Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEDLI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Towards the Prediction of the Mars 2020 Heatshield Material Response

Introduction: NASA’s next mission to Mars, the Mars 2020, will use the same heatshield of the Mars Science Laboratory (MSL) for thermal protection during entry, descent and landing. The heatshield is a tiled system made of Phenolic Impregnated Carbon Ablators (PICA) blocks [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers excellent performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of atmospheric entry and material response. MEDLI recorded, among others, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to compare the thermal response of the MSL heatshield to the MISP flight data. In preparation to Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against MEDLI flight data.

heatshield↗

Laboratory-Based Thermal Shock Investigation of Heat Flux Sensors for the Mars 2020 Backshell

In 2012 during the entry, descent, and landing of the Mars Science Laboratory (MSL), the MSL Entry, Descent, and Landing Instrumentation (MEDLI) sensor suite was collecting in-flight heatshield pressure and temperature data. The data collected by the MEDLI instruments has since been used for reconstruction of vehicle aerodynamics, atmospheric conditions, aerothermal heating, and Thermal Protection System (TPS) performance as well as material response model validation and refinement. The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite for the Mars 2020 heatshield and backshell is being designed to expand on the measurements and knowledge gained from MEDLI. Similar to MEDLI, MEDLI2 will measure the pressure and temperature of the heatshield. MEDLI2 will additionally measure the temperature, pressure, total heat flux, and radiative heat flux on the backshell. Since the backshell instrumentation is new to MEDLI2, Do No Harm (DNH) testing was conducted on instrumented backshell TPS (SLA-561V) panels. The panels consisted of four pressure port holes, one Mars Entry Atmospheric Data System (MEADS) pressure port plug, one MEDLI2 Integrated Sensor Plug (MISP) thermal plug, and one heat flux sensor. DNH testing was conducted to ensure the performance of the TPS was not degraded due to sensor integration and to characterize any TPS performance changes. The testing consisted of environmental testing— vibration, shock, thermal vacuum (TVAC) cycling— and bounding aerothermal (arc jet) testing.

Miller, R. A.↗

Laboratory-Based Thermal Shock Investigation of Heat Flux Sensors for the Mars 2020 Backshell

In 2012 during the entry, descent, and landing of the Mars Science Laboratory (MSL), the MSL Entry, Descent, and Landing Instrumentation (MEDLI) sensor suite was collecting in-flight heatshield pressure and temperature data. The data collected by the MEDLI instruments has since been used for reconstruction of vehicle aerodynamics, atmospheric conditions, aerothermal heating, and Thermal Protection System (TPS) performance as well as material response model validation and refinement. The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite for the Mars 2020 heatshield and backshell is being designed to expand on the measurements and knowledge gained from MEDLI. Similar to MEDLI, MEDLI2 will measure the pressure and temperature of the heatshield. MEDLI2 will additionally measure the temperature, pressure, total heat flux, and radiative heat flux on the backshell.Since the backshell instrumentation is new to MEDLI2, Do No Harm (DNH) testing was conducted on instrumented backshell TPS (SLA-561V) panels. The panels consisted of four pressure port holes, one Mars Entry Atmospheric Data System (MEADS) pressure port plug, one MEDLI2 Integrated Sensor Plug (MISP) thermal plug, and one heat flux sensor. DNH testing was conducted to ensure the performance of the TPS was not degraded due to sensor integration and to characterize any TPS performance changes. The testing consisted of environmental testing— vibration, shock, thermal vacuum (TVAC) cycling— and bounding aerothermal (arc jet) testing. During arc jet testing, the heat flux sensors embedded in the SLA-561V panels exhibited an unexpected temporary reduction in the heat flux sensor temperature and response. After review of the test results, it was determined that this unexpected response was confined to the two heat flux sensors that experienced the greatest thermal shock condition. This condition consisted of a liquid nitrogen (LN2) bath that induced temperatures of approximately -190°C, and then a transition (thermal shock) to an arc jet test at a heat rate of approximately 21 W/cm2. Both heat flux sensors that were exposed to this thermal shock experienced a blister in the thermal coating during the arc jet test.Two heat flux sensor thermal shock test series were performed to investigate the cause of the blistering and subsequent energy release. In these tests, the heat flux sensor was first cold soaked in either a dry ice or LN2 bath to induce temperatures of approximately -78°C or -190°C, respectively. Then the sensors were thermally shocked using two propane torches with a heat rate of either approximately 8 W/cm2 or 21 W/cm2. The key findings indicated that there is a correlation between thermal shock and the blistering observed in the DNH test series, and that the cause appeared to be rooted in the heat flux sensor epoxy that encapsulates the sensor thermopile.Since the heat flux sensors are required to measure heat fluxes up to 15 W/cm2 during the Mars 2020 entry, a third test series was designed to determine if blistering is an issue at this maximum expected flight heat flux. Results from all three thermal shock test series and a discussion about whether or not blistering of the heat flux sensor thermal coating could be an issue for the Mars 2020 mission will be presented.

Miller, R. A.↗

Progress Towards Modeling the Mars Science Laboratory PICA-NuSil Heatshield

The data collected by the Mars Science Laboratory (MSL) Entry, Descent and Landing Instrumentation, MEDLI, have become an established reference to assess the performance of engineering models of the Phenolic Impregnated Carbon Ablator (PICA) and to validate hypersonic computational fluid dynamics (CFD) tools for entry systems. MEDLI measurements are also extensively used as validation reference for current developments of high-fidelity material response models for PICA. So large has been the scientific output and impact of MEDLI that a follow-up instrumentation suite MEDLI2 is underway for the upcoming Mars 2020 mission.A feature neglected thus far in the modeling of the MSL heatshield, is the presence of a silicone-based room temperature vulcanizing coating designated NuSil CV-1144-0. NuSil was used to coat the entire MSL heatshield, including the MEDLI plugs, to mitigate the spread of phenolic dust from PICA, and limit contamination during clean room operations. NuSil CV-1144-0 is a space grade siloxane copolymer, designed as an oxygen protection barrier for extreme low temperature environment.Assessments conducted during MSL development demonstrated that the presence of NuSil had no adverse effect on the performance of PICA. However, evidence from ground testing of PICA-NuSil (PICA-N) models in the HyMETS arc-jet test facility suggests that the silicone changes the high temperature response of PICA. It is therefore critical to assess the importance of modeling the coating in ongoing code validation efforts.

Bessire, Brody K.↗

Progress Towards Modeling the Ablation Response of NuSil-Coated PICA

The Mars Science Laboratory (MSL) Entry, Descent and Landing Instrumentation (MEDLI) collected in-flight data largely used by the ablation community to verify and validate physics-based models for the response of the Phenolic Impregnated Carbon Ablator (PICA) material [1-4]. MEDLI data were recently used to guide the development of NASA’s high-fidelity material response models for PICA, implemented in the Porous material Analysis Toolbox based on OpenFOAM (PATO) software [5-6]. A follow-up instrumentation suite, MEDLI2, is planned for the upcoming Mars 2020 mission [7] after the large scientific impact of MEDLI. Recent analyses performed as part of MEDLI2 development draw the attention to significant effects of a protective coating to the aerothermal response of PICA. NuSil, a silicone-based overcoat sprayed onto the MSL heatshield as contamination control, is currently neglected in PICA ablation models. To mitigate the spread of phenolic dust from PICA, NuSil was applied to the entire MSL heatshield, including the MEDLI plugs. NuSil is a space grade designation of the siloxane copolymer, primarily used to protect against atomic oxygen erosion in the Low Earth Orbit environment. Ground testing of PICA-NuSil (PICA-N) models all exhibited surface temperature jumps of the order of 200 K due to oxide scale formation and subsequent NuSil burn-off. It is therefore critical to include a model for the aerothermal response of the coating in ongoing code development and validation efforts.

Meurisse, Jeremie B.↗

ANALYSIS OF THE MSL/MEDLI ENTRY DATA WITH COUPLED CFD AND MATERIAL RESPONSE.

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heat-shield using NASA's Phenolic Impregnated Carbon Ablator (PICA) material. PICA is a lightweight carbon fiber/polymeric resin material that offers out-standing performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to showcase and analyze the coupling between the material response and the aerothermal environment. As shown in Figure 1, the workflow is divided into the following steps. First, the aerothermal properties are computed in the Data Parallel Line Relaxation (DPLR) code [3] and used with the Nonequilibrium air radiation (NEQAIR) program [8] to compute radiative heating. Second, the thermal response inside the material is computed in the Porous material Analysis Toolbox based on Open-FOAM (PATO) using a fixed blowing correction parameter. Third, the pyrolysis gases computed in PATO are used as inputs to a blowing boundary condition within DPLR. Fourth, the new environment properties from DPLR are used in NEQAIR to provide an updated solution, then both the updated aerothermal environment and radiative heating are used in PATO without blowing correction. The third and fourth steps are then repeated until convergence in surface temperature is obtained. Convergence in the radiative heating is generally achieved before surface temperature, at which point the radiative heating is no longer updated. Char mass loss rates are forced to zero to produce a non-receding surface condition. For early time points in the trajectory, where flow around the MSL aeroshell is rarefied, the Direct Simulation Monte Carlo (DSMC) code, SPARTA, is used to compute the aerothermal environment. Iteration between PATO and SPARTA is not performed due to the computational cost of DSMC simulations. Preliminary results of the coupling between PATO and DPLR for the MSL heatshield atmospheric entry model are presented in Figures 2-4 at 65 seconds after entry interface. Figure 2 shows the surface temperature results from an uncoupled simulation in PATO with the blowing correction parameter applied (left) along with the coupled surface temperature after iteration (right). Figure 3 shows the surface temperature along the centerline from windward to leeward for easier comparison. Figure 4 shows the coupled and uncoupled pyrolysis gas blowing rate. Mars 2020 used a similar heatshield consisting of PICA for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against flight data from MEDLI. This work represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes.

Mars Science Laboratory↗

Analysis of MSL/MEDLI Entry Data with Coupled CFD and Material Response

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heatshield using NASA's Phenolic Impregnated Carbon Ablator (PICA) material [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers outstanding performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP) [2]. The objective of this work is to showcase and analyze the coupling between the material response and the aerothermal environment. As shown in Figure 1, the workflow is divided into the following steps. First, the aerothermal properties are computed in the Data Parallel Line Relaxation (DPLR) code [3] and used with the Nonequilibrium air radiation (NEQAIR) program [8] to compute radiative heating. Second, the thermal response inside the material is computed in the Porous material Analysis Toolbox based on OpenFOAM (PATO) [4,5,6] using a fixed blowing correction parameter. Third, the pyrolysis gases computed in PATO are used as inputs to a blowing boundary condition within DPLR. Fourth, the new environment properties from DPLR are used in NEQAIR to provide an updated solution, then both the updated aerothermal environment and radiative heating are used in PATO without blowing correction. The third and fourth steps are then repeated until convergence in surface temperature is obtained. Convergence in the radiative heating is generally achieved before surface temperature, at which point the radiative heating is no longer updated. Char mass loss rates are forced to zero to produce a non-receding surface condition. For early time points in the trajectory, where flow around the MSL aeroshell is rarefied, the Direct Simulation Monte Carlo (DSMC) code, SPARTA [7], is used to compute the aerothermal environment. Iteration between PATO and SPARTA is not performed due to the computational cost of DSMC simulations. Preliminary results of the coupling between PATO and DPLR for the MSL heatshield atmospheric entry model are presented in Figures 2-4 at 65 seconds after entry interface. Figure 2 shows the surface temperature results from an uncoupled simulation in PATO with the blowing correction parameter applied (left) along with the coupled surface temperature after iteration (right). Figure 3 shows the surface temperature along the centerline from windward to leeward for easier comparison. Figure 4 shows the coupled and uncoupled pyrolysis gas blowing rate. Mars 2020 used a similar heatshield consisting of PICA for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against flight data from MEDLI. This work represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes.

Thermal Protection Systems↗

Atlas of quasar energy distributions

We present an atlas of the spectral energy distributions (SEDs) of normal, nonblazar, quasars over the whole available range (radio to 10 keV X-rays) of the electromagnetic spectrum. The primary (UVSX) sample includes 47 quasars for which the spectral energy distributions include X-ray spectral indices and UV data. Of these, 29 are radio quiet, and 18 are radio loud. The SEDs are presented both in figures and in tabular form, with additional tabular material published on CD-ROM. Previously unpublished observational data for a second set of quasars excluded from the primary sample are also tabulated. The effects of host galaxy starlight contamination and foreground extinction on the UVSX sample are considered and the sample is used to investigate the range of SED properties. Of course, the properties we derive are influenced strongly by the selection effects induced by quasar discovery techniques. We derive the mean energy distribution (MED) for radio-loud and radio-quiet objects and present the bolometric corrections derived from it. We note, however, that the dispersion about this mean is large (approximately one decade for both the infrared and ultraviolet components when the MED is normalized at the near-infrared inflection). At least part of the dispersion in the ultraviolet may be due to time variability, but this is unlikely to be important in the infrared. The existence of such a large dispersion indicates that the MED reflects only some of the properties of quasars and so should be used only with caution.

Elvis, Martin↗

Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) Sensor Suite

The Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite seeks to address the aerodynamic, aerothermodynamic, and thermal protection system (TPS) performance issues during atmospheric entry, descent, and landing of the Mars 2020 mission. Based on the highly successful instrumentation suite that flew on Mars Science Laboratory (MEDLI), the new sensor suite expands on the types of measurements and also seeks to answer questions not fully addressed by the previous mission. Sensor Package: MEDLI2 consists of 7 pressure transducers, 17 thermal plugs, 2 heat flux sensors, and one radiometer. The sensors are distributed across both the heatshield and backshell, unlike MEDLI (the first sensor suite), which was located solely on the heat-shield. The sensors will measure supersonic pressure on the forebody, a pressure measurement on the aftbody, near-surface and in-depth temperatures in the heatshield and backshell TPS materials, direct total heat flux on the aftbody, and direct radiative heating on the aftbody. Instrument Development: The supersonic pressure transducers, the direct heat flux sensors, and the radiometer all were tested during the development phase. The status of these sensors, including the piezo-resistive pressure sensors, will be presented. The current plans for qualification and calibration for all of the sensors will also be discussed. Post-Flight Data Analysis: Similar to MEDLI, the estimated flight trajectory will be reconstructed from the data. The aerodynamic parameters that will be reconstructed will be the axial force coefficient, freestream Mach number, base pressure, atmospheric density, and winds. The aerothermal quantities that will be determined are the heatshield and backshell aero-heating, turbulence transition across the heatshield, and TPS in-depth performance of PICA. By directly measuring the radiative and total heat fluxes on the back-shell, the convective portion of the heat flux will be estimated. The status of the current tools to perform the post-flight data analysis will be presented, along with plans for model improvements.

Hwang, Helen H.↗

Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) Sensor Suite

The Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite seeks to address the aerodynamic, aerothermodynamic, and thermal protection system (TPS) performance issues during atmospheric entry, descent, and landing of the Mars 2020 mission. Based on the highly successful instrumentation suite that flew on Mars Science Laboratory (MEDLI), the new sensor suite expands on the types of measurements and also seeks to answer questions not fully addressed by the previous mission. Sensor Package: MEDLI2 consists of 7 pressure transducers, 17 thermal plugs, 2 heat flux sensors, and one radiometer. The sensors are distributed across both the heatshield and backshell, unlike MEDLI (the first sensor suite), which was located solely on the heat-shield. The sensors will measure supersonic pressure on the forebody, a pressure measurement on the aftbody, near-surface and in-depth temperatures in the heatshield and backshell TPS materials, direct total heat flux on the aftbody, and direct radiative heating on the aftbody. Instrument Development: The supersonic pressure transducers, the direct heat flux sensors, and the radiometer all were tested during the development phase. The status of these sensors, including the piezo-resistive pressure sensors, will be presented. The current plans for qualification and calibration for all of the sensors will also be discussed. Post-Flight Data Analysis: Similar to MEDLI, the estimated flight trajectory will be reconstructed from the data. The aerodynamic parameters that will be reconstructed will be the axial force coefficient, freestream Mach number, base pressure, atmospheric density, and winds. The aerothermal quantities that will be determined are the heatshield and backshell aero-heating, turbulence transition across the heatshield, and TPS in-depth performance of PICA. By directly measuring the radiative and total heat fluxes on the back-shell, the convective portion of the heat flux will be estimated. The status of the current tools to perform the post-flight data analysis will be presented, along with plans for model improvements.

Hwang, Helen↗

Mars Science Laboratory Heatshield Flight Data Analysis

NASA Mars Science Laboratory (MSL), which landed the Curiosity rover on the surface of Mars on August 5th, 2012, was the largest and heaviest Mars entry vehicle representing a significant advancement in planetary entry, descent and landing capability. Hypersonic flight performance data was collected using MSLs on-board sensors called Mars Entry, Descent and Landing Instrumentation (MEDLI). This talk will give an overview of MSL entry and a description of MEDLI sensors. Observations from flight data will be examined followed by a discussion of analysis efforts to reconstruct surface heating from heatshields in-depth temperature measurements. Finally, a brief overview of MEDLI2 instrumentation, which will fly on NASAs Mars2020 mission, will be presented with a discussion on how lessons learned from MEDLI data affected the design of MEDLI2 instrumentation.

Mars↗

Inverse Determination of Aeroheating and Charring Ablator Response

The Mars Science Laboratory (MSL) was protected during its Mars atmospheric entry by an instrumented heatshield that used NASA's Phenolic Impregnated Carbon Ablator (PICA). PICA is a lightweight carbon fiber/polymeric resin material that offers excellent performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of atmospheric entry and material response. MEDLI recorded, among others, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). These measurements have been widely used in the literature as a validation benchmark for state-of-the-art ablation codes. The objective of this work is to perform an inverse estimate of the MSL heatshield material properties and aerothermal environment during Mars entry from the MISP flight data.

Aeroheating↗

Heatshield Entry Modeling Using a Design, Analysis, and Optimization Toolbox

The Mars Science Laboratory (MSL) was protected during its Mars atmospheric entry by an instrumented heatshield that used NASA's Phenolic Impregnated Carbon Ablator (PICA). PICA is a lightweight carbon fiber/polymeric resin material that offers excellent performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of atmospheric entry and material response. MEDLI recorded, among others, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to showcase the capability of the Design, Analysis, and Optimization of Thermal Protection Materials (DAOTPM) software. DAO-TPM is a Python based framework that works as a link between mission design, aerothermal and radiative environment computation, Thermal Protection Systems (TPS) microstructure analysis, material response and optimization tools. The toolbox has a Graphical User Interface (GUI) that allows the user to build as well as run the various software and utilities used to design, analyze and optimize a heatshield during atmospheric entry.

Meurisse, Jeremie B. E.↗

Charactarization of Thermal Protection Systems

In 2012, NASA's mission of landing the Mars Science Laboratory (MSL) on Mars was successful. MSL was protected by an ablative heatshield of tiled low density material known as PICA (phenolic impregnated carbon ablator). The heatshield was instrumented with MEDLI (MSL Entry Descent Landing Instrument) a suite of sensors & thermocouples at discrete locations in order to monitor the in-depth ablator temperature response and surface pressure. MEDLI was designed and developed by NASA Langley, in partnership with NASA Ames Research Center for the purposes of probing Mars and evaluating the performance of the spacecraft upon entry into the Martian atmosphere. The flight data reduces the uncertainty in engineer models for predicting the response of a spacecraft towards the extreme heating environment of an entry into the Martian atmosphere. MEDLI2 is a part of the Mars 2020 mission and is the next-generation sensor suite for entry, descent, and landing. This data will again help engineers validate their flight models. Additionally, the atmospheric data, can help us understand atmospheric density and winds. This is a critical study for reducing risks to both robotic and future human missions to Mars. Engineered models for Mars 2020 are dependent upon parameters related to the materials response to heating and radiation. In this work, the thermal properties and other measurements of various ablative materials are analyzed to achieve greater utility of the 2012 MEDLI flight data and more accurately determine the parameters being used in Mars 2020. The purpose of this study was to measure specific heat, thermal conductivity, char yield, reflectance as a function of wavelength, and other thermal parameters and optical properties of various ablative materials. CO2(g) at extreme temperatures emits radiation impacting MEDLI2 flight predictions. Emissivity & absorptivity as a function of temperature were calculated from FTIR and UV-Vis data as a means of investigating whether these materials might absorb CO2 radiation upon entry into the Mars atmosphere.

HEEET↗

Determination of Aerothermal Environment and Ablator Material Response Using Inverse Methods

The Mars Science Laboratory (MSL) was protected during entry into the Martian atmosphere by a thermal protection system that used NASA’s Phenolic Impregnated Carbon Ablator (PICA). The heat shield of the probe was instrumented with the Mars Entry Descent and Landing Instrument (MEDLI) suite of sensors. MEDLI Integrated Sensor Plugs (MISP) included thermocouples that measured in-depth temperatures at various locations on the heatshield. The flight data has been used as a benchmark for validating ablation codes within NASA. This work seeks to refine the estimate of the material properties for the MSL heat shield and the aerothermal environment during Mars entry using estimation methods in DAKOTA on the temperature data obtained from MEDLI.

Thornton, John M.↗

Overview of Dragonfly Entry Aerosciences Measurements (DrEAM)

NASA Ames Research Center (ARC) leads the Dragonfly Entry Aerosciences Measurements (DrEAM) project, which is an aeroshell instrumentation suite on the Dragonfly mission that fulfills the Engineering Science Investigation requirement for the New Frontiers mission. NASA ARC is partnering with NASA Langley Research Center (LaRC) and the German Aerospace Center (DLR) to provide a comprehensive sensor suite, including a DLR-provided Data Acquisition System (DAS). DrEAM will provide key aerothermodynamic data and performance analysis for Dragonfly’s forebody and backshell Thermal Protection System (TPS). Titan’s atmosphere predominantly consists of ni-trogen (~98% by mole) with small amounts of me-thane (~2% by mole) and other trace gases. CN is a strong radiator, and is found in nonequilibrium con-centrations for Titan entry. The accurate modeling of nonequilibrium CN radiation has proven to be a diffi-cult task. Prompted by the Huygens mission, many experimental campaigns and analyses were performed to better understand the aerothermal environments experienced by the probe during Titan entry [1]. How-ever, the Huygens probe carried no heatshield instru-mentation. Therefore, the DrEAM sensor suite will sig-nificantly advance the state-of-the-art not only by documenting the environment and performance of Dragonfly’s entry system but also by making key in situ measurements in Titan’s atmosphere for the first time. Aerothermal environments and TPS response will be measured using sensors whose flight heritage is tak-en from the Mars Entry, Descent, and Landing In-strumentation 2 (MEDLI2) thermocouple plugs and the COMbined Aerothermal and Radiometer Sensor (COMARS) suite [2], with the latter supplied by DLR. The MEDLI2 project used embedded thermocouples to directly measure the in-depth TPS temperature-time history at several locations on the heat shield and backshell of the Mars 2020 entry vehicle. These tem-perature measurements, in turn, can be used to infer surface environments via an inverse analysis proce-dure analogous to that used for MEDLI. For DrEAM, the thermocouple plug subsystem will be known as Dragonfly Sensors for Aero-Thermal Reconstruction (DragSTR). On Schiaparelli, the COMARS suite in-cluded three total surface-mounted heat flux sensors, three pressure sensors, and one radiometer. For DrEAM, the COMARS package will be known as the COmbined Sensor System for Titan Atmosphere (COSSTA). Since the methane concentration in the Titan atmos-phere is directly proportional to the radiative heat flux, the COSSTA measurements will be used to reduce the current uncertainty in the methane volume fraction. Atmospheric density measurements and capsule aero-dynamic data will be obtained through the onboard Inertial Measurement Unit (IMU), supplemented by pressure transducers similar to those used by the MEDLI and MEDLI2 projects. The DrEAM pressure sensors will be known as the Dragonfly Atmospheric Flight Transducers. (DrAFT). The pressure measure-ments, when combined with data from the on-board IMU, will allow for reconstruction of such quantities as vehicle Mach number, freestream density, and atmos-pheric winds. DrAFT measurements will enhance Dragonfly trajectory reconstruction and enable a sepa-ration of the aerodynamics from the atmosphere, as was done for MEDLI [3] and is currently in process for the MEDLI2 flight data set.

EDL↗

Objective Structured Clinical Evaluation (OSCE) of an Artificial Intelligence (AI) Clinical Decision Support System (CDSS) Tool

BACKGROUND Objective Structured Clinical Evaluations (OSCEs) have long been established as a robust methodology for summative assessment of clinical skills and decision-making during medical education. The recent integration of Artificial Intelligence (AI) into clinical decision-making processes has prompted the need for novel evaluation frameworks to assess the efficacy and reliability of AI clinical decision support system (CDSS) tools. This abstract outlines the process of quantitatively evaluating a novel CDSS (“Doc in a Box” Google 2024) trained on curated medical spaceflight data in the psychomotor domain as it interfaces with a human volunteer acting as the crew medical officer (CMO). PURPOSE The AI CDSS under review was developed as part of the Lunar Command and Control Interoperability (LuCCI) project, which is intended to address a gap in how Lunar Surface Systems (LSS) would interoperate across multiple programs, commercial partners, and international partners. The project objective is to define, prototype, integrate, and evaluate an interoperable lunar command, control, data, and software reference architecture to enable autonomy and informatics capability through common standards across LSS. A multi-modal AI-based CDSS compatible with Federated LSS will assist clinicians in diagnosing and managing complex medical conditions by providing evidence-based recommendations through predictive analytics. Given the critical role of decision-support as NASA continues to evolve its Earth-independent medical operations (EIMO), it is imperative to ensure that such AI tools perform reliably and align with clinical standards during progressive lunar and Martian exploration class missions. METHODS The OSCE framework, traditionally used for evaluating human clinicians, was adapted to assess the AI tool's decision-making capabilities in simulated clinical scenarios. In this adapted OSCE, the AI CDSS was tested across a series of structured clinical scenarios designed to mimic real-life spaceflight patient cases. These scenarios included a range of conditions and complexities, allowing for comprehensive assessment of the tool's performance. Key evaluation metrics included accuracy of diagnosis, timeliness of decision-making, and appropriate recommendations for therapies. The OSCE was scored by human physician evaluators who assessed the AI's recommendations in comparison with expert clinicians' medical decision making to ensure alignment with best practices and the standard of care. RESULTS Preliminary results indicate that the AI CDSS demonstrated high accuracy in diagnostic recommendations and decision support across various scenarios. However, certain limitations were noted, such as occasional discrepancies in handling complex or nuanced cases that required a more contextual understanding. Additionally, the tool scored higher on the diagnostic portion of the rubric, with lower scores in the therapeutic recommendations. These findings highlight the importance of continuous refinement and validation of AI tools through rigorous evaluation frameworks like the OSCE. The adaptation of OSCEs for AI tools presents several advantages, including a structured and reproducible approach to evaluation, the ability to test AI systems in diverse clinical scenarios, and the opportunity to benchmark AI performance against established clinical standards to permit charting of future progress as aerospace medicine evolves as a discipline. Remaining challenges include ensuring that these evaluations capture the full spectrum of clinical decision-making scenarios that will be confronted by CMOs during missions and adequately reflecting real-world variability of the austere spaceflight environment. CONCLUSION Employing OSCEs to evaluate AI clinical decision support tools offers a promising approach to validating their clinical utility and efficacy. This methodology not only provides insights into the tool's performance but also fosters ongoing improvement and alignment with standard of care practices. Future research should focus on refining these evaluation processes and addressing limitations to enhance the integration of AI tools in clinical spaceflight settings. REFERENCES Scott S, Hearns V, Barker MA. Testing Clinical Skills: A Look at the OSCE and USMLE Clinical Skills Exams. S D Med. 2019 Oct;72(10):451-453. Majumder MAA, Kumar A, Krishnamurthy K, Ojeh N, Adams OP, Sa B. An evaluative study of objective structured clinical examination (OSCE): students and examiners perspectives. Adv Med Educ Pract. 2019 Jun 5;10:387-397. Karam VY, Park YS, Tekian A, Youssef N. Evaluating the validity evidence of an OSCE: results from a new medical school. BMC Med Educ. 2018 Dec 20;18(1):313.

Ariana M Nelson↗

Constraints on the formation history of the elliptical galaxy NGC 3923 from the colors of its globular clusters

We present a study of the colors of globular clusters associated with the elliptical galaxy NGC 3923. Our final sample consists of Wasington system C and T(sub 1) photometry for 143 globular cluster candidates with an expected contamination of no more than 10%. We find that the color distribution of the NGC 3923 globular cluster system (GCS) is broad and appears to have at least two peaks. A mixture modeling analysis of the color distribution indicates that a two-component model is favored over a single-component one at a high level of confidence (greater than 99%). This evidence for more than one population in the GCS of NGC 3923 is similar to that previously noted for the four other elliptical galaxies for which similar data have been published. Furthermore, we find that the NGC 3923 GCS is redder than the GCSs of previously studed elliptical galaxies of similar luminosity. The median metallicity inferred from our (C-(T(sub 1)))(sub 0) colors is (Fe/H)(sub med) = -0.56, with an uncertainty of 0.14 dex arising from all sources of uncertainty in the mean color. This is more metal rich than the median metallicity found for the GCS of M87 using the same method, (Fe/H)(sub med) = -0.94. Since M87 is more luminous than NGC 3923, this result points to significant scatter about any trend of higher GCS metallicity with increasing galaxy luminosity. We also show that there is a color gradient in the NGC 3923 GCS corresponding to about -0.5 dex in Delta(Fe/H)/Delta(log r). We conclude that the shape of the color distribution of individual GCSs and the variation in mean color among the GCSs of ellipticals are difficult to understand if elliptical galaxies are formed in a single protogalactic collapse. Models in which ellipticals and their globular clusters are formed in more than one event, such as a merger scenario, are more successful in accounting for these observations.

Zepf, Stephen E.↗