Search NASA⌕ Search

SEARCH · Search NASA

Results for “Illinois State Geological Survey”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CO2 Capture from Biofuels Production and Storage into the Mt Simon Sandstone

Advanced carbon capture and storage (CCS) technologies offer significant potential for reducing anthropogenic carbon dioxide (CO2) emissions, while minimizing the cost of employing these technologies. Under the Industrial Carbon Capture and Storage (ICCS) Program, the U.S. Department of Energy (DOE) collaborated with industry in cost-sharing arrangements to demonstrate technologies that captured CO2 emissions from industrial sources and either stored or beneficially re-use them. The technologies included in the ICCS program progressed beyond the research and development stage to a scale that can be deployed into commercial practice within the industry. The Illinois Industrial Carbon Capture and Storage (IL-ICCS) project sought to demonstrate the ability of the Mt. Simon Sandstone to accept and retain industrial-scale volumes of carbon dioxide (CO2) from an anthropogenic source for permanent geologic sequestration. The project was a collaboration of Archer Daniels Midland (ADM) Company, the Illinois State Geological Survey (ISGS), Schlumberger Carbon Services (SCS), and Richland Community College (RCC), and had average annual injection rate of between 1,500 and 2,400 metric tons per day (MTPD) or 0.5 to 0.7 million metric tons (MMT) annually. The project site is in Decatur, Illinois on the property of ADM and RCC (Fig 1) and is directly adjacent to the Illinois Basin – Decatur Project (IBDP), a large scale pilot project of the Midwest Geological Sequestration Consortium (MGSC), which collected and injected CO2 from the ADM fuel ethanol production unit, where high purity biogenic CO2 is produced during the anaerobic fermentation of sugars to alcohol. The IL-ICCS project had an operational period of approximately six (6) years, in which 3.5 MMT of CO2 was captured, compressed, injected, and permanently stored in the Mt Simon Sandstone.

01 COAL, LIGNITE, AND PEAT↗

Geology of the One Earth Energy Site

The One Earth Energy site is one of two sites in the Illinois Storage Corridor (ISC) project. The objectives of the ISC project is to accelerate commercial deployment of carbon capture utilization and storage at two individual sites and receive approvals for Underground Injection Control (UIC) Class VI permits for construction at each site. At the One Earth Energy site, an extensive data collection program was undertaken, which included the drilling of a test well (One Earth Energy #1 [OEE #1]), four 2D seismic lines, and a small 3D seismic survey. The OEE #1 well was drilled in 2022 and acquired extensive core, log, and testing data to characterize the subsurface geology of the site. Coring was focused on the storage interval, the Mt. Simon Sandstone, and the confining interval, the Eau Claire Formation. The core and log data were used to evaluate the sedimentology and sequence stratigraphy, as well as to develop the conceptual geologic model. This report includes the geological summaries of the Mt. Simon Sandstone and the Eau Claire Formation. The extensive analysis of the log data is included in the petrophysical section, showing ranges of porosity, estimated pore size, and the mineral content of selected zones in the well. The separate petrographic technical report entitled “Petrographic and Advanced Geologic Characterization Report on One Earth Energy #1 (API# 1211325373)”, report number DOE-UIUC-0031892-04, details thin section point-counting analysis that includes mineralogical and pore space analysis, including grain size analysis, annotated thin section photomicrographs, scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS), and statistics of grain size analysis on Mt. Simon thin sections from OEE #1. The final OEE #1 well data to be included in this geology report is the routine core analysis of both whole core plugs and rotary sidewall core plugs. In addition to the OEE #1 well, four 2D seismic lines and a small 3D survey were acquired as part of the overall subsurface geological characterization. This geology report references the seismic interpretation report, entitled “One Earth Energy Site Seismic Interpretation Task 5.0”, report number DOE-UIUC-0031892-07. This report details the stratigraphic and structural interpretation of the 2D and 3D seismic data acquired at the One Earth Energy site. The 2D seismic data was acquired in 2019 and 2021, and the 3D survey was acquired in 2022. The objectives of the seismic programs were to contribute to the subsurface characterization of the Mt. Simon-Eau Claire Storage Complex by evaluating the continuity of potential storage reservoirs and containment intervals across the project area, and to determine if any geologic features are present that would increase containment risk to the proposed carbon storage project.

09 BIOMASS FUELS↗

Wabash CarbonSAFE (Subtask 3.1 - Application of the NRAP Tools to the Wabash CarbonSAFE Site for Risk Assessment Associated with Geologic Carbon Storage Activities)

This report documents a risk assessment of CO 2 containment loss and induced shear failure due to geologic carbon storage at the Wabash CarbonSAFE site. The operator, Wabash Valley Resources, has proposed adapting the onsite integrated gasification combined cycle (IGCC) facilities to produce hydrogen and injecting the byproduct CO 2 stream into the subsurface Potosi dolomite formation. The purpose of this study is to assess (1) CO 2 sequestration performance relative to the CarbonSAFE goals of storing 50 Mt over 30 years, (2) the risk of containment loss due to leakage along a wellbore and into an overlying aquifer, and (3) the state of stress and risk of reactivating existing fractures. This study relied upon the initial site characterization work performed by the Illinois State Geologic Survey (ISGS) along with analogue data collected from other carbon sequestration projects in the region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a Regional Roadmap for Source Network and Storage Deployment for CarbonSAFE Illinois - Macon County (Task 10)

Research documented in this report includes (1) resource estimates for the Lower Mt. Simon Sandstone in the Illinois Basin, including storage and cost estimates, and (2) regional roadmaps for carbon capture and storage (CCS) deployment using five capture facilities throughout the Illinois Basin: Archer Daniels Midland Decatur (ADM Decatur), Abbott Power Plant, City Water, Light, and Power (CWLP), One Earth Energy, and Prairie State Energy Campus (PSEC). Resource estimates were developed using the Sequestration of CO 2 Tool (SCO2T) and data provided by the Illinois State Geological Survey (ISGS), and regional roadmaps for CCS deployment were developed in SimCCS Gateway, a decision-support tool for designing CCS infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MRCI Task 3: Facilitating Data Collection, Sharing, and Analysis Final Technical Summary Report

The Midwest Regional Carbon Initiative (MRCI) Task 3.0 was defined to facilitate development of carbon capture, utilization, and storage (CCUS) in the region by collection and sharing of existing and new technical data from CCUS projects and research. The task also included support for further analysis and assessment of tools by the project team and by researchers working on programs such as National Risk Assessment Partnership (NRAP), machine learning (ML) techniques, and assessment and improvement of CCUS site assessment, operations, and monitoring aspects. Work under Task 3.0 addressed key issues related to CCUS deployment and provided foundational research and datasets to help establish CCUS projects in the MRCI. Report Authors and Principal Technical Contributors: Joel Sminchak, Laura Keister, Mackenzie Scharenberg, Priya Ravi-Ganesh, Autumn Haagsma, Srikanta Mishra, Jared Hawkins, Jared Schuetter, Amy Lang, Jaelen Lewis, Derrick James, Jorge Barrios, Stuart Skopec, and Sanjay Mawalkar (Battelle). Chris Korose, Carl Carmen, Nate Grigsby, Nathan Webb (Illinois State Geological Survey). Principal Investigators: Dr Neeraj Gupta, Dr. Chris Korose.

MRCI,NRAP,data collection,data compilation,legacy ↗

Illinois Storage Corridor, CarbonSAFE Phase III: UIC Class VI Permitting Plan

The Illinois Storage Corridor (ISC) project evaluated two distinct sites to determine the feasibility of commercial-scale CO₂ storage at each. The project leveraged the region's exceptional geological characteristics, particularly the well-characterized Cambro-Ordovician Storage Complex, to enable permanent geological storage of more than 50 million tonnes of CO₂ over 30 years. The two storage sites are located at One Earth Energy (OEE) facility in northcentral Illinois and Prairie State Generating Company (PSGC) in southcentral Illinois. Once operational, these facilities will combine to capture and store more than 6.5 million tonnes of CO₂ per year, positioning the ISC among the largest carbon storage regions globally. Preliminary homogeneous dynamic modeling based on regional and site-specific reservoir characteristics indicates promising injection capabilities at both locations. For the OEE site, modeling predicts a maximum allowable injection rate of 3.7 MTPA, with a baseline scenario of 1.7 MTPA over 30 years producing a CO₂ plume radius of 1.4 miles at end of injection. For the PSGC site, incorporating recent well data, modeling indicates a single-well maximum injection rate of 2.1 MTPA, with a plume radius of 4.2 miles at end of injection for the 60 MT over 30 years scenario. The primary objective of this CarbonSAFE Phase III project is to develop and submit Class VI Underground Injection Control (UIC) permit applications to the U.S. Environmental Protection Agency Region 5. The permitting plan outlines comprehensive site characterization, Area of Review delineation, monitoring programs, well construction designs, financial responsibility provisions, and post-injection site care procedures necessary to demonstrate safe, permanent CO₂ storage protective of underground sources of drinking water. Three UIC Class VI permit applications for the OEE site were submitted to EPA in October 2022 and are progressing through technical review, with final permit decision projected by June 2026. Through five rounds of Requests for Additional Information and responses, the applications have been refined to address computational modeling, area of review delineation, well integrity, monitoring protocols, and financial assurance requirements. For the PSGC site, finalized characterization and permitting documentation was delivered directly to the facility in July 2023 due to business constraints precluding formal federal regulatory submission. This comprehensive permitting effort builds upon extensive prior subsurface evaluations and demonstration projects that have confirmed the feasibility of widespread commercial-scale carbon storage in the region.

01 COAL, LIGNITE, AND PEAT↗

Illinois Storage Corridor - CarbonSAFE Phase III: Policy, Regulatory, Legal and Permitting Characteristics; Subtask 5.5

The Illinois Storage Corridor (ISC) project aims to advance the commercial development and implementation of carbon capture and storage (CCS) technologies within a region in Illinois of suitable geology for carbon dioxide (CO 2 ) storage in deep saline aquifers. The project partners have annual emissions greater than 6.5 million tonnes per year; storage hubs are being explored at two sites—one near the One Earth Energy facility in east-central Illinois, and one near the Prairie State Generating Company campus in southwest Illinois. To implement the technology, legal, policy, and economic considerations must be explored. The United States Environmental Protection Agency (US EPA) administers the Underground Injection Control (UIC) program and is responsible for issuing Class VI permits to construct and operate CO 2 injection wells, i.e., a UIC Class VI well permit is required to inject CO 2 into the subsurface for geologic sequestration. The largest consideration of the Class VI well requirements is to protect underground sources of drinking water (USDWs). Additionally discussed are considerations for Class VI permits relating to public engagement. Besides permitting, property rights to storage sites, subsurface pore spaces, and areas for pipeline transportation must be secured. Pore space rights is still a novel concept being explored and not yet addressed by the Illinois legislature. It is believed that surface property rights are required for the subsurface pore space below, so long as there is not a separated mineral estate in the subsurface. Illinois legislature has addressed securing rights-of-way for CO 2 transportation, allowing for easements and the exercise of eminent domain to secure such rights. Economically, the incentives for CCS are ever-expanding. Recently, the federal government broadened the availability and increased the dollar-amounts for the § 45Q tax credits for geological storage of carbon oxides. Congress has also authorized the Advanced Industrial Facilities Development Program which allocates billions of dollars in funds to installing technology at industrial facilities to reduce greenhouse gas emissions. On the state level, Illinois has had its own incentives for CCS projects since 2009 and expanded its emission-related goals again in 2021. The law enacted in 2021 specifically creates a commission to explore implementing CCS at Prairie State Generating Company, a partner on the Illinois Storage Corridor project.

54 ENVIRONMENTAL SCIENCES↗

One Earth Energy Static and Dynamic Reservoir Modeling

This report presents the static and dynamic reservoir modeling conducted for the CarbonSAFE Phase III Illinois Storage Corridor project to assess the feasibility of commercial-scale CO 2 storage in the Mt. Simon Sandstone at the One Earth Energy (OEE) site in McLean County, Illinois. Three-dimensional geocellular models of the Mt. Simon storage complex were developed in Petrel ® by integrating petrophysical log data, core analyses, and seismic surveys from the OEE #1 stratigraphic test well and two nearby wells, with multiple model versions created as new data became available. Dynamic reservoir simulations, performed using Landmark's Nexus software, progressed through three phases (preliminary, sensitivity, and UIC Class VI permit studies) evaluating injection scenarios across varying rates, well orientations, permeability models, and multi-well configurations. Results demonstrate that commercial-scale storage is feasible: three injection wells spaced approximately one mile apart can store a total of 90 million tonnes of CO 2 over 20 years, producing a combined plume with an equivalent radius of 3.2 miles and a maximum pressure-front-defined Area of Review of 178 mi 2 at the end of injection that diminishes to 34 mi 2 after 50 years of post-injection monitoring. Sensitivity analyses indicate that a 20% change in porosity or permeability yields approximately a 7% change in AoR radius, and that perforating the high-permeability arkosic zone minimizes the pressure front compared to injection in the upper Mt. Simon Sandstone.

09 BIOMASS FUELS↗

Mitchell CarbonSAFE

Project update presentation for the 2025 U.S. Department of Energy Fossil Energy and Carbon Management and National Energy Technology Lab Carbon Management Research Project Annual Review Meeting

Williams-Stroud, Sherilyn [Univ. of Illinois at Ur↗

Unsupervised Clustering of Microseismic Events and Focal Mechanism Analysis at the CO 2 Injection Site in Decatur, Illinois

Characterization of induced microseismicity at a carbon dioxide (CO 2 ) storage site is critical for preserving reservoir integrity and mitigating seismic hazards. We apply a multilevel machine learning (ML) approach that combines the nonnegative matrix factorization and hidden Markov model to extract spectral representations of microseismic events and cluster them to identify seismic patterns at the Illinois Basin-Decatur Project. Unlike traditional waveform correlation methods, this approach leverages spectral characteristics of first arrivals to improve event classification and detect previously undetected planes of weakness. By integrating ML-based clustering with focal mechanism analysis, we resolve small-scale fault structures that are below the detection limits of conventional seismic imaging. Our findings reveal temporal bursts of microseismicity associated with brittle failure, providing insights into the spatio-temporal evolution of fault reactivation during CO 2 injection. This approach enhances seismic monitoring capabilities at CO 2 injection sites by improving fault characterization beyond the resolution of standard geophysical surveys.

Willis, Rachel Marie [Sandia National Laboratories↗

A Play-Based Exploration of CO 2 Storage in the Illinois Basin: Community Baseline Assessment for Carbon Storage Engagement Planning in the Illinois Basin

This report presents a stakeholder mapping analysis conducted as part of the Play-Based Exploration of CO 2 Storage in the Illinois Basin project (DOE Cooperative Agreement DE-FE0032366). The analysis was undertaken to systematically identify, categorize, and characterize stakeholder groups and community conditions relevant to the planning and deployment of carbon capture and storage (CCS) infrastructure across the Illinois Basin. Its purpose is to establish a contextual baseline that informs targeted engagement strategies, supports equitable project planning, and strengthens the social dimensions of CCS site screening.

01 COAL, LIGNITE, AND PEAT↗

Storage Field Development Plan: One Earth Energy

This Storage Field Development plan presents the Storage Complex characterization results, construction, monitoring, and operational plans, and costs associated with the proposed One Earth Sequestration Carbon Capture and Storage (OES-CCS) site in McLean County, Illinois, near Gibson City. The proposed storage complex, known as the Mt. Simon Storage Complex, comprises the Cambrian Mt. Simon Sandstone reservoir and the primary seal, the Cambrian Eau Claire Formation. The lowermost Underground Source of Drinking Water (USDW) identified for the site is the Ordovician St. Peter Sandstone. Geologic characterization of the Mt. Simon Storage Complex at the OES-CCS site was performed by the Illinois Storage Corridor CarbonSAFE Phase III project, which also prepared and submitted three UIC Class VI applications to construct three injection wells; the permit applications were submitted and are in the federal EPA review process. A characterization well, OEE #1, was drilled to collect site-specific data. These data were analyzed and used to develop the UIC Class VI applications. The OEE #1 well will be converted to an in-zone monitoring (IZM) well for the injection phase. The proposed buildout for the OES-CCS site includes (1) three injection wells (OES #1, OES #2, and OES #3), (2) two IZM wells, (3) two above confining zone (ACZ) monitoring wells, one of which will be used to monitor the lowermost USDW, (4) capture and compression facilities, and (5) transportation facilities, i.e., pipelines. A pre-operational testing program was proposed in the Class VI permit application and will be employed at the site pending approval. Additional pre-injection (baseline), syn-injection, and post-injection monitoring and site care procedures will be followed by OES to ensure that injection activities are protective of human health and the environment. Injection is scheduled to begin in 2025, distributed across the three injection wells in accordance with the permit operating conditions. One Earth Sequestration intends to inject up to 90 million tonnes of CO 2 over a period of approximately 20 years. Injection will begin at approximately 0.5 million tonnes of CO 2 annually and ramp up to a maximum of 4.5 million tonnes annually. Daily injection rates are expected to range from 1,400 to 1,500 tonnes per day initially and reach a maximum of approximately 4,225 tonnes per day, depending on site geology and injectivity at each injection well location, and CO 2 availability. The costs associated with the OES-CCS project include pre-operational costs (e. g. additional seismic data acquisition and well drilling), capture and transportation facility and equipment costs, predicted field operating expenditures (OpEx), and decommissioning and post-injection site care (PISC) costs. The risks associated with project activities, such as site construction, injection operations, and verification of secure storage were evaluated, and mitigation strategies proposed to alleviate those risks.

09 BIOMASS FUELS↗

Stratigraphy‐Induced Localization of Microseismicity During CO 2 Injection in Illinois Basin

Abstract Subsurface fluid injection stimulates complex hydromechanical interaction, necessitating the integration of geomechanical data across spatial and temporal scales to consider the sophisticated behavior. Induced seismic response is usually associated with the complex reservoir architecture and pre‐existing features that are three‐dimensional, such as local stratigraphy, fractures, faults, and other discontinuities. This study encompasses laboratory characterization of the coupled hydromechanical response of cores extracted from rock formations in Illinois Basin: reservoir ‐ Mt. Simon sandstone, basal seal ‐ Argenta sandstone, and crystalline basement ‐ Precambrian rhyolite. High‐resolution numerical modeling allows considering the three‐dimensional complexity of the Illinois Basin Decatur Project with spatial resolution comparable to one of the active seismic surveys. A detailed reconstruction of the evolving state of stress in formations lacking direct stress measurements is achieved by numerical modeling that integrated laboratory‐derived hydromechanical properties, a porosity‐permeability relationship, active seismic data, and an inverted three‐dimensional porosity distribution. It appears that the microseismic clusters, mainly observed in the crystalline basement during the injection, are linked to zones experiencing more critically stressed conditions prior to injection. These zones have a potential for reactivation during the injection and are attributed to the specific local stratigraphy of the injection site, as well as transfer of triggering perturbations during the injection.

Bondarenko, N. [University of Illinois Urbana‐Cham↗

Facies Analysis of the Prairie Du Chien Group in the Illinois Basin and Analogous Rocks in Missouri and Kentucky

Funded in 2023 by the U.S. Department of Energy’s Phase II Carbon Storage Assurance Facility Enterprise (CarbonSAFE) initiative, a Heidelberg Materials cement plant in Mitchell, Indiana, is currently being evaluated as a potential Carbon Capture and Storage (CCS) subsurface injection site. The Heidelberg CCS project targets the middle to upper Prairie du Chien Group (Early Ordovician) in southwestern Indiana. Assessment of reservoir feasibility requires collection of field data, seismic surveys, well-log correlation, geologic modeling, characterization well drilling, well testing, and reservoir simulation. However, the proposed Heidelberg CCS site is in a data-limited region, lacking both outcrop analogs and deep wells penetrating the target interval, which makes geologic modelling difficult prior to drilling a characterization well. To directly address this problem, the present study was undertaken to understand the sedimentologic composition and stratigraphic architecture of the Prairie du Chien Group from analogous outcrops and cores in the Illinois Basin and adjacent regions.

Ali, Shah Bilawal [Univ. of Illinois at Urbana-Cha↗

Qualitative Risk Assessment of Legacy Wells within the Estimated Prairie State Generating Company Area of Review

This report details the digitization of a legacy wellbore database, including data processing assumptions, parameter estimation, and risk assessment methodology. The database, comprising 6,454 documents, was provided by ISGS. It includes valuable data from the Prairie State Generating Company (PSGC) and One Earth Energy (OEE) sites of the CarbonSAFE Phase III – Illinois Storage Corridor project. The report focuses on wells within a 15-mile radius from the Lively Grove #1 (LG#1) well at PSGC site, evaluating subsurface conditions and potential risks. A total of 4,386 wellbores within 15 miles of the LG#1 well were filtered based on depth and formation codes. LG#1 is the stratigraphic well at the PSGC site drilled in 2021. Ninety-four (94) wells penetrating the Maquoketa Shale Group (the primary confining unit) within the estimated area-of-review (AoR) for the PSGC site were evaluated using a qualitative risk assessment (QRA) methodology. The QRA developed by Arbad et al. 2022 focuses on legacy wells within the AoR and categorizes them based on well construction details. The QRA identifies wells that need immediate attention by categorizing them based on penetration depth and protection. Wells within the AoR were categorized into nine groups based on penetrations and protections. These categories range from Type 1 wells, with no documentation, to Type 9 wells, which do not penetrate the primary confining unit or storage reservoir (unit). Well accessibility within the AoR varies based on well status, including Dry & Abandoned (DA), Plugged & Abandoned (PA), Injection (INJ), Oil/Gas Producing (PROD), and Observation (Obs) wells. Accessibility levels were determined by well construction, with DA wells being the least accessible and Observation wells the most accessible, impacting gas leakage detection possibilities. Remedial action priority of wells decreases from Type 1 to Type 9 wells. Type 1 to Type 6 wells with status DA and PA require immediate attention, while Type 7 and Type 8 wells are low priority. A risk matrix used to prioritize corrective actions for legacy wells is proposed to categorize wells within an AoR based on penetrations, protections, and accessibility. The methodology involves data acquisition, well categorization into nine types, and determining CO 2 leakage pathways using well schematics and geospatial mapping. This approach is particularly useful for managing the integrity of legacy wells throughout the lifecycle of a Carbon Capture and Storage (CCS) project. A qualitative risk assessment of 94 wells within the AoR of the PSGC site identified 54 wells with high priority for corrective action due to penetration of the primary containment seal. The assessment utilizes color-coded maps to categorize well types and prioritize corrective actions, providing a comprehensive analysis. Schematics of wells penetrating the primary confining unit were drawn, and leakage pathways were identified. Details of all wells penetrating the confining zone are provided in the appendix, including information on well types, plugging, and casing status.

01 COAL, LIGNITE, AND PEAT↗