At least 37 records · Page 2

Lifetime extension of legacy CEBAF LLRF hardware

A significant portion of the Low-Level Radio Frequency (LLRF) hardware in Jefferson Lab’s CEBAF is from the original construction of the facility using 1980’s CAMAC technology. Of the fifty-three zones in CEBAF, thirty-six of them are legacy hardware. The age of the legacy system has led to difficulties in maintaining the hardware due to parts going obsolete without suitable drop in replacements. Continued operation of the legacy system is required as the installation of LLRF 3.0 systems is costly and cannot be completed in a short period of time with the available resources. The most pressing failure in the legacy system was a failing buffer card, which is responsible for communication between the EPICs network and individual RF control modules. A new buffer card was designed as a transparent, drop in, replacement so that upgrades are simply a matter of swapping the existing legacy hardware. This buffer card upgrades a single point failure component and promises to extend the operable lifetime of CEBAF’s legacy systems.

Accelerator Physics↗

Calibration and Measurement techniques in the LLRF systems of the Fermilab PIP-II Linac

he PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems are a based on two different hardware platforms controlling a variety of cavity types and resonance control systems including temperature, pneumatic and piezzo tuners. The various calibrations required prior to beam operation include, signal power, gradient, amplifier characterization, cavity Q measurement and detune constants. Measurements such as piezzo capacitance, cavity piezo transfer function help in determining tuner health and in devising microphonics control strategies. These measurement and calibration methods of the PIP-II LLRF system are discussed here.

Varghese, P.↗

Timing and Synchronization in the LLRF systems of the Fermilab PIP-II Linac

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

Varghese, Philip↗

Baseband Digital Network Analyzer Upgrade for LLRF Controllers

Digital Network Analyzers (DNA) have been implemented in many Low-Level Radio Frequency (LLRF) systems, notably NSLS-II and CERN, to help tune feedback loops. DNA characterizes feedback loops by measuring the frequency-dependent magnitude and phase transfer functions. It enables the measurement of open loop gains, gain/phase margins, and loop delays to help fine-tune feedback loops. An FPGA-based DNA has been developed and integrated into the current Relativistic Heavy Ion Collider (RHIC) LLRF infrastructure. Its performance has been tested with an implementation of one-turn delay feedback (OTFB) on the bench to maximize gain and stability. The DNA has been used to characterize a RHIC 28 MHz cavity in a RHIC Accelerator Physics Experiment (APEX) to test transient beam loading compensation strategies.

43 PARTICLE ACCELERATORS↗

RF Digitizer for EIC LLRF

With the shutdown of Relativisitc Heavy Ion Collider (RHIC) in FY26, the former RHIC facility will be upgraded to the new Electron-Ion Collider (EIC). An RF Digitizer for the EIC LLRF system has been developed and tested on a RHIC 197 MHz cavity in Q2 2026 for a baseline per formance. Firmware and software has been developed and validated during the 197 MHz cavity test. Preliminary data from the cavity test shows phase noise performance signifi cantly better than the RHIC LLRF system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A deterministic, gigabit serial timing, synchronization and data link for the RHIC LLRF

A critical capability of the new RHIC low level rf (LLRF) system is the ability to synchronize signals across multiple locations. The 'Update Link' provides this functionality. The 'Update Link' is a deterministic serial data link based on the Xilinx RocketIO protocol that is broadcast over fiber optic cable at 1 gigabit per second (Gbps). The link provides timing events and data packets as well as time stamp information for synchronizing diagnostic data from multiple sources. The new RHIC LLRF was designed to be a flexible, modular system. The system is constructed of numerous independent RF Controller chassis. To provide synchronization among all of these chassis, the Update Link system was designed. The Update Link system provides a low latency, deterministic data path to broadcast information to all receivers in the system. The Update Link system is based on a central hub, the Update Link Master (ULM), which generates the data stream that is distributed via fiber optic links. Downstream chassis have non-deterministic connections back to the ULM that allow any chassis to provide data that is broadcast globally.

43 PARTICLE ACCELERATORS↗

LLRF System for the CEBAF Separator Upgrade

The Continuous Electron Beam Accelerator Facility (CEBAF) energy upgrade from 6 GeV to 12 GeV includes the installation of four new 748.5 MHz normal conducting deflecting cavities in the 5th pass extraction region. This system will work together with the existing 499 MHz RF Separator in order to allow simultaneous delivery of the beam to four CEBAF experimental halls. The RF system employs two digital LLRF systems controlling four cavities in a vector sum. Cavity tune information of the individual cavities is also obtained using a multiplexing scheme of the forward and reflected RF signals. In this paper we will present detailed LLRF design and the current status of the CEBAF 748.5/499 MHz beam extraction system.

Plawski, Tomasz E.↗

The LCLS-II LLRF System

The SLAC National Accelerator Laboratory is planning an upgrade (LCLS-II) to the Linear Coherent Light Source with a 4 GeV CW superconducting (SCRF) linac. The SCRF linac consists of 35 ILC style cryomodules (eight cavities each) for a total of 280 cavities. Expected cavity gradients are 16 MV/m with a loaded Q L of ~ 4x10 7 . The RF system will have 3.8 kW solid state amplifiers driving single cavities. To ensure optimum field stability a single-source single-cavity control system has been chosen. It consists of a precision four-channel cavity receiver and RF stations (Forward, Reflected and Drive signals). In order to regulate the resonant frequency variations of the cavities due to He pressure, the tuning of each cavity is controlled by a Piezo actuator and a slow stepper motor. In addition the system (LLRF-amplifier-cavity) is being modeled and cavity microphonic testing has started. This paper describes the LLRF system under consideration, including recent modeling and cavity tests.

43 PARTICLE ACCELERATORS↗

SRF Cavity Emulator for PIP-II LLRF Lab and Field Testing

There are many stages in the LLRF and RF system development process for any new accelerator that can take advantage of hardware emulation of the high-power RF system and RF cavities. LLRF development, bench testing, control system development and testing of installed systems must happen well before SRF cavities are available for test. The PIP-II Linac has three frequencies of SRF cavities, 162.5 MHz, 325 MHz and 650 MHz and a simple analog emulator design has been chosen that can meet the cavity bandwidth requirements, provide tuning errors to emulate Lorentz force detuning and microphonics for all cavity types. This emulator design utilizes a quartz crystal with a bandwidth of 65Hz at an IF of ~ 4 MHz, providing a Q of ~ 1.3 x 10^7 at 650MHz. This paper will discuss the design and test results of this emulator.

43 PARTICLE ACCELERATORS↗

LLRF Commissioning of the new CEBAF 100 MeV Cryomodule

Commissioning of the 100 MeV cryomodule (CEBAF acronym C100) is part of the CEBAF energy upgrade to 12 GeV at Jefferson Lab. LLRF commissioning includes field control, cavity interlocks, resonance controls (Stepper Motor and Piezo tuner) and operational software. All the above mentioned systems and software are calibrated and tested on the bench and in test platforms prior to installation. Once installed and connected to the cryomodule, the system supports cavity commissioning (Emax, Qo etc.). In addition the LLRF system is calibrated (gradient and RF power), optimized (system gains and set points) and functionality is tested for operability. This poster describes the detailed description of various stages of commissioning of first 100 MeV cryomodule.

Bachimanchi, Ramakrishna↗

LLRF design for the HINS-SRF test facility at Fermilab

The High Intensity Neutrino Source (HINS) R&D program requires super conducting single spoke resonators operating at 325 MHz (SSR1). After coupler installation, these cavities are tested at the HINS-SRF facility at Fermilab. The LLRF requirements for these tests include support for continuous wave and pulsed mode operations, with the ability to track the resonance frequency of the tested cavity. Real-time measurement of the cavity loaded Q and Q{sub 0} are implemented using gradient decay techniques, allowing for Q{sub 0} versus E{sub acc} plots. A real time cavity simulator was also developed to test the LLRF system and verify its functionality.

43 PARTICLE ACCELERATORS↗

Lessons Learned from PEP-II LLRF and Longitudinal Feedback

The PEP-II B-Factory collider ended the final phase of operation at nearly twice the design current and 4X the design luminosity. To highlight the evolution from the original conceptual design through to the 1.2E34 final machine we choose one example each from the broadband feedback and from the LLRF system. They illustrate the original design estimation missed some very significant details, and how in the course of PEP-II operation unexpected difficulties led to significant insights and new approaches which allowed higher machine performance. We present valuable 'lessons learned' which are of interest to designers of next generation feedback and impedance controlled LLRF systems.

43 PARTICLE ACCELERATORS↗

USPAS Digital Low-Level RF firmware and software suite (uspas_llrf) v1.0

The USPAS Digital Low-Level RF firmware and software suite was originally developed for the USPAS 2023 LLRF course, for demonstrating the close loop RF control on the BerkeleyLab Marble FPGA carrier and Zest digitizer platform in controlling the RF field for various accelerators. The suite features Register-transfer level (RTL) designs for the board-support layer, digital signal processing and verification test benches, system-on-chip architecture, and Experimental Physics and Industrial Control System (EPICS) support, utilizing a open-source tool chain.

Du, Qiang↗

Design and Implementation of the LLRF System for LCLS-II

The SLAC National Accelerator Laboratory is building LCLS-II, a new 4 GeV CW superconducting (SCRF) linac as a major upgrade of the existing LCLS. The SCRF linac consists of 35 ILC style cryomodules (eight cavities each) for a total of 280 cavities. Expected cavity gradients are 16 MV/m with a loaded QL of ~ 4 x 10⁷. Each individual RF cavity will be powered by one 3.8 kW solid state amplifier. To ensure optimum field stability a single source single cavity control system has been chosen. It consists of a precision four channel cavity receiver and two RF stations (Forward, Reflected and Drive signals) each controlling two cavities. In order to regulate the resonant frequency variations of the cavities due to He pressure, the tuning of each cavity is controlled by a Piezo actuator and a slow stepper motor. In addition the system (LLRF-amplifier-cavity) was modeled and cavity microphonic testing has started. This paper will describe the main system elements as well as test results on LCLS-II cryomodules.

Serrano, Carlos↗

LLRF Control of High Loaded-Q Cavities for the LCLS-II

The SLAC National Accelerator Laboratory is planning an upgrade (LCLS-II) to the Linear Coherent Light Source with a 4 GeV CW Superconducting Radio Frequency (SCRF) linac. The nature of the machine places stringent requirements in the Low-Level RF (LLRF) system, expected to control the cavity fields within 0.01 degrees in phase and 0.01% in amplitude, which is equivalent to a longitudinal motion of the cavity structure in the nanometer range. This stability has been achieved in the past but never for hundreds of superconducting cavities in Continuous-Wave (CW) operation. The difficulty resides in providing the ability to reject disturbances from the cryomodule, which is incompletely known as it depends on the cryomodule structure itself (currently under development at JLab and Fermilab) and the harsh accelerator environment. Previous experience in the field and an extrapolation to the cavity design parameters (relatively high Q_{L}c≈ 4×10⁷ , implying a half-bandwidth of around 16 Hz) suggest the use of strong RF feedback to reject the projected noise disturbances, which in turn demands careful engineering of the entire system.

43 PARTICLE ACCELERATORS↗

Report on LLRF

The RF system for the Pohang Light Source (PLS) storage ring was upgraded for the PLS-II project to improve from 2.5GeV/200mA to 3.0GeV/400mA. The key points of machine upgrade are to implement superconducting RF (SRF) cavities and digital low-level RF (LLRF) system. Two SRF cryomodules with cryogenic system were installed and tested during summer shutdown period of 2012. And the user service beam operation has started with the SRF system since 2013. The RF system is operating at 3.0GeV/200mA with two superconducting RF (SRF) cavities.

Source record↗

LLRF SYSTEM REQUIREMENTS FOR SRF DRIVEN NEXT GENERATION LIGHT SOURCES

A number of next generation light sources have been proposed which make use of superconducting radio frequency (SRF) cavities as the primary accelerating elements. The cavities are used in injectors, standard linac configurations and energy recovered linac configurations. We will describe the general requirements for the low level RF systems used in next generation light sources which are driven by SRF linacs. The talk will describe the general schemes used for each of these types of machines. It will describe the general requirements for the LLRF systems for operations as well as for commissioning the cavities once they are installed in the accelerator. Operational issues and challenges will also be discussed. Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S. Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce this manuscript for U.S. Government purposes. # powers@jlab.org

Powers, Thomas↗

Testing the Common Platform LLRF with a 197 MHz NCRF Cavity

The Common Platform is the hardware that will support the new LLRF platform to be used for the Electron-Ion Collider. The Common Platform features a carrier board that is used to interface with a variety of daughter for different applications. This paper details the testing that was done using the Common Platform and an RF Digitizer Daugther Board. Firstly, the firmware and software development is discussed followed by a description of the controls algorithms used in the testing. Then, testing and verification of the platform with a 197 MHz NCRF cavity is discussed. The paper concludes with results from the testing and the path forward.

42 ENGINEERING↗