Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lab Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Lab Home Testing of Residential Isolation Space Control to Minimize Infectious Disease Transmission in Existing Single-Family Homes

Existing evidence strongly suggests that viral infectious diseases can be transmitted via an airborne route across distances in indoor environments. Accordingly, the risk of airborne transmission within homes should be managed. The public health emergency associated with SARS-CoV-2 makes controlling airborne transmission of respired viruses in indoor environments critical, especially in poorly ventilated indoor environments. The effectiveness of engineering interventions requiring minor efforts that create a negative-pressure isolation zone (IZ) for a contagious person has yet to be tested for existing residential homes. To mitigate the risk of airborne virus transmission and maximize health protection for the population in existing single-family homes, the relative effectiveness of several control strategies are investigated in this report. While very high-efficiency MERV filtration, high ventilation rates, and other controls can help be effective, most occupants are not likely to have the time or means for advanced measures found in hospitals. This project focused on testing relatively simple efforts that utilize existing or easy to acquire materials and simple processes.

30 DIRECT ENERGY CONVERSION↗

Intern Poster - Characterizing Wildland Fire Conditions for Lab-Scale Testing of Advanced Conductors

As the demand for energy increases each year, electric utilities face the challenge of delivering more power than before. Current transmission/distribution networks have proved reliable in the past but are physically unable to meet higher energy demands. Traditional overhead conductor cables (such as Aluminum Conductor Steel Reinforced (ACSR)) are limited in their ability to hold more voltage due to increased temperatures and resulting sag. When the cable sags, it comes closer to the ground, violating clearance standards and presenting an environmental risk. Newly developed advanced conductors, aluminum conductors with carbon fiber composite cores (instead of steel) mitigate this risk. Advanced conductors are engineered to perform in higher operating temperatures without sagging, thus possessing higher capacity potential. Regardless, utilities are hesitant to adopt this new technology due to scarcity of use data. The largest looming risk for utilities is wildland fires. There is little to no data on how advanced conductors perform in the event of a wildland fire. To address these concerns, this project aims to test the mechanical performance of advanced conductors in these conditions, providing utilities use data for their reference. The initial steps of the project will be to design and construct a fire table apparatus to reproduce wildland fire conditions, calculate proper parameters for this testing, and analyze the impact mathematically. After completing these actions, the next steps will be to test the advanced conductors in the laboratory fire chamber.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible Natural Gas/Hydrogen CHP System

This project included design, development, and demonstration of a cost-effective and scalable, unique-to-the-industry 2.0 MWe fuel-flexible Caterpillar G3516 CHP genset that can run on 100% hydrogen, 100% natural gas, and up to 25% blends of hydrogen in natural gas (volume basis). This was accomplished based on over two years of extensive R&D work done on a single-cylinder engine for developing innovative hydrogen fueling, combustion, air, and electronic control systems design and strategies. Findings from the single-cylinder engine work were scaled up and applied for modifications of and lab testing and development of a 2.0 MWe 16-cylinder G3516 fuel-flexible engine-genset and electronic controls systems. During this testing and development in the engine lab, the genset was run on 100% hydrogen, 100% natural gas, and up to 25% blends of hydrogen in natural gas (volume basis) and its steady-state and transient performance and emission were documented.

03 NATURAL GAS↗

Reliability Evaluation of Bifacial and Monofacial Glass/Glass Modules with EVA and non-EVA Encapsulants

The market share for bifacial modules is projected to be doubled from 30% to 60% in the next ten years. For the monofacial crystalline silicon glass/backsheet (G/B) modules, extensive reliability data has been available for over 40 years. However, practically little/no long-term field or accelerated reliability test data is available for the new generation glass/glass (G/G) bifacial modules and glass/transparent (G/T) bifacial modules. Therefore, the primary motivation of this project was to identify the reliability strengths and weaknesses of new generation G/G modules compared to G/B modules. In this 3-year project, the goal was to objectively recommend the best construction materials for the new generation G/G (bifacial) modules through a systematic experimental approach with appropriate tasks including: Evaluation of field retrieved old-generation G/G modules; Inspection of new-generation G/G modules installed in the plants; Evaluation of new-generation G/G, G/B and G/T modules using EAST (Extended Accelerated Stress Testing), CAST (Combined Accelerated Stress Testing) and FAST (Field Accelerated Stress Testing); and, dynamic literature search and review. Major accomplishments and outcomes of this project are: Accomplishments: Evaluated more than 60 field retrieved modules and constructed and characterized more than 135 mini-modules with three substrate types (G, B, and T), two encapsulant types (EVA and POE), and two cell types (monofacial and bifacial) as well as evaluated more than 30 commercial G/G and G/B modules; Subjected all the modules to multitude characterization tests and various indoor and outdoor accelerated stress tests including FAST (Field Accelerated Stress Testing), EAST (Extended Accelerated Stress Testing), and CAST (Combined Accelerated Stress Testing) to identify and correlate the failure modes in both field and lab tests. Outcomes: Based on the accelerated test results and handling/mounting experience obtained in this project, the recommended best construction for the glass/glass modules is: “Framed GG modules with cut-cells and POE encapsulant (UVpass front; UVpass back).” However, from a statistical and manufacturing point of view (along with stakeholders surveys), the following cautionary notes are added to the above-mentioned recommendation: (i) Cut cells could introduce a higher level of manufacturing issues, including a higher number of cell interconnects; (ii) POE encapsulant is more expensive than EVA and could present a delamination risk and lower throughput during manufacturing due to lower adhesion strength. Other encapsulants, such as coextruded EPE (EVA/POE/EVA), are also recommended to be investigated. The potential public benefit of the proposed project is to present the strengths and weaknesses of glass/glass modules, so an informed procurement decision can be made.

14 SOLAR ENERGY↗

Angle of Incidence Characterization of Six Laminated Solar Cells for 2020 DTU Fotonik Inter-Laboratory Comparison Study

Photovoltaic energy prediction models include functions or modifiers to account for sun angle reflection losses. These functions may be known interchangeably as Angle of Incidence (AOI) or Incident Angle Modifier (IAM). While standards exist, there is no universally accepted single best practice for developing these functions. They can be generated through characterization of representative modules or single cells, in natural sunlight or indoors using simulated light sources. Repeatability of measurements and the viability of cross-laboratory comparisons are critical to confidence in validation of both methods. To investigate the differences between methods and labs, The Technical University of Denmark (DTU) initiated an international round-robin test comparison between several key test labs with AOI measurement capability. A total of six minimodules were provided in three different cell/interconnect/backsheet combinations. Sandia characterized these minimodules using methods developed over two decades specifically for the outdoor characterization of full-size photovoltaic modules. This report documents the characterization results, summarizes key observations and tabulates the processed data for comparison to results provided by other characterization labs.

14 SOLAR ENERGY↗

Evaluation of Additively Manufactured Monolithic SiC and SiC Ceramic Matrix Composites for Concentrating Solar Receiver Applications

Supported by an award from the Solar Technology Office, US Department of Energy, GE Aerospace Research in collaboration with Heliogen Holdings Inc, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR). We report the results of our study of the effective heat transfer characteristic of several candidate structure motifs, or feature geometries, made of SiC via additive manufacturing in a simulative laboratory test. The SiC structure motifs studied include different permutations of three-dimensional periodic lattices and defined shapes. The solar-thermal simulating laboratory test setup is constructed using a 4kW CO2 laser system with beam shaping optics to apply radiative heating power on one face of 2”-diameter cylindrical feature specimens representing the structure motifs of interest for receiver element design. Using the test setup, simulative test conditions representative of a concentrated solar flux of up to ~2000 suns could be achieved in the lab tests under varying air flow through the test structure. A numerical analysis scheme is developed to extract an effective or compound heat transfer coefficient representative of the test structure under steady-state heat flow conditions.

14 SOLAR ENERGY↗

Determination of Arsenic Content in Water Using a Silver Coordination Polymer

In this report, we describe a practical method for the colorimetric determination of dissolved inorganic arsenic content in water samples, using a silver coordination polymer as the sensing material. We demonstrate that a crystalline polymer framework can be used to stabilize silver(I) ions, greatly reducing both photosensitivity and water solubility, while still affording sufficient reactivity to detect arsenic in water samples at low parts-per-billion (ppb) levels. Test strips fabricated with the silver-based polymer are shown to be effective for field tests of groundwater under real-world operating conditions and display performance that is competitive with commercially available mercury-based test strips. Spectroscopic methods are also used to probe the reaction products formed, in order to better understand the sensing mechanism. Thus, our work provides the foundation for an improved field test that could be deployed to help manage groundwater usage in regions where arsenic contamination is problematic but sophisticated lab testing is not readily available.

36 MATERIALS SCIENCE↗

The Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC)

The Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC) is a 6-ft wave energy device that turns seawater into drinking water. It is designed for rapid deployment in disaster response scenarios where fresh water is limited. Featuring both hydraulic and electric power takeoff systems, HERO WEC has undergone two ocean deployments at Jennette's Pier on the Outer Banks of North Carolina in addition to extensive in-lab testing. The research provides practical insights into the real-world challenges of wave energy conversion beyond modeling and dry-lab environments. Attendees will develop an understanding of the practical considerations for deploying wave energy devices and the lessons learned from real-world HERO WEC deployments.

16 TIDAL AND WAVE POWER↗

The LED calibration systems for the mDOM and D-Egg sensor modules of the IceCube Upgrade: Design, production, testing and use in module calibration

The IceCube Neutrino Observatory, instrumenting about 1 km 3 of deep, glacial ice at the geographic South Pole, is due to be enhanced with the IceCube Upgrade. The IceCube Upgrade, to be deployed during the 2025/26 Antarctic summer season, will consist of seven new strings of photosensors, densely embedded near the bottom center of the existing array. Aside from a world-leading sensitivity to neutrino oscillations, a primary goal is the improvement of the calibration of the optical properties of the instrumented ice. This calibration will be applied to the entire archive of IceCube data, improving the angular and energy resolution of the detected neutrino events. For this purpose, the Upgrade strings include a host of new calibration devices. Aside from dedicated calibration modules, several thousand LED flashers have been incorporated into the photosensor modules. We describe the design, production, and testing of these LED flashers before their integration into the sensor modules as well as the use of the LED flashers during lab testing of assembled sensor modules.

Analogue electronic circuits↗

PACT Center: Perovskite PV Accelerator for Commercializing Technologies (Final Technical Report)

The Perovskite PV Accelerator for Commercializing Technologies (PACT) center was established in July 2021 as a national resource to accelerate the commercialization of perovskite photovoltaic (PV) technology in the United States. Since its inception, PACT has been led by Sandia National Laboratories (Sandia) in partnership with the National Laboratory of the Rockies (NLR), formerly known as NREL. From FY20-FY23, Los Alamos National Laboratory (LANL), CFV Labs, Black & Veatch (B&V), and the Electric Power Research Institute (EPRI) were part of the project team. LANL brought expertise in perovskite PV device designs and processing, CFV Labs (now GroundWork Renewables) provided initial indoor and outdoor measurement hardware technology, B&V led the initial effort on perovskite PV bankability, and EPRI worked on reviewing testing standards, identifying commercialization gaps, and helping to run PACT’s Industry Advisory Board, a group including representatives from commercial testing labs, independent engineering firms, insurance companies, state regulators, and electric utilities. To source perovskite PV module samples, PACT contracted with the University of North Carolina (UNC), the University of Toledo, the University of Washington, and SLAC/Stanford University to provide a steady stream of research-grade perovskite mini modules, enabling protocol development in advance of commercial module availability. The project period ran from July 1, 2021, through December 31, 2025, including a No Cost Extension. Starting in FY25, the project was continued as a Core Capability in the Lab Call portfolio and continues at a reduced budget with only Sandia and NLR as funded recipients. Notably, starting in FY25 PACT expanded its scope beyond MHP modules to accept all emerging PV mini module technologies for testing, including organic PV (OPV) and all-thin-film tandems, with the aim of supporting commercialization across the broader emerging PV ecosystem. With this change in scope the program was renamed the PV Accelerator for Commercializing Technologies, dropping perovskite from the name.

14 SOLAR ENERGY↗

ZIPPER: Zonal isolation with plug and perf in enhanced reservoirs (Final Technical Report)

Modern multistage hydraulic stimulation treatments in cased wellbores require an effective method of isolating stages between treatments. A commonly used method in the oil and gas industry, plug and perf, is not currently viable for Enhanced Geothermal Systems (EGS) due to limitations of a critical component of the system – the ball drop (flow through) frac plug. Commercially available ball drop frac plugs do not meet the temperature or wellbore diameter requirements needed for use in EGS stimulations. For example, one particular drillable bridge and frac plug line from a large tool developer is only rated to 175 °C, while another is only available up to casing sizes of 5 ½” and rated up to 204 °C. We developed, prototyped, and field tested an upgraded ball drop frac plug to meet the requirements of EGS stimulations, including high-temperature (225+ °C), differential pressure (6000+ psi), and wellbore diameters ranging from 6 5/8” to 10 5/8”. We focused on designs and materials to optimize drillability, a key cost driver in plug and perf systems. The primary objective was to upgrade a drillable frac plug (currently rated to a temperature of 175°C and a pressure of 10,000 psi in 7” casing) to withstand temperatures of 225+°C. The upgraded frac plug was tested in the laboratory as well as in a field trial at a geothermal field. Engineering design and fabrication of the new plug was completed in 2019. Lab testing, validation, and qualification of the plug was completed in 2020. Ultimately the plug was successfully run during a multistage stimulation treatment in a fully horizontal EGS well in 2022. Prior to this project, a ball-drop, flow-through stimulation plug had never been used in a geothermal well. At the conclusion of this project, three different types of zonal isolation plugs were evaluated under full-scale operating conditions across 16 stimulation treatment stages in a first-of-a-kind EGS project called Project Red. This trial included the newly designed high-temperature, large-diameter plug. The plugs met all of 5 the technical requirements for commercial viability. Project Red has since been fully commissioned and is generating electricity on the Nevada grid - the first EGS project to successfully deliver power to the grid in the US.

15 GEOTHERMAL ENERGY↗

Coatings for CSP Lifetime

The feasibility and performance of tower-technology-based concentrated solar power (CSP) is highly dependent on the efficiency of the energy transformation from sun to heat at the receiver. The higher the solar absorptivity of the receiver coating, the higher the efficiency of the plant as a whole. BrightSource Energy (BSE) has developed a series of High-Performance Coating (HPC) systems in order to achieve high absorptivity over the plant lifetime (25-35 years). This requires stable coatings that are easily applicable on the large receiver surface and will maintain their optical properties under intense solar flux and thousands of heating and cooling cycles in desert conditions. Different coating formulations are required according to the differing plant conditions: receiver materials, operating conditions (temperatures, daily cycles, etc.), and environmental conditions. BSE also developed a coating for the next generation of CSP receivers, such as those being under DOE’s CSP Gen3 program, which will be operated with high temperature heat transfer fluids at temperatures of up to 800°C, which is significantly hotter than the operating temperature of current systems. Once the coating is formulated, the next challenge is evaluating its lifetime properties. BSE has found several independent failure modes that impact HPC absorptivity degradation: • Decrease in HPC optical properties due to oxidation in the receiver tubes surface below the HPC; • HPC film deterioration due to cycling of temperatures and humidity due to daily operation startup and shutdown as well as changing ambient conditions; • Mechanical degradation due to erosion by sand and wind. Existing test methods examine various aspects independently, but do not provide a combined accelerated lifetime result. Creating such a combined test suite, with a way to interpret the results to predict the coating’s projected lifetime, was the ultimate goal of this project. The project was divided into three major workstreams: lab testing (individual failure mode tests and combined failure mode tests); developing a theoretical model for aging; and validation of the test apparatus via on-sun testing in near real-world conditions at CIEMAT-PSA. Developing a test apparatus that accurately controlled the temperature while also introducing the desired solar flux proved more challenging than expected. While in the end we did succeed in creating a test apparatus that can control temperature, solar flux, and humidity, the results did not appear to accelerate the lifetime of the samples as desired. We suspect that to properly accelerate the samples we must also subject the samples to increased amounts of oxygen. Similarly, while we successfully created a combined model that is publicly available, we were unable to validate it sufficiently to feel comfortable recommending it as a general guideline.

14 SOLAR ENERGY↗

Diagnostic Testing for COVID-19 Bridging Study for QIAamp Viral RNA Extraction vs Beckman RNAdvance vs Thermofisher MagMAX

This report describes testing that was performed by LANL’s Biological Agent Testing Lab (BATL) to validate modifications to the CDC EUA 2019-Novel Coronavirus (2019- nCoV) Real-Time RT-PCR Diagnostic Panel (EUA-CDC-nCoV-IFU). BATL intends to implement the modifications to increase thoughput for daily testing . BATL validated the viral RNA extraction process, using the orignial component, QIAamp Viral RNA Mini Kit (Cat # 52906) and the new components, Beckman Coulter magnetic 96-well plate RNAdvance Viral kit (Cat # C63510), Thermofisher MagMAX Viral/Pathogen Nucleic Acid Isolation Kit (Cat # A48310). Equivalency was demonstrated between the original component and the Beckman Coulter magnetic 96-well plate RNAdvance Viral kit (Cat # C63510). Equivalency was also demonstrated between the original component and the Thermofisher MagMAX Viral/Pathogen Nucleic Acid Isolation Kit (Cat # A48310). Subsequently, substitution of the original component with either of these kits for viral RNA extraction increased BATL’s extraction capability from 100 samples per day to 279 samples per day.

59 BASIC BIOLOGICAL SCIENCES↗

Regal Beloit Final Technical Report

The original project proposal submitted from NovaTorque Inc (NovaTorque) in 2016 was to improve the existing motor with 95% efficiency by reducing the losses by 21% to achieve 96%. A few months after the proposal was submitted, NovaTorque lost funding and went out of business. The assets of NovaTorque were then acquired by Regal Beloit Corporation (“Regal Beloit” or “Regal”). When the NovaTorque proposal was selected, the project was transferred to Regal Beloit. Once we had production samples from the new Regal production line, they were tested at the Regal Beloit test lab in Wausau, WI. The original NovaTorque motor had an efficiency of 95%, but when the technology was transferred to Regal Beloit, there were multiple manufacturing improvements made, even though the basic electromagnetic design did not change. The test results in Wausau showed that the motors made at the Regal Beloit plant had an efficiency of 96%. Since the goal of the project was to reduce the losses by 21%, a new efficiency target of 96.8% became the project objective. In the first budget period, motors were tested to get the baseline performance. We then used FEA modeling with ANSYS Maxwell to model the existing motor to get correlation between the FEA simulations and the actual test results. Once the model was validated, we evaluated some changes that could be made to the stator to reduce the losses and improve efficiency without changing the rotor or stator housing, keeping the modifications easy to implement. The changes were primarily in the area of making the stator axially shorter and adding Soft Magnetic Composite (SMC) tooth tips. In the second budget period, we proceeded to design and build the new stator that was identified above and identified additional improvements in the process that included a stator machining modification and the use of rectangular wire. When we actually built the motor, the choice of rectangular wire turned out to be a problem. The wire was made by squishing round wire to get the rectangular shape, which caused work hardening, making the wire too stiff to make the desired coils. We shifted to annealed square wire which was better, but we still could not maintain the proper coil envelope. The result was that we had reduced cross section area for stator laminations. We also had to have a radial offset resulting in a radial misalignment between the stator and rotor because of the oversized coils. After the motor was completed, it was shipped to Texas A&M University for testing. With the loss of flux from these issues, the measured motor efficiency was only 96.3%. The primary focus of this motor was to make sure our FEA simulation model predicted the measured losses and overall efficiency, this we moved on to the FEA simulation. The FEA simulations of the motor “as built” with misalignments had good correlation with the test results, so the next step was to use that model to optimize the design of the motor for a final build. This time we considered changes to the stator and rotor and also minor changes to the housing diameter. In the third budget period, we did the detailed design and construction of the final prototypes. The final prototypes had a slight increase in the stator diameter to fit in a standard Regal Beloit housing. We shortened the stator and use more layers of wire in the coils. We also increased the cone angle of the rotor and stator from the original 110 degrees to 130 degrees to get some additional efficiency and optimized the stator cross section. The predicted efficiency from the FEA simulations was 96.9%. When completed, the motors were tested. We were a little short of reaching our target efficiency goal of 96.8%. We were only able to get to 96.7% efficiency. While it may be possible with additional iterations in designs and future builds to gain that additional 0.1%, we believe that we are close to the best we can achieve from a practical viewpoint, and additional iterations would be more work than the potential gains would be worth. No other motor in this class can even reach the 96% that we started with.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

V1G Frequency Regulation: Algorithm Development, Validation & Analysis at Scale

Researchers at Argonne National Laboratory developed and validated a high-fidelity digital twin of a smart charging (V1G) ecosystem to model the participation of up to 1,000 unique electric vehicles (EVs) in the PJM frequency regulation market. Utilizing a discrete-event framework, the simulation models complex interactions, from dynamic grid signals (updated every 2 seconds) to individual EV charging dynamics. The simulation incorporates multiple EV models created from real-world lab test data. Researchers tested multiple control algorithms to balance the dual objectives of maximizing aggregator’s revenue and driver charging needs. Results demonstrate that aggregated EVs function as a controllable, highly effective grid resource, achieving high PJM Performance Scores (80–90%). Additionally, an optimized, market-aware bidding strategy was identified as key to profitability. The platform was shown to provide drivers with an average charging discount of nearly 50%. The algorithm was further validated in the lab using production EVs and charging stations to compare simulation results with real-world performance.

Manne, Nithin↗

Bond of steel-mortar interface interfered by stray current

Highlights: • The focus of this work is to present test results on the bond of steel-mortar interface undergoing stray current; • The bond strength is correlated to the electrochemical response of the steel-mortar interface; • The effects of duration of curing and starting point of stray current are also investigated; • This work also differentiates the effects of stray current on steel-mortar bond versus anodic polarization. The focus of this work is to present test results on the bond of steel-mortar interface undergoing stray current. The bond strength, derived by pull-out tests, is correlated to the electrochemical response of the steel rebar and the properties of the mortar bulk matrix. The effects of curing regimes (in terms of duration of curing) and starting point of stray current are also investigated. It is found that stray current exerts bond degradation of the steel-mortar interface in all investigated cases, irrespective of the presence or absence of a corrodent (Cl{sup −}) in the external medium. For the ease of operation in lab tests, the stray current is generally simulated by anodic polarization, although fundamentally, the stray current effect on the steel surface is composed of both anodic and cathodic polarizations. Hence this work also differentiates the effects of stray current on steel-mortar bond, versus the effects of anodic polarization.

36 MATERIALS SCIENCE↗

Development and Demonstration of a Reduced-Order PWR Power Dispatch Simulator

This report describes the development, modeling, and results of a reduced-order thermal power dispatch pressurized water reactor (RO-TPD-PWR) power plant simulator that incorporates coupled electrical and thermal power dispatch to an industrial process. The simulator is built on models that have been developed in previous work, including a Rancor Microworld model previously developed by INL and the University of Idaho [Ref] and reactor core and secondary system models that have been published previously [Ref]. The simulator also includes a scalable model of a high temperature electrolysis (HTE) system that has been developed at INL. A particular benefit of the Rancor Microworld model is that it is compatible with a human-system interface (HMI) that has already been developed by the Human System Simulation Laboratory (HSSL) at INL that can emulate the control room of a PWR for realistic human-in-the-loop studies with mock nuclear power plant operating procedures. The results of these human-in-the-loop tests will be compared with similar tests using a commercial full-scope generic PWR (GPWR) simulator that has been modified to include thermal power dispatch, referred to as the TPD-GPWR [ , ]. The simplicity of the RO-TPD-PWR helps to better understand and verify the results of the TPD-GPWR, which employs >1,000 variables and has much greater complexity. A second key purpose of the RO-TPD-PWR simulator is that its relative simplicity allows it scale between lab-size equipment (~100 kW) and full-scale nuclear power plants (~1 GW) by adjusting only a few parameters in the models, such as fluid masses and heat exchanger areas. The RO-TPD-PWR simulator will be used to guide the controls of lab tests, so that equipment in those tests, such as the Thermal Energy Distribution System (TEDS) and pilot-scale high temperature electrolysis (HTE) units at scales of 50-250 kW, may operate in a manner that is relevant to full-scale PWR operations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗