Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat resilience”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. In this work, the load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. The load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancing building resilience in cold climates: Integrating heat pump technologies with renewable energy

As electrification advances and Cold Climate Heat Pump technology progresses, ensuring grid stability becomes increasingly critical for effective heating in cold climates. However, natural disasters, especially during winter, pose significant threats to grid stability, impacting the reliability of air-source heat pumps. Despite these challenges, the integration of renewable energy sources and storage solutions in heating systems has not been extensively studied within the context of resilience. Here, this paper delves into the literature on renewable-powered heat pumps to assess their potential in enhancing building resilience in U.S. cold climate zones, which are particularly susceptible to extreme weather and grid disruptions. By leveraging renewable sources—solar, geothermal, and water—in conjunction with heat pump technology and supported by thermal or battery storage, this approach aims to provide a dependable solution for maintaining indoor heating during grid failures. Our analysis begins with a review of various renewable energy sources suitable for heat pumps, followed by an exploration of their application in cold climate regions across the U.S., and discussions on potential integration strategies with heat pump systems. This study highlights the advantages and suitability of solar irradiance and geothermal resources, emphasizing the importance of tailored, site-specific assessments to maximize energy efficiency and resilience. Additionally, it outlines the economic and environmental considerations necessary for implementing such systems and identifies potential challenges and areas for future research to facilitate the broader integration of renewable energy in heating solutions for enhanced resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma

This study builds on the existing techno economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system's resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system's heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Plant heat stress: Concepts directing future research

Predicted increases in future global temperatures require us to better understand the dimensions of heat stress experienced by plants. In this review we highlight four key areas for improving our approach towards understanding plant heat stress responses. First, although the term "heat stress" is broadly used, that term encompasses heat shock, heat wave, and warming experiments, which vary in the duration and magnitude of temperature increase imposed. A greater integration of results and tools across these approaches is needed to better understand how heat stress associated with global warming will affect plants. Secondly, there is a growing need to associate plant responses to tissue temperatures. We review how plant energy budgets determine tissue temperature and discuss the implications of using leaf versus air temperature for heat stress studies. Third, we need to better understand how heat stress affects reproduction, particularly understudied stages such as floral meristem initiation and development. Fourth, we emphasize the need to integrate heat-stress recovery into breeding programs to complement recent progress in improving plant heat-stress tolerance. Taken together, we provide insights into key research gaps in plant heat stress and provide suggestions on addressing these gaps to enhance heat stress resilience in plants.

54 ENVIRONMENTAL SCIENCES↗

Grid Resilient, Self-Powered, Fuel Flexible, High Efficiency Heating System (Final Report)

The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Stock Characterization in Palm Beach County, Florida

This building stock characterizations is intended to help Palm Beach County (PBC) Office of Resilience (OOR) and municipalities composing the Municipal Resilience Partnership prioritize building energy efficiency investments to reduce energy costs and increase resilience for the county's most vulnerable residents. The analysis utilizes NREL’s ResStock model to characterize PBC’s residential building stock, including building type, renter/owner status, size (square footage), age of buildings (vintage), HVAC system types, and, for multi-family buildings, number of units. Building energy efficiency, weatherization, and electrification upgrade packages were assessed for approximate cost, customer bill-savings, and emissions reductions potential and findings will help guide OOR financial assistance program design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of Cr and Ni concentrations on resilience of cast Nb- alloyed heat resistant austenitic steels at extreme high temperatures

Austenitic Cr–Ni alloyed heat resistant steels with Nb additions are used for intensively thermo-mechanically loaded cast components working in extreme high temperature oxidizing environment. Their performance during static oxidation and transient thermo-mechanical loading was investigated to recommend an optimal cost-effective Cr/Ni composition of Nb-alloyed austenitic class steels. Here, the static oxidation and transient thermo-mechanical behavior of three austenitic steels with different Cr/Ni alloying levels were investigated and compared for variety of working conditions. Static oxidation was performed between 900 °C and 1000 °C in air for 400 h. The critical temperature which increases spallation during static oxidation was determined for each of the steel alloying levels. In addition, thermal cycling of a constrained specimen was done with varying upper cycling temperatures between 850 °C and 1000 °C. SEM and TEM analyses were supported by thermodynamic simulation of the phases precipitated in the metal matrix and the structure of formed oxide layers. These studies were used to determine the mechanisms of degradation of thermo-mechanically loaded Cr/Ni austenitic steels at extreme high temperatures. A recommendation for a cost-effective Cr/Ni alloying level for different working conditions was determined.

36 MATERIALS SCIENCE↗

Where to cool off: a geospatial framework for placement of cooling centers

Indoor cooling is essential to reduce heat stress and increase passive survivability during heatwaves. Although air conditioning (AC) is recommended for maintaining indoor thermal comfort, low- and medium-income households in the U.S. often do not own an AC and/or limit AC usage to reduce energy consumption and associated costs, thereby risking their health and safety. With the frequency and intensity of heatwaves increasing, cooling centers are considered an appropriate alternative to indoor cooling and a possible mitigation strategy to prevent adverse health impacts of heat exposure. However, these centers are limited in numbers and not always accessible. This requires (i) developing a geospatial framework using physical and social factors for optimal siting of cooling centers to meet future needs and (ii) ranking of existing and potential cooling centers (schools, libraries, religious institutions) based on their accessibility among vulnerable populations and proximity to healthcare facilities. We developed and deployed a geospatial framework based on the Multi-criteria Decision Analysis approach in five U.S. cities (Los Angeles (LA), Phoenix, Austin, Atlanta, Miami) to evaluate the effectiveness of the framework in ranking cooling centers based on accessibility and population coverage. The results revealed that (i) access to cooling centers varies across cities and 32.2–50.7% of centers are within walking distance of the most vulnerable populations, (ii) vulnerable populations exposed to Urban Heat Island (UHI) effects are more likely to experience energy burden, and (iii) about 21.2–49.4% of population with high energy burden have access to these centers. Considering that more cooling centers are needed to assist energy burdened households alleviate heat exposure impacts, the framework developed herein could be adapted to incorporate other factors (e.g. health impacts, policies) to assess site suitability of existing shelters, identify potential sites for new cooling centers, and geo-target communities where energy efficient emerging technologies could be deployed to reduce heat stress.

58 GEOSCIENCES↗

LA100 Equity Strategies. Chapter 7: Housing Weatherization and Resilience

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and access to cooling as means to achieve more equitable resilience to heat waves during unplanned power outages. Specifically, NREL used weather, housing, and socioeconomic data to characterize LA's residential building stock. We?developed a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We then simulated and evaluated the impacts of 10 building envelope and cooling upgrades on indoor temperature - a main cause of heat-induced health risks-over a 4-day power outage during a heat wave. We examined occupant exposure to extreme heat and how heat exposure changes with each upgrade across income, tenure (renter/owner status), building type, and disadvantaged community (DAC) status. We also examined upgrade costs and utility bills. Based on the results of our analysis and community guidance, we identified building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for LA's low-income households in the event of a planned or unplanned power outage during a summer heat wave. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

building envelope↗

Multi-criteria thermal resilience certification scheme for indoor built environments during heat waves

With climate change, the indoor built environment is expected to significantly influence the occupant's safety and well-being. A novel multi-criteria thermal resilience certification scheme for indoor built environments during extreme heat events is proposed in this paper. The certification scheme considers overheating, thermal comfort, heat stress, and hygrothermal discomfort in built environments. These criteria are quantified using key performance indicators like indoor overheating degree, hours of exceedance, wet-bulb globe temperature, and heat index, respectively. This scheme is developed based on existing best practices like standards, rating systems, and literature. The scheme is implemented on a benchmark building energy performance model for detached post-World War II dwellings in Belgium as a case study using weather data measured from the City of Brussels. The indoor overheating in the reference dwelling is assessed with a static threshold of 27 °C for the bedrooms and adaptive thresholds for other areas. The analysis found that the building performance is within the defined threshold levels throughout the heat wave duration for all criteria. Therefore, the reference dwelling got a maximum attainable score of four points and is rated five-star for thermal resilience during heat waves. The proposed certification scheme is intended as a standardized framework and highlights the need for further revisions in building performance policies and guidelines.

Climate change↗