Design and Performance Evaluation of a UWB Communication and Tracking System for Mini-AERCam

NASA Johnson Space Center (JSC) is developing a low-volume, low-mass, robotic free-flying camera known as Mini-AERCam (Autonomous Extra-vehicular Robotic Camera) to assist the International Space Station (ISS) operations. Mini-AERCam is designed to provide astronauts and ground control real-time video for camera views of ISS. The system will assist ISS crewmembers and ground personnel to monitor ongoing operations and perform visual inspections of exterior ISS components without requiring extravehicular activity (EAV). Mini-AERCam consists of a great number of subsystems. Many institutions and companies have been involved in the R&D for this project. A Mini-AERCam ground control system has been studied at Texas A&M University [3]. The path planning and control algorithms that direct the motions of Mini-AERCam have been developed through the joint effort of Carnegie Mellon University and the Texas Robotics and Automation Center [5]. NASA JSC has designed a layered control architecture that integrates all functions of Mini-AERCam [8]. The research described in this report is part of a larger effort focused on the communication and tracking subsystem that is designed to perform three major tasks: 1. To transmit commands from ISS to Mini-AERCam for control of robotic camera motions (downlink); 2. To transmit real-time video from Mini-AERCam to ISS for inspections (uplink); 3. To track the position of Mini-AERCam for precise motion control. The ISS propagation environment is unique due to the nature of the ISS structure and multiple RF interference sources [9]. The ISS is composed of various truss segments, solar panels, thermal radiator panels, and modules for laboratories and crew accommodations. A tracking system supplemental to GPS is desirable both to improve accuracy and to eliminate the structural blockage due to the close proximity of the ISS which could at times limit the number of GPS satellites accessible to the Mini-AERCam. Ideally, the tracking system will be a passive component of the communication system which will need to operate in a time-varying multipath environment created as the robot camera moves over the ISS structure. In addition, due to many interference sources located on the ISS, SSO, LEO satellites and ground-based transmitters, selecting a frequency for the ISS and Mini-AERCam link which will coexist with all interferers poses a major design challenge. To meet all of these challenges, ultrawideband (UWB) radio technology is being studied for use in the Mini-AERCam communication and tracking subsystem. The research described in this report is focused on design and evaluation of passive tracking system algorithms based on UWB radio transmissions from mini-AERCam.

Barton, Richard J.↗

InGaAs Detectors for Miniature Infrared Instruments

In the past year, there has been substantial impetus for NASA to consider missions that are of relatively low cost as a trade off for a higher new mission launch rate. To maintain low mission cost, these missions will be of short duration and will use smaller launch vehicles (e.g. Pegasus). Consequently, very low volume, very low mass instrument (a.k.a. miniature instrument) payloads will be required. Furthermore, it is anticipated that the number of instruments flown on a particular mission will also be highly constrained; consequently increased instrument capability will also be desired. In the case of infrared instruments, focal planes typically require cooling to ensure high performance of the detectors, especially in the case of spectrometers where high D* is necessary. In this paper, we discuss the InGaAs detector technology and its potential.

Krabach, T. N.↗

Passive, Collapsible Contingency Urinal for Human Space Flight

Fluid transport systems for spacecraft face acute challenges because of the persistently unfamiliar and unforgiving low-gravity environment. IRPI, LLC, has developed a contingency wastewater collection and processing device that provides passive liquid collation, containment, bubble separation, and droplet coalescence functions. The lightweight, low-volume, low-cost, and potentially disposable device may be used for subsequent sampling, metering, storage, disposal, and/or reuse. The approach includes a fractal wetting design that incorporates smart capillary fluidics. This work could have a broad impact on capillary-based fluid management on spacecraft and on Earth.

Jenson, Ryan↗

Low-Dead-Volume Inlet for Vacuum Chamber

Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead -volume. As a result, a high -vacuum gas inlet was developed with low dead -volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.

Naylor, Guy↗

Stresses, strains, and surface pressures in the lung caused by its weight.

In an effort to understand how the lung is deformed by its own weight, we have analyzed the distribution of regional expansion, stresses, and surface pressures in a theoretical elastic lung-shaped model using the technique of finite elements. In the upright position, the parenchyma was most expanded at the apex and least at the base. Stresses in both the vertical and lateral directions were maximal at the apex. As the lung was inflated from very low volumes to total lung capacity, parenchymal expansion and stress at the apex first decreased, then increased. This behavior can be explained by the increasing rigidity of the expanded lung which enabled it to resist distortion by its own weight. At functional residual capacity, the stress at the apex was near its minimum. The differences in intrapleural pressure down the lung were volume dependent, increasing at very low volumes. In the inverted lung, the regional differences in stress, strain, and surface pressures were less marked because of the shape of the chest.

West, J. B.↗

Low-Dead-Volume Inlet for Vacuum Chamber

Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead-volume. As a result, a high-vacuum gas inlet was developed with low dead-volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.

Naylor, Guy↗

Parallel Plate Capacitor Aluminum KIDs for Future Far-Infrared Space-Based Observatories

Future space-based far-infrared astrophysical observatories will require exquisitely sensitive detectors consistent with the low optical backgrounds. The PRobe far-Infrared Mission for Astrophysics (PRIMA) will deploy arrays of thousands of superconducting kinetic inductance detectors (KIDs) sensitive to radiation between 25 and 265 μm. Here, we present laboratory characterization of prototype, 25 – 80 μm wavelength, low-volume, aluminum KIDs designed for the low-background environment expected with PRIMA. A compact parallel plate capacitor is used to minimize the detector footprint and suppress TLS noise. A novel resonant absorber is designed to enhance response in the band of interest. We present noise and optical efficiency measurements of these detectors taken with a low background cryostat and a cryogenic blackbody. A microlens-hybridized KID array is found to be photon noise limited down to about 50 aW with a limiting detector NEP of about 6.5×10 −19 W/Hz 1/2 . A fit to an NEP model shows that our optical system is well characterized and understood down to 50 aW. We discuss future plans for low-volume aluminum KID array development as well as the testbeds used for these measurements.

Far-Infrared↗

Evolution of Local Microstructures: Spatial Instabilities in Coarsening Clusters

Diffusion-limited capillarity-driven coarsening of precipitates is an important and intensively studied phenomenon. The classic coarsening theory developed by Lifshitz and Syozov and Wagner (LSW theory) is limited to infinitesimally small volume fractions, V(sub nu), therefore neglects all direct interparticle interactions. This work uses modeling and holographic imaging to compare coarsening rates in "high" volume fraction versus low volume fraction microstructures by observing mixed-dimensional droplets (spherical caps on a surface coarsening by two-dimensional diffusion) during ground-based investigations. The method involves filling a cell with selected homogeneous parent phase, and cooling below the consolute temperature to the isopycnic temperature in the two-phase region of a monotectic system. A microgravity holographic experiment is required for three-dimensional observations to minimize sedimentation during long-term coarsening. Determination of sizes and positions of the many droplets in the holographic images requires automation. We have developed software for automated data analysis, and demonstrated good agreement between regenerated maps and scaled photographs of the original holograms for mixed dimensional coarsening. The results of these experiments were presented in a formal microgravity Science Concept Review (SCR) on December 18, 2000.

Source record↗

Improved Ambient Pressure Pyroelectric Ion Source

The detection of volatile vapors of unknown species in a complex field environment is required in many different applications. Mass spectroscopic techniques require subsystems including an ionization unit and sample transport mechanism. All of these subsystems must have low mass, small volume, low power, and be rugged. A volatile molecular detector, an ambient pressure pyroelectric ion source (APPIS) that met these requirements, was recently reported by Caltech researchers to be used in in situ environments.

Beegle, Luther W.↗

Enabling Microliquid Chromatography by Microbead Packing of Microchannels

The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

Balvin, Manuel↗

Enabling Microliquid Chromatography by Microbead Packing of Microchannels

The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

Balvin, Manuel↗

Dynamics of Single Chains of Suspended Ferrofluid Particles

We present an experimental study of the dynamics of isolated chains made of super-paramagnetic particles under the influence of a magnetic field. The motivation of this work is to understand if the chain fluctuations exist and, if it does, how does the fluctuation affect chain aggregation. We find that single chains strongly fluctuate and that the characteristic frequency of their fluctuations is inversely proportional to the magnetic field strength. The higher the field the lower the characteristic frequency of the chain fluctuations. In the high magnetic field limit, chains behave like rigid rods without any internal motions. In this work, we used ferrofluid particles suspended in water. These particles do not have any intrinsic magnetization. Once a magnetic field is applied, a dipole moment is induced in each particle, proportional to the magnetic field. A dipolar magnetic interaction then occurs between particles. If dipole-dipole magnetic energy is higher than the thermal energy, the result is a structure change inside the dipolar fluid. The ratio of these two energies is expressed by a coupling constant lambda as: lambda = (pi(a(exp 3))(chi(exp 2))(mu(sub 0))(H(sub 0))(exp 2))/18kT Where a is the particle radius, mu(sub 0) is the vacuum magnetic permeability, H(sub 0) the applied magnetic field, k the Boltzmann constant and T the absolute temperature. If lambda > 1, magnetic particles form chains along the field direction. The lateral coalescence of several chains may form bigger aggregates especially if the particle volume fraction is high. While many studies and applications deal with the rheological properties and the structural changes of these dipolar fluids, this work focuses on the understanding of the chain dynamics. In order to probe the chain dynamics, we used dynamic light scattering (DLS) in self-beating mode as our experimental technique. The experimental geometry is such that the scattering plane is perpendicular to the magnetic field. Therefore, only motions in this plane are probed. A very dilute sample of a ferrofluid emulsion with a particle volume fraction of 10(exp -5) is used in this experiment. We chose such a low volume fraction to avoid multiple light scattering as well as lateral chain-chain aggregation. DLS measures the dynamic structure factor S(q,t) of the sample (q is the scattering wave vector, t is the time). In the absence of the magnetic field, identical particles of ferrofluid droplets are randomly distributed and S(q,t) reduces to exp(-q(exp 2)2D(sub 0)t). D(sub 0)=(kT/(6(pi)(eta)(a)) is the diffusion coefficient of Brownian particles (where Xi = (6(pi)(eta)(a)) is the Stokes frictional coefficient of a spherical particle in a fluid of viscosity eta). If interactions or polydispersity can not be ignored, an effective diffusion coefficient is introduced. Formally, D(sub eff) is defined as: D(sub eff) = - q(exp -2) partial derivative of (ln(S(q,t)) with respect to time, as t goes to 0. D(sub eff) reduces to D(sub 0) if no interactions and only a few particles size are present. Therefore, we can use DLS to measure particle size. The particle radius was found to be a=0.23 mu m with 7% of polydispersity. In this case, if we vary the scattering angle theta (and so q) we do not have any change in the measured diffusion coefficient: it is q-independent. When a magnetic field is applied, particles aggregate into chains if lambda > 1. We first studied the kinetics of the chain formation when lambda = 406. At a fixed scattering angle, we measured diffusion coefficient D(sub eff) as a function of time. Experimentally, we find that D(sub eff) decreases monotonously with time. Physically, this means that chains are becoming longer and longer. Since we are only sensitive to motions in the scattering plane and since chains have their main axis perpendicular to this plane, the measured diffusion coefficient is the trans-verse diffusion coefficient. We can relate D(sub eff) to the mean number of particles per chain N(t) at a given time and to the diffusion coefficient of an isolated particle D(sub 0) as D(sub eff)=f(N(t))D(sub 0). Since f(N) is known from other recent work, N can be expressed as a function of the time. We found a square root dependency: N(t) proportional to the square root of t. As expected for very low volume fraction, this behavior is characteristic of a diffusion-limited aggregation as suggested by several authors and by our previous work. In this study, we focus on the dependence of the effective diffusion coefficient on the scattering angle and the magnetic field strength. After the magnetic field is applied (lambda = 406) for a long time, typically 6 hours, kinetics of chain formation becomes very slow. Chain size does not vary much over the next hour period. Thus, we can perform different interesting experiments. First, at a fixed magnetic field, we measure the effective diffusion coefficient as a function of the scattering angle (from 5 to 130 deg). Our results show that the measured diffusion coefficient increases linearly with the scattering angle: D(sub eff) proportional to q. If we do the same experiment for different lambda values, D(sub eff) depends on lambda as D(sub eff) proportional to lambda(exp -1/2). We also find for different lambda values that the same asymptotic D(sub eff) value is obtained when q approaches zero. The angle dependency of D(sub eff) suggests that an additional motion exists besides chain drifting. Chain size is constant during experiment, which was verified by measuring the same diffusion coefficient at the beginning and at the end of the angle switching. If chains are rigid, D(sub eff) is independent of q. Therefore, we found that D(sub eff) not only measures the motion of the entire chain but also its internal fluctuations. These internal motions are the fluctuations of the particles in the chain. To understand the q dependency of D(sub eff), let us look at the probing length used. In our study, the characteristic length scale probed is l=2pi/q which is in the range of 0.9<l/a<20. When l is much larger than the particle radius (l/a going to infinity) we are mainly sensitive to the center of mass diffusion of the chain. D(sub eff) is then the diffusion of the entire chain and depends only on N but not on q and lambda. The value D(sub eff) allows us to obtain the number of particles per chain N. In the opposite limit (i.e. l/a < 1), we are sensitive to motions on the size of individual particles. The main contributions to the measured diffusion coefficient come from internal motions of the chains (i.e. particles' fluctuations inside the chain). We investigated also the effect of the chain size on D(sub eff). For the same value of the magnetic interaction lambda and different chain sizes, we found that the slope of D(sub eff) versus q decreases when N increases as a power law D(sub eff) proportional to N(exp -0.7). This is an important behavior because this means that the longer the chain the slower its internal fluctuations besides the whole chain motion.

Cutillas, S.↗

Additional experiments on flowability improvements of aviation fuels at low temperatures, volume 2

An investigation was performed to study flow improver additives and scale-model fuel heating systems for use with aviation hydrocarbon fuel at low temperatures. Test were performed in a facility that simulated the heat transfer and temperature profiles anticipated in wing fuel tanks during flight of long-range commercial aircraft. The results are presented of experiments conducted in a test tank simulating a section of an outer wing integral fuel tank approximately full-scale in height, chilled through heat exchange panels bonded to the upper and lower horizontal surfaces. A separate system heated lubricating oil externally by a controllable electric heater, to transfer heat to fuel pumped from the test tank through an oil-to-fuel heat exchanger, and to recirculate the heated fuel back to the test tank.

Stockemer, F. J.↗

Oxygen Generator System Mars In-Situ Propellant Production Precursor Flight

The 2001 Lander to Mars will carry the first ever ISRU payload to Mars. This payload, the Mars In-situ Propellant production Precursor (MIP), will demonstrate a variety of technologies that will be required for future ISRU Mars indigenous material processing plant designs. One of those technologies is that of extracting oxygen from the predominantly carbon dioxide atmosphere of Mars, a prerequisite for future sample return and human missions to Mars. The Oxygen Generator Subsystem (OGS) portion of the MIP will demonstrate this and is the focus of this paper. The primary objective of the OGS is to demonstrate the production of oxygen from Mars atmospheric gases. Secondary objectives are to measure the performance and reliability of oxygen generation hardware in actual mission environments over an extended time. Major constraints on the OGS design came from several sources. The Lander provides power to the system from solar power that is harnessed by photovoltaic arrays. This limited OGS to daytime only operations (six to eight hours) and a maximum power of 15W. The reliance on solar power necessitated thermal cycling of the OGS between Mars ambient and OGS operating temperatures. The Lander also limited the total mass of the MIP payload to 7.5 kg with a correspondingly small volume, and the OGS was one of six experiments in the MIP. Mass and volume were to be minimized. Another constraint was cost. Mission funding, as always, was tight. Cost was to be minimized. In short the OGS design had to be low power (<15 Watts), low mass (1 kg), low volume, low cost, and be capable of cyclical operations for an extended stay on Mars. After extensive research, a zirconia based solid oxide electrolyzer design was selected.

Sridhar, K. R.↗

Oxygen Generator System Mars In-Situ Propellant Production Precursor Flight

The 2001 Lander to Mars will carry the first ever In situ Resource Utilization (ISRU) payload to Mars. This payload, the Mars In-situ Propellant production Precursor (MIP), will demonstrate a variety of technologies that will be required for future ISRU Mars indigenous material processing plant designs. One of those technologies is that of extracting oxygen from the predominantly carbon dioxide atmosphere of Mars, a prerequisite for future sample return and human missions to Mars. The Oxygen Generator Subsystem (OGS) portion of the MIP will demonstrate this and is the focus of this paper. The primary objective of the OGS is to demonstrate the production of oxygen from Mars atmospheric gases. Secondary objectives are to measure the performance and reliability of oxygen generation hardware in actual mission environments over an extended time. Major constraints on the OGS design came from several sources. The Lander provides power to the system from solar power that is harnessed by photovoltaic arrays. This limited OGS to daytime only operations (six to eight hours) and a maximum power of 15W. The reliance on solar power necessitated thermal cycling of the OGS between Mars ambient and OGS operating temperatures. The Lander also limited the total mass of the MIP payload to 7.5 kg with a correspondingly small volume, and the OGS was one of six experiments in the MIP Mass and volume were to be minimized. Another constraint was cost. Mission funding, as always, was tight. Cost was to be minimized. In short the OGS design had to be low power (<15 Watts), low mass (1 kg), low volume, low cost, and be capable of cyclical operations for an extended stay on Mars. After extensive research, a zirconia based solid oxide electrolyzer design was selected.

Sridhar, K. R.↗

Energy Efficient Engine Program Advanced Turbofan Nacelle Definition Study

Advanced, low drag, nacelle configurations were defined for some of the more promising propulsion systems identified in the earlier Benefit/Cost Study, to assess the benefits associated with these advanced technology nacelles and formulate programs for developing these nacelles and low volume thrust reversers/spoilers to a state of technology readiness in the early 1990's. The study results established the design feasibility of advanced technology, slim line nacelles applicable to advanced technology, high bypass ratio turbofan engines. Design feasibility was also established for two low volume thrust reverse/spoiler concepts that meet or exceed the required effectiveness for these engines. These nacelle and thrust reverse/spoiler designs were shown to be applicable in engines with takeoff thrust sizes ranging from 24,000 to 60,000 pounds. The reduced weight, drag, and cost of the advanced technology nacelle installations relative to current technology nacelles offer a mission fuel burn savings ranging from 3.0 to 4.5 percent and direct operating cost plus interest improvements from 1.6 to 2.2 percent.

Howe, David C.↗

Development of a regenerable metal oxide CO removal system

A regenerable metal oxide carbon dioxide (CO2) removal system was developed to replace the current means of a nonreusable chemical, lithium hydroxide, for removing the metabolic CO2 of an astronaut in a space suit. Testing indicates that a viable low-volume metal oxide concept can be used in the portable life support system for CO2 removal during Space Station extravehicular activity (EVA). A canister of nearly the same volume as that used for the Space Shuttle, containing 0.10 cu ft of silver-oxide-based pellets, was tested; test data analysis indicates that 0.18 cu ft of the metal oxide will result in an 8-hour EVA capability. The testing suggests that the metal oxide technology offers a low-volume approach for a reusable CO2 removal concept applicable for at least 40 EVA missions. The development and testing of the breadboard regeneration package is also described.

Cusick, Robert J.↗