An Overview of Non-LWR Vessel Cooling Systems for Passive Decay Heat Removal (Technical Letter Final Report)

The following report provides a technical review of various reactor vessel cooling system (VCS) concepts under consideration for decay heat removal (DHR) in non-light water advanced reactor designs. This review focuses on ex-vessel designs, including the Reactor Cavity Cooling System (RCCS), the Reactor Vessel Auxiliary Cooling System (RVACS), and hybrid iterations, using both air and water cooling to achieve their heat removal function. Based on a literature review of publicly available sources published between 1979 and 2021, a technical summary is presented detailing existing and planned VCS design options, their applicability to specific reactor type, and review of authored research and development studies. Following an assessment of the availability of data and modeling tools, an evaluation was performed analyzing their likely performance during normal, degraded, and accident conditions, including reliability, stability, and longevity. With renewed consideration of air-based DHR systems by some US vendors, there is a need to fully understand the complexities inherent to natural circulation systems, and more importantly, how they may influence safety-related heat removal functions and system performance. For DHR systems that rely on air-based mode of cooling, this entails quantification of the impacts of low flow conditions during start-up, relative elevations of inlet and outlet ducts for below-grade installations, effects of the use of multiple parallel chimneys for redundancy, and impact of weather conditions at the plant site. For systems relying on water-based mode cooling, reliance on limited coolant inventory in an event of pipe break or extended duration accident scenarios, sensitivities related to stability of boiling flow and heat transfer conditions, and quantification of full-scale structural vibrations on balance of plant structures are among the complicating factors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗

Trends in best-in-class energy-efficient technologies for room air conditioners

Improving the efficiency of room air conditioners (RACs) could provide significant energy and associated emissions savings, particularly in emerging economies with hot climates where the cooling demand is expected to increase dramatically. To help accelerate efficiency improvements, this study identifies “best-in-class” high-efficiency RAC components and products. The findings show that manufacturers tend to minimize manufacturing costs by using RAC designs that are readily available or standardized to their production, and they share components across various models. High-efficiency RAC models use advanced compressor technologies optimized at a low frequency, large heat exchangers with thermodynamically effective materials and designs, highly efficient direct current fan motors, advanced metering devices, and smart sensors for temperature and humidity control. Recently RAC manufacturers have been improving seasonal efficiency – better reflecting part-load operation – especially via variable-speed (inverter) drives for compressor motors. Recent highest-efficiency RAC models use low global warming potential (GWP) refrigerants, having transitioned from conventional high-GWP refrigerants, in regions where RACs that use these low-GWP refrigerants are commercially available. Recently demonstrated innovative technologies show trends toward smart hybrid designs, evaporative cooling, and solid-state materials beyond the conventional vapor-compression technology. This information could help policymakers improve their RAC market-transformation programs to align with the most-efficient global technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryogenic C-band wavelength division multiplexing system using an AIM Photonics Foundry process design kit

Cryogenic environments make superconducting computing possible by reducing thermal noise, electrical resistance and heat dissipation. Heat generated by the electronics and thermal conductivity of electrical transmission lines to the outside world constitute two main sources of thermal load in such systems. As a result, higher data rates require additional transmission lines which come at an increasingly higher cooling power cost. Hybrid or monolithic integration of silicon photonics with the electronics can be the key to higher data rates and lower power costs in these systems. We present a 4-channel wavelength division multiplexing photonic integrated circuit (PIC) built from modulators in the AIM Photonics process development kit (PDK) that operate at 25 Gbps at room temperature and 10 Gbps at 40 K. We further demonstrate 2-channel operation for 20 Gbps aggregate data rate at 40 K using two different modulators/wavelengths, with the potential for higher aggregate bit rates by utilizing additional channels.

42 ENGINEERING↗

Impact of late-time neutrino emission on the diffuse supernova neutrino background

In the absence of high-statistics supernova neutrino measurements, estimates of the diffuse supernova neutrino background (DSNB) hinge on the precision of simulations of core-collapse supernovae. Understanding the cooling phase of protoneutron star (PNS) evolution (≳ 1 s after core bounce) is crucial, since approximately 50% of the energy liberated by neutrinos is emitted during the cooling phase. We model the cooling phase with a hybrid method by combining the neutrino emission predicted by 3D hydrodynamic simulations with several cooling-phase estimates, including a novel two-parameter correlation depending on the final baryonic PNS mass and the time of shock revival. We find that the predicted DSNB event rate at Super-Kamiokande can vary by a factor of ~2–3 depending on the cooling-phase treatment. Here we also find that except for one cooling estimate, the range in predicted DSNB events is largely driven by the uncertainty in the neutrino mean energy. With a good understanding of the late-time neutrino emission, more precise DSNB estimates can be made for the next generation of DSNB searches.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High performance heat exchangers for next generation hybrid cooler (CRADA Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use Cases and Model Development of Thermal Storage Coupling for Advanced Nuclear Reactors

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (ALWR) and a high-temperature gas-cooled reactor (HTGR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. Cost functions for the A-LWR were derived from the fully balanced models that were developed based on three different coupling options with three different thermal energy bypass ratios. For the next steps, cost functions for the HTGR will also be derived, and additional nuclear reactors (e.g., a liquid-cooled fast reactor [LFR] or molten-salt reactor [MSR]) will be evaluated for coupling with TES in similar fashion, including the evaluation of their steady-state condition models and cost functions. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state operation with minimum disruption to the nuclear power generation cycle. This report presents the results of steady state models developed using Aspen HYSYS®, wherein the thermal energy bypass for an NPP-TES coupling was varied up to 50%. The various components were sized using Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The current steady-state models and cost functions provide a baseline for additional work focusing on dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools to evaluate the technoeconomic viability and transient operations of TES-coupled A-NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High performance heat exchangers for next generation hybrid cooler (CRADA NFE-19-07891 Final Report)

The evaporative cooling process has been successfully deployed in multiple energy conversion processes such as power generation, process cooling, heating, ventilation & cooling (HVAC), and commercial and industrial refrigeration. The heat exchanger is a very common yet extremely critical component of such systems. The device is important since the performance of the overall cooling system heavily relies on the thermal-hydraulic efficiency of the heat exchanger. The possible wet operation as evaporative cooling heat exchanger complicates the issue. Indeed, based on the hybrid nature of operation (fully dry, partially wet, fully wet) the efficiency can vary significantly and can cause performance variation for the whole system. Understanding the importance of the issue, Oak Ridge National Laboratory (Contractor) and Baltimore Aircoil Company (Participant) propose an activity focused on the analysis of the existing heat exchanger technology used in air and evaporative cooling processes and design, development and demonstration of a novel heat exchanger design based on porous materials. The potential candidates include metallic wire meshes and metal foams carefully designed for the proposed application. Prior research has indicated that these materials have great potential for deployment in thermal systems, particularly heat sinks and heat exchangers. It is expected that the successful completion of the project will lead to novel heat exchanger technology for hybrid systems (capable of dry and wet operation) by exploring newly emerging materials and their potential for heat transfer application. The overall goal is to develop a next generation heat exchanger technology which can be deployed in evaporative cooling systems. The impact of the such development is significant since, it will not only make the overall system highly efficient but will also, reduce the total refrigerant charge in the heat exchanger, a critical aspect for the deployment of refrigerants with lower Global Warming Potential (GWP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Trajectory of Additively Manufactured Titanium Alloys with Superior Mechanical Properties and Engineered Microstructures

Additive manufacturing (AM) plays a crucial role in the manufacturing and development of advanced materials including titanium alloys for engineering applications. During the last two decades, a great deal of effort has been devoted to print titanium parts with desired properties. However, due to presence of non-equilibrium/metastable phases, anisotropic microstructure, and various porosities in the printed titanium alloys, achieving an excellent combination of mechanical properties has been challenging. Here this review paper aims to provide a comprehensive overview of multiple post-process and in-process approaches to achieve enhanced strength-ductility combinations by microstructure engineering. Approaches such as addition of alloying elements/nucleants, multi-step post heat treatment, in-situ heat treatment, forced inter-pass cooling, in situ peening/rolling, hybridizing microstructure, high-intensity acoustic vibration, thermo-hydrogen refinement of microstructure, deliberately introducing lack of fusion defects with subsequent hot isostatic pressing are discussed in detail. Finally, we conclude by highlighting the challenges associated with each method and potential areas of improvement that can pave the way to develop reliable components with enhanced performance.

36 MATERIALS SCIENCE↗

Coupling Two Laser-Cooled Ions via a Room-Temperature Conductor

We demonstrate coupling between the motions of two independently trapped ions with a separation distance of 620 μm. Here, the ion-ion interaction is enhanced via a room-temperature electrically floating metallic wire which connects two surface traps. Tuning the motion of both ions into resonance, we show flow of energy with a coupling rate of 11 Hz. Quantum-coherent coupling is hindered by strong surface electric-field noise in our device. Our ion-wire-ion system demonstrates that room-temperature conductors can be used to mediate and tune interactions between independently trapped charges over distances beyond those achievable with free-space dipole-dipole coupling. This technology may be used to sympathetically cool or entangle remotely trapped charges and enable coupling between disparate physical systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A hybrid surrogate modeling framework for the Digital Twin of a Fluoride-salt-cooled High-temperature Reactor (FHR)

While nuclear energy is a non-greenhouse-gas emitting energy source, expensive operational costs due to the high-level of safety requirements decreases their competitiveness in the sustainable energy market. Advanced reactor concepts paired with Digital Twins aim to increase the commercialization gains of nuclear energy by reducing operational costs, increasing reactor reliability and enhancing power generation. To support Digital Twin tasks such as real-time autonomous control, proactive maintenance monitoring or optimizing power demand operations, a fast and accurate virtual representation of the Nuclear Power Plant (NPP) is required. The computational cost of high-fidelity, physics-based models are unsuitable for real-time analysis or scalability. Here, in this work, a hybrid surrogate modeling framework is developed fora Fluoride-salt-cooled High-temperature Reactor (FHR) that leverages physics-inspired models for key reactor components and uses data-driven methods for rapid system state space prediction. The Xenon reactivity feedback model is integrated to inform the surrogate model about the reactor core and the homologous pump theory model is the basis for representing pump degradation. Using a detailed, two dimensional thermal hydraulics model to generate data on the FHR, we train a network of Vectorized Autoregressive Moving-Average with eXogenous input (VARMAX) models to predict the remaining state values. The result is a surrogate model that provides a detailed reactor state representation of 41 system states and a pump degradation analysis. The framework is applied to Load Follows profiles, yielding high accuracy and a speedup that is more than 4000x faster compared to the higher- fidelity thermal hydraulics model, enabling real-time operational intelligence and applications in long horizon predictions. While the surrogate model framework is demonstrated for the particular case of FHR, the hybrid physical/data-driven modeling approach including the network of surrogates and the underlying modularity has the potential to be applied to other physical asset systems.

Digital Twins↗

A transmissive concentrator photovoltaic module with cells directly cooled by silicone oil for solar cogeneration systems

Hybrid concentrator photovoltaic-thermal systems can cogenerate electricity and heat by beam-splitting incoming concentrated light onto photovoltaic cells and a thermal receiver to increase total conversion efficiency and potentially reduce system cost. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. Visible light is collected using infrared-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of 43.3% for light of wavelength λ < 873 nm, while 44.2% of out-of-band light with λ > 873 nm is transmitted through for collection by a thermal receiver. During testing on a dual-axis tracked parabolic concentrator dish at up to 166 suns, cell temperatures were maintained at 119 °C or below via a novel active cooling method. This cooling system strictly flows silicone oil directly across both sides of the cells, without inhibiting optical transmission, as verified through experimentation and simulation. The module was validated outdoors for 572 sun·hrs, and achieved a maximum thermal receiver temperature of 180 °C. 86.1% of incident solar power is collected at 166 suns average concentration collectively among the electrical, cooling, and thermal receiver subsystems. The remaining 13.9% is lost to mirror reflectivity, dish shadowing, receiver reflection, and thermal losses. The ability to directly cool the cells with an inert silicone oil offers the potential for reduced system cost relative to previous transmissive hybrid concentrator photovoltaic-thermal systems, including microfluidic-cooled designs. This solar cogeneration capability is valuable in a wide range of commercial and industrial applications.

14 SOLAR ENERGY↗

Exploring mounting solutions for cryogenically cooled thin crystal optics in high power density x-ray free electron lasers

This study investigates three mounting methods—clamping, soldering, and a hybrid clamping–soldering approach—for cryogenically cooled thin diamond crystals crucial to stable operation of X-ray Free Electron Laser (XFEL) systems. While clamping methods exhibit temperature resilience and flexibility, meticulous design is required to prevent stress-induced warping and reduce thermal contact area. Soldering methods offer reliable mechanical and thermal bonding but encounter challenges due to the coefficient of thermal expansion mismatch at cryogenic temperatures. The hybrid method, integrating clamping and soldering with strain relief cuts, effectively mitigates overall distortion caused by mounting and XFEL thermal loads. These findings offer a novel mounting solution for high-performance x-ray optics in XFEL research and applications, ensuring stability and optimal functionality in cryogenic conditions.

Instruments & Instrumentation↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗