Search NASA⌕ Search

SEARCH · Search NASA

Results for “KeV X-rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Novel soft x-ray multi-energy camera to study thermal plasmas on WEST

A multi-energy soft x-ray (SXR) pinhole camera has been built, calibrated and deployed on the WEST tokamak to aid the study of thermal plasmas. This novel imaging diagnostic technique employs a 2D pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. This innovation allows the simultaneous measurement of x-rays with space, time and energy resolution. Measurements at lower energy (2–6 keV) dominated by tungsten line emission are used to estimate the tungsten concentration and the plasma ΔZ eff . Measurements at higher energy (11–18 keV), where only continuum emission is present, are employed to infer the plasma electron temperature. Other applications of this powerful diagnostic include the determination of the plasma SXR centroid vertical position, characterization of tungsten UFOs and various real-time measurements.

electron temperature↗

Search for a heavy neutral lepton with the MAGNETO-𝜈 experiment using 241 Pu 𝛽 − decays

The MAGNETO-𝜈 experiment searches for keV-scale heavy neutral leptons (HNLs) through precise measurements of the 𝛽 − -decay spectrum of 241 Pu. We present spectra comprising a total of 194 million 𝛽 − decays recorded using decay energy spectrometry with metallic magnetic calorimeters, representing the most statistically precise measurement of 241 Pu 𝛽 − decay to date. The 𝛽-endpoint energy was determined using 𝛾 rays and x-rays from an external 133 Ba calibration source, yielding 𝑄 𝛽 = 22.273⁢ (33) ⁢keV. The measured spectrum shows no statistically significant deviation from the allowed 𝛽-decay model. From a subset of the high-statistics data, we set an upper limit on the mixing of an 11.5-keV HNL with the electron neutrino, |𝑈 𝑒⁢4 | 2 < 1.31 × 10 −3 at the 95% confidence level.

A ≥ 220↗

Continuum radiated power density $(P^{\textrm{C}}_{\textrm{rad}})$ and effective charge $(Z_{\textrm{eff}})$ estimates from multi-energy photon-counting measurements

Multi-energy soft x-ray pinhole cameras have been designed, built, calibrated, and operated at Madison symmetric Torus, Alcator C-Mod, and more recently at Tokamak a configuration variable and Tungsten Environment in Steady-State Tokamak (WEST), to measure plasma emission across multiple energy ranges. Here we describe a new methodology to estimate the local continuum radiated power density and the plasma effective charge (Z eff ) directly from photon-counting measurements of the line-free continuum emission (Bremsstrahlung and Radiative Recombination) in several energy bands between 11 and 18 keV. This capability is particularly valuable for confinement systems using metal plasma-facing components, where x-ray losses from interactions with the sputtered wall can represent a significant fraction of the total radiated power (P rad ). The approach leverages a well-characterized detector responsivity, modeled by a complementary error function, and interprets the differential multi-energy measurements between adjacent energy levels through the probability density function of a Gaussian distribution. The implementation of this diagnostic technique is currently under development on the WEST tokamak, aiming at the goal of providing real-time P rad and Z eff measurements during long-pulse operation (up to 1000 s) in the 2026 campaign.

WEST↗

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

X-ray Response of the Fully-Depleted, p-Channel SiSeRO-CCD

We present an X-ray characterization of a fully depleted, 725 $μ$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events, demonstrating that the SiSeRO amplifier preserves the intrinsic charge resolution of the CCD under multi-sample non-destructive readout. Characterization with a $^{241}$Am source extends the response to higher-energy photons, with reconstructed spectral features observed between 9-26 keV and the 59.5 keV $γ$ emission. These measurements, together with a muon-derived diffusion calibration, show that charge transport and diffusion are consistent with interactions spanning the full sensor depth. These results demonstrate that the SiSeRO CCD simultaneously achieves sub-electron noise performance and efficient charge collection in a thick, fully depleted silicon detector. This combination enables X-ray spectroscopy across a broad energy range while maintaining sensitivity to faint signals.

Cuevas-Zepeda, Julian↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Dose Measurement and Monte Carlo FLUKA simulations for the FE and FOE of the 27-ID HEX Beamline

The 27-ID High Energy Engineering X-ray Scattering (HEX) beamline, commissioned in 2024, operates within the Hard X-ray Scattering and Spectroscopy program at Brookhaven Lab’s National Synchrotron Light Source II (NSLS-II). The high energy spectrum at the HEX beamline extends up to several hundred keV, making it well suited for applications such as imaging large engineering samples, including fully assembled batteries, fuel cells, etc.

43 PARTICLE ACCELERATORS↗

Probing the axion-electron coupling with NuSTAR observations of galaxies

We search for the existence of ultralight axions coupling to electrons and photons using data from the NuSTAR telescope directed toward the galaxies M82, M87, and M31. We focus on electron bremsstrahlung and Compton scattering for axion production in stars, summing over the stellar populations found in the target galaxies when computing the axion luminosity. We then compute the hard x-ray signal that arises from the conversion of these axions to photons in each galaxy’s magnetic fields, inferred from analog galaxies in cosmological magnetohydrodynamic simulations. Analyzing NuSTAR data toward these galaxies between roughly 20 to 70 keV, we find no evidence for axions and set leading constraints on the combined axion-electron and axion-photon coupling at the level of |𝑔 𝑎⁢𝑒⁢𝑒 ×𝑔 𝑎⁢𝛾⁢𝛾 | ≲ 8.3 ×10 −27 GeV −1 for 𝑚 𝑎 ≲ 10 −10 eV at 95% confidence, with M82 providing the most stringent constraints.

Axion-like particles↗

Axion lines from nuclear de-excitations in galactic stellar populations

We show that mono-energetic axions are produced in abundance through nuclear de-excitations in nearby galaxies such as M87, which is the central galaxy of the Virgo cluster, and the starburst galaxy M82. If the axion couples to both nucleons and photons and is ultralight, then monochromatic hard x-ray signatures are induced by the subsequent axion-to-photon conversion in the magnetic fields permeating these systems. We search for evidence of such signals using NuSTAR data, focusing specifically on the 57 Fe de-excitation line at 14.4 keV, and we catalog other potentially relevant nuclear lines. We find no evidence for axions from M87 or M82 and set stringent constraints on the combined axion-nucleon and axion-photon coupling at the level of |𝑔 𝑎⁢𝑛⁢𝑛 × 𝑔 𝑎⁢𝛾⁢𝛾 | ≲ 1.1 × 10 −22 GeV −1 in the limit 𝑚 𝑎 ≲ 10 −10 eV at 95% confidence.

Ning, Orion [University of California, Berkeley, C↗

Microscopy X-ray imaging enriched with small angle X-ray scattering for few nanometer resolution reveals shock waves and compression in intense short pulse laser irradiation of solids

Understanding how laser pulses compress solids into high-energy-density states requires diagnostics that simultaneously resolve macroscopic geometry and nanometer-scale structure. Here we present a combined X-ray imaging (XRM) and small-angle X-ray scattering (SAXS) approach that bridges this diagnostic gap. Using the Matter in Extreme Conditions end station at LCLS, we irradiated 25 μm copper wires with 45 fs, 0.9 J, 800 nm pulses at 3.5 × 10 19 W/cm 2 while probing with 8.2 keV XFEL pulses. XRM visualizes the evolution of ablation, compression, and inward-propagating fronts with ∼ 200 nm resolution, while SAXS quantifies their nanometer-scale sharpness via the time-resolved evolution of scattering streaks. The joint analysis reveals that an initially smooth compression steepens into a nanometer-sharp shock front after t sh ≈ (18 ± 3) ps, consistent with an analytical steepening model and hydrodynamic simulations. The front reaches a velocity of c sh ≈ 25 k m / s and a lateral width of several tens of microns, demonstrating direct observation of shock formation and decay at solid density for the first time with few-nanometer precision. This integrated XRM–SAXS method establishes a quantitative, multi-scale diagnostic of laser-driven shocks in dense plasmas relevant to inertial confinement fusion, warm dense matter, and planetary physics.

Kluge, Thomas [Helmholtz-Zentrum Dresden-Rossendor↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

Resonant scattering at the center of the galaxy cluster PKS 0745-191 with XRISM

We report evidence of the resonant scattering effect at the center of the galaxy cluster PKS 0745-191 with XRISM. We analyzed XRISM/Resolve commissioning-phase observations of the distant cluster PKS 0745-191 ($z = 0.103$) with a $54$ ks exposure. The gain drift was corrected using the onboard modulated X-ray source (MXS), and spectra were extracted from all the pixels that were well illuminated by MXS, the core region (four central pixels, $\sim$100 kpc), and the surrounding region. A single-temperature collisional ionization equilibrium (CIE) model fits the full field-of-view spectrum with $kT \approx 6$ keV and a turbulent velocity of ${\approx}120$ km s$^{-1}$. From the core ($r < 50$ kpc) spectrum, we detected a ${\approx}22\%$ suppression of the Fe xxv He$\alpha$ resonance (w) line relative to the CIE prediction. We performed a Monte Carlo simulation to calculate the resonant scattering (RS) effect using radial profiles from Chandra data. The RS-inferred turbulence agrees with that by Resolve line-broadening, demonstrating that RS provides an independent and consistent constraint on ICM turbulence. These results highlight XRISM/Resolve’s potential for turbulence studies in galaxy clusters.

Astronomy and AstroPhysics↗

X‑ray Coherent Diffractive Imaging of Large Helium Nanodroplets Doped with Small Molecules

We report the first X-ray coherent diffractive imaging experiment on molecule-doped helium nanodroplets. It complements previous work, where we reported single-shot X-ray coherent diffractive imaging studies of Xe dopant clusters formed in 4He and 3He droplets. These noble gas clusters were used to visualize the impact of rotational excitation of the droplets on the spatial distribution of atomic dopants within the droplets, and to study the differences and connections between quantum and classical droplet rotational motion. Here, we expand our studies to the molecular dopants CF4, CHF3, CH3CN, and SF6, imaged with 1.5 keV photons. We find multiple Bragg spots in the diffraction patterns of molecule-doped droplets with radii of approximately 600 nm, which provide evidence that molecules form elongated clusters with preferential alignment along the angular momentum axis of the 4He droplets, in agreement with our previous results on the aggregation of Xe clusters on quantum vortices. Real-space reconstructions of molecular dopant cluster density profiles are obtained for droplets with smaller radii of approximately 300 nm. The diffuse images suggest the formation of low-density, potentially porous, molecular clusters upon aggregation at T = 0.4 K in 4He droplets. In the normal fluid 3He droplets, molecules aggregate into loose clusters on the droplets' equator, similar to previous observations for Xe atoms. Time-of-flight mass spectra reveal that the doped helium nanodroplet moieties fragment extensively into constituent atomic ions, producing only a small fraction of molecular fragment ions. The findings are discussed in the context of previously proposed schemes to use He droplets as potential tamper materials for ultrafast X-ray imaging experiments.

Feinberg, AlexandraJ↗

Staged Z-pinch experiment at the double-EAGLE pulsed power facility

The staged Z-pinch is a potential high-energy gain fusion concept where a high atomic number liner implodes on a deuterium target using a pulsed multi-MA current source. Over the past several years this concept has been studied on 0.5–1.0 MA facilities using Ar and Kr gas puffs injected at R = 1.2 cm. Neutron yield up to (2.5 ± 0.34) x 10 10 was measured, Ruskov et al (2023 IEEE Trans. Plasma Sci. 51 3310–6). Here, in this study, we present experimental results from the 4 MA, 110 ns current rise time Double-EAGLE facility at L3Harris (currently, Fisica Inc.) where a larger radius nozzle created gas density profiles peaked at R = 2.5 cm. Modeling with the MACH2 and FLASH codes indicates that the larger radius allows stronger acceleration of the liner plasma and generation of shock waves that preheat a target plasma layer next to the liner to temperatures $T_i >$1 keV. The resulting counter thermal pressure on the liner plasma limits the growth of the Magneto-Rayleigh–Taylor (MRT) instability at the liner-vacuum boundary and the implosion proceeds in a relatively stable manner. Near bang time the enormous target plasma thermal pressure smoothens the MRT perturbations developed during the earlier implosion stages. Time integrated x-ray pinhole images with cutoff energy of 100 eV confirm that a long (∼3 cm), stable and uniform high energy density plasma column is formed in the final implosion stage. Consistent neutron yield in the 10 10 –10 11 range was measured for both Ar and Kr liners imploding on a deuterium target.

Physics - Plasma physics↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗

Exploring high-intensity laser-driven secondary sources via high-order spectral pulse shaping for high-energy-density experiments

We present here the results of an investigation that aims to explore the impact of spectral pulse shaping on the generation of high-energy electrons (>1 MeV) and x rays (∼5–9 keV) using a high-intensity (I∼10 21 W/cm 2 ) laser system. The study involved a systematic scan of a broad parameter space in group delay dispersion and third-order dispersion, with variations up to 4 × 10 3 fs −2 and 6 × 10 4 fs −3 , respectively, to identify optimal conditions for enhancing secondary source yields. Several spectral phase conditions were found to significantly enhance the generation of hot electrons and x rays by amounts reaching up to 50% relative to the transform-limited pulse. The experiment, conducted at the Scarlet laser facility (800 nm, 5 J, 30 fs) at the Ohio State University, highlights the potential of spectral pulse shaping as a powerful tool for tuning secondary laser-driven sources. These findings are particularly relevant for advancing brighter x-ray and electron probes for high-energy-density science.

Physics - Plasma physics↗