Search NASA⌕ Search

SEARCH · Search NASA

Results for “Injection pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Investigating the Combustion Performance of Dual Fuel Combustion with Diesel and Port Injected Hydrogen in a Large Bore Locomotive Engine

The heavy-duty transportation sector has primarily relied on conventional diesel combustion engines given their reliability and high thermal efficiency relative to spark ignition engines, but increased focus on reducing greenhouse gas emissions has led to investigation into alternative fuels. Gaseous hydrogen fuel has garnered a great deal of recent interest in the engine community given it has zero carbon, but hydrogen is not available at the scale and cost that petroleum fuels are currently available, and this is a barrier to adoption for industries that are looking to decarbonize their operations. Because of the fuel flexibility provided, dual fuel technology offers a pathway for some industries to adopt hydrogen as a fuel source while maintaining sufficient flexibility in times and locations where the new fuel is not yet available. This computational study investigates dual fuel combustion in a large bore locomotive engine architecture using direct injected diesel and port injected gaseous hydrogen fuel. With an optimal port fuel injection configuration from previous work, simulations of varying substitution ratio, compression ratio, manifold air temperature, diesel injection timing, and diesel injection pressure were performed to understand their effect on combustion performance. Results indicated that both increased substitution ratio and higher intake air temperature accelerates hydrogen flame propagation and can result in high peak cylinder pressures. Additionally, diesel injection timing and injection pressure were demonstrated as effective methods for controlling dual fuel combustion heat release rates.

ODonnell, Patrick Christopher↗

Investigation of pressure-controlled injection molding on the mechanical properties and embodied energy of recycled high-density polyethylene

Manufacturing with secondary feedstock has been identified as an effective strategy to improve plastic circularity. However, product quality inconsistencies arise due to variations in molecular weight, rheology, and mechanical properties. This work evaluates the processing of recycled high-density polyethylene using pressure-controlled injection molding with a focus on processing behavior and energy consumption. Further, the effects of injection velocity, packing pressure, and transfer position are benchmarked against a conventional velocity-controlled process. The experimental results show that the novel process control strategy significantly affects the mechanical properties, in-mold rheology, and energy consumption. Parts fabricated using pressure-controlled injection molding showed higher tensile properties due to increased macromolecular orientation. Additionally, reduced energy was used due to lower melt pressures required to completely replicate the cavity geometry. The results demonstrate the potential of the technology to support increased utilization of secondary feedstock and reduced carbon footprint.

36 MATERIALS SCIENCE↗

System Study: High-Pressure Coolant Injection 1998-2020

This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 25 U.S. commercial boiling water reactors. Demand, run hour, and failure data from 1998–2020 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

99 GENERAL AND MISCELLANEOUS↗

System Study: High-Pressure Safety Injection 1998-2020

This report presents an unreliability evaluation of the high-pressure safety injection system (HPSI) at 69 U.S. commercial nuclear reactors. Demand, run hours, and failure data from calendar years 1998–2020 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPSI results.

99 GENERAL AND MISCELLANEOUS↗

System Study: High-Pressure Coolant Injection 1998-2022

This report presents an unreliability evaluation of the high-pressure coolant injection (HPCI) system at 22 U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from 1998–2022 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

99 GENERAL AND MISCELLANEOUS↗

System Study: High-Pressure Safety Injection 1998-2022

This report presents an unreliability evaluation of the high-pressure safety injection system (HPSI) at 62 U.S. commercial operating nuclear reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hours, and failure data from calendar years 1998–2022 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. Highly statistically significant increasing trends were identified in both the HPSI system start-only unreliability and 8-hour mission unreliability.

99 GENERAL AND MISCELLANEOUS↗

System Study: High-Pressure Coolant Injection 1998-2024

This report presents an unreliability evaluation of the high-pressure coolant injection (HPCI) system at 22 U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from 1998 to 2024 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period and yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: High-Pressure Safety Injection 1998-2024

This report presents an unreliability evaluation of the high-pressure safety injection system (HPSI) at 62 U.S. commercial operating nuclear reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from calendar years 1998 to 2024 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10-year period and yearly estimates for system unreliability are provided for the entire active period. Statistically significant decreasing trends were identified in both the HPSI system start-only unreliability and 24-hour mission unreliability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A screening model for predicting injection well pressure buildup and plume extent in CO 2 geologic storage projects

We present a new screening model for predicting injection well pressure buildup and CO 2 plume migration for CO 2 geologic sequestration projects. The model requires only limited information and is quite accurate when compared to detailed simulation results. Such models can assist project developers during the early days of project planning (e.g., for 45Q related projects), and also help regulators perform simple checks against detailed numerical models. The screening model consists of two correlations: one for injectivity index in terms of the slope of the CO 2 fractional flow curve, and the second for total storage efficiency within the footprint of plume as a function of gravity number and slope of the CO 2 fractional flow curve. Using these two correlations, as well as a knowledge of some basic reservoir characteristics and estimates of fluid properties from standard correlations, the injection-well pressure buildup and CO 2 plume extent in the formation can be readily estimated. Finally, the new correlations show a good match with the results of the underlying simulations, and also provide good agreement with independent calculations for two example problems.

42 ENGINEERING↗

A physics-driven Σ-Y atomization model for heavy-duty engine simulations

The atomization of a liquid jet is a multi-scale and multi-physics problem of interest for many engineering applications. Particularly, it drives the fuel-oxidizer mixing and dictates the efficiency of combustion engines. High-fidelity multi-phase simulations remain challenging due to the excessive computational cost required to capture all the atomization scales. Thus, atomization models are necessary to represent sub-grid liquid structures. Here, in this work, a modified Σ-Y model in the context of Eulerian-Lagrangian Spray Atomization (ELSA) is used to transport the surface area density of the spray. The model's predictive performance is assessed under various operating conditions relevant to heavy-duty engines using the Engine Combustion Network (ECN) Spray C and Spray D research-grade injectors. The classic droplet collision formulation of the Σ-Y model alone does not replicate the response of the measured spray surface area to changes in injector, ambient pressure, and injection pressure, requiring individual tuning of the model's parameters. Instead, a transition between dense and dilute spray breakup mechanisms is proposed in terms of the average droplet spacing. The collision breakup mechanism represents the dilute spray, whereas the droplet size in the dense spray is driven by a competition between the integral scale of turbulence and the balance between the turbulent kinetic energy and the surface energy of the droplets. Such an approach minimizes the requirements for model tuning. Moreover, the role of the constants of a compressible standard k-ε RANS model is assessed in the injector's internal flow and external spray simulation framework, and an updated set is proposed. The results are validated against x-ray radiography and Ultra-Small Angle X-ray Scattering (USAXS) data and highlight the predictive capabilities of the proposed physics-driven Σ-Y model, which is compatible with engine simulation turnaround times.

42 ENGINEERING↗

Understanding the interplay between pilot fuel mixing and auto-ignition chemistry in hydrogen-enriched environment

The diesel-piloted dual-fuel compression ignition combustion strategy is well-suited to accelerate the decarbonization of transportation by adopting hydrogen as a renewable energy carrier into the existing internal combustion engine with minimal engine modifications. Despite the simplicity of engine modification, many questions remain unanswered regarding the optimal pilot injection strategy for reliable ignition with minimum pilot fuel consumption. The present study uses a single-cylinder heavy-duty optical engine to explore the phenomenology and underlying mechanisms governing the pilot fuel ignition and the subsequent combustion of a premixed hydrogen-air charge. The engine is operated in a dual-fuel mode with hydrogen premixed into the engine intake charge with a direct pilot injection of n-heptane as a diesel pilot fuel surrogate. Optical diagnostics used to visualize in-cylinder combustion phenomena include high-speed IR imaging of the pilot fuel spray evolution as well as high-speed HCHO* and OH* chemiluminescence as indicators of low-temperature and high-temperature heat release, respectively. Three pilot injection strategies are compared to explore the effects of pilot fuel mass, injection pressure, and injection duration on the probability and repeatability of successful ignition. The thermodynamic and imaging data analysis supported by zero-dimensional chemical kinetics simulations revealed a complex interplay between the physical and chemical processes governing the pilot fuel ignition process in a hydrogen containing charge. Hydrogen strongly inhibits the ignition of pilot fuel mixtures and therefore requires longer injection duration to create zones with sufficiently high pilot fuel concentration for successful ignition. Results show that ignition typically tends to rely on stochastic pockets with high pilot fuel concentration, which results in poor repeatability of combustion and frequent misfiring. In conclusion, this work has improved the understanding on how the unique chemical properties of hydrogen pose a challenge for maximization of hydrogen’s energy share in hydrogen dual-fuel engines and highlights a potential mitigation pathway.

33 ADVANCED PROPULSION SYSTEMS↗

The Case for Reducing Emissions from Heavy-Duty Off-Road Applications via Ducted Fuel Injection

Designers of heavy-duty diesel engines use a variety of techniques to improve efficiency and reduce pollutant emissions. Ducted fuel injection (DFI), high fuel injection pressures, optimized injection orifices, multiple injection sites, and oxygenated fuels are a few techniques used by designers to improve fuel/charge-gas mixtures within the combustion chamber to improve efficiency and emissions results. Ducted fuel injection (DFI) has been proven to substantially reduce soot for low- and mid-load conditions in heavy duty engines, without significantly increasing nitrogen oxides (NO x ). This study investigates the performance of DFI utilizing conventional diesel fuel and the potential the technique has for future research utilizing varieties of test fuels and operating parameter values. Optimization for high engine efficiency and low emissions will help facilitate DFI deployment for substantial environmental benefits in heavy-duty sectors where electrification and/or carbon-free fuels aren’t feasible.

33 ADVANCED PROPULSION SYSTEMS↗

DME-to-Propane Mixture Effects on a Light Duty Compression Ignition Engine

Fuels that can be produced in a sustainable manner are of high interest because they can provide an essential step toward net zero emissions vehicles. This study examines the combustion of two such fuels, Dimethyl Ether (DME) and propane, in a compression ignition, 4-cylinder, 2.2L engine running with mixtures of DME-to-Propane ranging of 100%-0%, 85%-15%, 75%-25%, and 65%-35% by weight. Testing was conducted at 2000rpm - 100Nm, an important representative point in the FTP certification cycle. For each fuel mixture, conditions tested include sweeps of boost, EGR and injection pressure. Here, tests are mainly conducted at a constant combustion timing with CA10 of -1 deg with respect to TDC, with an engine controller combustion feedback system based on in-cylinder sampling of pressure. Trends of NOx, HC, and CO are similar for the range of DME-to-propane, from 100%-0% to 75%-25%. Boost and injection pressures had the most notable impact on the heat release traces. Higher boost, from stoichiometric to lean resulted in approximately a 3-5% increase on cycle efficiency. Fuel injection pressures resulted in about 1% gain per 200bar. Results also illustrated that EGR is effective in reducing NOx but causes notable degradation of cycle efficiency. The emissions for DME-propane mixtures with 65%-35% had a different trend, with CO and HC exceeding the runs with lower propane content by 2 to 3-fold. As propane content increases, the pressure rise rates become higher, and with 65%-35% mixtures, rates easily exceed 12bar/deg. The increased rise rates correlate with early injection timings but the rates can be reduced, with higher boost and lower injection pressures. The result of the approach, however, leads to lower thermal efficiencies, decreasing efficiency by over 5% between neat DME and the highest propane ratios.

Combustion and combustion processes↗

Construction of a Direct Water-Injected Two-Stroke Engine for Phased Direct Fuel Injection-High Pressure Charging Investigations

The development of a water injected Orbital Combustion Process (OCP) engine was conducted to assess the viability of using the powerplant for high altitude NASA aircraft and General Aviation (GA) applications. An OCP direct fuel injected, 1.2 liter, three cylinder, two-stroke engine has been enhanced to independently inject water directly into the combustion chamber. The engine currently demonstrates low brake specific fuel consumption capability and an excellent power to weight ratio. With direct water injection, significant improvements can be made to engine power, to knock limits/ignition advance timing, and to engine NO(x) emissions. The principal aim of the testing was to validate a cyclic model developed by the Systems Analysis Branch at NASA Ames Research Center. The work is a continuation of Ames' investigations into a Phased Direct Fuel Injection Engine with High Pressure Charging (PDFI-ITPC).

Somsel, James P.↗

Coupled Thermo–Hydro–Mechanical Modeling of Hydro-Shearing Stimulation in an Enhanced Geothermal System in the Raft River Geothermal Field, USA

The Raft River Enhanced Geothermal System (EGS) demonstration project aims to improve the geothermal production by enhancing the reservoir permeability via shear stimulation in well RRG-9. In this paper, we performed a series of 3D thermo– hydro–mechanical (THM) simulations to investigate the influence of hydraulic and thermal effects on the development of this EGS. The model includes synthetic fracture populations based on borehole televiewer images and in-situ stress measurements from well RRG-9. Fracture permeability evolution is determined using an empirical permeability law developed from laboratory experiments. The model was calibrated by comparing the hydraulic response to field observations, including wellhead pressure, injection rate, and well injectivity. Particularly, we analyzed the enhancement of reservoir permeability and the spatial extent of the stimulation zone for the given injection schedule. Our results indicate that the permeability enhancement of fractured geothermal reservoir is caused by the combined effects of injection-induced cooling and fluid pressure increase. The decrease of temperature plays a dominant role in reactivation of natural fractures under the hydro-shearing mechanism, while the higher injection pressure promotes shear failure and enlarges the stimulation zone. Finally, for the specified extensional stress state, the model favors greatest permeability enhancement along the maximum horizontal principal stress, a moderate vertical enhancement, and a smaller gain along the minimum horizontal principal stress.

58 GEOSCIENCES↗

CFD Analyses and Jet-Noise Predictions of Chevron Nozzles with Vortex Stabilization

The wind computational fluid dynamics code was used to perform a series of analyses on a single-flow plug nozzle with chevrons. Air was injected from tubes tangent to the nozzle outer surface at three different points along the chevron at the nozzle exit: near the chevron notch, at the chevron mid-point, and near the chevron tip. Three injection pressures were used for each injection tube location--10, 30, and 50 psig-giving injection mass flow rates of 0.1, 0.2, and 0.3 percent of the nozzle mass flow. The results showed subtle changes in the jet plume s turbulence and vorticity structure in the region immediately downstream of the nozzle exit. Distinctive patterns in the plume structure emerged from each injection location, and these became more pronounced as the injection pressure was increased. However, no significant changes in centerline velocity decay or turbulent kinetic energy were observed in the jet plume as a result of flow injection. Furthermore, computational acoustics calculations performed with the JeNo code showed no real reduction in jet noise relative to the baseline chevron nozzle.

Dippold, Vance↗

Hydraulic Response to Thermal Stimulation Efforts at Raft River Based on Stepped Rate Injection Testing

The injection well stimulation project at the Raft River geothermal field tests the effect of long-term cold water injection and high pressure injection on well injectivity, improvements to which could reduce operating costs. The primary data for analysis and interpretation of the injection test are step-rate flow tests run before each new phase of the injection. These tests were analyzed using a combination of standard pump-test analytical solution methods and methods developed expressly for the observed conditions. The stepped rate injection tests, combined with long-term flow and pressure response data suggest that the well is located within a fractured formation of low transmissivity but high storativity. These calculated parameters appeared to increase with pressure during the first injection test and the higher values were reproduced during the second stepped rate test. Calculated transmissivity and storativity are on the order of 4E-5 m cm 2 and 1E-4 m Pa -1 , respectively. The apparent pressure dependence of fitted hydraulic parameters may reflect near-well fracture compliance that increased the effective radius of the wellbore during the first test. While the type curve fit analysis also suggests that the reservoir behaves as a uniformly fractured reservoir with a radial flow regime, the hydraulic parameters indicate that condition may exist only a very limited distance (<10 m) from the well. Longer-term pressure response suggests that flow in the system effectively reaches steady state in a period of less than a day, which may reflect pressure stabilization resulting from pressure-dependent permeability or a region of much higher permeability located with a few meters of the well. The transmissivity estimates obtained from this analysis, converted to approximate fracture density and aperture, provide useful constraints on the distance to which the thermal front may migrate from the well during the cold water injection phase of the stimulation project. We estimate that the cooling front will migrate less than a tenth of a kilometer over an approximately one-year injection period. Here, the effects of that cooling, however, may be substantial, because increases in permeability have maximum effect nearest the well.

cold water injection↗