Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

Quadrupole and multi-collector ICP-MS analysis of 226 Ra in brain from a radium dial painter

We report two ICP-MS methods were developed to measure the radiotoxic isotope 226 Ra in brain tissues from a radium dial painter worker. The first method was a direct analysis of acid digested samples using quadrupole ICP-MS. The instrumental LOD of 226 Ra was 0.1 ng kg -1 . Polyatomic interferences at m/z 226 were investigated and Pb was identified from a polyatomic interferent in an in-house sample prepared from bovine brain, with a 226/208 formation ratio of 4 × 10 -8 . The quadrupole ICP-MS method was also used to measure levels of beryllium, strontium, and uranium. A second method was developed that included cation-exchange chromatography to separate 226 Ra followed by analysis with sector field MC-ICP-MS. The instrumental LOD for the cation exchange method with MC-ICP-MS detection was 0.5 pg kg -1 (19 mBq kg -1 ). The measured concentrations of 226 Ra in different brain regions ranged from 0.09–0.72 ng kg -1 (3.3–27 Bq kg -1 ) and radium was non-uniformly distributed in the brain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Certification of Uranium Isotope Amount Ratios in a Suite of Uranium Ore Concentrate Certified Reference Materials

Here, in this study, data from thirteen laboratories from around the world are presented for a successful certification of uranium isotope ratios in uranium ore concentrate (UOC) certified reference materials from the National Research Council Canada. Different mass spectrometric measurement principles (including SF-ICP-MS, quadruple ICP-MS, TIMS, MC-ICP-MS, SIMS and AMS) and measurement procedures were employed. In general, data from all sources exhibit good consistency with TIMS and MC-ICP-MS showing superior performance. The three candidate UOC CRMs (UCLO-1, UCHI-1 and UPER-1) have natural uranium isotope ratios with certified values of 0.5304(7) x 10 -4 , 0.5475(2) x 10 -4 and 0.5361(4) x 10 -4 for n( 234 U)/n( 238 U) and 0.007 2563(13), 0.007 2563(10) and 0.007 2542(11) for n( 235 U)/n( 238 U), respectively, with expanded uncertainty (k = 2) applicable to the last digit of the value given in the parentheses. Information values for n( 236 U)/n( 238 U) in these three CRMs, measured by AMS, are also provided: 10 x 10 -12 , 200 x 10 -12 and 22 x 10 -12 . The uncertainties of the proposed certified values of uranium isotope ratios in UOC CRMs are superior to available reference materials, and the values of n( 234 U)/n( 238 U) and n( 236 U)/n( 238 U) show significant variation among the three CRMs.

58 GEOSCIENCES↗

Measurements of effective actinides neutron capture cross sections in a cadmium-filtered epithermal neutron spectrum

In this work, a total of 20 actinide samples were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL): 233 U (1), 235 U (1), 236 U (1), 238 U (1), 237 Np (2), 239 Pu (1), 240 Pu (1), 242 Pu (2), 244 Pu (2), 241 Am (2), 243 Am (2), 244 Cm (2), and 248 Cm (2). The samples were loaded in a basket containing a 1.1-mm thick cadmium filter. The presence of the filter drastically changes the neutron spectrum in the samples and accentuates the reaction rates in the resonance region. Isotopic ratios were determined using Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) that allowed inferring effective capture cross sections. Detailed best-estimate MCNP models of the experiment using ENDF/B-VII.0 nuclear data were developed to calculate the effective neutron cross sections and, subsequently, compare them with the cross sections inferred from experimental results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plutonium mobilization from contaminated estuarine sediments, Esk Estuary (UK)

Since 1952, liquid radioactive effluent containing 238-242 Pu, 241 Am, 237 Np, 137 Cs, and 99 Tc has been released with authorization from the Sellafield nuclear complex (UK) into the Irish Sea. This represents the largest source of plutonium (Pu) discharged in all western Europe, with 276 kg having been released. In the Eastern Irish Sea, the majority of the transuranic activity has settled into an area of sediments (Mudpatch) located off the Cumbrian coast. Radionuclides from the Mudpatch have been re-dispersed via particulate transport in fine-grained estuarine and intertidal sediments to the North-East Irish Sea, including the intertidal saltmarsh located at the mouth of the Esk Estuary. Saltmarshes are highly dynamic systems which are vulnerable to external agents (sea level change, erosion, sediment supply, and freshwater inputs), and their stability remains uncertain under current sea level rise projections and possible increases in storm activity. In this work, we examined factors affecting Pu mobility in contaminated sediments collected from the Esk Estuary by conducting leaching experiments under both anoxic and oxic conditions. Here, leaching experiments were conducted over a 9-month period and were periodically sampled to determine solution phase Pu via multicollector-inductively coupled plasma-mass spectrometry (MC-ICP-MS), and to measure redox indicators (Eh, pH and extractable Fe(II)). Microbial community composition was also characterized in the sediments, and at the beginning and end of the anoxic/oxic experiments. Results show that: 1) Pu leaching is about three times greater in solutions leached under anoxic conditions compared to oxic conditions, 2) the sediment slurry microbial communities shift as conditions change from anoxic to oxic, 3) Pu leaching is enhanced in the shallow sediments (0–10 cm depth), and 4) the magnitude of Pu leached from sediments is not correlated with total Pu, indicating that the biogeochemistry of sediment-associated Pu is spatially heterogeneous. These findings provide constraints on the stability of redox sensitive Pu in biogeochemically dynamic/transient environments on a timescale of months and suggests that anoxic conditions can enhance Pu mobility in estuarine systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Coupled feldspar dissolution and secondary mineral precipitation in batch systems: 6. Labradorite dissolution, calcite growth, and clay precipitation at 60 °C and pH 8.2–8.4

Here, we conducted experiments on concurrent labradorite dissolution, calcite precipitation, and clay precipitation in batch reactor systems and tracked reaction processes using multiple isotope tracers. Labradorite was chosen for its role as a major and reactive component in basalt; the experiments thus directly impact our understanding of CO 2 storage in basalt aquifers and enhanced rock weathering. We doped initial solutions with 29 Si, 43 Ca, and Ca 13 CO 3 (s). Experiments were conducted at 60 °C and pH ~ 8.3 for up to 840 h, with isotope ratios in the experimental aqueous solutions measured using MC-ICP-MS. Unidirectional rates of labradorite dissolution near equilibrium were approximately two orders of magnitude slower than far-from-equilibrium rates reported in the literature. Calcite growth occurred near equilibrium and the rates were limited by the labradorite dissolution rates. In the steady state phase, the interplay of these three heterogeneous reactions—labradorite dissolution, calcite growth, and clay precipitation—results in a coupled system that approaches a near-equilibrium state. The system does not reach true equilibrium because labradorite continues to dissolve, albeit at a much slower rate near equilibrium. The overall reaction can be approximated as, Na 0.4 Ca 0.6 Al 1.6 Si 2.4 O 8 + 0.6HCO 3 - + 1·.7H 2 O + 0.4H + → 0.4Na + + 0.6CaCO 3(s) + 0.5Al 2 Si 2 O 5 (OH) 4(s) + 0.6Al(OH) 4 - + 1.4SiO 2 o (aq). The experimental results show that using short-term far-from-equilibrium rate constants would lead to an overestimation of feldspar weathering rates at the Earth’s surface (e.g., basalt weathering and enhanced rock weathering) and CO 2 mineralization in basalt aquifers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RAPID UNSEPARATED RARE EARTH ELEMENT ANALYSES BY ISOTOPE DILUTION MULTICOLLECTOR INDUCTIVELY COUPLED MASS SPECTROMETRY (ID-MC-ICP-MS)

We present a method for analyzing rare earth elements (REEs) by isotope dilution without separation of individual elements. Utilizing a Nu Plasma 2 multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with an Aridus II desolvation nebulizer, sample introduction tuning parameters (torch position, gas flows) were investigated and used to minimize oxide formation (e.g., NdO/Nd <0.05%) and remove the need to analyze the REEs as separated “cuts.” Ratios for spike/sample isotopes in mixed synthetic standards containing varying amounts of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb were measured accurately within 1% of IUPAC values. La and Lu in the standards were more than 2% off from expected values due to more demanding interference corrections. A USGS BCR-2 rock standard was also processed with flux fusion, iron coprecipitation and a single column pass bulk separation followed by analysis. The concentrations for Ce, Nd, Sm, Eu, Dy, Er, and Yb fell within 2% of consensus values. A United States Geological Survey (USGS) BIR-1A rock standard was also processed in triplicate by hydrofluoric and nitric acid digestion, yielding rare earth concentrations within 3% of consensus values with 0.3% relative standard deviation (n=3). This demonstrates the ability to produce high quality REE patterns of comparable quality to traditional methods involving labor and time intensive REE separation, with sample preparation and analytical times that are comparable to analyses against isotope dilution by single-collector ICP-MS.

Shen, Steve D.↗

Synthesis and characterization of isotopically barcoded nickel, molybdenum, and tungsten taggants for intentional nuclear forensics

Intentional nuclear forensics is a concept wherein the deliberate addition of benign and persistent material signatures to nuclear material can be used to reduce the time between the discovery of material outside of regulatory control and determination of its original provenance. One concept within intentional nuclear forensics involves the use of perturbed stable isotopes to generate unique isotope ratio “barcodes” to encode information (e.g., production batch, location, etc.) and track material throughout the nuclear fuel cycle. Synthesis of taggant species of nickel (Ni), molybdenum (Mo), and tungsten (W) was undertaken via a double-spike mechanism, wherein two highly enriched isotopes of interest per elemental taggant were mixed to form an enriched “double-spike” which was subsequently isotopically diluted with bulk material having a natural isotopic composition. Two taggant species perturbing isotopic ratios, alpha (α) and beta (β), for each of Ni, Mo, and W were synthesized. Independent measurements of double spikes and alpha and beta taggant species agreed within uncertainty and are clearly resolvable from natural compositions. High-precision analyses were independently performed by MC-ICP-MS at two U.S. National Laboratories, with consensus values and uncertainties calculated for all samples. Observed isotopic perturbations in the final taggant species measured on the order of hundreds to thousands of permille (‰) with respect to natural for isotope ratios of interest (e.g., 60 Ni/ 58 Ni, 100 Mo/ 98 Mo, 186 W/ 183 W). Discrepancies between modeled and measured isotopic compositions were observed and are largely attributed to imprecise vendor assay values for starting materials. Using measured starting material compositions as inputs for the mixing model improved the level of agreement between predicted and measured α and β taggant isotope ratios. Overall, characterization of all taggant species demonstrates that this “barcode” concept could have viability for use in nuclear forensics. Finally, it is expected that for any two-isotope mixing array dozens of isotopic barcodes could be encoded into a material system and subsequently resolved utilizing modern mass spectrometric methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Measurement of Mass-Independent Perturbations of Cadmium in Nuclear Debris Samples

The isotopic composition of cadmium in nuclear debris was measured by multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). Mass-independent perturbations due to fission product decay on the isotopes of Cd were observed. Relative fission yields for masses 111, 112, 114 and 116 were determined in each sample of nuclear debris and compared with reported values found in irradiated plutonium and uranium fuels. Mass spectrometry measurements of the valley fission product endpoints are extremely challenging due to the low cumulative fission yields and small amounts of each isotope that are produced. To overcome these challenges, a new purification method for Cd was developed and validated by examination of a number of geological reference materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data review processes in the analytical laboratory

These documents contain information on the Analytical laboratory data review processes for the following analytical techniques: - alpha spectrometry - light elements analyses - gamma spectrometry - gas proportional flow counting - HR-ICP-MS - Q-ICP-MS - MC-ICP-MS - ICP OES - liquid scintillation counting

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

US-DOE and Republic of South Africa Uranium Benchmarking: Results From Los Alamos National Laboratory (Study Report)

This report details work performed at Los Alamos National Laboratory (LANL) in support of an interlaboratory uranium (U) benchmarking collaboration between LANL, Lawrence Livermore National Laboratory (LLNL), and South African Nuclear Energy Corporation (Necsa). The goal of this interlaboratory benchmarking exercise is to compare analytical methods and data obtained on uranium reference materials CUP-2 and New Brunswick Laboratory (NBL) certified reference material (CRM) 124-2. The LANL commitments for this project include performing microwave digestion of fresh CUP-2 and CRM 124-2 powders, measuring the U isotope composition of CUP-2 and CRM 124-2 by both single-collector and multi-collector inductively coupled plasma mass spectrometry (SC-ICP-MS and MC-ICP-MS, respectively), and determining trace-element abundances in CUP-2 and CRM 124-2 by inductively coupled plasma mass spectrometry (ICP-MS). This report details the methods employed by LANL in support of these objectives and presents the data obtained during this collaborative exercise.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

Characterizing the Uncertainty of Measurement of Traceable Isotope Ratios with Bayesian Statistical Techniques

Analytical techniques such as multicollector—inductively coupled plasma—mass spectrometry (MC-ICP-MS) are routinely employed at SRNL, other National Laboratories, and in academia to determine the precise isotopic composition of diverse natural and anthropogenic samples (e.g., rocks and nuclear materials). Quantifying and reporting uncertainty in such analyses, while regularly performed, have a rigorous statistical foundation. The Guide to the Expression of Uncertainty in Measurement 4 (GUM) outlines conventional techniques used to assess such uncertainty. As the accessibility and speed of statistical computing increase, there is a need to modernize conventional techniques. For example, Supplement 1 to the 3rd to the GUM suggests the use of approximation methods as an updated approach to the GUM.

McLarty, Ellis C.↗

C136A and C138A Report of Analysis

In this work the isotopic ratios and weight percentages of 238 Pu, 239 Pu, 240 Pu, 241 Pu and 242 Pu were determined using Isotope Dilution Mass Spectrometry. Two samples of C136A and C138A were sent to the Analytical Research laboratories by the National Nuclear Security Administration Nuclear Reference Material Program. The four samples were dissolved in concentrated hydrochloric acid. From the parent solutions, eight aliquots were taken, diluted, spiked with 244 Pu and submitted to separations. After the samples were separated, they were analyzed using Multicollector Inductively Coupled Plasma Mass Spectrometry. Along with the samples, two C126A Quality Control Samples were analyzed each day. Mass bias standards were also analyzed at the beginning, during and at the end of the analysis. GUM Workbench Pro software Version 2.4.1.406 was used to calculate the isotopic ratios relative to 239 Pu, and total Pu mass and the correlated expanded uncertainties.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗