Search NASA⌕ Search

SEARCH · Search NASA

Results for “HYGROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hygrometer for Detecting Water in Partially Enclosed Volumes

A portable hygrometer has been devised to implement a pre-existing technique for detecting water trapped in partially enclosed volumes that may be difficult to reach and cannot be examined directly. The technique is based on the fact that eventually the air in such a volume becomes saturated or nearly so. The technique is straightforward: One measures the relative humidity and temperature of both the ambient air and a sample of air from the enclosed volume. If the relative humidity of the sample is significantly greater than that of the ambient air and/or if the sample is at or close to the dew point, then it can be concluded that water is trapped in the volume. Of course, the success of this technique depends on the existence of an access hole through which one can withdraw some air from the enclosed volume.

Youngquist, Robert C.↗

Quartz-crystal-oscillator hygrometer

Measuring device, which eliminates complex and expensive optical components by electronically sensing dewpoint of water vapor in gas, employs piezoelectric crystal oscillator, supportive circuitry, temperature regulators, and readout.

Kruger, R.↗

Long-lasting solid-polymer electrolytic hygrometer

Device consists of hollow tube node of oxidation-resistant sulfonated fluorocarbon polymer. Tube absorbs moisture from air passing across inner and outer surfaces, causing change in polymer conductance. Change is related to change in water content in gas sample.

Lawson, D. D.↗

In situ measurement of water vapor in the stratosphere with a cryogenically cooled Lyman-alpha hygrometer

In situ measurements of water vapor in the stratosphere with a new instrument are reported. The instrument has been designed to observe daytime water vapor from a multiinstrument balloon gondola that simultaneously measures free radicals such as OH, HO2, and O3 in the stratosphere up to 40 km. Lyman-alpha photofragment fluorescence is used to measure water molecules in a flowing sample of ambient air. A brief description of the instrument is given, followed by the results of the first four balloon flights. The measured mixing ratio for this flight varies from 3.0-5.5 ppmv over the altitude range of 17-34 km. Adjustments in the cooling protocol for the flights of July 6, 1988, July 28, and August 25, 1989, result in a much higher signal-to-noise ratio. Profiles from these three flights are similar to, but somewhat higher, than the 1987 profile. Implications of measurements are discussed, as are the issues of short- and long-term variability of stratospheric water vapor.

Schwab, J. J.↗

Estimation of surface heat and moisture fluxes over a prairie grassland. I - In situ energy budget measurements incorporating a cooled mirror dew point hygrometer

Attention is focused on in situ measurements taken during FIFE required to support the development and validation of a biosphere model. Seasonal time series of surface flux measurements obtained from two surface radiation and energy budget stations utilized to support the FIFE surface flux measurement subprogram are examined. Data collection and processing procedures are discussed along with the measurement analysis for the complete 1987 test period.

Smith, Eric A.↗

High performance miniature hygrometer and method thereof

An uncoated interdigitated transducer is cooled from a temperature above the dew point to a temperature below the dew point, while a parameter of a signal of the transducer is measured. The reduction in temperature causes a monotonic change in transducer signal because that signal is sensitive primarily to the water loading of the transducer surface as water forms on that surface due to the reduction in temperature. As the dew point is approached with temperature reduction, the slope of the curve of transducer signal with respect to temperature, remains relatively constant. However, as the dew point is reached the slope of that curve increases and because of changes in the structure of the water layer on the surface of the transducer, at the dew point the transducer responds with a clear shift in the rate at which the transducer signal changes. The temperature at which the second derivative of signal vs. temperature peaks can be readily used to identify with extreme accuracy, the precise dew point. The measurement technique employed by the present invention is relatively immune to surface contamination which remains significantly unchanged during the brief measurement period.

VanZandt, Thomas R.↗

Mars laser hygrometer

We have designed and built a miniature near-IR tunable diode laser (TDL) spectrometer for measuring in situ the water vapor mixing ratio either in the Martian atmosphere or thermally evolved from Martian soil or ice samples.

['atmospheric↗

A comparison of small and larger mesoscale latent heat and radiative fluxes: December 6 case study

Because of the small amounts of water vapor, the potential for rapid changes, and the very cold temperatures in the upper troposphere, moisture measuring instruments face several problems related to calibration and response. Calculations of eddy moisture fluxes are, therefore, subject to significant uncertainty. The purpose of this study is to examine the importance of latent heat (moisture) fluxes due to small and larger mesoscale circulations in comparison to radiative fluxes within cirrus. Scale separation is made at about 1 km because of significant changes in the structures within cirrus. Only observations at warmer than -40 C are used in this study. The EG&G hygrometer that is used for measuring dewpoint temperature (Td) is believed to be fairly accurate down to -40 C. On the other hand, Lyman-Alpha (L-alpha) hygrometer measurements of moisture may include large drift errors. In order to compensate for these drift errors, the L-alpha hygrometer is often calibrated against the EG&G hygrometer. However, large errors ensue for Td measurements at temperatures less than -40 C. The cryogenic hygrometer frost point measurements may be used to calibrate L-alpha measurements at temperatures less than -40 C. In this study, however, measurements obtained by EG&G hygrometer and L-alpha measurements are used for the flux calculations.

Gultepe, I.↗

Micro Weather Station

Improved in situ meteorological measurements in the troposphere and stratosphere are needed for studies of weather and climate, both as a primary data source and as validation for remote sensing instruments. Following the initial development and successful flight validation of the surface acoustic wave (SAW) hygrometer, the micro weather station program was directed toward the development of an integrated instrument, capable of accurate, in situ profiling of the troposphere, and small enough to fly on a radiosonde balloon for direct comparison with standard radiosondes. On April 23, 1998, working with Frank Schmidlin and Bob Olson of Wallops Island Flight Facility, we flew our instrument in a dual payload experiment, for validation and direct comparison with a Vaisala radiosonde. During that flight, the SAW dewpoint hygrometer measured frostpoint down to -76T at 44,000 feet. Using a laptop computer in radio contact with the balloon, we monitored data in real time, issued the cutdown command, and recovered the payload less than an hour after landing in White Sands Missile Range, 50 miles from the launch site in Hatch, New Mexico. Future flights will extend the intercomparison, and attempt to obtain in situ meteorological profiles from the surface through the tropopause. The SAW hygrometer was successfully deployed on the NASA DC8 as part of NASA's Third Convection and Moisture Experiment (CAMEX-3) during August and September, 1998. This field campaign was devoted to the study of hurricane tracking and intensification using NASA-funded aircraft. In situ humidity data from the SAW hygrometer are currently being analyzed and compared with data from other instruments on the DC8 and ER2 aircraft. Additional information is contained in the original.

Hoenk, Michael E.↗