At least 37 records · Page 2

Modular, thermal bus-to-radiator integral heat exchanger design for Space Station Freedom

The baseline concept is introduced for the 'integral heat exchanger' (IHX) which is the interface of the two-phase thermal bus with the heat-rejecting radiator panels. A direct bus-to-radiator heat-pipe integral connection replaces the present interface hardware to reduce the weight and complexity of the heat-exchange mechanism. The IHX is presented in detail and compared to the baseline system assuming certain values for heat rejection, mass per unit width, condenser capacity, contact conductance, and assembly mass. The spreadsheet comparison can be used to examine a variety of parameters such as radiator length and configuration. The IHX is shown to permit the reduction of panel size and system mass in response to better conductance and packaging efficiency. The IHX is found to be a suitable heat-rejection system for the Space Station Freedom because it uses present technology and eliminates the interface mechanisms.

Chambliss, Joe↗

Transient performance evaluation of an integrated heat pipe-thermal storage system

Transient performance tests of an integrated heat pipe-thermal storage system have been conducted. This system was developed as a part of an Organic Rankine Cycle-Solar Dynamic Power System receiver for future power systems. The integrated system consists of potassium heat pipe elements that incorporate thermal energy storage canisters within the vapor space and an organic fluid (toluene) heater tube used as the condenser region of the heat pipe. The transient performance tests determined the operating characteristics and power input limits of the integrated heat pipe-thermal storage unit under conditions corresponding to re-acquisition of the sun during emergence from eclipse conditions and to the initial start-up of the solar dynamic power system. The tests demonstrated that the heat pipe-thermal storage element is not limited under conditions corresponding to emergence from eclipse during normal orbital operations and the heat pipe will successfully start-up from the frozen condition with full input power at the onset. Details of the test procedures and results of the tests are presented in this paper.

Keddy, E.↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗

FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗

“Hybridizing heat-integrated 3D printed modules with mass manufacturable, low pressure drop fiber sorbents” (Final Report)

The overall objective of this proposal was to research, develop, and evaluate a modular direct air capture (DAC) system that is simple and scalable. This system was based on the adsorption of CO 2 into commercial polyamines supported by porous fiber sorbents, which can be produced at kilometer per hour scales using our pre-pilot spinning line. We have housed these fiber materials in novel 3D printed modular housing systems that provide easy-to-manufacture and localized heat integration and flow control. This hybridization of fiber sorbent technology with modular housing provided several advantages that led to lower air pressure drops, higher sorbent productivity, as well as ease of manufacturing and assembly unrivaled by existing and emerging heat integrated contactor designs. The modular housing was fabricated with the following features, at a minimum: (i) a tapered air intake to reduce pressure drop related to entrance effects, (ii) a structured network of heat transfer channels to enable localized cooling and heating during adsorption and desorption, respectively, and (iii) low pressure drop supports for the fiber sorbents. This hybrid manufacturing approach provides a facile method for taking fiber sorbents from lab scale to pilot scale as it dramatically simplifies the fabrication of heat integrated contactor structures.

42 ENGINEERING↗

Design and development of integral heat pipe/thermal energy storage devices

The major design and performance test subtasks in the development of small (200 to 1,000 whr) integral heat pipe/thermal energy storage devices for use with thermally driven spacecraft cryo-coolers are described. The design of the integral heat pipe/thermal energy storage device was based on a quasi steady resistance heat transfer, lumped capacitance model. Design considerations for the heat pipe and thermal storage annuli are presented. The thermomechanical stress and insulation system design for the device are reviewed. Experimental correlations are described, as are the plans for the further development of the concept.

Mahefkey, E. T.↗

Simulation of a PCM Integrated Heat Pump Using Time-of-Use Utility Structure based Control Strategy for Demand Response

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries and constructing new peaking power plants. The aggressive carbon reduction goals of the United States are accelerating the electrification of building equipment. If space heating and cooling in the US were electrified using conventional heat pump technologies, the winter electric grid peak would approximately double. Integrating TES with heat pump (HP) enables electrification of space cooling and heating devices without overtaxing the grid.This paper evaluates the benefits of a novel phase change material (PCM) integrated heat pump configuration via simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation.To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

Li, Zhenning↗

Simulating a solar parabolic trough collector plant used for industrial process heat using an optimized operating scheme that utilizes flexible heat integration

This study focuses on the modeling and simulation of a novel design and operation of a solar industrial process heat (SIPH) plant that uses a parabolic trough collector system for generating process heat. The SIPH plant incorporates flexible heat integration (FHI) by having two options for heat sinks as well as a flexible collection temperature for the heat transfer fluid. Leveraging the degrees of freedom created by FHI allows an optimized operating scheme to be created which maximizes the solar heat delivered to the industrial processes. Yearly results for a 27 MW-t plant located in Salt Lake City, UT are simulated for a base case and a case utilizing optimized FHI. For the main process temperature case presented, FHI increases the total solar share by 13.0% and reduces the levelized cost of heat of the SIPH plant by 10.4% relative to the base case. Furthermore, three case study days are presented which highlight how FHI maximizes solar share, specifically during mornings, afternoons, and days with intermittent solar conditions. An environmental analysis is also performed showing that the SIPH plant can reduce harmful emissions by 15.4% for the base case and 17.4% for the FHI case compared to a plant that only utilizes a natural gas furnace for process heat. Overall, the work thoroughly explores an effective operating scheme for a SIPH plant, helping to make it more economical and environmentally beneficial.

14 SOLAR ENERGY↗

UKy-CAER Heat Integrated Transformative CO 2 Capture Process in Pulverized Coal Power Plants

The goal of this Phase II Topical Report is to summarize the work for public domain conducted on project DE-FE0031583. Building upon the Design Basis completed during Phase I and in accordance with the Statement of Project Objectives (SOPO), the University of Kentucky (UK) Center for Applied Energy Research (CAER) (Recipient) along with team members has completed the Front End Engineering Design (FEED) for its advanced, versatile post-combustion CO 2 capture system (CCS) at the 10 MWe large pilot scale to be installed at the Wyoming (WY) Integrated Test Center (ITC), using a heat integrated process with split-rich fed, two-stage stripping and any advanced solvent to enhance the CO 2 absorber performance and lower the cost of CO 2 capture. The proposed project (Phases I-III) involves the design, fabrication, installation, testing and evaluation of a large pilot scale facility that will demonstrate the UK CAER transformative CCS integrated with an operating power plant. The work performed in Phase I, detailed in the Phase I Topical Report that was submitted in March 2019, included formation of a project team, securing the host site, and completing pre-FEED design basis, a cost estimation, a preliminary techno-economic analysis (TEA) and an environmental information volume (EIV). The work performed in Phase II, detailed in this Phase II Topical Report, includes completion of FEEDs, completion of a process risk analysis (PRA), obtaining necessary permits, updating the EIV and TEA, updating the cost and schedule estimate for the Phase III scope of work (SOW) and securing the necessary cost share. Updated information is provided on the current status of the UK CAER CCS technology and the project is ready to begin immediately detailed design, construction and operation of the proposed pilot.

20 FOSSIL-FUELED POWER PLANTS↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

RENEWABLE MARINE-SOURCE INTEGRATED HEAT PUMP FOR SPACE CONDITIONING, WATER HEATING, AND FRESH WATER HARVESTING IN REMOTE COASTAL AND ISLAND COMMUNITIES

US coastal and island communities have vulnerable energy infrastructure and high energy costs, which are exacerbated by climate change. A unique opportunity exists to use thermal energy from year-round mild temperature variations to satisfy the broad energy needs of these communities. The US Department of Energy’s Oak Ridge National Laboratory designed a small-scale marine-source integrated heat pump (MS-IHP) that, as a single appliance, combines space conditioning, dehumidification (including fresh water harvesting from humid air), and water heating for home and commercial building applications in remote coastal and island communities. The unique, innovative features of the MS-IHP offer improved efficiency and substantially reduced costs for space conditioning, dehumidification, and water heating by seamlessly integrating a heat pump, heat pump water heater, and dehumidifier by using a single compressor; optimal year-round space cooling and heating, dehumidification, water harvesting, and water heating; and improved thermal comfort and reliable operation without frosting and defrosting because of the ocean’s warm temperatures and high heat capacity. Preliminary testing was conducted by retrofitting a commercial heat pump, demonstrating an outperformed performance compared with traditional air-source heat pumps. The MS-IHP technology can help decarbonize energy systems in remote coastal and island communities.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Development of an integrated heat pipe-thermal storage system for a solar receiver

An integrated heat pipe-thermal storage system was developed as part of the Organic Rankine Cycle Solar Dynamic Power System solar receiver for space station application. The solar receiver incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain thermal energy storage (TES) canisters within the vapor space with a toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the earth orbit, solar energy is delivered to the heat pipe. Part of this thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of earth orbit, the stored energy in the TES units is transferred by the potassium vapor to the toluene heater tube. A developmental heat pipe element was constructed that contains axial arteries and a distribution wick connecting the toluene heater and the TES units to the solar insolation surface of the heat pipe. Tests were conducted to demonstrate the heat pipe, TES units, and the heater tube operation. The heat pipe element was operated at design input power of 4.8 kW. Thermal cycle tests were conducted to demonstrate the successful charge and discharge of the TES units. Axial power flux levels up to 15 watts/sq cm were demonstrated and transient tests were conducted on the heat pipe element. Details of the heat pipe development and test procedures are presented.

Keddy, E.↗

Application of a Heat Integrated Post-combustion CO 2 Capture System with Hitachi Advanced Solvent into Existing Coal-Fired Power Plant (Final Technical Report)

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0007395. In accordance with the Project Management Plan (PMP), Revision F dated 5/10/2019, and Statement of Project Objectives (SOPO) within, the University of Kentucky (UK) Center for Applied Energy Research (CAER) (Recipient) has successfully demonstrated a unique, versatile CO 2 capture system (CCS) using a heat integrated process combined with two-stage stripping for process intensification, heat recovery and demineralized (DM) water generation. This project involved the design, fabrication, installation, testing of and data analysis from the UK CAER 0.7 MWe small pilot scale CO2 capture process installed at Kentucky Utilities (KU) E.W. Brown Generating Station in Harrodsburg, KY. During each of the four project Budget Periods (BPs), UK CAER met all project deliverables, all project milestones, with National Energy Technology Laboratory (NETL) approved adjustments made to the campaign long-term hours during BP4. The CCS was constructed in modular skids. Two solvent campaigns were initially conducted; the first with a 30 wt% monoethanolamine (MEA) as a baseline, and the second with the Hitachi H3-1 advanced solvent. Additional tests were performed with two advanced solvents including CAER and Proprietary Solvent C. Short-period testing with a higher concentration of 40 wt% MEA was conducted to evaluate the potential saving with high alkalinity. From the various solvent campaigns, unique aspects of the UK CAER CCS technology, as well as its flexibility and versatility were experimentally validated and demonstrated. With respect to solvent evaluation efforts in identifying candidates with significant operational and capital cost savings potential, performance of solvents were evaluated to determine the energy requirements for regeneration; environmental impacts from secondary emissions and degradation products; degradation rates, solvent make-up rates and stability. The assessments were done from parametric tests that determined optimum operating conditions for the individual solvents to maximize process efficiency and minimize the parasitic load of the power plant, and from long term campaigns (1000 hours for 30 wt% MEA and 1000 hours for H3-1) which collectively informed the techno-economic analyses (TEA) of the process. The long term campaigns included corrosion studies which used three types of metal coupons in different sections of the process: (absorber, primary stripper, lean carbon-loaded and rich carbon loaded flow streams in process) to mimic heat and flow dynamics process equipment were exposed to. The estimated corrosion rates were used to elucidate corrosion mechanisms and to further guide process material selection for potential capital cost savings.

gas separation↗

Dynamic optimization and economic evaluation of flexible heat integration in a hybrid concentrated solar power plant

Hybridization of concentrated solar power (CSP) plants provides flexibility in operation that can drastically improve the solar-to-electric (STE) efficiency and levelized cost of electricity (LCOE) relative to standalone CSP plants. Flexible heat integration (FHI) is a novel concept where the collection and integration of CSP within a power plant is modified relative to the amount of solar energy available. FHI improves the thermal efficiency of a hybrid solar tower steam Rankine cycle power plant but leads to increased pumping needs due to continuously elevated molten salt flow rates through the collection system, which can negatively impact STE efficiency. The present work is carried out to maximize the STE efficiency of a hybrid CSP plant utilizing FHI by employing a dynamic optimization framework where a genetic algorithm optimizes the operation of the plant over a given solar irradiance profile. The study concerns a plant hypothetically located in Salt Lake City, Utah. Here, the optimization results confirm the accuracy of a predictive heuristic where the preferred operation of the plant can be estimated relative to local peaks in the incident power generated by the heliostat collection field. The optimized FHI operation demonstrates a yearly STE efficiency of 13.8%, whereas the equivalent base-level hybrid and solar-only plants exhibit solar efficiencies of 13.4% and 11.2%, respectively. Economic analysis shows that FHI reduces yearly natural gas costs, leading to a $\$0.5$/MWh reduction in LCOE relative to the base-level hybrid configuration. Overall, the results show that hybrid FHI schemes exhibit economic benefits along with observed thermodynamic improvements.

14 SOLAR ENERGY↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

Thermal Systems Modeling of Chemical Heat Integrated Power Source (CHIPS) to Survive Lunar Night Environments

This paper presents the results of the systems level thermal modeling for a conceptual Chemical Heat Integrated Power Source (CHIPS). This proposed system offers a combined thermal and electrical power source to support survival of spacecraft operating in extreme low temperature lunar environments, without the use of radioisotope-based sources. A conceptual design study has been completed for this system, that uses heat generated by an exothermic chemical reaction in place of radioisotope or electrical heat sources. The goal of the study was to evaluate the feasibility of such a system through thermodynamic and chemical analysis and thermal modeling, and to identify technology gaps to inform a technology development and maturation plan. The specific technical objectives focused on delivery of 90 to 100 Wth thermal power and 30 to 40 We electrical power for 336 hours to a representative Commercial Lunar Payload Services (CLPS) lander, to support lunar surface survival and limited operations through a lunar night. The total system mass was targeted at ≤50 kg. A highly exothermic chemical reaction system is used to generate on-board electrical power for spacecraft systems, and thermal power to maintain critical spacecraft/lander systems within their allowable flight temperature (AFTs). Based on the very high energy content of the chemical reaction system, a much higher amount of heat per unit mass can be delivered to the spacecraft, relative to a rechargeable lithium-ion battery and electrical heater(s). Since radioisotope heaters or generators are not used, the system will be orders of magnitude lower in cost than a radioisotope heating/power unit, without the attendant regulatory complexities. As part of the CHIPS concept, a fraction of the thermal power generated is converted to electrical power via an appropriate thermal-to-electric converter technology (such as a free piston Stirling converter or a thermoelectric generator module), to provide power to critical loads. This approach is ideally suited to support operation of commercial landers (e.g., via the CLPS program). In most cases, these landers are only designed to operate during a portion of the lunar day, with no provision for survival through the lunar night. By supporting lunar night survival, a mission can be extended through the lunar night and at least into another lunar day, thus turning a nominal eight-day mission into a 36-day mission. Therefore, the current system demonstration will focus on scalability to support at least 336 hours (one lunar night) of continuous thermal and electrical power generation. Although initially targeted to support lunar equatorial landings, the technology is extensible to missions at the lunar poles, other extreme environments in the Solar System or even air-independent applications on Earth (e.g., ocean exploration).

West, William↗

Integrated Heat Exchanger/Thermal Energy Storage System for CSP Plants

The research and development during the project focused on the design and optimization of an integrated heat exchanger/thermal energy storage (HX/TES) system, the charging and discharging performance of the developed HX/TES system, and the experimental investigation of lab-scale prototypes based on the full-scale system.

42 ENGINEERING↗