Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hydrogen Tank”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Integrated Modeling and Optimal Operation of Multi-Energy System for Coastal Community

Focusing on remote, isolated, and underserved communities, a multi-energy system is designed in this research which is capable of utilizing different energy sources in a more coordinated and energy-efficient way to support various demands, such as fresh water, electricity, hydrogen, thermal demand, etc. The energy sources considered are renewables (wind, solar, marine) and natural gas. The energy conversion process includes water desalination, gas combustion, water electrolyzation, and different types of storage (hydrogen tank, electricity, thermal, etc.) are designed to serve as buffers in supply-demand balancing. Sets of experiments are designed to demonstrate the effectiveness of the proposed operating model and investigate the impact of uncertainties from renewable generations and demands.

Chen, Yang↗

Savannah River Site High Level Radioactive Waste Tank Sample Thermolytic Hydrogen Generation - 20346

To support the revision of flammability calculations and controls for the Savannah River Site (SRS) High-Level Radioactive Waste (HLW) tanks, Savannah River National Laboratory (SRNL) conducted laboratory measurements with the goal of quantifying hydrogen produced in HLW by non-radiolytic chemical reactions (i.e., thermolysis). Testing was performed with HLW tank supernate samples that represented a cross section of types of waste at SRS, including tanks that store typical evaporator concentrate, dissolved salt-cake, dilute recycle stream from the Defense Waste Processing Facility (DWPF), evaporator concentrate of the recycle stream from DWPF, fresh waste from the canyon separations facility, and waste that has been through salt processing cesium removal. Non-radioactive simulant testing included the classes of organic compounds historically introduced into the HLW tanks that were recently shown to be the most active toward the thermolytic generation of hydrogen. The reaction rate equations developed for thermolytic hydrogen generation from each class of organic compound showed direct proportionality to organic compound concentration and hydroxide concentration. Simulant testing identified that highly concentrated waste with high hydroxide concentration had the highest rates of thermolytic hydrogen generation. Using the radioactive tank sample thermolysis measurements at high temperatures and the mechanistic salt dependence of the simulant models, a global model was developed for tank waste thermolytic hydrogen generation as a function of total organic carbon content of SRS HLW. Through the primary functionality of the global model (organic carbon and free hydroxide concentration), the relative reactivity of the organic carbon in the waste was quantified. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conformable, Composite Tank for Liquid Hydrogen Storage in Heavy-duty Ground Transportation

Raytheon Technologies Research Center (RTRC), with its partners, Argonne National Labs and University of Dayton Research Institute proposed to design and manufacture a conformable composite tank prototype to store liquid Hydrogen (LH2) for heavy-duty truck applications. A dual-wall tank concept was proposed where an outer shell covers and protects an inner pressure vessel that stores liquid hydrogen. The inner pressure vessel is liner-less and designed with a conformable concept, derived from prior RTRC ARPA-E program where multiple vessels are coalesced into one, maximizing space utilization and reducing surface area for heat leak. The gap between the dual wall is evacuated of air pressure, and filled with multi-layer insulation to minimize radiative heat transfer. Fiber reinforced composites were proposed for light-weighting and conformable shape manufacture. To minimize LH2 leakage, carbon nanotubes-infused composites were proposed, in addition to use of thin plies. The project was divided into two 18-month budget periods (BP), BP1 and BP2, separated by a Go/No-Go gate review. The high-level goal for BP1 was to demonstrate the feasibility of the overall approach, the tank design, material selection, and manufacturing methodology, build and test a prototype tank; and the goal for BP2 was to design and manufacture a conformal tank per DOE requirements (minimum 20 kg of LH2) and perform a successful test of the tank. The program was terminated about two-thirds of the way through BP1. The outcome of this program would have permitted long-haul trucks and construction vehicles to use liquid Hydrogen, reducing the emission of green-house gases. This technology is applicable to other transportation sectors as well.

08 HYDROGEN↗

Assessment of tank designs for hydrogen storage on heavy duty vehicles using metal hydrides

The objective of this project was to evaluate material-based hydrogen storage solutions as a replacement for high-pressure hydrogen gas or liquid hydrogen on Class 7 or 8 tractor fuel cell electric vehicles. The project focused on low-density main-group hydrides, a well-known class of materials for hydrogen storage. Prior research has considered metal amides as storage materials for light-duty vehicles but not for heavy-duty applications. The project established the basis for further development of storage systems of this type for heavy duty vehicles (HDV). Systems analysis of an HDV storage system comprised of a tank and associated balance of plant (piping, coolant tubes, burner) was performed to determine the usable hydrogen capacity. A composite storage material comprised of a metal hydride mixed with a high thermal-conductivity carbon is predicted to have a usable hydrogen volumetric capacity comparable to or exceeding that of 700 bar pressurized hydrogen gas. The gravimetric capacity of this material is also predicted to be competitive with pressurized gas, particularly if costly carbon fiber composite Type III or Type IV tanks are excluded. The storage system design parameters and material properties served as inputs to a second model that simulates fuel cell operation in conjunction with the storage system during an HDV drive cycle. The results show that sufficient hydrogen pressure can be produced to operate a Class 8 HDV, yielding a range of ~480 miles. These results are particularly relevant for high-impact regions, such as the South Coast Air Quality Management District, for which an economical vehicular hydrogen storage system with minimal impact on cargo capacity could accelerate adoption of heavy-duty fuel cell electric vehicles. An additional benefit is that knowledge generated by this project can assist in development of material-based storage for stationary applications such as microgrids and backup power for data centers.

08 HYDROGEN↗

Optimizing the Heisenberg Vortex Tube for Hydrogen Cooling (Final Technical Report)

Hydrogen utilization at Plug Power sites ranges between 70-93% with the remainder vented and lost to the atmosphere. The goal of this project was to improve hydrogen utilization at Plug Power fulfillment centers via the patented Heisenberg vortex tube (HVT). The HVT combines conventional counterflow vortex tubes with para-orthohydrogen conversion catalyst to allow the cooling of hydrogen flows with no moving parts or external energy inputs. In year 1 of this project the HVT was evaluated to improve hydrogen utilization via the following concepts: 1) increasing liquid hydrogen pump volumetric efficiency by 20% through vapor separation and subcooling of the liquid, 2) reducing liquid hydrogen storage tank boil-off losses by 20% through thermal vapor shielding (TVS), and 3) increase isentropic efficiency of supercritical hydrogen expansion at 40-50 K, from 31% to over 40%. The TVS concept was selected as the most favorable application for further development. While the conceptual analysis was underway, the cryocatalysis hydrogen experiment facility (CHEF) was retrofitted with a new cryocooler, higher pressure condenser tanks, and in-situ fiber-optic Raman probes for ortho-parahydrogen composition analysis at the inlets and outlets of the HVT. To our knowledge this is the first in-situ implementation of cryogenic Raman probes for ortho-parahydrogen analysis. Subsequent testing of catalyzed and non-catalyzed HVT identified a low flow rate, high-conversion efficacy regime well suited for TVS development. Computational fluid dynamics (CFD), Reduced order modeling (ROM), and quantum Monte Carlo atomistic simulations were applied to optimize the design of the HVT implemented for TVS. The simulations and analysis identified a ruthenium-based catalyst as the most optimal for high conversion with little pressure losses and was matched to experimental measurements. These results indicated the design could achieve the 20% boil-off reduction target. An HVT field-trial was designed and constructed by Plug Power and implemented at a customer site. However, budget limitations reduced the amount of catalyst that could be applied to the HVT. With the reduced amount of catalyst, CFD analysis estimated about 3% reduction in boil-off. A similar amount of boil-off reduction was observed during preliminary measurements during tank commissioning. However, the results have a large margin for error and were operated at relatively low tank temperatures when the HVT has the lowest potential for improvement. This project demonstrated the use of para-orthohydrogen catalysis for reducing liquid hydrogen tank boil-off losses. The field trial system is anticipated to provide long-term experimental measurements on tank operational performance that will allow Plug Power to instrument additional tanks in the future. Recommendations for future work include the development of higher activity, lower cost para-orthohydrogen conversion catalyst for use in the HVT. Tank process optimizations could maximize the efficacy of the HVT and further improve hydrogen utilization.

08 HYDROGEN↗

Study of Hydrogen Fuel Cell Technology for Freight Rail Propulsion and Review of Relevant Industry Standards.

Alternatives to conventional diesel electric propulsion are currently of interest to rail operators. In the U.S., smaller railroads have implemented natural gas and other railroads are exploring hydrogen technology as a cleaner alternative to diesel. Diesel, battery, hydrogen fuel cell, or track electrification all have trade-offs for operations, economics, safety, and public acceptability. A framework to compare different technologies for specific applications is useful to optimize the desired results. Standards from the Association of American Railroads (AAR) and other industry best practices were reviewed for applicability with hydrogen fuel cell technology. Some technical gaps relate to the physical properties of hydrogen, such as embrittlement of metals, invisible flames, and low liquid temperatures. A reassessment of material selection, leak/flame detection, and thermal insulation methods is required. Hydrogen is less dense and diffuses more easily than natural gas, and liquid hydrogen is colder than liquefied natural gas. Different densities between natural gas and hydrogen require modifications to tank designs and flow rates. Leaked hydrogen will rise rather than pool on the ground like diesel, requiring a modification to the location of hydrogen tanks on rolling stock. Finally, the vibration and shock experienced in the rail environment is higher than light-duty vehicles and stationary applications for which current fuel cell technology has been developed, requiring a modification in tank design requirements and testing.

08 HYDROGEN↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 44 Dissolved Saltcake Samples

Saltcake core samples collected from Tank 44 in 2006 were dissolved to provide material for HGR measurements applicable to F-Area dissolved saltcake material. Additionally, characterization was performed on the Tank 44 saltcake material. The following are key results from the Tank 44 saltcake characterization. The Tank 44 Upper Saltcake Composite, corresponding to the 171 to 285 inch tank level, contained by mass approximately 69% sodium nitrate, 11% sodium carbonate, 8% sodium nitrite, smaller amounts of other salts and components, and 9% unquantified (which includes water, water of hydration, oxygen/hydrogen content of oxides and hydroxides, and uncertainty). The Tank 44 Lower Saltcake Composite, corresponding to the 76 to 114 inch tank level, contained by mass approximately 49% sodium carbonate, 18% sodium nitrate, smaller amounts of other salts, at least 8% sludge, and 9% unquantified (see above). The dissolved saltcake contained free hydroxide less than quantifiable (<0.01 M) due to the limited quantity of material that could be removed from the Shielded Cells based on the sample radioactivity. Measurement by pH paper provided an approximate pH of 12. The following are key results from the Tank 44 HGR testing. During boiling at 106.7 °C, HGR for Tank 44 dissolved saltcake without added glycolate was 7.2×10 -8 ft 3 h -1 ga l-1 . During boiling at 106.9 °C, HGR for Tank 44 dissolved saltcake with 1000 mg/L of added glycolate was 8.2×10 -8 ft 3 h -1 gal -1 . ∙ For the test without added glycolate, the first several HGR measurements at 70, 85, and 100 °C gave indication of the release of dissolved hydrogen and should not be used to represent the sustained thermolytic HGR for those temperatures. The measurements at boiling are the best representation of thermolysis in this testing. Carbon dioxide was observed at concentrations up to 6 vol% in the flow-system offgas for the test at boiling. ∙ Methane generation was observed at 100 °C and boiling. Methane concentration in the total gas generated during testing remained well below the lower flammability limit for methane in air. The addition of 1000 mg/L of glycolate did not have a significant impact on the hydrogen generation rates measured during this testing. The low hydroxide concentration in the Tank 44 dissolved saltcake likely influenced the relatively low thermolytic HGR and high carbon dioxide release observations in this testing. Based on the observation that methane was generated or released upon heating SRS radioactive Tank 44 waste samples to 100 °C and above, we recommend gaining a greater understanding of the cause and mechanism of its generation. First, the applicable literature should be reviewed to reveal the thermolytic methane generation mechanisms of possible methane generating species in the SRS CSTF. If warranted, a plan should be developed for simulant tests with methylated siloxanes and other applicable compounds in order to gain a better mechanistic understanding of methane generation in the SRS CSTF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 44 Dissolved Saltcake Samples

Saltcake core samples collected from Tank 44 in 2006 were dissolved to provide material for HGR measurements applicable to F-Area dissolved saltcake material. Additionally, characterization was performed on the Tank 44 saltcake material. The following are key results from the Tank 44 saltcake characterization. The Tank 44 Upper Saltcake Composite, corresponding to the 171 to 285 inch tank level, contained by mass approximately 69% sodium nitrate, 11% sodium carbonate, 8% sodium nitrite, smaller amounts of other salts and components, and 9% unquantified (which includes water, water of hydration, oxygen/hydrogen content of oxides and hydroxides, and uncertainty). The Tank 44 Lower Saltcake Composite, corresponding to the 76 to 114 inch tank level, contained by mass approximately 49% sodium carbonate, 18% sodium nitrate, smaller amounts of other salts, at least 8% sludge, and 9% unquantified (see above). The dissolved saltcake contained free hydroxide less than quantifiable (<0.01 M) due to the limited quantity of material that could be removed from the Shielded Cells based on the sample radioactivity. Measurement by pH paper provided an approximate pH of 12. The following are key results from the Tank 44 HGR testing. During boiling at 106.7 °C, HGR for Tank 44 dissolved saltcake without added glycolate was 7.2×10 -8 ft 3 h -1 gal -1 . During boiling at 106.9 °C, HGR for Tank 44 dissolved saltcake with 1000 mg/L of added glycolate was 8.2×10 -8 ft 3 h -1 gal -1 . For the test without added glycolate, the first several HGR measurements at 70, 85, and 100 °C gave indication of the release of dissolved hydrogen and should not be used to represent the sustained thermolytic HGR for those temperatures. The measurements at boiling are the best representation of thermolysis in this testing. Carbon dioxide was observed at concentrations up to 6 vol% in the flow-system offgas for the test at boiling. Methane generation was observed at 100 °C and boiling. Methane concentration in the total gas generated during testing remained well below the lower flammability limit for methane in air. The addition of 1000 mg/L of glycolate did not have a significant impact on the hydrogen generation rates measured during this testing. The low hydroxide concentration in the Tank 44 dissolved saltcake likely influenced the relatively low thermolytic HGR and high carbon dioxide release observations in this testing. Based on the observation that methane was generated or released upon heating SRS radioactive Tank 44 waste samples to 100 °C and above, we recommend gaining a greater understanding of the cause and mechanism of its generation. First, the applicable literature should be reviewed to reveal the thermolytic methane generation mechanisms of possible methane generating species in the SRS CSTF. If warranted, a plan should be developed for simulant tests with methylated siloxanes and other applicable compounds in order to gain a better mechanistic understanding of methane generation in the SRS CSTF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Electrochemical Hydrogen Compressor

U.S. automakers have invested significant resources in the research and development of hydrogen fuel cell electric vehicles (FCEVs). However, to enable the widespread deployment of FCEVs, an additional major investment is required to achieve an infrastructure for compressing hydrogen in hydrogen fueling stations. In order to dispense hydrogen to FCEV tanks quickly, the hydrogen must be compressed above a pressure of 875 bar (12,687 psi) at the fueling station. Mechanical compressors currently in use have high maintenance costs, poor reliability, and are noisy. To eliminate the need for mechanical compressors, Plug Power is extending its extensive experience in high-pressure proton-exchange-membrane (PEM), to develop an electrochemical hydrogen compressor (EHC) system for refueling applications that can deliver hydrogen at pressures greater than 875 bar. The work performed during this project was a collaboration between the Nation Renewable Energy Laboratory (NREL), Rensselaer Polytechnic Institute (RPI), and Gaia Energy Research Institute LLC (GAIA).

08 HYDROGEN↗

Thermodynamic modeling of hydrogen fueling process from high-pressure storage tank to vehicle tank

This study develops a hydrogen fueling station (HFS) thermodynamic model that simulates the actual fueling process in which hydrogen is supplied from a high-pressure (HP) storage tank into a fuel cell electric vehicle (FCEV) tank. To make the model as accurate as possible, we use the same components and specifications as in actual HFSs, such as a pressure control valve, a pre-cooling system, and an FCEV tank. After the components and their specifications are set, pressure and temperature profiles are set as the HP tank supply conditions. Based on the pressure and temperature profiles, the model solves for the temperature, pressure, and mass flow rate of hydrogen at each downstream position, including the inside of the vehicle tank. The values predicted by the model are compared with experimental data, and we show that the developed model makes it possible to accurately simulate those values at any position during the fueling process.

08 HYDROGEN↗

Thermodynamic parametric analysis of refueling heavy-duty hydrogen fuel-cell electric vehicles

Reliable design and safe operation of heavy-duty hydrogen refueling stations are essential for the successful deployment of heavy-duty fuel cell electric vehicles (FCEVs). Fueling heavy-duty FCEVs is different from light-duty vehicles in terms of the dispensed hydrogen quantities and fueling rates, requiring tailored fueling station design for each vehicle class. In particular, the selection and design of the onboard hydrogen storage tank system and the fueling performance requirements influence the safe design of hydrogen fueling stations. A thermodynamic modeling and analysis are performed to evaluate the impact of various fueling parameters and boundary conditions on the fueling performance of heavy-duty FCEVs. Here, we studied the effect of dispenser pressure ramp rate and precooling temperature, initial tank temperature and pressure, ambient temperature, and onboard storage design parameters, such as onboard storage pipe diameter and length, on the fueling rate and final vehicle state-of-charge, while observing prescribed tank pressure and temperature safety limits. An important finding was the sensitivity of the temporal fueling rate profile and the final tank state of charge to the design factors impacting pressure drop between the dispenser and vehicle tank, including onboard storage pipe diameter selection, and flow coefficients of nozzle, valves, and fittings. The fueling rate profile impacts the design and cost of the hydrogen precooling unit upstream of the dispenser.

08 HYDROGEN↗

Structure property correlations in wet-spun textile PAN fibers for cost-effective carbon fibers applicable in H 2 storage tank manufacturing

The economic viability of high-strength carbon fibers is pivotal for their integration into Type IV compressed hydrogen storage tanks. Oak Ridge National Laboratory is advancing this objective by developing cost-effective, textile-grade polyacrylonitrile (PAN) precursor fibers through an optimized wet spinning-process to garner more microstructural control over the precursor fibers. Here, this study examines the microstructural characteristics of PAN fibers, particularly the crystalline orientation factor, and their impact on mechanical properties in both precursor and thermally converted carbon fibers (CFs). Three wet-spun PAN fibers, all having diameters of 12-13 µm but varying orientation factors were assessed. Comprehensive characterization using X-ray scattering and microscopy revealed that fibers with higher orientation factors exhibited enhanced crystallinity and optimized crystallite sizes. Mechanical testing demonstrated that the PAN fiber with the highest orientation factor achieved the greatest tensile strength (98 ksi) and modulus (1.60 Msi). Additionally optical and scanning electron microscopy confirmed smooth and defect-free surfaces across all samples. These findings indicate that manipulating spinning parameters to maximize orientation factor is more impactful in achieving high strength and modulus over factors attributed to crystallinity and crystallite sizes. Here, highest performing CFs, thermally processed in lab from textile-grade precursor averaged 558 ksi, a 10% increase over previous results.

36 MATERIALS SCIENCE↗

Evaluation of Thermolytic Production of Hydrogen from Glycolate and Common Tank Farm Organics in Simulated Waste

The Savannah River National Laboratory (SRNL) has performed testing to investigate the thermolytic production of hydrogen gas from organic species present in the Savannah River Site (SRS) Concentration, Storage, and Transfer Facilities (CSTF). SRNL designed an experimental apparatus to measure the timedependent concentration of hydrogen in the headspace over a reacting mixture of simulated caustic waste media and organic compounds as well as a methodology to calculate a steady-state hydrogen generation rate (HGR) from this data. Special focus was given to glycolate, which is not currently present in CSTF waste but will be contained in the recycle stream from the Defense Waste Processing Facility (DWPF) under the upcoming alternate reductant flowsheet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effective thermal conductivity of insulation materials for cryogenic LH 2 storage tanks: A review

An accurate estimation of the effective thermal conductivity of various insulation materials is essential in the evaluation of heat leak and boil-off rate from liquid hydrogen storage tanks. In this work, we review the existing experimental data and various proposed correlations for predicting the effective conductivity of insulation systems consisting of powders, foams, fibrous materials, and multilayer systems. We also propose a first principles-based correlation that may be used to estimate the dependence of the effective conductivity as a function of temperature, interstitial gas composition, pressure, and structural properties of the material. We validate the proposed correlation using available experimental data for some common insulation materials. Further improvements and testing of the proposed correlation using laboratory scale data obtained using potential LH 2 tank insulation materials are also discussed.

08 HYDROGEN↗

Hydrogen/bromine flow battery in which hydrogen is freely exchanged between two cell compartments

A flow battery system includes a first tank including a hydrogen reactant, a second tank including a bromine electrolyte, and at least one cell including a first electrolyte side operably connected to the first tank and a second electrolyte side operably connected to the second tank. The battery system further includes a direct connection line directly connecting the first tank and the second tank and configured such that the hydrogen reactant passes between the first tank and the second tank.

Albertus, Paul↗

Impacts of the Addition of Sodium Reactor Experiment (SRE) and DR-3 Fuel from H-Canyon to Tank 40 on Acid Stoichiometry and Hydrogen Production

H-Canyon plans to discard Sodium Reactor Experiment (SRE) material that is currently stored in Tanks 16.3 and 16.4. Savannah River Remediation (SRR) determined that a portion of the SRE material can be added to Sludge Batch 9 (SB9) in Tank 40 and the remainder will be added to Sludge Batch 10 (SB10) that is currently being prepared in Tank 51. A processing flowsheet for both the nitric-formic acid flowsheet and the nitric-glycolic acid flowsheet were previously developed for SB9 sludge-only and coupled operation with the Actinide Removal Process – Modular Caustic Side Solvent Extraction Unit (ARP-MCU) and the Salt Waste Processing Facility (SWPF). Due to the compositional change in Tank 40 after the addition of SRE material, it is necessary to determine the influence on the acid stoichiometry operating window and hydrogen production for SB9 processing. An assessment was completed to address the influence of an addition of SRE and DR-3 Fuel from H-Canyon on the chemistry of Tank 40, the defined acid stoichiometry window (with and without SWPF streams) for the nitric-formic and nitric-glycolic acid flowsheets, and the resulting influence of the hydrogen production. Hydrogen production during the SRAT/SME cycles consists of thermolytic, radiolytic, and catalytic hydrogen. For the nitric-formic acid flowsheet, catalytic hydrogen dominates the hydrogen production during DWPF operation mode for the SRAT and SME vessels. This report was written to summarize that assessment. No SRNL testing is needed prior to adding up to 7,100 additional gallons of SRE and DR-3 Fuel from H-Canyon to Tank 40. Also, the addition of SRE will not exceed the Shielded Cells reported values for catalytic hydrogen for either the nitric-formic acid flowsheet (Technical Safety Requirement (TSR) limit of 0.15 lb/h) or the nitric-glycolic acid flowsheet (TSR limit 0.024 lb/h). The addition of the ARP stream from SWPF and the use of the nitric-glycolic acid flowsheet are both expected to decrease hydrogen generation, leading to a larger safety margin in the CPC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogen Mitigation Process Installation at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) have developed and are implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure—from 1.33 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. We demonstrated the performance of a laboratory-scale version of this module. Testing showed that the module performed as expected: the accuracy of the sensing function was ±7%, and the hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP planned, specified, and designed a mitigation process that is based on the integrated module. We are currently completing installation of this process at ASP's Nevada Solar One power plant in Boulder City, Nevada, USA. The mitigation process is being installed at ground level below the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. In this paper, we report progress on the installation and describe some of the many design details and challenges that we addressed during the past year. We will generate initial performance data from the Nevada Solar One mitigation process in early 2020.

41 EE - Solar Energy Technologies Office (EE-4S)↗