Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Dynamic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Three phase spectral interferometry for recording high dynamic range optical waveforms with <1 ps resolution over >2 ns records applied to closed-loop pulse shaping

Herein we demonstrate, to our knowledge, a novel spectral interferometry technique that simultaneously captures three spectral interferograms of a signal waveform with a reference pulse. The measured performance is robust to nonidealities and ambient drifts by implementing a precisely calibrated 3 × 3 polarization maintaining (PM) splitter that provides three phase shift differences nominally spaced 120° apart. The system can achieve long record length by implementing three, high resolution, virtually imaged phase array (VIPA) spectrometers. Here, we experimentally implement this technique and demonstrate the measurement of waveforms with >2ns of record while maintaining <1ps resolution.

42 ENGINEERING↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

Improving Signal to Noise Ratios in Ion Mobility Spectrometry and Structures for Lossless Ion Manipulations (SLIM) using a High Dynamic Range Analog-to-Digital Converter

Signal digitization is a commonly overlooked part of ion mobility-mass spectrometry (IMS-MS) workflows, yet it is a significant contributor for determining signal-to-noise ratios and MS resolution. Here we report on the integration of a 2 GS/s, 14-bit ADC with a structures for lossless ion manipulations (SLIM)-IMS-MS and compare the performance to a commonly used 8-bit ADC. The 14-bit ADC provided an effective reduction in digitized noise by factor of ~6, owing largely to the use of smaller bit sizes. The low baseline allowed the threshold voltage levels to be set very close to the MCP baseline voltage, allowing for as much signal to be acquired as possible without causing overloading or excessive digitization of MCP baseline noise. Analyses of Agilent tuning mixture ions and a complex mixture of heavy labeled phosphopeptides showed that the 14-bit ADC (compared to the 8-bit ADC) provided a modest signal-to-noise increase (~1.5 to 2-fold) for high intensity ions, such as the Agilent tuning mixture ions and the 2+ and 3+ charge states of many phosphopeptide constituents. However, signal enhancements were as much as 10-fold for low intensity ions, and the 14-bit ADC enabled discernable signal intensities otherwise lost using an 8-bit digitizer. Additionally, the 14-bit ADC required ~14-fold fewer mass spectra to be averaged to produce a mass spectrum with similar S/N as the 8-bit ADC under identical conditions, potentially providing an order of magnitude higher measurement throughput. The high resolution, low baseline, and fast speed of the new 14-bit ADC enables high performance digitization of MS, IMS-MS, and SLIM-IMS-MS spectra, and allows a much fuller picture of analyte profiles in complex mixtures to be acquired.

data acquisition, digitization, ion mobility spect↗

Burn mode signatures enabled by high dynamic range fusion reaction history

The evolution of the fusion burn of a compressed inertial confinement fusion (ICF) implosion gives information about the evolution of the temperature, mass, and volume of the hot spot. Currently, the fusion reaction history has been measured with about a decade of dynamic range, giving information about just the peak of the fusion burn. There are proposals for extending the dynamic range to 1000×, measuring the rising edge of the burn earlier in time. Using fusion hot spot theory and a set of ICF simulations, we identify and categorize different stages of fusion burn and what signatures could be measured. For ice layered implosions, the details, conditions, and dynamics of the fusion burn propagation could be observed. For double shell and OMEGA scale implosions, the evolution of the final compression and rebounding shock before ignition could be observed. Higher dynamic range expands investigation into the logarithmic derivative, α, as a signature of various mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Dynamic Range AFM Cantilever With a Collocated Piezoelectric Actuator-Sensor Pair

We present a novel approach to fundamentally eliminate electrical feedthrough (cross-talk) signal in self-sensing piezoelectric microcantilevers, used in dynamic mode atomic force microscopy (AFM). The probe is an Si microcantilever on which a two-layer piezoelectric stack transducer is microfabricated. The top transducer in the stack functions as an actuator, while the bottom transducer is used as a deflection sensor. This arrangement leads to a collocated actuator-sensor pair that co-exist on the same surface area. We report experimental results that establish the sensor's ability to capture the full dynamic range of the cantilever with minimal feedthrough from the actuator.

42 ENGINEERING↗

High framerate and high dynamic range electron microscopy

Methods and systems for acquiring transmission electron microscope video data on a rolling-shutter detector at an enhanced frame rate and without temporal distortions are described. Also described are methods to enhance the dynamic range of image and diffraction data acquired using a transmission electron microscope. The disclosed methods and systems may also be applicable to photon detection and imaging systems.

Bloom, Ruth↗

Quasi-Dynamic Electromagnetic Field Safety Analysis and Mitigation for High-Power Dynamic Wireless Charging of Electric Vehicles

Dynamic wireless charging of electric vehicles (EV) is an emerging charging technology to enable non-contact wireless charging while the vehicle is moving. Compared to stationary wireless charging, in-motion wireless charging involves dynamic processes in which an EV is passing over the charging pads (transmitters). This in motion process makes the dynamic electromagnetic (EM) environment more complicated, and EM safety needs to be ensured under all circumstances. This is due to the fact that the entire vehicle body may be exposed to magnetic fields while the vehicle moves over the energized transmitter. This paper investigates several typical charging scenarios when EVs approach, pass over, and move away from the charging pads. Quasi-dynamic models, which are preliminarily verified by coils’ inductance measurements, are developed to analyze the dynamic process. Based on the quasi-dynamic analysis, shielding solutions are also studied to ensure EM safety for the dynamic wireless charging processes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Revealing High-Temperature Reduction Dynamics of High-Entropy Alloy Nanoparticles via In Situ Transmission Electron Microscopy

Understanding the behavior of high-entropy alloy (HEA) materials under hydrogen (H 2 ) environment is of utmost importance for their promising applications in structural materials, catalysis, and energy-related reactions. Herein, the reduction behavior of oxidized FeCoNiCuPt HEA nanoparticles (NPs) in atmospheric pressure H-2 environment was investigated by in situ gas-cell transmission electron microscopy (TEM). The reduction reaction front was maintained at the external surface of the oxide. During reduction, the oxide layer expanded and transformed into porous structures where oxidized Cu was fully reduced to Cu NPs while Fe, Co, and Ni remained in the oxidized form. In situ chemical analysis showed that the expansion of the oxide layer resulted from the outward diffusion flux of all transition metals (Fe, Co, Ni, Cu). Revealing the H-2 reduction behavior of HEA NPs facilitates the development of advanced multicomponent alloys for applications targeting H 2 formation and storage, catalytic hydrogenation, and corrosion removal.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Embedded Fiber Bragg Grating (FBG) Sensors Fabricated by Ultrasonic Additive Manufacturing for High-Frequency Dynamic Strain Measurements

This article demonstrates high-frequency dynamic strain measurements using fiber Bragg grating (FBG) sensors embedded in metal parts. Using an ultrasonic additive manufacturing (UAM) process, FBGs inscribed in polyimide coated optical fibers were embedded in aluminum parts. An electromagnetic shaker was used to exert dynamic events on the embedded FBG sensors with frequencies from 1 to 10 kHz. The high-speed interrogation of FBG sensors was accomplished using a tunable vertical-cavity surface-emitting laser (VCSEL) and a high-speed interrogation system sampling at 120 kHz. The strain response measured by the FBG sensors was compared with real-time measurements using a laser velocimeter. A finite-element analysis (FEA) was performed to simulate responses to both static strain and high-frequency dynamic strain. In conclusion, results show that strains as small as 2.5$με$ can be resolved at frequencies up to 10 kHz.

36 MATERIALS SCIENCE↗

Data of High-Temperature Dynamic LCM Testing Setup

Data from high temperature dynamic sealing tests for various fracture widths, at various temperatures (degrees F), with 5 wt.% bentonite-based mud containing various material fiber contents, at 100 to 400 psi differential pressure. Data from pressure test and evaluation of the dynamic lost circulation materials (LCM) testing unit to reflect the condition of open and sealed fracture using fracture width of 1000 microns at 120 degrees F. Links to two papers based on the data - "Loss circulation prevention in geothermal drilling by shape memory polymer" which was published in Geothermics 89 (2021) 101943) as well as "Evaluating sealability of blended smart polymer and fiber additive for geothermal drilling with the effect of fracture opening size", published in the Journal of Petroleum Science and Engineering 206 (2021) 108998.

15 GEOTHERMAL ENERGY↗

Readout for Calorimetry at Future Colliders: A Snowmass 2021 White Paper

Calorimeters will provide critical measurements at future collider detectors. As the traditional challenge of high dynamic range, high precision, and high readout rates for signal amplitudes is compounded by increasing granularity and precision timing the readout systems will become increasingly complex. This white paper reviews the challenges and opportunities in calorimeter readout at future collider detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ab initio electron dynamics in high electric fields: Accurate prediction of velocity-field curves

Electron dynamics in external electric fields governs the behavior of solid-state electronic devices. First-principles calculations enable precise predictions of charge transport in low electric fields. However, studies of high-field electron dynamics remain elusive due to a lack of accurate and broadly applicable methods. In this work, we develop an efficient approach to solve the real-time Boltzmann transport equation with both the electric field term and ab initio electron-phonon collisions. These simulations provide field-dependent electronic distributions in the time domain, allowing us to investigate both transient and steady-state transport in electric fields ranging from low to high (> 10 kV/cm). The broad capabilities of our approach are shown by computing nonequilibrium electron occupations and velocity-field curves in Si, GaAs, and graphene, obtaining results in quantitative agreement with experiment. Our approach sheds light on microscopic details of transport in high electric fields, including the dominant scattering mechanisms and valley occupation dynamics. Our results demonstrate quantitatively accurate calculations of electron dynamics in low to high electric fields, with broad application to power and micro-electronics, optoelectronics, and sensing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Online data-driven changepoint detection for high-dimensional dynamical systems

In this study, the detection of anomalies or transitions in complex dynamical systems is of critical importance to various applications. In this study, we propose the use of machine learning to detect changepoints for high-dimensional dynamical systems. Here, changepoints indicate instances in time when the underlying dynamical system has a fundamentally different characteristic—which may be due to a change in the model parameters or due to intermittent phenomena arising from the same model. We propose two complementary approaches to achieve this, with the first devised using arguments from probabilistic unsupervised learning and the latter devised using supervised deep learning. To accelerate the deployment of transition detection algorithms in high-dimensional dynamical systems, we introduce dimensionality reduction techniques. Our experiments demonstrate that transitions can be detected efficiently, in real-time, for the two-dimensional forced Kolmogorov flow and the Rössler dynamical system, which are characterized by anomalous regimes in phase space where dynamics are perturbed off the attractor at potentially uneven intervals. Finally, we also demonstrate how variations in the frequency of detected changepoints may be utilized to detect a significant modification to the underlying model parameters by utilizing the Lorenz-63 dynamical system.

97 MATHEMATICS AND COMPUTING↗

Expanding Scientific Horizons Through High Field Dynamic Nuclear Polarization with Advanced Organic BiRadicals

This project aimed to advance the capabilities of high-field Dynamic Nuclear Polarization (DNP) Nuclear Magnetic Resonance (NMR) spectroscopy at 800 MHz through the synthesis and evaluation of novel biradicals. While the targeted HyTEK biradical synthesis faced significant challenges, alternative efforts focused on synthesizing intermediate compounds and exploring alternative biradicals. A portion of the BDPA precursor was successfully converted into BDPA-TEMPO, though further DNP testing could not be completed within the project timeline. Benchmarking experiments with existing biradicals, including TEKPol and M-TinyPol, were conducted to evaluate their performance under high-field conditions. These efforts provided valuable insights into DNP enhancements, refined operational protocols for high-field experiments, and established benchmarks for future polarizing agent development.

36 MATERIALS SCIENCE↗