of airflow and refrigerant charge faults in residential HVAC systems using IoT-enabled measurements

While automated fault detection and diagnosis (AFDD) in residential heating, ventilation, and air-conditioning (HVAC) using smart thermostat data is gaining increasing attention in recent times, it still requires in-depth investigation for market adoption, especially with real-life data. Furthermore, this paper proposes an Internet of Things (IoT) - based approach that adds a smart sensor to the smart thermostat data to carry out AFDD. The approach uses a model which predicts enthalpy change across the evaporator and compares the prediction to the measured enthalpy change. Deviations which exceed analytically determined thresholds then signal faults in the HVAC system. The faults detected are either installation related or degradation related. Experimental tests were carried out in four homes located in Norman, Oklahoma. From the tests, installation issues like indoor/outdoor mismatch were detected in two homes, while a 30% low charge and low indoor airflow rate were detected in one home. The results show that the proposed AFDD algorithm was able to successfully detect two prevalent faults, namely low indoor airflow and low refrigerant charge. Unlike most of the smart thermostat-based approaches, the proposed IoT-based approach can detect and diagnose both faults but only require one additional sensor which is provided by smart thermostat manufacturers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive Control for Residential HVAC Systems to Support Grid Services

In this paper, we propose an adaptive control strategy for residential buildings' heating ventilation and air conditioning (HVAC) systems to support grid services. The proposed control strategy captures the time-varying characteristics of the building and weather environments. It assigns to each building a local controller to maintain the indoor temperature within a desired comfort level, while the load aggregator allocates the assigned reference power provided by the distribution system operator to support a specific grid service, such as demand peak reduction, balancing supply and demand, and consuming the solar photovoltaic (PV) power locally. Simulation results are presented to verify the performance of the proposed control strategy in terms of maintaining the indoor temperatures of several buildings within the desired comfort bands while tracking the reference power profile. Also, a comparison with a recently developed model-free control strategy is presented.

Wu, Tumin↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak Demand Limiting and Optimization of HVAC Systems for Common Areas in High-Rise Multi-Family Housing (CRADA 518)

This project aims to create an innovative energy saving solution that is affordable and easy to implement. Initially, the proposed solution will fulfill an existing need for HVAC systems that serve multi-family housing. However, the solution can be easily expanded to other markets such as large hospitals, hotels, and commercial buildings. The proposed solution will be creatively packaged so that it can work where peak demand charge is high or where goal is to conserve energy and reduce carbon footprint. Of course, both Peak Demand Limiting (PDL) and Set-point optimization (SPO) can also operate simultaneously.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Haxall-based (Axon) fault auto-correction package for building HVAC system (Haxall-based Fault Correction) v1.0

Haxall-based Fault Correction is a set of fault auto-correction algorithms implemented using the Axon language. These algorithms can automatically fix equipment and control problems as they arise and improve the operation of building Heating, Ventilation, and Air Conditioning (HVAC) systems. The coded auto-correction algorithms include mitigation of rogue zones, ASHRAE Guideline 36 static pressure and supply air reset, resolution of control hunting due to improper settings in a proportional-integral-derivative controller, correction of biased temperature sensors, etc. FDD tools with enhanced auto-correction capability can resolve control problems as they are detected, increasing energy savings and emissions reductions while freeing up operational staff expertise for the hardest facility problems.

Vitti, Raphael↗