CoLoRe-2LPT: Lyman-$α$ mock catalogues for the validation of DESI cosmological analyses

The Lyman-$α$ (Ly$α$) forest has become a crucial probe for studying the large-scale structure of the universe at high redshift ($z > 2$), providing powerful constraints on Baryon Acoustic Oscillations (BAO) and the full-shape (FS) clustering of matter. As a key ingredient for upcoming BAO and FS analyses, we present a new generation of fast cosmological Ly$α$ mocks based on second-order Lagrangian perturbation theory (2LPT). These new mocks significantly improve upon previous log-normal approaches, both at accurately capturing small scale clustering and at recovering the non-linear broadening of the BAO peak. They are able to reproduce Ly$α$ statistics within $10\%$ of the latest DESI measurement; including the Ly$α$ bias and the redshift-space distortion $β$ parameter, mean transmitted flux, and 1D power spectrum. The corresponding quasar (QSO) clustering is also improved with respect to previous approaches, calibrated against high-resolution Abacus simulations, recovering the observational QSO linear bias to less than $5\%$ and improving redshift-space distortions via 2LPT velocities and the addition of Fingers-of-God effects. Furthermore, these mocks incorporate high column density systems and metal lines, allowing us to explore the effects and systematics induced by these astrophysical contaminants. This new set of mocks has been key for enhancing the modeling and validation of the DESI DR2 Ly$α$ full shape cosmological analysis. This work provides a physically motivated and computationally efficient tool for simulating current and next-generation Ly$α$ surveys and validating FS and BAO analysis.

Bernal, M.F. Ruiz-Herrera [Madrid, CIEMAT] (ORCID:↗

Accuracy and Resolution Evaluation of the E-Beam Profile Scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges. For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a phosphor screen and an optical transition radiation (OTR) screen. The capabilities of the Kimball Physics electron gun (eGun) will be considered for accuracy. Additionally, the Zemax software will be utilized to characterize the optical elements.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗

Risk-Aware Measurement Synchronization and Recovery for DSSE With Heterogeneous Data Sources

Power distribution systems are increasingly integrating heterogeneous sensors with varying data reporting rates and types, which pose challenges to achieving observability at the desired temporal resolution of distribution system state estimation (DSSE). Multisensor failures caused by extreme events exacerbate these issues, introducing substantial uncertainties into DSSE. This article proposes a novel solution to these challenges by ensuring high-resolution system observability despite heterogeneous data sources and multisensor failures. First, a deep learning architecture combining long short-term memory (LSTM) and graph convolutional network (GCN) is employed to synchronize meters with different reporting rates, aiming to achieve system observability. A random-walk-model-based approach is introduced to generate pseudo-measurements while properly characterizing their uncertainties under multisensor failures. Finally, a disaster-risk-informed observability metric (RiOM) is defined to quantify the uncertainty associated with state estimation results. The proposed framework offers deeper insights into the system observability on the fly compared with conventional analysis. The effectiveness of the framework is demonstrated on an IEEE standard test case and a large-scale real-world distribution feeder in mid-Minnesota in the U.S.

97 MATHEMATICS AND COMPUTING↗

The Role of Defect Geometry in Localized Emission from Monolayer Tungsten Dichalcogenides

In two-dimensional transition metal dichalcogenides such as tungsten diselenide (WSe 2 ), single photon emission has been broadly attributed to exciton localization from atomic point defects, yet the precise microscopic origins are unclear. This work introduces an empirically grounded computational framework that explains the origins of facile single photon emission in WSe 2 . High-resolution microscopy identifies native defect geometries in monolayer WSe 2 lattices from which the model is built. Here, the qualitative effects of chalcogen type, defect geometry, and mechanical strain on the electronic structure are individually assessed using density functional theory, and a specific divacancy configuration emerges as the candidate for localized single-electron transitions that match observed spectral energies. Spectroscopy and photon correlation measurements further validate this model, establishing a self-consistent link between defect geometry, electronic structure, and quantum emission.

defect emission↗

Performance of the Particle-Identification Silicon-Telescope Array coupled with the VAMOS++ magnetic spectrometer

The Particle-Identification Silicon-Telescope Array (PISTA) is a new detection system designed for high-resolution studies of fission process induced by multi-nucleon transfer in inverse kinematics. It is specifically optimized for experiments with the VAMOS++ magnetic spectrometer at GANIL (Grand Accélérateur National d’Ions Lourds). The array comprises eight trapezoidal ΔE-E silicon telescopes arranged in a lamp shade configuration. Each telescope integrates two single-sided stripped silicon detectors, enabling target-like recoil identification, energy loss measurements, and trajectory reconstruction. Positioned in close proximity to the target, PISTA’s compact geometry achieves high-efficiency tracking of target-like recoils produced in multi-nucleon transfer reactions at Coulomb barrier energies. The spatial segmentation of the array allows precise determination of the mass and charge of the target-like nucleus, and excitation energy of fissioning systems. This work presents the particle identification and excitation energy reconstruction performances for the interactions of 238 U beam with 12 C target. An excitation energy resolution of 800 keV (FWHM) was determined together with mass resolution of 1.1% (FWHM). The combination of PISTA and VAMOS++ magnetic spectrometer enables unprecedented investigations of the fission process as a function of the excitation energy of the fissioning nucleus, particularly for exotic systems produced in transfer-induced reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rolling Root Mean Square Based Multimodal Anomaly Detection for Real Time Monitoring of Smart Grid

Reliable real-time monitoring is valuable for maintaining the operational integrity of modern electrical smart grids. Deployment of heterogeneous sensing technologies in substations has enabled high-resolution, multichannel waveform monitoring, but also introduces challenges for anomaly detection due to noise, baseline drift, and modality-dependent signal characteristics. In this work, we present a computationally efficient unsupervised method for multimodal event detection based on Rolling Root Mean Square based Event Detection (RRMSED). The method is developed using in-house, field deployed sensors collecting data at a utility substation. The sensing system comprises voltage and current sensors, triaxial accelerometers, and magnetometers, collectively capturing electrical, vibrational, and magnetic waveform measurements at high temporal resolution. RRMSED operates by extracting rolling RMS energy features and their first-order temporal differences from consecutive waveform segments for each channel and then applying channel-specific statistical thresholds learned from historical data. A persistence-based exceedance logic is employed to robustly identify transient events while suppressing impulsive noise, and to provide precise temporal localization with high resolution. The framework is designed for continuous server-side operation and can be deployed in real time without requiring complex models. Experiments on simulated waveform data with known ground truth demonstrate low false positive (FP) and false negative (FN) rates. Application to real substation data shows RRMSED to identify events that are not captured by conventional monitoring indicators including fast transient detection algorithm currently deployed in the system. These results indicate that rolling RMS based features provide an effective and practical basis for real-time multimodal event detection in smart-grid substations.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Delving into the depths of NGC 3783 with XRISM V. Broad-band modelling of ionized outflows

The Seyfert 1 galaxy NGC 3783 hosts a multi-phase warm absorber (WA) that has been extensively studied in the X-ray band. High-resolution spectra from 2000−2001 revealed a complex outflow with multiple ionization and velocity components. Two decades later, new XMM-Newton and XRISM observations allow us to investigate the long-term evolution of these outflows. We performed joint spectral modelling of the XMM-Newton /RGS and XRISM/Resolve time-averaged spectra using the pion photoionization code within SPEX. We derived the ionization parameter, column density, turbulent velocity, and outflow velocity for each absorption component, and investigated their thermal stability and absorption measure distribution (AMD) to characterize the physical and dynamical properties of the WA in NGC 3783 in 2024. We compared these results with the 2000−2001 epoch to assess long-term variability, stability, and possible changes in the absorber population. We identify eight WA components spanning log ξ = 1.08 − 3.38 and outflow velocities of 480−1230 km s −1 . The ranges of column densities and turbulent velocities remain broadly consistent with the WAs from 2000−2001, but the earlier data contained more low-ionization, high-velocity components. The total column density of all the outflows in 2024 is 1.5 times larger than in 2000−2001, which means that it has been replenished by fresh material. The dominant unresolved transition array (UTA) absorber (component B3) has increased its column density by a factor of three while maintaining a similar ionization parameter. The WAs in NGC 3783 have undergone significant structural and dynamical evolution over the past 24 years.

79 ASTRONOMY AND ASTROPHYSICS↗

Integration of GOES Data for Solar Resource Assessment of the Contiguous United States

The National Solar Radiation Database (NSRDB), produced by the National Laboratory of the Rockies (NLR), provides high-resolution solar resource data for the contiguous United States (CONUS) using Geostationary Operational Environmental Satellite (GOES) East and West observations. This study evaluates the integration of multi-satellite data within the GOES-East/West overlap regions, where conventional longitude-based selection methods often produce an artificial boundary seam. Our results demonstrate that an advanced blending algorithm, which incorporates sun-satellite scattering angles and satellite viewing zenith angles, improves NSRDB accuracy and creates a spatially continuous dataset. Validation against ground-based irradiance measurements reveals reductions in both percentage error (PE) and normalized Root Mean Square Error (nRMSE), particularly in the central United States. The dynamical integration of multi-satellite data provides a robust foundation for more precise modeling of solar resource and improved spatiotemporal analysis of solar ramp across the CONUS.

14 SOLAR ENERGY↗

Defect-Limited Carrier Lifetime in Epitaxially Strained Germanium-On-Silicon Heterostructures

Epitaxially strained germanium-on-silicon (Ge-on-Si) heterostructures are central to next-generation photonic and electronic devices, yet their performance remains strongly constrained by defect-limited carrier lifetimes. In this work, we investigate the impact of defects on the carrier lifetime in relaxed Ge-on-Si and strained Ge-on-Si heterostructures. High-resolution X-ray diffraction quantifies the strain-state in Ge and reveals signatures of strain relaxation due to lattice mismatch. Cross-sectional and plan-view transmission electron microscopy analyses enable direct visualization of interfacial defects and quantification of threading dislocation densities (TDDs) within the Ge layer. However, the presence of a dense misfit dislocation network obscures the threading dislocation signatures, preventing reliable TDD determination by plan-view transmission electron microscopy in strained-Ge (..epsilon..-Ge). To assess the defect density in this case, etch-pit density measurements were performed, providing an alternative means of quantifying the TDDs in the ..epsilon..-Ge layer. Carrier lifetime measurements by microwave-reflection photoconductive decay reveal a clear relationship with TDDs ranging from 5 x 103 cm-2 to 2 x 1010 cm-2, confirming Shockley-Read-Hall recombination as the limiting mechanism at lower defect densities, with TDD-dominated recombination at higher defect densities. The Ge-on-Si relaxed heterostructure exhibited lifetimes much lower (~12 ns) than the lattice-matched Ge on gallium arsenide (GaAs) (~158 ns) heterostructure. Introducing controlled tensile strain reduces defect formation, suppresses strain-relaxation pathways, and leads to measurable improvements in minority carrier lifetime from 12 ns to 171 ns. These results establish a direct relation between defect suppression and carrier recombination dynamics in both relaxed Ge-on-Si grown directly on Si and strained Ge-on-Si heterostructures incorporating compound-semiconductor buffer layers, offering a materials-driven pathway for engineering Ge with improved carrier lifetime for photonic applications.

36 MATERIALS SCIENCE↗

Artificial Intelligence-Driven Management of Sustainable Energy Resources: Visibility, Operation, and Control

The rapid global transition toward sustainable energy resources (SERs) is reshaping how modern power systems are observed, optimized, and controlled. While SERs have significantly advanced decarbonization, their weather dependence, variability, and inverter-dominated characteristics challenge traditional, centralized, and deterministic grid operation. At the same time, the proliferation of high-resolution data from inverters, smart meters, and sensors offers unprecedented visibility into system dynamics. Yet, it also exceeds the analytical capability of conventional model-based approaches. Artificial intelligence (AI) provides a new foundation for addressing these challenges by bridging physical laws with data-driven learning, enabling accurate state awareness, adaptive operation, and coordinated control across distributed assets. This article examines how AI transforms the management of SER-rich power systems along three critical dimensions: 1) enhancing visibility by inferring behind-the-meter (BTM) activities, assessing SER flexibility, and reconstructing system states from sparse or noisy measurements; 2) improving operation through AI-enhanced SER service provision, volt/var control (VVC), and dynamic operating envelopes (DOE) for efficiency and security; and 3) advancing control by embedding learning-based intelligence into inverter coordination, voltage and frequency regulation, and long-term dispatch. Together, these developments reveal how AI can convert the variability of SERs from an operational challenge into a source of flexibility, resilience, and intelligence, paving the way toward sustainable, adaptive, and self-optimizing power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal cycling-driven microstructural changes of eutectic Al–Si phase change materials in SS304 containers revealed by multi-modal imaging

Aluminum-based Al–Si alloys are widely used as phase change materials (PCMs) in thermal energy storage (TES) systems owing to their high volumetric latent heat and superior thermal conductivity. However, their long-term reliability is limited by degradation processes that remain insufficiently understood. In this work, we employ a multimodal, correlative characterization framework to systematically resolve the degradation behavior of eutectic Al–Si PCMs in contact with SS304 containers under repeated thermal cycling. By integrating high-resolution electron microscopy, three-dimensional X-ray fluorescence (3D XRF) imaging, and differential scanning calorimetry (DSC), we directly link spatially resolved compositional and microstructural evolution to changes in thermophysical properties. The correlative analysis reveals that elemental leaching of Fe, Cr, and Ni from the stainless-steel container into the PCM drives the formation of intermetallic compounds (IMCs) both at the interface and within the bulk PCM, leading to pronounced compositional heterogeneity. These interfacial reactions and diffusion-induced transformations progressively destabilize the Al–Si eutectic, reducing the effective phase-transforming fraction. Consistent with these observations, DSC measurements show a decrease in melting temperature and latent heat of fusion with thermal cycling. These results underscore the critical influence of interfacial reactions and material compatibility on the stability, durability, and overall performance of Al–Si-based TES systems.

25 ENERGY STORAGE↗

Silicon-On-Sapphire Metasurfaces Generate Arrays of Dark and Bright Traps for Neutral Atoms

We demonstrated crystalline silicon-on-sapphire (c-SOS) metasurfaces that convert a Gaussian beam into arrays of complex optical traps, including arrays of optical bottle beams that trap atoms in dark regions interleaved with bright tweezer arrays. The high refractive index and indirect band gap of crystalline silicon make it possible to design high-resolution near-infrared (λ > 700 nm) metasurfaces that can be manufactured at scale using CMOS-compatible processes. Compared with active components like spatial light modulators (SLMs) that have become widely used to generate trap arrays, metasurfaces provide an indefinitely scalable number of pixels, enabling large arrays of complex traps in a very small form factor, as well as reduced dynamic noise. To design metasurfaces that can generate three-dimensional bottle beams to serve as dark traps, we modified the Gerchberg-Saxton algorithm to enforce complex-amplitude profiles at the focal plane of the metasurface and to optimize the uniformity of the traps across the array. We fabricated and measured c-SOS metasurfaces that convert a Gaussian laser beam into arrays of bright traps, dark traps, and interleaved bright/dark traps.

Gerchberg-Saxton↗

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds↗

Shear-free, inhomogeneous turbulence in a stably stratified fluid

High-resolution large eddy simulations are conducted of locally forced, shear-free turbulence in the presence of an initially sharp density interface. The simulations are reminiscent of oscillating grid turbulence experiments used to isolate the effect of turbulent diffusion and entrainment from background shear. By simulating such a flow we avoid common challenges of the experiments such as secondary-flow contamination due to sidewall effects and the inevitable interaction of the stratifying agent and forcing region. To address the latter concern, we add a heating term (potential energy sink) to the governing equations in the forcing layer, thereby preventing a heat flux through the source region. This modification sets up a continuous stratification in the mixed layer that is often assumed to be negligible in experiments. Despite this difference, we are able to make meaningful comparisons in terms of the overall entrainment rate, which varies as a power law with a turbulent Richardson number. Two exponents, −2 and −1, are measured depending on the definition of the Richardson number and entrainment rate used. The definition leading to −1 is consistent with most experiments, and we argue it is the superior choice if one is able to measure the relevant quantities. We also verify the self-similar scaling of turbulence velocity and length scales in the homogeneous fluid and propose ‘inner’ and ‘outer’ scalings for the stratified cases based on a local Froude number. The detailed scaling results are useful for turbulence model validation.

54 ENVIRONMENTAL SCIENCES↗

Photon calibration techniques for high resolution cryogenic detectors

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector’s resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector’s performance will violate these assumptions, biasing the calibration. Lastly, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.