Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NASA Tech Briefs, January 2003

Topics covered include: Optoelectronic Tool Adds Scale Marks to Photographic Images; Compact Interconnection Networks Based on Quantum Dots; Laterally Coupled Quantum-Dot Distributed-Feedback Lasers; Bit-Serial Adder Based on Quantum Dots; Stabilized Fiber-Optic Distribution of Reference Frequency; Delay/Doppler-Mapping GPS-Reflection Remote-Sensing System; Ladar System Identifies Obstacles Partly Hidden by Grass; Survivable Failure Data Recorders for Spacecraft; Fiber-Optic Ammonia Sensors; Silicon Membrane Mirrors with Electrostatic Shape Actuators; Nanoscale Hot-Wire Probes for Boundary-Layer Flows; Theodolite with CCD Camera for Safe Measurement of Laser-Beam Pointing; Efficient Coupling of Lasers to Telescopes with Obscuration; Aligning Three Off-Axis Mirrors with Help of a DOE; Calibrating Laser Gas Measurements by Use of Natural CO2; Laser Ranging Simulation Program; Micro-Ball-Lens Optical Switch Driven by SMA Actuator; Evaluation of Charge Storage and Decay in Spacecraft Insulators; Alkaline Capacitors Based on Nitride Nanoparticles; Low-EC-Content Electrolytes for Low-Temperature Li-Ion Cells; Software for a GPS-Reflection Remote-Sensing System; Software for Building Models of 3D Objects via the Internet; "Virtual Cockpit Window" for a Windowless Aerospacecraft; CLARAty Functional-Layer Software; Java Library for Input and Output of Image Data and Metadata; Software for Estimating Costs of Testing Rocket Engines; Energy-Absorbing, Lightweight Wheels; Viscoelastic Vibration Dampers for Turbomachine Blades; Soft Landing of Spacecraft on Energy-Absorbing Self-Deployable Cushions; Pneumatically Actuated Miniature Peristaltic Vacuum Pumps; Miniature Gas-Turbine Power Generator; Pressure-Sensor Assembly Technique; Wafer-Level Membrane-Transfer Process for Fabricating MEMS; A Reactive-Ion Etch for Patterning Piezoelectric Thin Film; Wavelet-Based Real-Time Diagnosis of Complex Systems; Quantum Search in Hilbert Space; Analytic Method for Computing Instrument Pointing Jitter; and Semiselective Optoelectronic Sensors for Monitoring Microbes.

Source record↗

Ozone spectroscopy with a CO2 waveguide laser

Ozone spectral measurements were conducted with a waveguide CO2 laser, which was continuously tunable over a + or - 450-MHz region, about several lines in the P-branch of the band near the 9.5-micron wavelength region. A passively stabilized low-pressure CO2 laser was also used to provide reference CO2 frequencies. The frequencies of several ozone lines were determined in the nu-3 band, which are near CO2 laser line frequencies in the 9.5-micron wavelength region. The absolute measurement accuracy is estimated to be + or - 6 MHz, and the measurements indicate that the ozone line frequencies listed in currently available spectral compilations are 0.003-0.006 per cm too high. The size of this error is small by conventional IR standards, but extremely important when CO2 laser instruments are used to monitor stratospheric ozone, where line widths in this spectral region are typically 0.001/cm. Empirically determined absorption curves must be constructed in order to calibrate laser differential absorption instrument properly when low-altitude ozone measurements are conducted.

Menzies, R. T.↗

Heterodyne frequency measurements and frequency calibration standards for tunable diode lasers

New frequency calibration tables are required to keep abreast of the resolution attainable by currently available tunable lasers. One key to the generation of tables with requisite accuracy involves accurate heterodyne frequency measurements; another key consists of reliable fitting and analysis. Coordinated activity in NBS involves selection of suitable molecular calibration candidates, their frequency measurement and analysis, and dissemination of the results in the form of frequency calibration tables. Current status of these efforts is described.

Wells, J. S.↗

Laser/GRARR collocation experiment

Laser/range and range rate tracking collocation experiments with Explorer 29 to verify accuracy and laser calibration technique

Maresca, P. A.↗

Flight Test Techniques

These proceedings contain the twenty-five papers presented a the AGARD Flight Mechanics Panel Symposium on Flight Test Techniques, held in Lisbon, Portugal, 2-5 April 1984. Under main headings of Performance and Flying Qualities, Systems Testing, and Instrumentation and Facilities, papers were given on Lift-Drag; Parameter Identification; High-Angle Testing; Flight and Release of External Stores; Pilot Workload; Avionics, Navigation and Weapons Systems; H.U.D.; Real-Time Analysis and Test Control; Airborne Computation and Calibration; Laser Measurement of True Airspeed and Windshear; Clearance for Repaired Runway Operation.

Checkout↗

Transportability of a laser-induced fluorescence calibration for NO at high pressure

Obtaining quantitative measurements of NO concentration via laser-induced fluorescence (LIF) at high pressure requires application of a suitable calibration. While it is best to calibrate as close to the measurement condition as possible, this is not always feasible. To assess the transportability of a calibration factor at high pressure, we have calculated ratios between linear LIF signals corresponding to a constant NO concentration at different measurement and calibration conditions for high-pressure ethane flames. We find that pressure broadening limits the utility of calibrating at a pressure different from that of the measurement, although a calibration performed at a higher pressure is applicable over a wider range of pressures than one performed at atmospheric pressure. If one calibrates at the same pressure, it is best to calibrate at a temperature within 500 K of the measurement temperature. In general, the calculations indicate that a judicious choice of a calibration condition will guarantee a measured NO concentration within a factor of two of the actual NO concentration.

Reisel, John R.↗

Laser optogalvanic wavelength calibration with a commercial hollow cathode iron - neon discharge lamp

351 optogalvanic transitions have been observed in the 337 - 598 nm wavelength region using an iron - neon hollow cathode discharge lamp and a pulsed tunable dye laser. 223 of these have been identified as transitions associated with neon energy levels. These optogalvanic transitions have allowed, in conjunction with interference fringes recorded concomitantly with an etalon, the calibration of the dye laser wavelength with 0.3/cm accuracy.

Zhu, Xinming↗

Calibration of diode laser spectra using a confocal etalon

The dual-beam diode laser spectrometer described by Jennings (1980) is adapted to use a 50-cm confocal etalon for frequency calibration. The collimated radiation from the laser is split at a wedged ZnSe window, and the reference beam is then focused at the midpoint of the etalon length. After the etalon, the reference beam is recollimated and continues its regular path to the monochromator and detectors. An aperture is placed before the etalon in order to limit the entrance beam diameter to approximately 5 mm. Both ends of the etalon are furnished with two-axis adjustments. Initial alignment is achieved using an He-Ne laser, and final optimization involves adjustment of the cavity length as well as the etalon pitch and yaw. The 50-cm confocal etalon produces fringes separated by 150 MHz (0.005/cm). With the aid of a CO2 laser, it is found to have fringe widths (FWHM) of 2 MHz. The confocal etalon makes it possible to improve the accuracy of relative frequency measurements in diode laser spectra and to check the spectral purity and stability of the laser during the recording of spectra.

Jennings, D. E.↗

Spinning disk calibration method and apparatus for laser Doppler velocimeter

A method and apparatus for calibrating laser Doppler velocimeters having one or more intersecting beam pairs are described. These velocimeters measure fluid velocity by observing the light scattered by particles in the fluid stream. Moving fluid particulates are simulated by fine taut wires that are radially mounted on a disk that is rotated at a known velocity. The laser beam intersection locus is first aimed at the very center of the disk and then the disk is translated so that the locus is swept by the rotating wires. The radial distance traversed is precisely measured so that the velocity of the wires (pseudo particles) may be calculated.

Snyder, P. K.↗

Laser-Induced Incandescence Calibration via Gravimetric Sampling

Various beam imaging and/or sheet forming optics delivered light at 1064 nm from a pulsed Nd:YAG laser for use either as a beam of 3 mm radius or as a laser sheet. Imaging measurements were performed with a grated intensified array camera equipped with an ultraviolet f4.5 lens and a 40 mm extension tube. Point measurements were performed using an ultraviolet 250 mm focal length lens to collect and focus the laser induced incandescence (LII) signal into a 1 meter long quartz optical fiber which directed the LII signal to a 1/4 meter monochromator. An aperture preceding the lens restricted the signal collection region to 1 cm along the laser beam at the center of the gravimetric chimney. Signals from the PMT were processed by a boxcar integrator whereas the images were captured digitally using a frame-grabber with 16 MByte of on-board memory. Both 'point' and planar measurements were made with detector gates of 250 ns to minimize possible morphology bias in collection of the LII signal. Additionally, the imaging measurements were performed with broadband spectral collection of the LII signal to maximize the signal and again minimize any potential effects of morphology dependent heating and/or cooling rates. Digital delay generators controlled the firing of he laser, detector gates and data acquisition. Neutral density filters were used for both sets of measurements to maintain signal levels within linear dynamic ranges of the detectors, the range being determined prior to experiments.

VanderWal, R. L.↗

Data processing and calibration for tunable diode laser harmonic absorption spectrometers

Data processing and calibration methods are described for tunable diode laser absorption spectrometers which produce harmonic absorption spectra as raw data for measuring gas mixing ratios down to parts-per-trillion levels at a variety of pressures. The methods, which take advantage of modern computer speed, memory, and data storage capabilities, are applicable to the detection of weakly absorbing gases in quantitative industrial monitoring, in addition to aircraft and balloon atmospheric measurements for which they were designed. Algorithms for calibration and data analysis, including rejection of erroneous spectra, variation of effective integration time, spectral alignment prior to averaging, and plotting and archiving of results, have been tested on actual stratospheric laser spectra recorded by the Aircraft Laser Infrared Absorption Spectrometer (ALIAS) spectrometer in numerous flights of NASA's ER-2 aircraft.

May, Randy D.↗

Absolute Density Calibration Cell for Laser Induced Fluorescence Erosion Rate Measurements

Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser-induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. This work examines the suitability of the density cell as an absolute calibration source for LIF measurements, and the intrinsic error was evaluated.

Domonkos, Matthew T.↗

Electric current heating calibration of a laser holographic nondestructive test system

Holographic NDT was used to measure small surface displacements controlled by electric heating by detecting the difference of the interference fringe patterns as viewed through the hologram on a real time basis. A perforated aluminum test plate, with the holes used to position thin metal foils, was used in the experiment. One of the foils was connected to an electric power source and small displacements of the foil were caused and controlled by Ohmic heating. An He-Ne laser was used to perform the holography.

Liu, H.-K.↗

Partial Least Squares and Neural Networks for Quantitative Calibration of Laser-induced Breakdown Spectroscopy (LIBs) of Geologic Samples

The ChemCam instrument [1] on the Mars Science Laboratory (MSL) rover will be used to obtain the chemical composition of surface targets within 7 m of the rover using Laser Induced Breakdown Spectroscopy (LIBS). ChemCam analyzes atomic emission spectra (240-800 nm) from a plasma created by a pulsed Nd:KGW 1067 nm laser. The LIBS spectra can be used in a semiquantitative way to rapidly classify targets (e.g., basalt, andesite, carbonate, sulfate, etc.) and in a quantitative way to estimate their major and minor element chemical compositions. Quantitative chemical analysis from LIBS spectra is complicated by a number of factors, including chemical matrix effects [2]. Recent work has shown promising results using multivariate techniques such as partial least squares (PLS) regression and artificial neural networks (ANN) to predict elemental abundances in samples [e.g. 2-6]. To develop, refine, and evaluate analysis schemes for LIBS spectra of geologic materials, we collected spectra of a diverse set of well-characterized natural geologic samples and are comparing the predictive abilities of PLS, cascade correlation ANN (CC-ANN) and multilayer perceptron ANN (MLP-ANN) analysis procedures.

Anderson, R. B.↗

Spectral and Radiometric Calibration Using Tunable Lasers

A tunable laser system includes a tunable laser, an adjustable laser cavity for producing one or more modes of laser light emitted from the tunable laser, a first optical parametric oscillator positioned in a light path of the adjustable laser cavity, and a controller operable to simultaneously control parameters of at least the tunable laser, the first optical parametric oscillator, and the adjustable laser cavity to produce a range of wavelengths emitted from the tunable laser system. A method of operating a tunable laser system includes using a controller to simultaneously control parameters of a tunable laser, an adjustable laser cavity for producing one or more modes of laser light emitted from the tunable laser, and a first optical parametric oscillator positioned in a light path of the adjustable laser cavity, to produce a range of wavelengths emitted from the tunable laser system.

McCorkel, Joel↗

Intermode calibration of diode-laser spectra using tandem etalons

The paper deals with an approach which can improve the accuracy of etalon calibration of tunable diode-laser (TDL) spectra in the IR and extend absolute calibration among several isolated modes. Two etalons placed in the laser beam produce a combined fringe pattern that, with the aid of a monochromator mode selector, can be used to establish the number of fringes between any two spectral points separated by a large frequency interval. This technique has been applied to several similar cases for calibration of isolated modes or verification of the identity of lines of known frequency.

Jennings, D. E.↗

Retrievals of Thick Cloud Optical Depth from the Geoscience Laser Altimeter System (GLAS) by Calibration of Solar Background Signal

Laser beams emitted from the Geoscience Laser Altimeter System (GLAS), as well as other space-borne laser instruments, can only penetrate clouds to a limit of a few optical depths. As a result, only optical depths of thinner clouds (< about 3 for GLAS) are retrieved from the reflected lidar signal. This paper presents a comprehensive study of possible retrievals of optical depth of thick clouds using solar background light and treating GLAS as a solar radiometer. To do so we first calibrate the reflected solar radiation received by the photon-counting detectors of GLAS' 532 nm channel, which is the primary channel for atmospheric products. The solar background radiation is regarded as a noise to be subtracted in the retrieval process of the lidar products. However, once calibrated, it becomes a signal that can be used in studying the properties of optically thick clouds. In this paper, three calibration methods are presented: (I) calibration with coincident airborne and GLAS observations; (2) calibration with coincident Geostationary Operational Environmental Satellite (GOES) and GLAS observations of deep convective clouds; (3) calibration from the first principles using optical depth of thin water clouds over ocean retrieved by GLAS active remote sensing. Results from the three methods agree well with each other. Cloud optical depth (COD) is retrieved from the calibrated solar background signal using a one-channel retrieval. Comparison with COD retrieved from GOES during GLAS overpasses shows that the average difference between the two retrievals is 24%. As an example, the COD values retrieved from GLAS solar background are illustrated for a marine stratocumulus cloud field that is too thick to be penetrated by the GLAS laser. Based on this study, optical depths for thick clouds will be provided as a supplementary product to the existing operational GLAS cloud products in future GLAS data releases.

Yang, Yuekui↗